Eaton Electrical MN05401014E User Manual

MN05401014E 1
español
englishfrançais
deutsch
italiano
Operating Instructions Electronic Totalizer E5024E0402
• 6-digit adding counter with RESET function
• Red LED display, character height 8 mm [0.31 in.]
• Display range 0 – 999 999
• Lead zero blanking
• Programming via two setting keys on the front side
• During programming, the display guides the user with text prompts
1.1 Safety instructions and warnings
Only use this display
– according to its intended purpose – if its technical condition is perfect – adhering to the operating
instructions and the general safety instructions.
1.2 General safety instructions
1. Before carrying out any installation or mainte-
nance work, make sure that the power supply of the digital display is switched off.
2. Only use this digital display in a way accord-
ing to its intended purpose: If its technical condition is perfect. Adhering to the operating instructions and the general safety instructions.
3. Adhere to country or user specific regulations.
4. The digital display is not intended for use in
areas with risks of explosion and in the branches excluded by the standard EN 61010 Part 1.
5. The digital display should only operated if it
has been correctly mounted in a panel, in accordance with the chapter “Technical data”.
1.3 Use according to the intended purpose
The digital display may be used only as a panel­mounted device. Applications of this product may be found in industrial processes and controls, in manufacturing lines for the metal, wood, plastics, paper, glass, textile and other processing indus­tries. Over-voltages at the terminals of the digital dis­play must be kept within the limits in Category II.
If the digital display is used to monitor machines or processes in which, in case of a failure of the device or an error made by the operator, there might be risks of damaging the machine or causing accidents to the operators, it is your responsibility to take appropriate safety measures.
2. Inputs
INP
Dynamic count input.
RESET
Dynamic RESET input. Linked in parallel to the red RESET key. Sets the counter to zero.
3. Setting of the operating pa ra me ters
a. Press both front side keys and switch on the
supply voltage or, if the supply voltage is already on, press both keys simultaneously for 5 s.
b. The display shows
c. After releasing the keys, the display shows
CHS Controls AB
Tel +46 42 38 61 00, Fax +46 42 38 61 29 chs@chscontrols.se www.chscontrols.se
MN05401014E:MN05401014E 2/9/07 1:26 PM Page 1
!
2 MN05401014E
30 Hz filter off (f
max
)
30 Hz filter on
4.2 Switching on the 30 Hz filter (INP)
4.3 Decimal point setting
The decimal point determines the way of displaying the count values. It does not affect counting.
0 no decimal place
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
4.4 RESET Mode
manual reset via the red RESET key and electrical reset via the RESET input
no reset (red RESET key and RESET input locked)
only electrical reset via the RESET input
only manual reset via the red RESET key
4.5 End of programming
The programming routine is repeated once more. The values set until now can be checked and modified.
The programming routine will be exited and all values set will be stored as new parameters. Afterwards the device is ready for operation.
npn: sinking sensor
pnp: sourcing sensor
c1. Hold the left key pressed and press the right
key to leave the programming operation
c2. Press the right key to switch to
.
d. Hold the left key pressed and press the right
key to switch to the first parameter.
e. After releasing the keys, the display alter-
nates between the menu title and the current menu item setting. After pressing any key, only the menu item setting is displayed.
f. Pressing the right key will switch the menu
item setting to the next value. If figures are to be input (e.g. when setting the scaling factor), select first the digit using the left key, and then set the value using the right key.
g. Hold the left key pressed and press the right
key to switch to the next menu item.
h. The last menu title “EndPro” allows the user,
when selecting “Yes”, to exit the programming menu and to store the new values. If “no” is selected, the programming routine is repeat­ed, the latest values set remaining active. They can now be checked again or modified.
4. Programming routine
The programmable parameters of the device are described below, in succession. The device is fully programmed after one pass of the routine.
The first values stated correspond to the factory settings.
4.1 Polarity of the inputs
The filter provides input damping*
* where bounce occurs, e.g. with contacts
MN05401014E:MN05401014E 2/9/07 1:26 PM Page 2
CHS Controls AB
Tel +46 42 38 61 00, Fax +46 42 38 61 29 chs@chscontrols.se www.chscontrols.se
MN05401014E 3
english
5. Technical data
Supply voltage:
DC power supply: 10 – 30V DC/max. 40 mA
Display: 6 digits, red 7 segment
LED display, height 8 mm [0.31 in.]
Data retention: EEPROM
Polarity of the inputs:
Programmable, npn or pnp (sinking or sourcing) for all inputs
Input resistance:
appr. 5 kOhm
Count frequency:
Minimum pulse length for the reset input:
5 ms
Input sensitivity: Standard sensitivity:
DC power supply: Low: 0 – 0.2 x UB[V DC]
High: 0.6 x UB – 30 [V DC] UB= Supply Voltage
Pulse shape: any*,
Schmitt Trigger inputs
Ambient temperature:
-20 to +65°C [-4 to 149°F]
Storage temperature:
-25 to +70°C [-9 to 158°F]
EMC:
In compliance with the EC Directive 2004/108/EEC
Noise emission: EN 61 000-6-3/
EN 55 011 Class B
Noise immunity: EN 61 000-6-2
* at maximum frequency (50-50 duty cycle)
Housing: For front panel mounting
48 x 24 mm [1.89 x 0.94 in.] acc. to DIN 43700, RAL 7021, dark grey
Weight: appr. 50 g [1.76 oz.]
Front panel rating: IP 65
Cleaning:
The front of the units is to be cleaned only with a soft cloth moistened with water.
6. Terminal assignment
1 10 – 30V DC 2 0V GND 3 INP 4– 5 Reset
DC power supply: 24V 12V Input level: Standard typ. low level: 2.5V 2.0V typ. high level: 22.0V 10V
Fmax:* 60 kHz 20 kHz
MN05401014E:MN05401014E 2/9/07 1:27 PM Page 3
CHS Controls AB
Tel +46 42 38 61 00, Fax +46 42 38 61 29 chs@chscontrols.se www.chscontrols.se
4 MN05401014E
8. Dimensions:
Front bezel
Wiring diagram
Counter sinking Af3, DIN 74
1
7. Contents
1 Digital display 1 Panel mounting clip 1 Bezel for screw mounting, panel cut out
50 x 25 mm [1.97 x 0.98 in.]
1 Bezel for clip mounting, panel cut out
50 x 25 mm [1.97 x 0.98 in.] 1 Seal 1 Multilingual operating instructions
MN05401014E:MN05401014E 2/9/07 1:27 PM Page 4
CHS Controls AB
Tel +46 42 38 61 00, Fax +46 42 38 61 29 chs@chscontrols.se www.chscontrols.se
24 [0.94]
26 [1.10]
40 [1.57]
32 [ 1.26]
1
48 [1.89]
53 [2.09]
56 [2.20]
22 x 5 [0.87 x 1.77]
25 x 50
[0.98 x 1.97]
1 [0.04]
4 [0.16]
25 x 50
[0.98 x 1.97]
1 [0.04]
4 [0.16]
max. 19.3 [0.76]
4 [0.16]
6.5 [0.26]
59 [2.32]
25 + 0.5
[0.98 + 0.02]
50 + 0.6 [1.97 + 0.02]
25 [0.98]
M3
50 [1.97]
32 ± 0.01
[1.26 ± 0.004]
MN05401014E 5
español
1. Descripción
• Contador totalizador con 6 décadas y función RESET
• Pantalla de LED rojos, altura 8 mm
• Intervalo de visualización 0..999 999
• Supresión de los ceros en cabeza
• Programación con dos teclas de la cara delantera
Programación guiada por mensajes en la pantalla
1.1 Instrucciones de seguridad y
advertencias
Utilizar este visualizador únicamente
– de acuerdo con su función
material
– si se encuentra en perfecto
estado técnico
– respetando las instrucciones
deutilización y las instrucciones generales de seguridad.
1.2 Instrucciones generales de
seguridad
1. Antes de todo trabajo de instalación o
mantenimiento, asegúrese de que la alimentación del visualizador digital está cortada.
2. Utilizar este visualizador únicamente de
acuerdo con su función material: Si se encuentra en perfecto estado técnico. Respetando las instrucciones de utilización y las instrucciones generales de seguridad.
3. Cumplir las normativas correspondientes al
país y al usuario.
4. Este visualizador digital no debe utilizarse en
zonas que presenten riesgo de explosión y en entornos de uso excluidos de la norma EN 61 010 Parte 1.
5. Este aparato sólo debe funcionar encajado,
según la normativa profesiona, conforme a lo indicado en el capítulo “Características técnicas”.
1.3 Utilización correcta
Este visualizador digital sólo puede utilizarse encajado. La aplicación de este producto respecta a procesos industriales y de control, en cadenas de fabricación de industrias del metal, madera, materias plásticas, papel, vidrio, textiles, etc. Las sobretensiones en los bornes del aparato deben limitarse a los valores de la categoría de sobretensión II.
Si se implanta el visualizador digital para la vigilancia de máquinas o procesos en los que puede aparecer un riesgo de daños a la máquina o accidentes para los operarios en caso de avería o de un error de manipulación del aparato, usted tiene la obligación de adoptar medidas de seguridad apropiadas.
2. Entradas
INP
Entrada de conteo dinámica.
RESET
Entrada RESET dinámica conectada en paralelo con la tecla RESET roja. Pone el contador a cero.
3. Ajuste de los parámetros de funcionamiento
a. Pulsar las dos teclas de la cara delantera y
encender el aparato, o, con el aparato encen­dido, pulsar las dos teclas durante 5 s.
b. En la pantalla aparece el mensaje
c. Cuando se dejan de pulsar las teclas, la
pantalla indica
Instrucciones de puesta en servicio Contador totalizador electrónico E5024E0402
CHS Controls AB
Tel +46 42 38 61 00, Fax +46 42 38 61 29 chs@chscontrols.se www.chscontrols.se
MN05401014E:MN05401014E 2/9/07 1:27 PM Page 5
!
6 MN05401014E
c1. Mantener pulsada la tecla de la izquierda,
luego pulsar la tecla de la derecha para inter­rumpir la operación de programación.
c2. Pulsar la tecla de la derecha para que la
pantalla indique .
d. Mantener pulsada la teclade la izquierda,
luego pulsar la tecla de la derecha, para invo­car el primer parámetro.
e. Cuando se dejan de pulsar las teclas apare-
cen, en intervalos de un segundo, el título del menú y el ajuste actual del punto del menú. Pulsar una tecla: la pantalla deja de alternar y sólo indica el ajuste del punto del menú.
f. Durante el ajuste, si se pulsa una vez la tecla
de la derecha se pasa al valor siguiente del parámetro. Para introducir valores numéricos (p. ej., al ajustar el factor), seleccionar primero la déca­da con la tecla de la izquierda, luego ajustar su valor con la tecla de la derecha.
g. Para pasar al siguiente punto del menú, man-
tener pulsada la tecla de la izquierda y pulsar la tecla de la derecha.
h. El último punto del menú, “EndPro”, permite,
si se selecciona “Yes”, salir del menú de pro­gramación y asumir (almacenar en memoria) los nuevos valores. Si se selecciona “no”, la programación vuelve a comenzar después del inicio, conservando los últimos valores introducidos. En ese caso es posible compro­barlos o modificarlos de nuevo.
4. Rutina de programación
Los parámetros ajustables del dispositivo se indi­can abajo por su orden de aparición en la pan­talla. Por tanto, el aparato está totalmente pro­gramado después de un ciclo de programación.
Los primeros valores indicados corresponden al ajuste de fábrica.
4.1 Polaridad de las entradas
npn: conmutación a 0 V
pnp: conmutación a +U
B
Filtro 30 Hz desactivado (f
max
)
Filtro 30 Hz activado
4.2 Activación del filtro 30 Hz (INP)
4.3 Ajuste del punto decimal
El punto decimal determina la representación del valor de conteo. No tiene ningún efec­to sobre el conteo.
0 sin decimales
0.0 un decimal
0.00 dos decimales
0.000 tres decimales
4.4 Modo RESET
Puesta a cero manual con la tecla RESET roja y eléc­trica por la entrada RESET
No hay puesta a cero (tecla RESET roja y entrada RESET desactivadas)
Puesta a cero eléctrica sólo por la entrada RESET
Puesta a cero manual sólo por la tecla RESET roja
4.5 Fin de la programación
La rutina de programación se realiza otra vez. Los val­ores introducidos pueden comprobarse y modificarse.
La rutina de programación se termina y los valores introducidos se tienen en cuenta como nuevos parámetros. El dispositivo queda entonces listo para funcionar.
El filtro amortigua la entrada*
* en caso de rebotes; p. Ej., con contactos
MN05401014E:MN05401014E 2/9/07 1:27 PM Page 6
CHS Controls AB
Tel +46 42 38 61 00, Fax +46 42 38 61 29 chs@chscontrols.se www.chscontrols.se
Loading...