DeLonghi PAC 360, Pinguino User Manual

2
Impor tant Information
When using electrical appliances, basic safety precautions should always be fol-
lowed, including the following:
Read all instructions.
To protect against fire, electrical shock and personal injury, do not immerse cord,
plug or appliance in water or other liquid.
Do not operate with a damaged cord or plug, or after the appliance malfunctions,
or has been damaged in any manner. Return the appliance to the nearest authori­zed De’ longhi service facility for examination, repair or adjustment.
The use of accessory attachments or spare parts is not recommended by the
appliance manufacturer. It may result in fire, electrical shock or personal injury.
Do not use outdoors.
Do not use the appliance for other than the intended use.
Do not place any strain on the power cord. Avoid twisting and/or tangling.
Ensure that outlet vent of exhaust hose is kept debris-clear and obstruction free.
Ensure that ventilation holes on the rear of the machine and front louvers are not
blocked.
The Pinguino should not be installed where the atmosphere could contain combusti-
ble gases.
Avoid using Pinguino in oily or sulphurous atmospheres or near sources of heat.
Wait at least 3 minutes before restarting, after the airconditioner has been switched
off or the thermostat setting changed.
Before moving the airconditioner, remove tank and empty water from collectiong
tray (see instructions for drainage at page 14).
Do not place hot or heavy objects on the appliance.
Clean air filter every week (see instructions at page 14).
Important: If you need to use an extension cord, please be sure to use a heavy duty
extension cord (minimum 14 gauge).
SAVE THESE INSTRUCTIONS
pac360U OK GB 24-04-2003 16:32 Pagina 2
3
ENGLISH
Dear user, We thank you for purchasing Pinguino airconditioner
and congratulate you on your wise choice. For optimal results please read this manual carefully
before installing or operating. We know that the Pinguino will keep your environment
pleasingly comfortable at all times. With best wishes
pac360U OK GB 24-04-2003 16:32 Pagina 3
4
Specifications
30.65
Water tank capacity pints
Power supply voltage V 115
60
10000
6.5
adjustable
97
R 22
yes
see rating label
22.05” (560)
28.74” (730)
15.35” (410)
Frequency Hz
Cooling capacity:
With water Btu
Current consumption A
Room thermostat Dimensions: width in.
height in. depth in.
Net weight lbs.
Refrigerant system (freon) Compressor protection
Freon charge lb. (gr)
OPTIMUM OPERATING RANGE
ROOM TEMPERATURE 21° - 35° C (70°F - 95°F)
ROOM HUMIDITY FACTOR
FREQUENCY
VOLTAGE
50% - 80% RH
POWER SUPPLY
60 HZ
115V
pac360U OK GB 24-04-2003 16:32 Pagina 4
5
ENGLISH
Air outlet grille
Air filter
Air intake grid
Exhaust hose compartment Power cord compartment Manual reset button
Castors
Castor stops
Water collecting tray
Water container compartment door
Control panel
Water container
Programmer (timer)
Handle
Drainage tube
Description of main features
pac360U OK GB 24-04-2003 16:32 Pagina 5
6
Illustrated accessor y list
DESCRIPTION SUPPLIED
Exhaust hose 1
Permanent wall vent 1
Caster stop 2
Descaling fluid 1
Window nozzle 1
Suction disc 2
ACCESSORY CHECK
Check that all parts listed in Table are included.
Window bracket + door bracket
1
Electrostatic filter 1
pac360U OK GB 24-04-2003 16:32 Pagina 6