Carnes VWBK-06 Installation Manual

CARNES COMPANY, 448 S.Main St., P.O.Box 930040, Verona, WI. 53593-0040 Phone:608/845-6411 Fax: 608/845-6470 carnes@carnes.com http://www.carnes.com
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
CENTRIFUGAL SPUN ALUMINUM WALL FANS
MODEL VW — BELT and DIRECT DRIVE
CAUTION! DO NOT INSTALL, USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAD BEEN
READ AND UNDERSTOOD. READ AND SAVE
THESE SHEETS FOR FUTURE USE.
RECEIVING, HANDLING AND STORAGE
1. Handle the fan with care. Avoid severe jarring or dropping of the unit.
2. Carefully inspect the unit for damage upon delivery. If the unit has been damaged in transit it is the responsibility
of the recipient to make all claims against the carrier.
3. Provide adequate, protected storage prior to installation.

INSTALLATION

1. Upon unpacking, inspect the unit for any damage that may have occurred in transit. Check also for loose or
missing parts.
2.
CAUTION!
This fan contains rotating parts and requires electrical service. Appropriate safety precautions should
be taken during installation, operation and maintenance.
3.
WARNING!
Do not install or operate this fan in an environment or atmosphere where combustible or flammable materials, gasses or fumes are present, unless it has been specifically designed and manufactured for use in that environment. Explosion or Fire could result.
4. This ventilator is designed to be wall mounted. Mount the fan according to the direction label and with the motor cover louvers on the downside.
5. This ventilator requires minimum of four (4) mounting fasteners of the appropriate size and type in order to be securely fastened to the mounting frame. Be sure to use an approved sealant between the fan and mounting frame to prevent leaking.
6. A damper, if used, should be securely mounted in a manner which allows free and unobstructed operation. Fan wiring should not interfere with damper blades.
7.
CAUTION!
All electrical work must be done in accordance with local and/or national electrical code as applicable.
If you are unfamiliar with methods of installing electrical wiring, secure the services of a qualified electrician.
8. WARNING! This product must be grounded.
9.
DANGER!
Make sure power is turned off and locked in OFF position at the service entrance before installing,
wiring or servicing fan.
10.
CAUTION!
Before wiring the motor, check the supply voltage against the motor nameplate voltage. High or low
voltage can damage the motor and void the warranty.
12. Power should be routed through the conduit openings provided.
12. Access to the motor compartment is possible by either removing the motor cover or motor tube/motor cover
assembly.
13.
WARNING!
Be sure to keep all wiring clear of rotating or moving parts.
14.
WARNING!
Before starting the fan, turn the wheel to assure it rotates freely. If needed, adjust the wheel/shaft
bearing/motor position as required to achieve necessary clearances.
15.
CAUTION!
On belt drive units assure belts are tensioned and aligned properly. (See Maintenance section).
16.
WARNING!
Check all set screws and keys, tighten as necessary prior to fan start up. DO NOT over torque.
17. Remount motor cover/tube, do not over torque fasteners (30 in. - lb. maximum).
FORM 1407, Page 1
OPERATION
1.
CAUTION!
Check that the fan inlet/ductwork/exhaust openings are clean and free of obstructions. Poor inlet con-
ditions will result in seriously reduced fan performance.
2.
WARNING!
This fan contains rotating parts. Appropriate safety precautions should be taken during operation.
3. Operate under power and check for correct wheel rotation direction (clockwise when looking at top of the wheel).
4.
CAUTION!
Incorrect rotation can damage the fan motor and seriously impede fan operation.

MAINTENANCE

1.
DANGER!
Before performing and maintenance on the fan, be sure power is turned off and locked in the OFF
position at the service entrance before servicing the fan.
2. Ventilators should be carefully checked at least once a year. For critical or rugged applications, a routine check every two or three months is suggested.
3. All motors supplied with CARNES ventilators carry a one year warranty from date of shipment. For repairs within the warranty period, the motor must be taken to the motor manufacturer’s authorized service dealer. Contact your CARNES representative for additional warranty details.
4. Access to the motor compartment is possible by removing the motor cover or motor cover/motor tube assembly.
5. A periodic motor check should consist of spinning the motor shaft with the power off to be sure the motor turns
freely and the bearings run smoothly. The belt on belt driven units should be removed from the motor sheave.
6. CAUTION! When removing or installing a belt, do not force the belt over the sheave. Loosen the motor mount so that the belt can be easily slipped over the sheave.
7. The belt on belt driven units should be removed and carefully checked for radial cracks, ply separation or irregular wear. A small irregularity in the contact surface of the belt will result in noisy operation. If any of these defects are apparent, the belt should be replaced. Check the sheave also for chipping, dents or rough surfaces which could damage the belt.
8.
CAUTION!
The correct belt tension is important. Too tight a belt will result in excess bearing pressure on the motor bearings and shaft pillow blocks, and may also overload the motor. Too loose a belt will result in slippage which will quickly “burn” out belts. A belt should feel “live” when thumped, approximately 1/4” belt deflection when subjected to finger pressure (3 to 5 lbs.) at midpoint between sheaves.
9.
CAUTION!
The belt alignment should also be checked to be sure the belt is running perpendicular to the rotating shafts. Motor and drive shafts must be parallel. Improper alignment will result in excessive belt wear.
10.
CAUTION!
Check sheave set screws to ensure tightness. Proper keys must be in keyways.
11.
CAUTION!
Do not readjust variable pitch sheave without checking motor amps. Do not readjust variable pitch sheaves above the maximum catalog RPM for unit and motor. If fixed sheaves are replaced, use only sheaves of identical size and type.
12.
CAUTION!
If adjustment of two groove variable pitch sheaves is required, each sheave must be opened or closed the same number of turns. Improper adjustment can cause excessive belt wear and premature failure.
2