Datasheet STTH12R06 Datasheet (ST)

Page 1
Turbo 2 ultrafast high voltage rectifier
Features
Ultrafast switching
Low reverse recovery current
Low thermal resistance
Package insulation voltage:
TO220AC ins: 2500 V TO-220FPAC: 2000 V
Description
The STTH12R06 uses ST Turbo 2 600V technology and is specially suited as a boost diode in continuous mode power factor corrections and hard switching conditions.
This device is also intended for use as a free wheeling diode in power supplies and other power switching applications.
RMS
DC
STTH12R06
K
A
K
TO-220AC
STTH12R06D
K
A
NC
2
PAK
D
STTH12R06G

Table 1. Device summary

STTH12R06FP
TO-220AC insulated
STTH12R06DIRG
TO-220FPAC
A
K
A
K
Symbol Value
I
F(AV)
V
RRM
(typ) 7 A
I
RM
T
j
V
(typ) 1.4 V
F
(max) 25 ns
t
rr
12 A
600 V
175 °C
February 2010 Doc ID 7973 Rev 4 1/11
www.st.com
11
Page 2
Characteristics STTH12R06

1 Characteristics

Table 2. Absolute ratings (limiting values)

Symbol Parameter Value Unit
V
Repetitive peak reverse voltage 600 V
RRM
TO-220AC / TO-220FPAC / D2PA K 3 0
I
F(RMS)
I
F(AV)
I
T

Table 3. Thermal resistance

Forward rms current
TO-220AC ins. 24
2
TO-220AC / D
Average forward current δ = 0.5
TO-220AC ins. T
Surge non repetitive forward current tp = 10 ms sinusoidal 100 A
FSM
Storage temperature range -65 to + 175 °C
stg
Maximum operating junction temperature 175 °C
T
j
PAK Tc = 125 °C
= 50 °C
c
= 80 °C
c
12 ATO-220FPAC T
Symbol Parameter Value (max) Unit
2
PAK 1.7
°C/WTO-220FPAC 4.4
R
th(j-c)
TO-220AC / D
Junction to case
TO-220AC ins. 3.3
A

Table 4. Static electrical characteristics

Symbol Parameter Test conditions Min. Typ. Max. Unit
I
Reverse leakage current
R
V
Forward voltage drop
F
= 25 °C
j
= 125 °C 50 600
T
j
T
= 25 °C
j
Tj = 125 °C 1.4 1.8
= V
V
R
= 12 A
I
F
RRM
45
2.9
T
To evaluate the conduction losses use the following equation: P = 1.16 x I
F(AV)
+ 0.053 I
F2(RMS)
µA
V
2/11 Doc ID 7973 Rev 4
Page 3
STTH12R06 Characteristics

Table 5. Dynamic Characteristics

Symbol Parameter Test conditions Min. Typ. Max. Unit
= 0.5 A, Irr = 0.25 A,
I
F
IR = 1 A
Reverse recovery time Tj = 25 °C
t
rr
= 1 A,
I
F
/dt = -50 A/µs,
dI
F
VR = 30 V
Reverse recovery current
I
RM
S factor Softness factor 0.2
Q
Reverse recovery charges 180 nC
rr
Forward recovery time
t
fr
V
Forward recovery voltage 5.5 V
FP
T
= 125 °C
j
= 25 °C
T
j
Figure 1. Conduction losses versus
average current
P(W)
30
δ = 0.05
25
20
15
10
5
0
0123456789101112131415
δ = 0.1
δ = 0.2
I (A)
F(AV)
δ = 0.5
δ
δ = 1
=tp/T
Figure 3. Relative variation of thermal
impedance junction to case versus pulse duration
Z/R
th(j-c) th(j-c)
1.0
0.9
TO-220AC TO6220AC Ins
0.8
D2PAK
0.7
0.6
0.5
0.4
Single pulse
0.3
0.2
0.1
0.0
1.E-03 1.E-02 1.E-01 1.E+00
t (s)
p
= 12 A, VR = 400 V,
I
F
dIF/dt = -200 A/µs
I
= 12 A, dIF/dt = 96
F
A/µs,
= 1.1 x V
V
FR
Figure 2. Forward voltage drop versus
T
tp
Figure 4. Relative variation of thermal
Fmax
forward current
I (A)
FM
120
110
100
90
80
70
60
50
40
30
20
10
0
0123456
(maximum values)
T=125°C
j
(typical values)
T=125°C
j
impedance junction to case versus pulse duration
Z/R
th(j-c) th(j-c)
1.0
0.9
TO-220FPAC
0.8
0.7
0.6
0.5
0.4
0.3
0.2
Single pulse
0.1
0.0
1.E-03 1.E-02 1.E-01 1.E+00 1.E+01
t (s)
p
7.0 8.4 A
V (V)
FM
25
ns
45
200 ns
T=25°C
j
(maximum values)
Doc ID 7973 Rev 4 3/11
Page 4
Characteristics STTH12R06
Figure 5. Peak reverse recovery current
versus dI
I (A)
RM
26
V =400V
R
24
T=125°C
j
22
20
18
16
14
12
10
8
6
4
2
0
0 200 400 600 800 1000
I =0.25 x I
F F(AV)
/dt (typical values)
F
I =2 x I
F F(AV)
I=I
F F(AV)
dI /dt(A/µs)
F
F F(AV)
I =0.5 x I
Figure 7. Reverse recovery charges
versus dI
Q (nC)
rr
500
V =400V
R
450
T=125°C
j
400
350
300
250
200
150
100
50
0
0 200 400 600 800 1000
/dt (typical values)
F
I =2 x I
F F(AV)
I=I
F F(AV)
I =0.5 x I
F F(AV)
dI /dt(A/µs)
F
Figure 9. Relative variations of dynamic
parameters versus junction temperature
2.50
2.25
2.00
1.75
1.50
1.25
1.00
0.75
0.50
0.25
0.00
25 50 75 100 125
I
RM
Q
RR
T (°C)
j
S factor
I=I
F F(AV)
V =400V
R
Reference:T =125°C
j
Figure 6. Reverse recovery time versus
dIF/dt (typical values)
t (ns)
rr
80
70
60
50
40
30
20
10
0
0 200 400 600 800 1000
I =2 x I
F F(AV)
I=I
F F(AV)
I =0.5 x I
F F(AV)
dI /dt(A/µs)
F
V =400V
R
T=125°C
j
Figure 8. Softness factor versus
dIF/dt (typical values)
S factor
0.50
I 2 x I
F F(AV)
V =400V
R
T=125°C
j
0.45
0.40
0.35
0.30
0.25
0.20
0.15
0.10
0 200 400 600 800 1000
dI /dt(A/µs)
F
Figure 10. Transient peak forward voltage
versus dI
V (V)
FP
12
I=I
F F(AV)
11
T=125°C
j
10
9
8
7
6
5
4
3
2
1
0
0 100 200 300 400 500
/dt (typical values)
F
dI /dt(A/µs)
F
4/11 Doc ID 7973 Rev 4
Page 5
STTH12R06 Characteristics
Figure 11. Forward recovery time versus
dI
/dt (typical values)
F
Figure 12. Junction capacitance versus
reverse voltage applied (typical values)
t (ns)
fr
180
160
140
120
100
80
60
40
20
0
0 100 200 300 400 500
dI /dt(A/µs)
F
I=I
F F(AV)
V =1.1 x V max.
FR F
T=125°C
j
C(pF)
100
V (V)
10
1 10 100 1000
R

Figure 13. Thermal resistance junction to ambient versus copper surface under tab

R (°C/W)
th(j-a)
70
60
50
40
30
20
10
0
0 5 10 15 20 25 30 35 40
Epoxy printed circuit board, FR4 copper thickness = 35 µm
SCu(cm²)
F=1MHz
V =30mV
OSC RMS
T=25°C
j
Doc ID 7973 Rev 4 5/11
Page 6
Package information STTH12R06

2 Package information

Epoxy meets UL94, V0
Cooling method: by conduction (C)
Recommended torque value: 0.4 to 0.6 N·m
In order to meet environmental requirements, ST offers these devices in different grades of ECOPACK specifications, grade definitions and product status are available at: www.st.com ECOPACK

Table 6. TO-220AC dimensions

®
packages, depending on their level of environmental compliance. ECOPACK®
®
is an ST trademark.
.
Dimensions
Ref.
Millimeters Inches
Min. Max. Min. Max.
A 4.40 4.60 0.173 0.181
H2
Ø I
A
C
C 1.23 1.32 0.048 0.051
D 2.40 2.72 0.094 0.107
L5
L6
L2
L7
E 0.49 0.70 0.019 0.027
F 0.61 0.88 0.024 0.034
F1 1.14 1.70 0.044 0.066
G 4.95 5.15 0.194 0.202
F1
L9
L4
F
D
H2 10.00 10.40 0.393 0.409
L2 16.40 typ. 0.645 typ.
L4 13.00 14.00 0.511 0.551
M
E
L5 2.65 2.95 0.104 0.116
L6 15.25 15.75 0.600 0.620
G
L7 6.20 6.60 0.244 0.259
6/11 Doc ID 7973 Rev 4
L9 3.50 3.93 0.137 0.154
M 2.6 typ. 0.102 typ.
Dia. I 3.75 3.85 0.147 0.151
Page 7
STTH12R06 Package information

Table 7. TO-220FPAC dimensions

Dimensions
Ref.
Millimeters Inches
Min. Max. Min. Max.
A 4.4 4.6 0.173 0.181
A
H
B
B 2.5 2.7 0.098 0.106
D 2.5 2.75 0.098 0.108
Dia
E 0.45 0.70 0.018 0.027
F 0.75 1 0.030 0.039
L6
L2
L3
L5
F1
L4
D
F1 1.15 1.70 0.045 0.067
L7
G 4.95 5.20 0.195 0.205
G1 2.4 2.7 0.094 0.106
H 10 10.4 0.393 0.409
L2 16 Typ. 0.63 Typ.
L3 28.6 30.6 1.126 1.205
F
G1
E
L4 9.8 10.6 0.386 0.417
L5 2.9 3.6 0.114 0.142
G
L6 15.9 16.4 0.626 0.646
L7 9.00 9.30 0.354 0.366
Dia. 3.00 3.20 0.118 0.126
Doc ID 7973 Rev 4 7/11
Page 8
Package information STTH12R06

Table 8. TO-220AC (nins. and ins. 20-up) dimensions

Dimensions
Ref.
Millimeters Inches
Min. Typ. Max. Min. Typ. Max.
A 15.20 15.90 0.598 0.625
a1 3.75 0.147
a2 13.00 14.00 0.511 0.551
B 10.00 10.40 0.393 0.409
F
Ø I
B
L
C
b2
b1 0.61 0.88 0.024 0.034
A
I4
b2 1.23 1.32 0.048 0.051
C 4.40 4.60 0.173 0.181
a1
l2
a2
c2
c1 0.49 0.70 0.019 0.027
c2 2.40 2.72 0.094 0.107
e 4.80 5.40 0.189 0.212
b1
e
M
F 6.20 6.60 0.244 0.259
c1
ØI 3.75 3.85 0.147 0.151
I4 15.80 16.40 16.80 0.622 0.646 0.661
L 2.65 2.95 0.104 0.116
l2 1.14 1.70 0.044 0.066
M2.60 0.102
8/11 Doc ID 7973 Rev 4
Page 9
STTH12R06 Package information
Table 9. D
L2
L
L3
2
PAK dimensions
E
A1
B2
B
G
* FLAT ZONE NO LESSTHAN 2mm
Dimensions
Ref.
Millimeters Inches
Min. Max. Min. Max.
A 4.40 4.60 0.173 0.181
A
A1 2.49 2.69 0.098 0.106
C2
A2 0.03 0.23 0.001 0.009
B 0.70 0.93 0.027 0.037
D
B2 1.14 1.70 0.045 0.067
C 0.45 0.60 0.017 0.024
C2 1.23 1.36 0.048 0.054
C
R
D 8.95 9.35 0.352 0.368
E 10.00 10.40 0.393 0.409
A2
G 4.88 5.28 0.192 0.208
L 15.00 15.85 0.590 0.624
M
*
V2
L2 1.27 1.40 0.050 0.055
L3 1.40 1.75 0.055 0.069
M 2.40 3.20 0.094 0.126

Figure 14. Footprint (dimensions in mm)

16.90
10.30
8.90
R 0.40 typ. 0.016 typ.
V2
5.08
1.30
3.70
Doc ID 7973 Rev 4 9/11
Page 10
Ordering information STTH12R06

3 Ordering information

Table 10. Ordering information

Order code Marking Package Weight Base qty
STTH12R06D STTH12R06D TO-220AC 1.90 g 50 Tube
STTH12R06G STTH12R06G D
STTH12R06G-TR STTH12R06G D
STTH12R06FP STTH12R06FP TO-220FPAC 1.70 g 50 Tube
STTH12R06DIRG STTH12R06DI TO-220AC ins. 1.86 g 50 Tube

4 Revision history

Table 11. Document revision history

Date Revision Changes
January-2002 1 Initial release.
18-Oct-2004 2 D2PAK and TO-220AC insulated packages added
10-Aug-2006 3
15-Feb-2010 4 Corrected typographical error in order codes in Ta b le 1 0.
Delivery
mode
2
PAK 1.48 g 50 Tube
2
PAK 1.48 g 1000 Tape and reel
Reformatted to current standards. Added package insulation voltages on page 1
10/11 Doc ID 7973 Rev 4
Page 11
STTH12R06
Please Read Carefully:
Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notice.
All ST products are sold pursuant to ST’s terms and conditions of sale.
Purchasers are solely responsible for the choice, selection and use of the ST products and services described herein, and ST assumes no liability whatsoever relating to the choice, selection or use of the ST products and services described herein.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted under this document. If any part of this document refers to any third party products or services it shall not be deemed a license grant by ST for the use of such third party products or services, or any intellectual property contained therein or considered as a warranty covering the use in any manner whatsoever of such third party products or services or any intellectual property contained therein.
UNLESS OTHERWISE SET FORTH IN ST’S TERMS AND CONDITIONS OF SALE ST DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY WITH RESPECT TO THE USE AND/OR SALE OF ST PRODUCTS INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION), OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.
UNLESS EXPRESSLY APPROVED IN WRITING BY AN AUTHORIZED ST REPRESENTATIVE, ST PRODUCTS ARE NOT RECOMMENDED, AUTHORIZED OR WARRANTED FOR USE IN MILITARY, AIR CRAFT, SPACE, LIFE SAVING, OR LIFE SUSTAINING APPLICATIONS, NOR IN PRODUCTS OR SYSTEMS WHERE FAILURE OR MALFUNCTION MAY RESULT IN PERSONAL INJURY, DEATH, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE. ST PRODUCTS WHICH ARE NOT SPECIFIED AS "AUTOMOTIVE GRADE" MAY ONLY BE USED IN AUTOMOTIVE APPLICATIONS AT USER’S OWN RISK.
Resale of ST products with provisions different from the statements and/or technical features set forth in this document shall immediately void any warranty granted by ST for the ST product or service described herein and shall not create or extend in any manner whatsoever, any liability of ST.
ST and the ST logo are trademarks or registered trademarks of ST in various countries.
Information in this document supersedes and replaces all information previously supplied.
The ST logo is a registered trademark of STMicroelectronics. All other names are the property of their respective owners.
© 2010 STMicroelectronics - All rights reserved
STMicroelectronics group of companies
Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan -
Malaysia - Malta - Morocco - Philippines - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States of America
www.st.com
Doc ID 7973 Rev 4 11/11
Loading...