Efd 702 INSTALLATION GUIDE

Introduction
The 702 Series dispense valve is simple to use and will operate many millions of cycles without maintenance. The 702 Series incorporates a compact, precise, adjustable diaphragm for dispensing low to medium viscosity fluids.
The 702 Series has a unique flat seat that enables the valve to provide full flow at one half the stroke of a standard EFD 750 Series valve. This design also reduces turbulence and provides bubble-free dispensing of dyes and UV-cure resins used in the optical media and other industries. The central control air allows the valve to obtain its small size.
Each valve is shipped with a stroke control adjustment key.
702 Series Dispense Valve
INSTALLATION GUIDE
Tamper-resist stroke control
Fluid supply line
Control air hose
Air cylinder body
Fluid body
Tip retaining nut
Inlet fitting
Dispensing tip
Electronic pdf files of EFD®manuals are also available at www.efd-inc.com/manuals.html.
USA: 800-556-3484 or +1-401-434-1680 Europe: 0800 585733 or +44 (0) 1582 666334 Asia: +86 (21) 5854 2345 technical@efd-inc.com www.efd-inc.com
®
A NORDSON COMPANY
1. Mount valve with an EFD universal
valve mount (#7002VM) or other fixture.
2. Connect fluid supply line to valve.
Install M5 exterior thread fluid fitting. (Not supplied with 702M model.)
3. Connect the fluid supply line to
reservoir.
4. Connect valve control air hose to
ValveMate
controller (or other pneumatic switch) used to control valve open time.
5. Choose a dispensing tip—small
tips (20 gauge) for low-viscosity fluids and larger (14 gauge) for higher viscosities. We recommend EFD PTFE-coated tips for the 702M-SS model.
6. Fill reservoir by pouring fluid
directly into tank liner or manufacturer’s bottle placed inside reservoir. Secure cover prior to setting pressure.
7. Set reservoir pressure to low for thin
fluids and higher for thick fluids.
8. Set the stroke control starting with
no more than 1/2 turn open from closed position (full clockwise).
*
9. Place a cup under the dispensing
tip and actuate the valve until fluid lines, valve and dispensing tip are free of air.
10. Set desired flow rate by adjusting
fluid reservoir pressure or changing dispensing tip.
*
Do not overtighten the stroke adjustment or open it more than one full turn. If open more than one turn, pressurized liquid could force open the diaphragm seal, resulting in continuous liquid flow.
Installation
Prior to installing this valve, please read the associated reservoir and valve controller operating instructions to become familiar with the operation of all components of the dispensing system.
POWER
RUN
SETUP
CYCLE
Test
Clear
Purge
Run
Setup Program
Fast Slow
Time Set
Steady
Fast Slow
Time Set
STOP
Pressure
Time
®
A NORDSON COMPANY
To pressurize
To exhaust
Set desired deposit size by adjusting valve open time. Refer to valve controller operating manual.
11
O
pen
Close
8
1
7
5
2
6
4
10
3
9
Air Output
ut
Exhaust
r