Eaton Electrical Powerware 9390 User Manual

1
Powerware 9390 40 - 160 kVA
2
The industry’s best combination of efficiency, management of THD, power factor, and power protection
With the introduction of the Powerware 9390, you can now enjoy an unmatched combination of power protection features in a single system. The new three­phase UPS is the result of comprehensive research and user insight gathered by Eaton to develop the best combination of power performance, battery management, scalable architecture, flexibility, and service.
The Powerware 9390 UPS features innovations that combine to deliver the industry’s best overall power performance. Built on more than 40 years of UPS design expertise, the Powerware 9390 excels in four key factors:
1. Efficiency - maximum usable output power relative to input power
2. Total harmonic distortion (THD) - keeping input current distortion within acceptable limits
3. Power factor - managing phase shifts between voltage applied and current drawn by circuits
4. Double-conversion topology - complete isolation of protected loads from input utility power
produces cooler operating conditions within the UPS, which extends the life of components and increases overall reliability and performance.
Low THD enhances compatibility with generators
The Powerware 9390 uses a new input circuit that is uniquely capable of keeping Total Harmonic Distortion (THD) at a low level—less than 5 per cent—without compromising efficiency. A key benefit is that the UPS is therefore compatible with a wide range of generators, even though generator output frequencies will fluctuate when the UPS transitions to generator power and as other loads are started up.
Power factor performance maximises compatibility and meets high power factor load requirements
The closer the power factor is to unity, the more efficient the transfer of power between source and load. With an input power factor of 0.99, the Powerware 9390 UPS is exceptionally compatible
with diverse power sources, especially auxiliary generators.
On the output side, the 9390 can also provide its full power capability to loads that have a wide range of leading and lagging power factors, spanning all known computer loads.
Double-conversion topology provides the best protection possible
With the Powerware 9390’s double-conversion process, your sensitive electronic systems are completely isolated from raw utility power and all its irregularities. Double conversion provides the highest level of protection available and enables equipment to perform to manufacturer specifications.
Whether you are selecting a UPS for a branch office, manufacturing floor, medical facility, or a large data centre, there is a Powerware 9390 model that delivers just the right combination of performance and price for your needs. Visit our website www. powerware.com for more information.
High efficiency reduces overall cost of ownership
The efficiency rating of a UPS is a measure of the energy the UPS uses for its own operation and dissipates usually in the form of heat. For example, a UPS that is 90 per cent efficient delivers 90 kW of useful output power for every 100 kW it takes in. The more efficient the UPS, the less you pay to run your protected equipment and to cool the UPS.
With a transformerless design and sophisticated sensing and control circuitry, the Powerware 9390 UPS delivers an efficiency of up to 94 per cent. In addition to dramatic cost savings, this level of system efficiency extends battery run times and
TYPICAL APPLICATIONS:
• Data centres, server farms
• Building, banking and telecommunication systems
• Industrial automation equipment
• Healthcare systems
POWERWARE 9390’S EFFICIENCY TRANSLATES INTO BIG SAVINGS:
Competitive UPS, Powerware 9390, efficiency 90% efficiency up to 94% Utility power dissipated (per year) 87,600 kWh 52,560 kWh Energy cost (at 0.08/kWh) 7,008 4,205 Cooling cost 2,336 1,388 Total 9,344 5,593 Annual savings 3,751
3
Communication options –connect anywhere
ConnectUPS Web/SNMP card is a complete UPS monitoring, control and shutdown solution in a networked IT environment. In case of alert, the Web/ SNMP card can notify users and administrators through e-mail and SNMP traps. In case of a prolonged power failure the protected computer systems can be shut down in a graceful manner with NetWatch and LanSafe software.
HTTP, SNMP, e-mail, WAP and Telnet compatibility enable dynamic and versatile support for a large variety of system configurations.
The XSlot card for the 9390 also integrates a 3-port switching hub to support multiple PCs or networking equipment.
Environmental Monitoring Probe (EMP) enables you to remotely monitor environmental conditions as easily as you monitor power conditions. It adds temperature, humidity and two contact closure monitoring capabilities to ConnectUPS Web/ SNMP card. It can trigger operating system shutdown if user-defined thresholds
1. POWER FAILURE
2. POWER SAG
3. POWER SURGE
4. UNDERVOLTAGE
5. OVERVOLTAGE
6. SWITCHING TRANSIENT
7. LINE NOISE
8. FREQUENCY VARIATION
9. HARMONIC DISTORTION
are exceeded or contact closure status changes.
Relay/AS400 card provides an easy connection to IBM AS/400 series computers as well as industrial and building management systems. You can also build a solution for a remote ON/ OFF function with the relay card.
Powerware Software Suite, our exclusive collection of software on a CD-rom, incorporates a full line of shutdown and monitoring software products to enhance the protection provided by Powerware UPSs. The software suite, conveniently packed on one CD-rom, follows every UPS free of charge.
ConnectUPS Web/SNMP xHub
Powerware Modbus Card is an XSlotTM UPS connectvity device that provides continuous, reliable and accurate remote monitoring of your UPS system through a Building Management System (BMS) or Industrial Automation System (IAS). The card integrates data from the UPS into the user’s management system using Modicon®‚ Modbus RTU Protocol. Key power quality and UPS status information may be monitored in real time to aid in the management of the UPS and notification of potential power problems.
Multi-Server card is a power quality connectivity product designed to enable multiple devices connected to a single UPS system to be managed and controlled independently. The Multi­Server Card allows separate communication with up to six connected servers with mixed operating systems.
XSlot modem card connects your UPS device to Powerware’s remote monitoring centre for a 24/7 software based, fully automatic remote UPS inspection over the telephone network.