Druck 1800 User Manual

GE
Measurement & Control
Depth/Level
Druck Submersible Pressure Sensors Product Guide
Features
• High accuracy
• Robust construction
• Harsh media compatible
• High stability
• Low power/pulsed power operation
Applications
• Bore hole monitoring
• River level
• Tank level
• Tide and wave height
• Pump control
• Sand lter dierential
• Marine
Ground and Surface Water
One of the most ecient methods of measuring water level in wells, streams, rivers, canals and
reservoirs is the submersible pressure sensor. It uses
very little energy and provides an accurate long term measuring system solution.
There are many thousands of submersible GE pressure sensors installed worldwide in a variety of applications where the high stability and reliability of the devices have clearly delivered the lowest “cost­of-ownership” of any method available.
PDCR/PTX 1830
High specication, robust submersible pressure
sensor
• Ranges from 0.75 to 600 mH2O (1 to 900 psi)
• Millivolt or milliamp output
• Accuracy to ±0.06% FS
• Body diameter 17.5 mm ( 0.69 in)
• All-welded titanium construction
• Vented polyurethane cable with Kevlar® anti-stretch construction
• Hazardous area approvals
• Lightning protection
• Five-year anti-corrosion warranty
PTX 1730
Submersible pressure sensor
• Ranges from 3.5 to 600 mH2O (5 to 900 psi)
• Milliamp output
• Accuracy ±0.25%
• Body diameter 17.5 mm (0.69 in)
• All welded 316L stainless steel construction
• Vented polyurethane cable with Kevlar anti-stretch construction
®
UNIK 5000
Low cost submersible pressure sensor
• Range 0.7 to 200 mH2O (1 to 300 psi)
• Voltage, milliamp, millivolt output
• Accuracy to ±0.04%
• Body diameter 25 mm ( 1 in)
• All-welded 316L stainless steel with Hastelloy® C276 diaphragm
• Vented polyurethane cable with Kevlar® anti-stretch construction
• Supply current <3 mA (at no load)
• Gauge, absolute, dierential versions
UNIK 5000 Dierential
Submersible dierential pressure transmitter
• Ranges from 1 to 350 mH2O (1.5 to 500 psi)
• Voltage, milliamp, millivolt output
• Accuracy ±0.04% FS
• All-welded 316L stainless steel with Hastelloy C276 diaphragm
• Moulded polyurethane cable
Wastewater and Remediation
One of the most dicult applications in level measurement is sewage. Most methods suer from clogging, high-humidity interface from foaming or require line of sight.
GE has developed the PTX1290 with its ush elastometric diaphragm and titanium body in order to provide an inexpensive way to ensure highly reliable level
measurement in this harsh environment.
In groundwater remediation applications, undocumented chemicals may be encountered that could cause corrosion in stainless steel devices. All-welded titanium construction and robust Hytrel® cable is insurance against premature failure.
PTX 1290 (US Only)
Wastewater submersible pressure transmitter/ transducer
• Ranges from 1.75 to 15 mH2O (2.5 to 22.5 psi)
• Current output
• Accuracy ±0.25% FS
• Body diameter 30 mm (1.2 in)
• All-welded titanium construction
• Polytetrauoroethylene-coated elastometric ush diaphragm
• Hazardous area approvals (US only)
• Five-year anti-corrosion warranty
Reverse osmosis pump discharger and lter
Watershed data logger
PDCR/PTX 1840
High specication robust submersible pressure
sensor
• Ranges from 0.7 to 600 mH2O (1 to 900 psi)
• Millivolt or milliamp output
• Accuracy to ±0.06% FS
• Body diameter 17.5 mm (0.69 in)
• All-welded titanium construction
• Chemically resistant cable with Kevlar® anti-stretch construction
• Hazardous area approvals
• Lightning protection
• Five-year anti-corrosion warranty
Filtration dierentials and pumps
Water distribution
data logger
Storage tower water level
Sewage collection and lift stations pump discharge
Loading...