Operator Interface Products
2
ELC Graphics Panels
Graphics Panels
ELC Graphics Panels
Product Description
ELC Graphics Panels are simple to
program and easily connect to ELC
products. ELC graphics panels make
modifying an application quick and easy
and also connect to Cutler-Hammer
MVX drives, IQ MODBUS meters and
many other devices. With over 30
objects that can be placed anywhere
on the display, these tough panels
also communicate to other major
controllers. These graphics panels
have two serial ports which can be
used simultaneously to communicate.
Transfer applications to or from these
graphics panels using the handy
transfer module. Ten programmable
functions keys provide easy to change
pages, input numeric values, enter
alpha-numeric passwords, set, reset
and more. Create alarms, password
protect, import bitmaps, and use many
different fonts.
Protocols Supported
Eaton D50/D32LT, D320
■
■
Eaton ELC
Eaton MVX ASCII
■
■
Eaton MVX RTU
■
MODBUS ASCII
MODBUS RTU
■
■
AB DF1
Mitsubishi FX Series
■
■
Mitsubishi FX2N Series
Koyo K-Sequence
■
■
LG 200S
■
OMRON C-Series
Siemens 57-200 Series
■
■
ASCII Slave Mode
And more...
■
March 2008
0
50
100
®
No Alarms
Ta nk Fill Level
ELC-GP02
RUN
ELC-GP04
RUN
F3
F4
STOP
Features
Table 1. ELC Graphics Panel Features
ItemELC-GP02ELC-GP04
Display Screen
ScreenSTN-LCD
ColorMonochromatic
Back-lightThe back-light automatic turn off time is 1 – 99 minutes
(back-light life is 50 thousand hours at 25°C)
Resolution160X32 pixels128X64 pixels
Display Range72 mm (W) X 22 mm (H)67mm (W) X 32mm (H);
Waterproof Class of Front PanelUL Type 4X Outdoor Rated
Agency CertificationsUL 508, cUL (CSA C22.2 No. 14); CE (Low Voltage Directive);
Class 1 Div 2 Groups A, B, C, D
Technical Data and Specifications
Table 4. Environmental Ratings/Specifications
DescriptionSpecification
Transportation & Storage
Temperature-4° – 140°F (-20° – 60°C)
Operating
Temperature32° – 122°F (0° – 50°C)
Humidity20 – 90% RH (non-condensing)
Communication InterfaceCOM1: RS-232; COM2: RS-485/RS-422
Vibration0.5 mm displacement, 10 – 55 Hz, X, Y, Z three directions and
two hours for each direction
Impact10G, 11 mS, from X, Y, Z three directions and three times for
each direction
Weight0.53 Lbs. (0.24 kg)
Cooling MethodNatural Air Cooling
3
CA04801001EFor more information visit: www.eaton.com
Operator Interface Products
4
ELC Graphics Panels
Software and Accessories
March 2008
ELCSoftGP Programming
Software
ELCSoftGP Programming Software
configures all ELC graphic panels. With
ELCSoftGP, applications can be created,
edited, downloaded, uploaded, etc.
Move programs from one controller to
a different one with ease.
Requirements:
Operating Systems – Windows 98,
■
Windows ME, Windows 2000,
Windows XP
■
Hard Drive – At least 100M bytes
RAM – At least 256M bytes
■
ELCSoftGP Editing Environment
Accessories
ELC-GPXFERMOD Program
Transfer Module
The ELC-GPXFERMOD is a multifunction device that provides the ability to
back up an application already loaded
onto one of the ELC-GPxx units. It will
store all system settings like baud, ID,
etc., as well as passwords and the
application itself. Once stored in the
module, the application and settings
can be transferred to another ELCGPxx unit of the same model number.
Figure 1. ELC-GPXFERMOD
For more information visit: www.eaton.com
CA04801001E
March 2008
ELC-CBPCGP3 Cable
Use this cable to download or upload
applications between a PC and the
ELC-GPxx graphics panels. This cable
can also be used to transfer a program
from an ELC-GPxx to another ELCGPxx. This cable is 3 meters long.
ON PC (RS-232)
5
9
6
1
9 PIN D-SUB
PC COM Port
9 PIN D-SUB Female
Rx2
Tx3
GND5
Figure 2. PC to ELC-GPxx Cable
Operator Interface Products
ELC Graphics Panels
Software and Accessories
■
The Pin definition of 9 PIN D-SUB
RS-232:
ELC-GP04 COM Port
RS-232 9 PIN D-SUB Male
3
2
5
GP02/04 COM Port
9 PIN D-SUB Female
3
Tx
2
Rx
5
GND
Tx
Rx
GND
ON ELC-GP02/04
1
5
9 PIN D-SUB
5
6
9
ELC Power Supplies
All ELC modules operate from 24V DC.
These power supplies provide a convenient way to provide robust DC voltage.
L
N
24V
0V
POWER
ELC-PS01
Figure 3. ELC Power Supplies
Table 5. ELC Power Supply Specifications
ItemELC-PS01ELC-PS02
Dimensions WxHxD
in Inches (mm)
Input Power100 – 240V AC 50/60 Hz
Output Volts 24V DC
Output Current (A)1A2A
Watts2448
1.44 x 3.54 x 2.36
(36.5 x 90 x 60)
2.17 x 3.54 x 2.36
(55 x 90 x 60)
Product Selection
Table 6. Software and Accessories
DescriptionCatalog
Programming Software for GP Units
Program Transfer Module
Cable, PC to ELC-GPxx, 9.8 ft. (3 m)
Power Supply, 24 Watt, 1 Amp
Power Supply, 48 Watt, 2 Amp
Number
ELCSOFTGP
ELC-GPXFERMOD
ELC-CBPCGP3
ELC-PS01
ELC-PS02
L
N
2
4
V
0
V
E
L
C
-
P
Price
U.S. $
POW
S
0
2
ER
226.00
75.50
36.00
52.00
75.50
CA04801001EFor more information visit: www.eaton.com
Figure 4. ECL-GP04 — Approximate Dimensions in Inches (mm)
For more information visit: www.eaton.com
CA04801001E
March 2008
3.82
(97.0)
1.20
(30.5)
F0
Esc
F55F66F77F8
F11F22F33F4
0
F9
89
5.79
(147.0)
4
Enter
Operator Interface Products
ELC Graphics Panels
Dimensions
ALARM
RS-232
RS-485
Up
Pg Up
Right
Left
Pg Dn
Down
.14
1.40
(3.5)
(35.5)
3.35
(85.0)
7
5.31
(135.0)
Figure 5. ECL-GP02 — Approximate Dimensions in Inches (mm)
3.35
(85.0)
Cut-Out Dimensions
5.31 ~ 5.37
(135 ~ 136.5)
CA04801001EFor more information visit: www.eaton.com
Operator Interface Products
8
HMi Operator Interface
Operator Interface
Operator Interface
Product Description
Positioned between the ELC graphics
panels and the ePro series of operator
interfaces,
is the work horse of the
industry. All units feature a touchscreen and function keys to suit all
environments and applications. They
range in screen size and color to fit
available space and application needs.
All units offer RS-232, RS-485 and
RS-422 communications. The 6", 8"
and 10" units also offer Ethernet
communication with an accessory card.
Features
True analog touchscreen
■
■
Retentive internal data storage
Real time trending
■
■
Trend stored data
Alarming and alarm storage
■
■
Alarm frequency
■
Event storage (History)
USB programming
■
■
USB memory storage
USB printer
■
■
Add I/O
Macro programming
■
■
Multi-language
■
Recipe storage
Auto-scale application from 10 – 4"
■
■
On-line simulation
Off-line simulation
■
■
8-level password protection
HMi
HMi
March 2008
Protocols Supported
Table 7. Protocols Supported by HMi
Manufacturer Protocol
Allen Bradley Micro Logix
SLC 5
DanfossVLT 2800 (FC Protocol)
EatonELC Series
FaconFB Series
FestoFesto PLC
GE Fanuc90 Series SNP
HustHust CNC Controller
Hust CNC Controller v2
JetterNano Series
KeyenceKV/KZ Series
KoyoDL/SU Series
K-Sequence
LenzeLECOM-A/B protocol
LGMaster-K 120S/200S
Glofa GM6 CNET
Master-K CNET
Li YanLYPLC EX
M2iM2i Master
M2i Slave
MatsushitaFP Series
MirleFAMA SC
MitsubishiFX Series
FX2N
A Series/J71UC24
A2A/A2AS/A2USH
A1SH/A3N/A2ASH CPU Port
Q Series CPU Port
For use with the HMi series of touchscreens, this software supports all
of the features of HMi (listed on
Page 8). This easy to use Windowsbased software can run on Windows
2000 and XP with a minimum CPU of
Pentium III 500 Mhz, 256 MB RAM,
100 MB free hard disk space and
mouse.
■ Simulate an application on or off
line
■ Built in picture library
■ Create your own picture library
■ Screen manager
■ 70 on-screen object
■ Easy object setup
■ Monitor all states of objects
■ Macro editing
■ Scale application from 10" – 4"
■ Upload/download applications over
USB
■ Upload/download register data over
USB
■
Logic configuration for I/O expansion
modules
■ Ethernet communications
HMi Editor
HMi Screen Management
For more information visit: www.eaton.comCA04801001E
Operator Interface Products
Nameplate
Connection Port
Direct Mounting Hole
Input/Output Terminals
HMi Operator Interface
March 2008
Software and Accessories
Accessories
HMIECENT Ethernet Expansion Module
Ethernet Expansion Module
The HMIECENT expansion module adds 10/100 MB Modbus
TCP ability when plugged into the expansion slot of a 6", 8"
or 10" HMi unit. Up load and download programs and communicate to other Modbus TCP devices. No need for patch
or crossover cables as this module auto-detects and adjusts
for proper operation.
11
I/O Expansion Modules
The HMIEC0806 and HMIEC1612 are 14 and 28 discrete I/0
expansion modules providing 8 DC inputs and 6 relay outputs or 16 DC inputs and 12 relay outputs. Plug this module
into the available expansion slot on the back of the HMi unit
(not available on the 4" model) and it’s ready to use. No need
for a separate PLC controller as it is built into the unit. Combine operator interface and logic into a single platform —
use HMISOFT to build both the ladder logic and OI program.