Carnes VCDD210I Installation Manual

IN-LINE CABINET VENTILATORS
READ AND SAVE THESE INSTRUCTIONS
MODELS • VCDD210I • VCDD330I
®
Page 1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN­JURY TO PERSONS, OBSERVE THE FOLLOWING:
1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3.Installation work and electrical wiring must be done by a quali­fied person(s) in accordance with all applicable codes and stan­dards, including fire-rated construction codes and standards.
4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Con­ditioning Engineers (ASHRAE), and the local code authorities.
5.When cutting or drilling into wall or ceiling, do not damage elec­trical wiring and other hidden utilities.
6.Ducted fans must always be vented to the outdoors.
7. This unit must be grounded.
CAUTION
1.For general ventilating use only. Do not use to exhaust hazard­ous or explosive materials and vapors.
2.To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
3.Please read specification label on product for further informa­tion and requirements.
!
PLAN INSTALLATION
MOUNTING
3/8” MIN.
THREADED ROD
(By Others)
ACCESS
PANEL
DUCT
FLANGES
Factory shipped ready to be installed as a ceiling
MOUNTING
3/8” MIN.
THREADED ROD
(By Others)
INTAKE
DUCT
FLANGES
(Right-angle Discharge)
MOUNTING CHANNELS
GRILLE KIT
INTAKE
ventilator with right-angle discharge.
(In-line Configuration)
ADJUSTABLE
BRACKET
INTAKE
ACCESS
PANEL
EXHAUST
CEILING
EXHAUST
Converted for in-line applications.
MODELS • VCDD210I • VCDD330I
®
PLAN INSTALLATION (cont.) MOUNTING OPTIONS
CONVERTING FROM RIGHT-ANGLE T O IN-LINE
ACCESS
PANEL
EXHAUST
DUCT FLANGE
EXHAUST
DUCT FLANGE
INTAKE DUCT
FLANGES
Remove and reverse duct flanges and access panel
positions on housing.
For correct intake and exhaust duct size, see Table 1.
DIM. VCDD210I VCDD330I
C 12-5/8” 12-5/8” D 39-5/8” 47-3/8”
THREADED RODS
Page 2
3/8” MIN.
(By Others)
TABLE 1
MODEL INTAKE DUCT SIZE EXHAUST DUCT SIZE
VCDD210I 12-3/8” x 35-3/4” 7-3/4” x 33-3/4” VCDD330I 14-1/2” x 43-1/2” 9-3/4” x 41-3/8”
MOUNTING OPTIONS
Provide solid support to minimize sound leves. There are two basic mounting methods for these units.
3/8” MIN. THREADED RODS
(By Others)
DIM. VCDD210I VCDD330I
A 7-3/4” 10-1/4” B 33-3/4” 41-3/4”
Mounting with threaded r od through adjustable
mounting brackets located at top of housing.
Mounting brackets can be bolted to housing ends in a variety of configurations. Use screws and nuts provided in parts bag.
Typical mounting with threaded r od through
mounting channels on top of housing.
Mounting with threaded r ods through adjustable
mounting brackets located at bottom of housing.
If installing unit as a ceiling ventilator, make sure that either duct flanges or housing will be flush with finished ceiling. Duct flanges may be removed and discarded if the y interfere with a ceiling instal­lation.