Druck 1800 Specifications

GE
Measurement & Control
1800 Series
Druck High Performance Level Pressure Sensors
The PDCR 1800 transducer (mV output) and the PTX 1800 transmitter (4 to 20 mA output) are the latest generation of fully submersible titanium high performance sensors for measurement of hydrostatic liquid levels.
Features
• Ranges from 0.75 mH2O to 600 mH2O
• Accuracy ±0.10% full scale (FS) best straight line (BSL)
• Fully welded 17.5 mm diameter titanium construction
• Polyurethane and hydrocarbon resistant cables
• Full range of installation accessories
Applications
The 1800 Series incorporates many enhanced features gained from experience in supplying thousands of sensors for small and large scale installations worldwide. Example applications include:
• Potable water From ground water borehole to surface water level measurements in rivers, canals and reservoirs.
• Waste water and remediation Monitoring of secondary and outfl ow sewage levels and contaminated ground water levels in land fi ll sites.
• Tank Level From land based liquid storage vessels to on-board ship ballast tank monitoring.
• Sea Water Marine environmental applications, including tide gauging, coastal fl ood protection and wave profi ling, amongst others.
Reliability and Data Quality
The combination of a high technology sensor, together with advanced signal conditioning and packaging techniques, provides an ideal long term solution for reliable, accurate and economical level measurements. The micromachined silicon element is sealed within an all-titanium pressure module assembly, fully isolated from the pressure media. This is contained in a slimline, welded titanium body, terminated in an injection moulded cable assembly. The cable features a Kevlar® strain cord and is IP68 rated for indefi nite immersion in 700 mH materials to meet the application.
O, with a selection of cable
2
Ease of Use
A simple datum marked cable system is provided for ease of installation. 1 m datum points are clearly marked for quick and accurate cable alignment below ground level. In addition, a full range of related accessories simplifi es installation, operation and maintenance, including:
• Quick-release cable clamp assembly
• Slimline and short profi le sink weights
• Moistureproof Sensor Termination Enclosure
• In-situ pressure test/calibration adaptors
1800 Series Specifi cations
Pressure Measurement
Operating Pressure Ranges
PDCR 1800 (mV)
0.75, 1.5 mH2O gauge, 3.5, 7, 10, 15, 20, 35, 50, 70, 100,
150, 200, 350, 600 mH2O gauge and absolute
Other units may be specifi ed
PTX 1800 (mA)
Any zero based FS from 0.75 to 600 mH2O gauge and
3.5 to 600 mH2O absolute.
Other units may be speci ed, such as ftH2O, inH2O, bar, mbar, kPa, kg/cm2, psi
Overpressure
The operating FS pressure range may be exceeded by the following multiples with negligible effect on calibration:
• 8 x for ranges up to 1.5 mH2O
• 6 x for ranges above 1.5 to 3.5 mH2O
• 4 x for ranges above 3.5 mH2O (1400 mH2O max.)
Pressure Containment
• 10 x for ranges up to 3.5 mH2O gauge
• 6 x for ranges above 3.5 mH2O gauge (1400 mH2O maximum)
• 200 bar for absolute ranges
Media Compatibility
Fluids compatible with titanium (body), acetyl (nose cone) and polyurethane or Hytrel® 6108 (cable assembly)
Loading...