Ditch Witch 830 RT User Manual

830R/T
Operator’s Manual
CMW
®
Issue 1.0
053-2358
ORIGINAL INSTRUCTION
830R/T Operator’s Manual Overview - 1
Chapter Contents
Serial Number Location . . . . . . . . . . . . . . . . . . . . . . 2
Intended Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Bulleted Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Numbered Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
FCC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
IEC Safety Definitions . . . . . . . . . . . . . . . . . . . . . . . 4
CMW
Overview - 2 830R/T Operator’s Manual

Serial Number Location

Serial Number Location
Record serial numbers and date of purchase in spaces provided. Unit serial number is located as shown.
e16om014t.eps
Item
date of purchase: receiver serial number: transmitter serial number: accessory model & serial number: accessory model & serial number:
CMW
830R/T Operator’s Manual Overview - 3

Intended Use

Intended Use
The 830R receiver is designed to locate buried pipes and cables at an 83.0775 kHz frequency. Optional passive power and cathodic protection frequencies (60, 120, and 180 Hz in North America; 50, 100, and 150 Hz in other locations) are available.
The 830T transmitter places a single 83.0775 kHz signal on a target cable to be detected by an 830R receiver. The transmitter places a signal on the cable through either direct connection, inductive clamping, or induction (broadcast) modes.
The system is designed for operation in temperatures typically experienced in earth moving and construction work environments. Use in any other way is considered contrary to the intended use. The 830R/T system should be operated only by persons familiar with its particular characteristics and acquainted with the relevant safety procedures. The system should be serviced only by Ditch Witch repair centers.

About This Manual

This manual contains information for the proper use of this equipment. Cross references such as “See page 50” will direct you to detailed procedures.

Bulleted Lists

Bulleted lists provide helpful or important information or contain procedures that do not have to be performed in a specific order.

Numbered Lists

Numbered lists contain illustration callouts or list steps that must be performed in order.
CMW
Overview - 4 830R/T Operator’s Manual

FCC Statement

FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by The Charles Machine Works, Inc. could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the operator’s manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

IEC Safety Definitions

Hazardous voltage--electrical shock or equipment damage can result if transmitter is connected to live cable. Have qualified utility personnel disconnect both ends of cable before working.
IEC protection class II or double insulated electrical device is one which has been designed in such a way that it does not require a safety connection to electrical ground. In a device of this class, no single failure can result in dangerous voltage becoming exposed so that it might cause an electrical shock. This characteristic must be achieved without relying on a grounded metal casing.
CMW
830R/T Manual Foreword - 5

Foreword

This manual is an important part of your equipment. It provides safety information and operation instructions to help you use and maintain your Ditch Witch equipment.
Read this manual before using your equipment. Keep it with the equipment at all times for future reference. If you sell your equipment, be sure to give this manual to the new owner.
If you need a replacement copy, contact your Ditch Witch dealer. If you need assistance in locating a dealer, visit our website at www.ditchwitch.com or write to the following address:
The Charles Machine Works, Inc. Attn: Marketing Department PO Box 66 Perry, OK 73077-0066 USA
The descriptions and specifications in this manual are subject to change without notice. The Charles Machine Works, Inc. reserves the right to improve equipment. Some product improvements may have taken place after this manual was published. For the latest information on Ditch Witch equipment, see your Ditch Witch dealer.
Thank you for buying and using Ditch Witch equipment.
CMW
Foreword - 6 830R/T Series Operator’s Manual
830R/T
Operator’s Manual
Issue number 1.0/OM-12/10
Part number 053-2358
Copyright 2010
by The Charles Machine Works, Inc.
, Ditch Witch, CMW, AutoCrowd, Modularmatic, Jet Trac, Roto Witch, Subsite, Fluid Miser, Perma-Soil, Power Pipe, Super Witch, Super Witch II, Pierce Airrow, The Underground, and The Underground Authority Worldwide are registered trademarks of The Charles Machine Works, Inc.
CMW
830R/T Operator’s Manual Contents - 7

Contents

Overview
machine serial number, information about the type of work this machine is designed to perform, basic machine components, and how to use this manual
Foreword
part number, revision level, and publication date of this manual, and factory contact information
Safety
machine safety alerts and emergency procedures
Controls
machine controls and how to use them
Locate
procedures for locating active, passive and beacon signals
Locating Concepts
basic information for locating active, passive and beacon signals
Service
service intervals and instructions for this machine
1
5
9
15
27
35
43
Specifications
machine specifications including weights, measurements and power rating
Support
the warranty policy for this machine, and procedures for obtaining warranty consideration and training
47
51
CMW
Contents - 8 830R/T Operator’s Manual
CMW
830R/T Operator’s Manual Safety - 9

Safety

Chapter Contents
Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Safety Alert Classifications . . . . . . . . . . . . . . . . . . 11
Safety Alerts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
CMW
Safety - 10 830R/T Operator’s Manual

Guidelines

Guidelines
Follow these guidelines before operating any jobsite equipment:
Complete proper training and read operator’s manual before using equipment.
Contact your local One-Call (811 in USA) or the One-Call referral number (888-258-0808 in USA and
Canada) to have underground utilities located before working. Also contact any utilities that do not participate in the One-Call service.
Classify jobsite based on its hazards and use correct tools and machinery, safety equipment, and work
methods for jobsite.
Mark jobsite clearly and keep spectators away.
Wear personal protective equipment.
Review jobsite hazards, safety and emergency procedures, and individual responsibilities with all
personnel before work begins.
Replace missing or damaged safety signs.
Use equipment carefully. Stop operation and investigate anything that does not look or feel right.
Contact your equipment dealer if you have any question about operation, maintenance, or equipment
use.
CMW
830R/T Operator’s Manual Safety - 11

Safety Alert Classifications

Safety Alert Classifications
These classifications and the icons defined on the following pages work together to alert you to situations which could be harmful to you, jobsite bystanders or your equipment. When you see these words and icons in the book or on the unit, carefully read and follow all instructions. YOUR SAFETY IS AT STAKE.
Watch for the three safety alert levels: DANGER, WARNING and CAUTION. Learn what each level means.
indicates an imminently hazardous situation which, if not avoided, will result in death or
serious injury.
indicates a potentially hazardous situation which, if not avoided, could result in death or
serious injury.
indicates a potentially hazardous situation which, if not avoided, may result in minor or
moderate injury.
Watch for two other words: NOTICE and IMPORTANT. NOTICE can keep you from doing something that might damage the unit or someone's property. It can also
alert you against unsafe practices.
IMPORTANT can help you do a better job or make your job easier in some way.
CMW
Safety - 12 830R/T Operator’s Manual

Safety Alerts

Safety Alerts
Electric shock. Contacting electric lines will cause death or serious injury.
Know location of lines and stay away.
Jobsite hazards could cause death or serious injury. Use correct equipment and work methods. Use and maintain proper safety equipment.
Explosion possible. Serious injury or equipment damage could occur.
Follow directions carefully.
Incorrect procedures could result in death, injury, or property damage.
Learn to use equipment correctly.
Moving traffic - hazardous situation. Death or serious injury could result.
Avoid moving vehicles, wear high visibility clothing, post appropriate warning signs.
CMW
830R/T Operator’s Manual Safety - 13

Safety Alert

Safety Alert
Read and follow all safety precautions. Do not operate equipment unless you have completed proper training and have read the operator’s
manual. Check that equipment is in good condition and that test leads are clean and have no cracked insulation.
HIGH VOLTAGE. This device produces electric current that could cause death or serious injury. Electric shock may result if you touch the clips on the HV output cable. Use electrically insulating rubber gloves and proper procedures.
Electric shock or equipment damage can result if transmitter is connected to live cable. Have qualified utility personnel disconnect both ends of cable before working.
Turn off transmitter when connecting or moving ground probe. Jobsite hazards could cause death or serious injury. Use correct equipment and work methods. Use and
maintain proper safety equipment.
Explosion possible. Do not operate transmitter near explosive devices or blasting operations.
CMW
Safety - 14 830R/T Operator’s Manual
Safety Alert
CMW
830R/T Operator’s Manual Controls - 15

Controls

Chapter Contents
830R Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
830T Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
CMW
Controls - 16 830R/T Operator’s Manual

830R Receiver

830R Receiver

Controls

999
1
4
3
e16om002t.eps
1. Up arrow
2. Menu/Frequency
Item Description Notes
1. Up Arrow To scroll up in menu, press.
To increase gain in optional power mode, press.
c00ic089t.eps
3. Depth/Peak Verify/Down arrow
4. On/Off/Volume
2
CMW
Loading...
+ 38 hidden pages