Citizen CH-656C User Manual

English
INSTRUCTION MANUAL
FOR
MODEL CH-656C
M
- Eng 1 -
Español
Português
Italiano
Deutch
Français
CLEANING METHOD OF CUFF
After cleaning the cuff with a neutral detergent, lightly rinse it with water and let it dry in the air. Hard rubbing or washing in a washing machine
GENERAL REMARKS
General Remarks on blood pressure measurement
• If the cuff is to be deflated quickly, depress “POWER” switch.
• The attached cuff is suited for a wrist circum­stance of 13.5cm to 19.5cm.
• When attaching the cuff, the body of a blood pressure monitor should be placed on the in­side of your wrist.
• Self measurement is no therapy! In no case may you change the dosage of medication pre­scribed by your physician.
• In operation for blood pressure measurement, you should urinate and should remain relatively still for 10 to 15 minutes prior to measurement.
• Exercise, eating and drinking, smoking, etc., prior to measurement may affect the results.
will cause air leakage. Also, be careful not to get water into the air hose.
• The blood pressure varies constantly throughout the day. Measurement should be made regularly at the same time each day.
• Do NOT be impressed by the results of one measurement. Keep a record of blood pressure variations. Many readings tell a story.
• Emotional stress may tend to cause pressure to rise.
• This Product should not be used to monitor cardiac arrhythmia.
mmHg
89
85
Diastolic Blood Pressure
HIGH NORMAL
NORMAL
Systolic Blood Pressure
HYPERTENSION
130 139
- Eng 2 -
mmHg
For proper measurement of blood pressure
• Take a deep breath five or six time and then relax before measuring blood pressure. If you are tense when taking the measurement, you will not get a valid reading.
• Blood pressure will be elevated when you are in a worrisome or irritated state, suffering from lack of sleep or constipation, or after exercise or a meal.
• Putting on the cuff is one of the most impor­tant tasks for ensuring proper measurement of blood pressure. wrist and tighten it so that one finger may be inserted between the cuff and wrist.
• Do NOT measure blood pressure after bathing or drinking.
Wind the cuff around the
• When you feel like relieving yourself, you should do so before measuring blood pressure.
• Measure blood pressure where the room tem­perature is about 20˚C. Do NOT measure blood pressure when it is too cold (below 10˚C) or too hot (above 40˚C) in the room.
• Do NOT measure blood pressure immediately after drinking coffee or tea or smoking.
• Measure blood pressure with a relaxed and quiet posture. Keep the center of the cuff at the level of your heart, and do NOT move your arm or talk during measurement.
• Do NOT keep on measuring so many times, as your arm will have built up congestion of blood, and you will not get a valid reading.
PRECAUTION FOR USE AND MAINTENANCE
Precautions for use
• If you suffer from heart disease, high blood pressure or other circulatory disease, please consult your doctor first.
• If you feel abnormal pressure of the cuff dur­ing use or any other irregularity, reduce the pressure by immediately switching off the
- Eng 3 -
power or removing the batteries and consult the sales outlet where purchased.
• If you think the measured value is abnormal or if measuring makes you feel unwell, discon­tinue use and consult your doctor.
• Measurement of blood pressure may not be possible for someone with a weak pulse or ar­rhythmia.
English
Español
Português
Italiano
Deutch
Français
• Congestion, swelling, etc. may occur in some people.
• If blood pressure is measured repeatedly, an accurate result will not be achieved. An inter­val of about 10 minutes should be allowed.
• The memory is erased if the batteries are re­moved for replacement, etc. and a record should be kept of any necessary data.
Precautions for maintenance
• Do NOT store the blood pressure monitor where it will be exposed to direct sunlight, high temperature (over 60˚C), low temperature (be­low –20˚C), high relative humidity (over 95%) or in a dusty place.
• Do NOT expose the blood pressure monitor to under force or vibration, or drop it.
• Remove the battery/batteries when not in use for a long period.
• Do NOT disassemble the apparatus.
• Do NOT bend the cuff or air hose unnecessar­ily.
• NEVER wipe the blood pressure monitor with thinner or benzene, as they may damage it.
• When the monitor is very dirty, wipe it clean with a cloth moistened with Sterilizing alcohol or a neutral detergent, and then wipe it with a dry cloth. Do NOT use thinner or benzene.
Nature and frequency of maintenance:
This products is designed for use over an ex­tended period of time; however, it is generally recommended that it be inspected every two years to ensure proper function and performance.
Protect the nature environment:
Please help protect natural environment by re­specting national and/or local recycling regula­tions when disposing of the batteries and the products at the end of their useful lives.
- Eng 4 -
IDENTIFICATION OF PARTS
Diastolic blood pressure/ Pulse display section
Battry cover
Systolic blood pressure display section
English
Español
Português
Italiano
Wrist cuff
- Eng 5 -
M
Power/Start switch
Memory recall switch
Deutch
Français
BATTERY REPLACEMENT
1. To use this unit, you must install batteries,
and also If battery mark “ on the display, you must change two pieces of batteries.
2. Open battery cover as illustrated.
Replace the new two pieces of batteries, matching the (+) and (–) polarities on each battery with the polarity marks on the case.
3. “LR03” batteries or equivalent is suitable for
this blood pressure meter.
” will display
MEASUREMENT PROCEDURES
1. Attaching of wrist cuff
The blood pressure is measured at the wrist. Therefore, rolling up the sleeve is no longer necessary. The pressure cuff has integrated into the wristlet. Wind the wristlet around your left wrist. The wrist should be free. The display is at the in­ner of the wrist.
• Pull the transparent ribbon to remove the bat­teries.
- Eng 6 -
• Apply the wrist cuff to the wrist and make sure it is not too loose or too tight. If the wrist cuff is applied inappropriately, it may display an error or abnormal values. Pull the wrist tight and close the “Burr closure”. Wrist circumference: 13.5-19.5 cm.
Measurement Procedures for People With a Weak Pulse
• Apply the middle part of the wrist cuff to the artery in the wrist to measure blood pressure.
2. To start the Measurement
English
Español
Português
Italiano
Deutch
CAUTION
Do not grasp the unit too tightly. Keep your left wrist relaxed during measure­ment period. Do not apply physical pressure against unit with wrist before or during measurement. All measurements must be performed while you are seated and with your left hand on a table held a level with your heart. Keep your body still and relaxed during measurement.
Press the “Power/Start” switch.
- Eng 7 -
Français
The heart symbol flashes, and the buzzer sounds for 1 second. Once the measurement prepara­tions are completed, the buzzer sounds three more times. If batteries become weak, “ ” mark is dis­played and measurement is discontinued.
Pressurization and measuring start.
When a pulse is detected, the pressure value moves to the lower side of the display. At this time the mark “Q” flashes and buzzer beeps.
Once the blood-pressure measurement has sta­bilized, pressurization is discontinued, the air in the cuff is automatically let out, the buzzer sounds for about 2 seconds, and the high and low blood pressure are respectively displayed one above the other.
Unless an error is generated, the measurement results are automatically stored in memory. Up to 7 sets of results can be stored in memory.
- Eng 8 -
When there are already 7 sets of results in memory, the oldest one is automatically erased and overwritten with the newest.
3. Turn Power off
English
Español
Português
(2 second) (1 second) Blood pressure values and pulse rate display al-
ternatively on the display. Display of the mea­surement result will continue until power is turned off.
Press the “POWER/START” switch to turn off.
CAUTION
To discontinue a measurement for any reason, press the “POWER/START” switch. This causes the “wrist cuff” to deflate rapidly.
4. Automatic power-off function
If the unit is left on after measurement an au­tomatic power-off function turns the power off after approximately 3 minutes. To continue measurement press the “POWER/START” switch turning the unit on.
- Eng 9 -
Italiano
Deutch
Français
5. Memory recall
M
• You can recall stored data by pressing the “Memory recall” switch, except when per­forming a measurement.
• Up to 7 sets of measurement results can be stored in memory, and memory cell No. 1 is always used to store the newest set of re­sults.
• When pressing the “Memory recall” switch, the memory cell number is displayed, then the stored measurement results (high/low blood pressure) are displayed.
• If the “Memory recall” switch is pressed fur­ther, the old date are indicated in the order of the time series.
- Eng 10 -
6. Memory clear function
English
Español
M
While the memory datum to be cleared are in­dicated and when the “Memory recall” switch is continued to push for 3 seconds, buzzer beeps and the memory datum are cleared.
Português
Italiano
Deutch
Français
- Eng 11 -
DESCRIPTION OF DISPLAY MARKS
DISPLAY MARK CONDITION / CAUSE CORRECTIVE ACTION
The cuff was inflated to more than 280 mmHg.
Exhaust the air with in the cuff.
Pressurization is not possible Cuff winding has not been performed correctly.
The pulse could not be measured ac­curately.
The arm moved during measurement.
Device has a trouble.
Appears when the pulse could not be measured.
Appears when the batteries become weak.
Device has a trouble.
- Eng 12 -
After winding the cuff over again, re­peat measurement.
After again winding the cuff, conduct the measurement without moving.
Repeat the measurement without mov­ing the arm.
Ask purchased shop.
Repeat the measurement without mov­ing the arm.
Replace the batteries.
Ask purchased shop.
CITIZEN is a registered trademark of Citizen Watch Co., Japan.
Consumer Electronics Division
CBM Bldg. 5F, 5-68-10, Nakano, Nakano-ku, Tokyo 164-0001, Japan Phone: (03)5345-7430 Fax: (03)5345-7431 E-mail: info-con@jcbm.co.jp
Loading...