D-Link DPS-500 User Manual

Page 1
Redundant Power Supply
DPS-900
DPS-200
DPS-800
DPS-500
DPS-300
Chassis-based Redundant Power Supply
The DPS-200, DPS-300 and DPS-500 are redundant power supply designed for use with D-Link LAN switches. Each power supply connects to a switch to provide redundant backup power to the built-in power supply units inside the switch. These RPS can operate as stand-alone redundant power supply units, but they can also be installed in a DPS-800 or DPS-900 chassis. The DPS­900 is an 8-slot standard rack-mount size chassis designed to accommodate up to 8 RPS. Using a DPS-900, you can deploy up to 8 redundant power supply units in a standard equipment rack to support a stack of 8 stackable D-Link switches mounted in the same rack.
- DPS-200 redundant power supply: provides up to 60 watts output power.
- DPS-300 redundant power supply: provides up to 90 watts output power.
- DPS-500 redundant power supply: provides up to 140 watts output power.
- DPS-800 2-slot chassis: allows 2 RPS to be deployed in a standard equipment rack.
- DPS-900 8-slot chassis: allows up to 8 RPS to be deployed in a standard equipment rack.
Supported Devices
The DPS-200 redundant power supply supports the following D-Link devices:
DES-3326SR L3 stackable switch DES-3350SR L3 stackable switch
The DPS-300 redundant power supply supports the following D-Link devices:
DGS-3224TGR L2 Gigabit Switch
DGS-3212SR L2 stacking master DGS-3312SR L3 stacking master
The DPS-500 redundant power supply supports the following D-Link devices:
DGS-3224SR L2 stackable switch DGS-3324SR L3 stackable switch DGS-3324SRi L3 stackable switch
DPS-800 Chassis
This chassis is designed to hold 2 RPS for use with a stack of 2 stackable switches. The DPS-800 can be installed in a 19-inch standard equipment rack.
DPS-900 Chassis
The DPS-900 is especially designed to hold 8 RPS for use with a stack of 8 stackable switches installed in an equipment rack. Using this chassis, you can save space, while your cabling will look neat. The chassis comes with no power supply of its own. All redundant power supply units installed in this chassis will connect directly to their AC power source.
Power Supplies Stand-alone or Installed in Chassis
All power supply units come with their own solid metal case housing and LED status indicators. They can be used as stand-alone power supply units, or installed in the chassis. As they are independent units, they are hot-swappable when used with the chassis.
Page 2
DPS-200
Technical Specifications
Power Input
AC Input Voltage Rating
100VAC to 240VAC
AC Input Voltage Range
90VAC to 264VAC
AC Input Frequency Range
47 Hz to 63 Hz
AC Input Current
- 1.6A (RMS) max. for 115VAC
- 0.8A (RMS) max. for 230VAC
Maximum In-rush Current
- 30A max. @ 115VAC (at 25 degrees C ambient cold start)
- 60A max. @ 230VAC (at 25 degrees C ambient cold start)
Leakage Current
3.5mA max.
Power Output
Output Voltage
+12VDC
Minimum Load Current
0.5A
Maximum Load Current
5.0A
Line Regulation
+/-2% (measured output load from +/-10% rated load)
Load Regulation
+/-5% (measured output load from 20% to 100% rated load)
Output Ripple & Noise
120mV (measured bandwidth oscilloscope and terminated each output with 100uF capacitor and 0.1uF ceramic in parallel)
General Characteristics
Total Output Power
60 watts
Efficiency
75% min. @ max. load and 115VAC input
Hold Up Time
16mS min. at max. load and 115VAC input, @ 60Hz output drop down to 95% output voltage
Redundant Power Supply
Physical & Environmental
Dimensions
127mm (L) x 76mm (W) x 37mm (H) (device only)
Weight
0.83 kg (device only)
Operating Altitude
3,000 m (10,000 feet) max.
Storage Altitude
12,000 m (40,000 feet) max.
Operating Temperature
oo
0 to 50 C
Storage Temperature
oo
-20 to 80 C
Operating Humidity
20% to 80% RH
Storage Humidity
10% to 90% RH
Safety Standards
- UL 60950 3rd Edition
- TUV EN 60950
- CE Mark (LVD)
Safety Approvals
- CSA
EMI
- FCC Class B
- EN55022 (CISPR22) Class B
HI-POT Test
- Input to secondary: 3000VAC for 1 minute, 10mA
- Input to P.E.: 1500VAC for 1 minute, 10mA
Insulation Resistance
Input to secondary: >20Mohm 500VDC
Reliability (MTBF)
50K Hrs Min. at 25 degrees C 240VAC (max load)
Shock & Vibration
10-55Hz, amplitude 2G over entire frequency range. Sweep minute for X, Y and Z axis each 20 cycles.
Over Current Protection
Power supply protected against overload and short circuit applied to any one terminal -- auto restart (*)
(*) Output can be shorted permanently with damage
Over Voltage Protection
13.5V to 17V
AC Power Good (pwr-good) Signal Required
+3.3V (**)
(**) (1) Minimum high voltage is 2.0V with a maximum load current of 5.0mA (2) Maximum high voltage is 3.4V (3) Minimum low voltage is 0.0V (4) Power good signal must go low within 0.5ms before 12V output drops out of below 10.0V (5) Power good signal must go high within 2.5 seconds of application of power to the system
LED Status
- On: RPS good
- Off: RPS failed
Ordering Information
DPS-200 60-watt Output Redundant Power Supply DPS-800 2-slot Redundant Power Supply Chassis DPS-900 8-slot Redundant Power Supply Chassis
Page 3
DPS-300
Technical Specifications
Power Input
AC Input Voltage Rating
100VAC to 240VAC
AC Input Voltage Range
90VAC to 264VAC
AC Input Frequency Range
47 Hz to 63 Hz
AC Input Current
- 2A (RMS) max. for 115VAC
- 1A (RMS) max. for 230VAC
Maximum In-rush Current
- 30A max. @ 115VAC (at 25 degrees C ambient cold start)
- 50A max. @ 230VAC (at 25 degrees C ambient cold start)
Power Output
Output Voltage
+12VDC
Minimum Load Current
0A
Maximum Load Current
7.5A
General Characteristics
Total Output Power
90 watts
Redundant Power Supply
Efficiency
80% min. @ max.
Over Voltage Protection
13.5V to 17V
AC Power Good (pwr_good) Signal Required
+5V
LED Status
- On: RPS good
- Off: RPS failed
Physical & Environmental
Dimensions
196mm (L) x 195mm (W) x 50mm (H) (device only)
Weight
1.7 kg (device only)
Operating Temperature
o
o
0 to 40 C
Storage Temperature
oo
-10 to 55 C
Operating Humidity
5% to 95% non-condensing
Storage Humidity
5% to 95% non-condensing
Safety Standards
- UL 60950 3rd Edition
- TUV EN 60950
- CE Mark (LVD)
Safety Approvals
- CSA International
- CE
- CCC
Ordering Information
DPS-300 90-watt Output Redundant Power Supply DPS-800 2-slot Redundant Power Supply Chassis DPS-900 8-slot Redundant Power Supply Chassis
EMI
- FCC Class B
- BSMI
- C-Tick
Page 4
DPS-500
Technical Specifications
Power Input
AC Input Voltage Rating
115VAC to 230VAC
AC Input Voltage Range
90VAC to 264VAC
AC Input Frequency Range
47 Hz to 63 Hz
AC Input Current
- 4A (RMS) max. for 115VAC
- 2A (RMS) max. for 230VAC
Maximum In-rush Current
30A max. @ 115VAC (at 25 degrees C ambient cold start) 50A max. @ 230VAC (at 25 degrees C ambient cold start)
Leakage Current
3.5mA max.
Power Output
Output Voltage
- +5VDC
- +12VDC
Minimum Load Current
- 0A (+5VDC output)
- 0A (+12VDC output)
Redundant Power Supply
Safety Standards
- UL 60950 3rd Edition
- CSA 22.2 NO.234
- EN 60 950
Safety Approvals
- UL
- CSA
EMI FCC Class B
Maximum Load Current
- 1.5A (+5VDC output)
- 13A (+12VDC output)
General Characteristics
Total Output Power
140 watts
Efficiency
80% min. @ max.
Over Voltage Protection
13.5V to 17V
AC Power Good (pwr-good) Signal Required
+5V +12V
LED Status
- On: RPS good
- Off: RPS failed
Physical & Environmental
Dimensions
196mm (L) x 195mm (W) x 50mm (H) (device only)
Weight
1.5 kg (device only)
Operating Altitude
3,000 m (10,000 feet) max.
Storage Altitude
12,000 m (40,000 feet) max.
Operating Temperature
oo
0 to 50 C
Storage Temperature
o o
-20 to 80 C
Operating Humidity
20% to 80% RH
Storage Humidity 10% to 90% RH
A
C
I
T
N
I
O
U
N
M
M
C
O
O
C
M
M
L
I
A
S
R
S
E
I
O
D
N
E
F
U
A
S
Ordering Information
DPS-500 140-watt Output Redundant Power Supply DPS-800 2-slot Redundant Power Supply Chassis DPS-900 8-slot Redundant Power Supply Chassis
Specifications subject to change without prior notice. D-Link is a registered trademark of D-Link Corporation/D-Link System Inc. All other trademarks belong to their proprietors.
RECYCLABLE
Rev. 01 (Oct. 2003)
U.S.A Canada Europe Germany France Benelux Italy Iberia Sweden Norway Denmark Finland Singapore Australia Japan China India Middle East Turkey Chile Brasil South Africa Russia Taiwan D-Link Corp.
TEL: 1-949-788-0805 TEL: 1-905-8295033 TEL: 44-20-8731-5555 TEL: 49-6196-77990 TEL: 33-1-30238688 TEL: 31-10-282-1445 TEL: 39-2-2900-0676 TEL: 34-93-4090770
()
TEL: 46- 0 8564-61900 TEL: 47-22-309075 TEL: 45-43-969040 TEL: 358-9-2707-5080 TEL: 65-6774-6233 TEL: 61-2-8899-1800 TEL: 81-3-5434-9678 TEL: 86-10-8518-2533 TEL: 91-22-652-6696 TEL: 9714-8834234 TEL: 90-212-335-2553 TEL: 56-2-232-3185 TEL: 55-11-3094-2910
()
TEL: 2701266-52165 TEL: 7-095-737-3389 TEL: 886-2-2910-2626 TEL: 886-2-2916-1600
FAX: 1-949-753-7033 FAX: 1-905-8295095 FAX: 44-20-8731-5511 FAX: 49-6196-7799300 FAX: 33-1-30238689 FAX: 31-10-282-1331 FAX: 39-2-2900-1723 FAX: 34-93-4910795
()
FAX: 46- 0 8564-61901 FAX: 47-22-309085 FAX: 45-43-424347 FAX: 358-9-2707-5081 FAX: 65-6774-6322 FAX: 61-2-8899-1868 FAX: 81-3-5434-9868 FAX: 86-10-8518-2250 FAX: 91-22-652-8914 FAX: 9714-8834394 FAX:90-212-335-2500 FAX: 56-2-232-0923 FAX: 55-11-3094-2921
()
FAX: 27 0 1266-52186 FAX: 7-095-737-3390 FAX: 886-2-2910-1515 FAX: 886-2-2914-6299
Loading...