GENERAL INTRODUCTION
The SK9001 unit is a stand-alone control unit with an integral reader which is used to manage the electronic keys SK9050, SK9051 and SK9052. It is used to control access to a door fitted with an electronic lock or an automatic device.
It is supplied ready for use. It is initialised by swiping the first token programmed with the SIMPLEKEY ADVANCED software over the unused unit. The other tokens are then saved automatically in the memory when they are first swiped.
Layout of the unit
The card is made up of:
- a switch used to access the programming
- three push buttons that are used to affect the parameters
- the three LED’s that show the statuses of the switchboard
- connection terminals
- a J5 firmware update connector
Opening time can be adjusted from between 1 and 99 seconds.
Description of terminals
AL: Power supply 12 - 24 V ac/dc J1: RS485 network J2: NO/NC relay output J3: Exit push button + alarm J4: Integral reader,
PROGRAMMING
The S3 switch is used to switch between programming modes.
S3 in “0” position Operating mode
S3 in “ON” position Programming mode
N.B.:
In programming mode the L2 LED and the reader LED flash rapidly.
You must go back to operating mode for the unit to manage access.
Setting the opening timer
- Turn switch S3 to “ON” (Programming)
- Press button S1 several times to adjust the time units (one press per second). Once S3 has switched back to operating mode a double confirmation beep will validate this for you.
The minimum timing setting is 1 second. The maximum timing setting is 99 seconds.
The unit is supplied with a 5 second opening time set by the factory.
User token management
The tokens must be programmed using the SIMPLEKEY ADVANCED software contained in the SK9091 kit so that they can work on the SK9001 unit. Refer to the software programming instructions.
1.
Initialisation
The SK9001 is supplied blank and must be initialised. To do this, you just have to plug it in, turn it on and swipe one of the programmed token to the reader. The unit will remain in PRG mode for few seconds ( Green and Red LEDs flushing simultaneously ), because the units is recoding Building Code and Site Code of the token. Once back to normal operating mode, all tokens of the same Building will open the door without any other programming and their parameters will be stored automatically as they are first swiped.
N.B. Multi-Building Programming:
Typically for situation with Main and Secondary entrances, for Main entrance Reader it is possible to program and authorise tokens from several Buildings ( Max 30 ). To do this we simply have to swipe, one after the other, tokens from different Buildings, while the unit is in PRG mode for Initialisation. In this way the unit will be programmed with more Building Codes and all tokens of those Buildings can open the door.
EN
FR
WARNINGS
• Install the equipment by carefully following the instructions given by the manufacturer and in compliance with the standards in force.
• All equipment must only be used for the purposes for which it was designed. The COMELIT GROUP s.p.a. disclaims all responsibility in the event of misuse of the equipment, for modifications made by other people for whatever reason and for using non-original accessories and materials.
• All the products comply with the requirements of Directive 2006/95/CE (which replaced Directive 73/23/EEC and subsequent amendments). This is proven by the CE mark on the products.
• Do not put the riser wires near the supply cables (230/400 v)
AVERTISSEMENTS
• Effectuer lʼinstallation en suivant scrupuleusement les instructions fournies par le constructeur et conformément aux normes en vigueur.
• Tous les appareils doivent être strictement destinés à lʼemploi pour lesquels ils ont été conçus. La société COMELIT GROUP s.p.a. décline toute responsabilité en cas de mauvais usage des appareils, pour des modifications effectuées par dʼautres personnes pour nʼimporte quelle raison et pour lʼutilisation dʼaccessoires et matériaux non dʼorigine.
• Tous les produits sont conformes aux prescriptions de la directive 2006/95/CE (qui remplace la directive 73/23/CEE et amendements successifs). Cela est attesté par la présence du marquage CE sur les produits.
• Eviter de placer les fils de montants à proximité des câbles dʼalimentation (230/400 v)
NL
ES
WAARSCHUWING
• Volg de instructies van de fabrikant nauwkeurig en installeer de materialen volgens de plaatselijk geldende normen.
• Alle componenten mogen alleen gebruikt worden voor de doeleinden waarvoor ze zijn ontworpen. COMELIT GROUP s.p.a. is niet verantwoordelijk voor oneigenlijk gebruik van de apparatuur, voor wijzigingen die om welke reden dan ook door derden zijn aangebracht, en voor het gebruik van accessoires en materialen die niet door de fabrikant zijn aangeleverd.
• Alle producten voldoen aan de eisen van de richtlijn 2006/95/EG (die de richtlijn 73/23/EEG en latere wijzigingen vervangt). Dit wordt bevestigd door het CE-label op de producten.
• Monteer de aders van de stamleiding niet in de nabijheid van voedingskabels (230/400V).
ADVERTENCIAS
• La instalación se ha de efectuar en conformidad con las normas vigentes, siguiendo atentamente las instrucciones suministradas por el fabricante.
• Todos los aparatos deben estar destinados exclusivamente al uso para el cual han sido construidos. COMELIT GROUP s.p.a. declina toda responsabilidad por el uso impropio de los aparatos, por cambios efectuados por terceros por cualquier motivo o finalidad y por el uso de accesorios y materiales no originales.
• Todos los productos son conformes a los requisitos de las Directivas 2006/95/CE (que sustituye la Directiva 73/23/CEE y sucesivas enmiendas) como demuestra la presencia de la marca CE en ellos.
• No poner los cables de la columna montante cerca de los cables de alimentación (230/400V).
FT SK9001
FT SK9001
3
ENGLISH
2. Adding a token
To add a token later you just have to programme it into the SIMPLEKEY software and swipe it past the reader. Its parameters will be recorded automatically.
3.
Replacing a token
To delete a token you just have to select its location in the SIMPLEKEY software and re-programme a new token. Its parameters will automatically replace the old one when it is first used.
4.
Modifying a tokenʼs parameters
To modify a token’s parameters you just have to select it from 7the SIMPLEKEY software and re-programme it. Its parameters will be updated automatically when it is first used.
5.
Complete reset
- Turn switch S3 to “ON” (Programming)
- To reset to zero completely, press S2 for 15 seconds. The L2 LED will go out and after 15 seconds the L3 LED will come on. The unit has been totally reset to zero.
- Switching back to operating mode. (A double beep tells you that the unit has been reset)
Complete resetting enables the initialisation process:
- the password to access the switchboard is “0000”.
- Deleting user tokens.
6.
Setting the date and time
To work properly the SK9001 unit’s internal clock must be set correctly. This is set in the factory to GMT time (universal time) and will be adjusted automatically to the corresponding time zone in the place it is being used when it is initialised (first key swiped). If necessary, it is, however, possible to set the time and date manually using the SK9093 software supplied separately. To do this you just have to connect to the unit using the cable supplied with the kit and launch the program.
- Click on “Clock” and then follow the instructions to change the setting.
- Other functions are possible (changing the password, resetting the unit etc.). Refer to the software instructions.
ADVANCED FUNCTIONS
“Main SITE Door” mode
The SK9001 unit can be used to control the Main Door which may be opened by all keys on a site, not only many Buildings as Multi-Building programming ( e.g. Access to residence, Gated Community etc … ) To initialise a SK9001 unit in “Main SITE Door” mode, press S2 button on the unit for 5 seconds, until you hear a beep. In this moment, all tokens of the same site of the 1st swiped one will open the Main Site door It is always possible to switch back to normal mode ( Building or Multi-Building Door ) By pressing S2 button again for 5 seconds, until you hear a double beep (which indicates that you are back to normal operation mode)
Event management
The SK9001 unit stores the last 1500 events in its memory (access authorised, access refused, cancelled token etc.). It is possible to retrieve them using a transfer token (ref. SK9053) supplied separately. After initialising it with the SIMPLEKEY ADVANCED software, place the transfer token in front of the reader until the red LED stops flashing. Once saved, you just have to put it in the encoder linked to the micro-computer and follow the software instructions to transfer the events in the database.
Alarm
The SK9001 unit has alarm functions which may be used to trigger an alarm device. This is how to use it. When the alarm input is triggered by a contact opening, the output is activated. This function is disabled for 1 minute each time access by token or an exit push button is validated. This allows the alarm to be triggered immediately if the door is forced or after 1 minute if the door is still open after an authorised entry.
When Alarm Function it is used, JP1 jumper on the unit must be removed
N.B.: It is not necessary to wire the unit alarm inputs and outputs if this function is not
used.
Lift mode
The SK9001 unit can be used to control the SK9071 relay boxes in order to control the lift floor commands.
The function must have been enabled in the SIMPLEKEY software and the tokens coded after selecting the authorised floors.
It is possible to connect up to 10 SK9001 boxes to one unit which enables 100 floors to be controlled.
Network Mode
It is possible to network the various system units in order to take advantage of the following functions from the management micro-computer:
• Modifying unit parameters
• Setting the date and time
• Retrieving events automatically or on command
• Remote opening command
• Immediate deletion of a lost token
It is possible to network up to 255 units in one system. 3 types of network are possible:
• An RS485 wired network using a USB converter ref. SK9073 (one per system) - a maximum of 32 units. It is vital to record on the unit the same logical address as the one recorded in the software. To do this use the S1 push button giving the pulse number corresponding to the address (between 1 and 32) then validate it by holding the S1 push button down for 5 seconds.
• A TCP/IP Ethernet network by adding the SK9072 converter to each unit - a maximum of 254 units. Keep the default value of the logical unit address.
• Mixed network: TCP/IP Ethernet to several branches (with the SK9072 converter) then wired RS485 cabling to each branch - a maximum of 32 units per branch, 255 units in total. The units must be addressed from 1 - 32 on each branch.
For detailed use of the functions please refer to the SIMPLEKEY ADVANCED software instructions.
Normal working of the unit
When the unit is in normal Operating Mode, 2 LEDs inside the units are flushing and the Red LED on the reader is ON. If the unit is not working properly, these LEDs are giving different indications. In this case turn the power OFF and then ON again. If this does not work, please contact our after sales service department
Technical characteristics
• Opening time can be adjusted from between 1 and 99 seconds.
• Output via dry contact max. 5A at 250 VAC
• Power consumption: 70 mA when idle, 160 mA when relay active
• Operating temperature: -10°C - +55°C
• Operating voltage: 12 - 24 V ac/dc
• Dimensions (H X L X D): 62 x 88 x 23 mm
PRESENTATION GENERALE
Le module SK9001 est une unité de contrôle autonome avec antenne de lecture intégré qui permet de gérer les clés électroniques SK9050, SK9051 et SK9052. Il permet de contrôler l’accès à une porte équipée d’une serrure électrique ou un dispositif automatique.
Il est Livré prêt à fonctionner. L’initialisation est réalisée par présentation du premier badge programmé à l’aide du logiciel SIMPLEKEY ADVANCED sur la centrale vierge ; Les autres badges sont ensuite mémorisés automatiquement en mémoire lors de leur premier passage.
Présentation du module
La carte est composée :
- d’un switch permettant d’accéder à la programmation
- de trois poussoirs permettant d’agir sur les paramètres
- de trois voyants led rouges indiquant les états de la centrale
- de borniers de raccordement
- d’un connecteur de mise à jour du firmware J5
Description des bornes
AL : Alimentation 12 à 30 V cc ou ca J1 : Réseau RS485 J2 : Sortie relais NO/NF J3 : poussoir de sortie + alarme J4 : antenne intégrée
PROGRAMMATION
Le switch S3 permet de basculer en mode de programmation
S3 en position "0" Mode fonctionnement
S3 en position "ON" Mode programmation
Nota :
En mode programmation le voyant L2 ainsi que celui de la tête de lecture
clignotent rapidement.
Pour que la centrale puisse gérer les accès, il faut impérativement revenir en mode fonctionnement
Réglage de la temporisation dʼouverture
- Mettre le switch S3 sur "ON" (Programmation)
- Appuyer plusieurs fois sur le bouton S1 pour régler les unités de la temporisation (un appui par seconde). Une fois S3 rebasculé en mode fonctionnement, un double bip de confirmation vous informe de la validation.
La valeur minimum de la temporisation est de 1 seconde. La valeur maximum de la temporisation est de 99 secondes.
Le module est livré avec un réglage d'usine de temporisation dʼouverture de 5 secondes.
Gestion des badges résidants
Il est nécessaire de programmer les badges à l’aide du logiciel SIMPLEKEY ADVANCED contenu dans le kit SK9091 pour qu’ils puissent fonctionner sur le module SK9001. Reportez-vous à la notice du logiciel pour la programmation.
1.
Initialisation
Le SK9001 est fourni vierge et doit être initialisé. Pour faire cela vous devez simplement le connecter à l’alimentation et présenter au lecteur un des badges programmés. Le module restera en Programmation pendant quelques secondes (la LED rouge et elle verte clignoteront au même temps), car le module est en train de recoder le Code Immeuble et le Code Installation.
GROUP S.P.A.
FT SK9001
4
FRANÇAIS
Une fois revenu au Mode de Fonctionnement normal, tous le badges du même immeuble ouvrira la porte sans autre programmation et leur paramètres seront mémorisés automatiquement lors de leur première présentation. N.B. Programmation Multi - Immeubles: Dans une situation assez typique avec une Entrée Principale et des Entrées Secondaires il est possible de programmer et autoriser des badges appartenant à des immeubles différents (30 Maximum). Pour faire cela on doit simplement présenter au module, un après l’autre, les badges provenant d’immeubles différents tandis que le module est en Programmation pour son Initialisation. De cette façon le module sera programmé avec plusieurs Codes Immeuble, et tous les badges de ces immeubles pourront ouvrir la Porte.
2.
Ajout d'un badge
Pour ajouter ultérieurement un badge, il suffit de le programmer sur le logiciel SIMPLEKEY et de le présenter devant l’antenne de lecture. Ses paramètres seront automatiquement enregistrés.
3.
Remplacement dʼun badge
Pour supprimer un badge, il suffit de sélectionner son emplacement sur le logiciel SIMPLEKEY et de reprogrammer un nouveau badge. Ses paramètres viendront automatiquement remplacer l’ancien lors de sa première utilisation.
4.
Modification des paramêtres dʼun badge
Pour modifier les paramètres d’un badge, il suffit de le sélectionner sur le logiciel SIMPLEKEY et de le reprogrammer. Ses paramètres seront automatiquement mis à jour lors de sa prochaine utilisation.
5.
Réinitialisation des données
- Mettre le switch S3 sur "ON" (Programmation)
- Pour la remise à zéro totale, appuyer sur S2 pendant 15 secondes, le voyant L2
s’éteint, après 15 secondes le voyant L3 s’allume. La remise à zéro totale est effectuée.
- Rebasculer en mode fonctionnement. (Un double bip vous informe de la remise à
zéro)
La remise à zéro permet lʼinitialisation :
- mot de passe dʼaccès à la centrale à « 0000 ».
- suppression des badges utilisateurs.
3.
Réglage de la date et lʼheure
Pour fonctionner correctement, l’horloge interne du module SK9001 doit impérativement être correctement réglé. Celui-ci est réglé en usine à l’heure GMT (temps universel) et sera automatiquement ajusté sur le fuseau correspondant au lieu d’utilisation au moment de l’initialisation (présentation de la première clé). En cas de nécessité, il est toutefois possible d’agir manuellement sur le réglage de la date et l’heure à l’aide du logiciel SK9093 fourni séparément. Pour cela, il suffit de se connecter à la centrale à l’aide du cordon livré avec le kit et de lancer le programme.
- Cliquez sur « horloge » puis suivez les instructions pour modifier le réglage.
- D’autres fonctions sont possibles (changement du mot de passe, réinitialisation du
module, etc.) reportez-vous aux instructions du logiciel.
FONCTIONS AVANCÉES
Mode « Porte Principale »
Le module SK9001 peut être utilisé pour gérer la Porte Principale, qui peut être ouverte par tous les clés sur une installation, et pas seulement plusieurs Immeubles comme la programmation Multi – Immeubles (ex. Accès à une résidence, etc. ) Pour initialiser un module SK9001 en Mode « Porte Principale » , appuyez sur le bouton S2 du module pendant 5 secondes, jusqu’à ce que vous entendez un bip. Maintenant tous les badges appartenant à la même installation du premier badge présenté ouvriront la Porte Principale. Il est toujours possible de basculer au mode normal (Immeuble ou Multi – Immeubles) en appuyant sur le bouton S2 de nouveau pendant 5 secondes, jusqu’à ce que vous entendez un double bip (qui indique que le module est de nouveau en Mode de Fonctionnement normal).
Gestion des événements
Le module SK9001 garde en mémoire les 1500 derniers événements (accès autorisé, accès refusé, badge annulé, etc.) Il est possible de les récupérer à l’aide d’un badge de transfert ref. SK9053 fourni séparément. Après l’avoir initialisé depuis le logiciel SIMPLEKEY ADVANCED, placez le badge de transfert devant l’antenne de lecture jusqu’à ce que la led rouge arrête de clignoter. Une fois chargé, il suffit de le poser sur l’encodeur relié au micro-ordinateur et suivre les instructions du logiciel pour transférer les événements sur la base de donnée.
FT SK9001
FT SK9001
5
FRANÇAIS
Alarme
Le module SK9001 dispose de fonctions d’alarme qui peuvent être utilisées pour déclencher un dispositif d’alerte. L’utilisation est la suivante : lorsque l’entrée d’alarme est actionnée par l’ouverture d’un contact, la sortie est activée. Cette fonction est désactivée durant 1 minute à chaque fois qu’un accès par badge ou poussoir de sortie est validé. Ceci permet de déclencher l’alerte immédiatement en cas de porte forcée ou après 1 minute lorsque la porte est restée ouverte après un passage autorisé.
Quand on utilise la Fonction Alarme, le jumper JP1 du module doit être enlevé.
Nota : il n’est pas nécessaire de câbler les entrées et sorties alarme du module si
cette fonction n’est pas utilisée.
Mode ascenseur
Le module SK9001 peut être utilisé pour commander les boîtiers relais SK9071 afin de contrôler les commandes d’étages d’un ascenseur.
La fonction doit avoir été activé sur le logiciel SIMPLEKEY et les badges encodés après avoir sélectionné les étages autorisés.
Il est possible de raccorder jusqu’à 10 boîtiers SK9071 sur un module, permettant de contrôler 100 étages
Mode connecté
Il est possible de raccorder en réseau les différents modules d’une installation afin de bénéficier des fonctions suivantes depuis le micro-ordinateur de gestion :
• Modification des paramètres des modules
• Réglage de la date et l’heure
• Récupération automatique ou sur ordre des événements
• Commande d’ouverture distante
• Suppression immédiate d’un badge perdu
Il est possible de raccorder jusqu’à 255 modules en réseau sur une installation. 3 types de réseaux sont possibles :
• Réseau filaire RS485 à l’aide du convertisseur USB ref. SK9073 (un par installation) – 32 modules maximum Il est indispensable de renseigner sur le module l’adresse logique correspondant à celle inscrite sur le logiciel. Pour ce faire, utilisez le poussoir S1 en donnant le nombre d’impulsion correspondant à l’adresse. (de 1 à 32) puis validez en maintenant le poussoir S1 pendant 5 secondes.
• Réseau Ethernet TCP/IP en ajoutant sur chaque module le convertisseur SK9072 ­254 modules maximum Laisser l’adresse logique du module sur sa valeur par défaut
• Réseau mixte : Ethernet TCP/IP sur plusieurs dérivations (avec le convertisseur SK9072) puis câblage filaire RS485 sur chaque dérivation - 32 modules maximum par dérivation, 255 modules au total Les modules doivent être adressés de 1 à 32 sur chaque dérivation.
Pour l’utilisation détaillée des fonctions, reportez-vous aux instructions du logiciel SIMPLEKEY ADVANCED
Fonctionnement normal du module autonome
Quand le module est en Mode de Fonctionnement normale, 2 LED à l’intérieur du module clignotent et la LED Rouge sur le lecteur est allumée. Si le module ne fonctionne pas correctement, ces LEDs donneront des indications différentes. En ce cas éteignez l’alimentation et après allumez-la de nouveau. Si cela ne fonctionne pas, veuillez s’il –vous - plaît contacter notre Service Après - Ventes.
Caractéristiques techniques
• Réglage de la temporisation d’ouverture entre 1 et 99 secondes.
• Sortie par contact sec maxi 5A sous 250 VAC
• Consommation : 70 mA au repos, 160 mA relais actif
• Température de fonctionnement : -10°c à +55°c
• Tension de fonctionnement : 12 à 24 V cc ou ca
• Dimension (h x l x p) : 62 x 88 x 23 mm