Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
12-Volt Inflator
Description
The RP3200 12-volt infl ator is intended for emergency roadside tire infl ation and to infl ate bicycle tires, soccer balls, and other sports equipment. The infl ator includes an auto-shut-off gauge that shuts the unit off at the desired pressure, and a light.
Unpacking
After unpacking the unit, inspect carefully for any damage that may have occurred during transit.
Safety Guidelines
This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.
Danger indicates
an imminently hazardous situation which, if not avoided, WILL result in death or serious injury.
Warning indicates
a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.
Caution indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury.
Notice indicates
important information, that if not followed, may cause damage to equipment.
NOTE: Information that requires special attention.
Automatic
shut-off gauge
Light
Figure 1
Important Safety Instructions
ANY MISUSE OF UNIT COULD CAUSE PROPERTY OR EQUIPMENT DAMAGE AND/OR PERSONAL INJURY.
This manual contains safety, operational and maintenance information. Contact your Campbell Hausfeld representative if you have any questions.
CALIFORNIA PROPOSITION 65
This product or
contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.
GENERAL
a. To reduce the risks of
electric shock, fire, and injury to persons, read all the instructions before using the unit.
its power cord may
MANUAL
Hose, Cord, Accessory Storage
Specifications
Maximum Pressure . . . . . . . . . . 140 psi
Continuous . . . . . . 0.66 SCFM @ 0 psi
Volume . . . . . . . . . 0.54 SCFM @ 30 psi
Weight . . . . . . . . . . . . . . . . . . . 3.0 lbs.
Voltage . . . . . . . . . . . . . . . . 12-Volt DC
Cord length . . . . . . . . . . . . . . . 11 feet
Air Outlet . . . . . . . . Universal Adapter
Fuse . . . . . . . . . . . . . . . . . . . . . .10 Amp
b. Be thoroughly familiar with the
controls and the proper use of the equipment. Follow all instructions. Contact your Campbell Hausfeld representative if you have any questions.
c. Only persons well acquainted with
these rules of safe operation should be allowed to use the unit.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.chpower.com
IN299501AV 8/09
Operating Instructions RP3200
Important Safety Instructions (Continued)
Do not leave the
infl ator unattended
while the unit is running. Never
exceed the recommended pressure for any infl atable object. Do not over infl ate objects. Over infl ation could cause property damage and/or personal injury.
Always put the car
in park; set the emergency brake; and chock the wheels before using the infl ator or property damage and/or personal injury could occur.
The universal
adapter must be locked to secure the infl ation accessories. Use extreme caution when using infl ation accessories.
Avoid long extended
Always use a separate pressure gauge to check the actual pressure in tires and in low pressure infl atable objects.
Avoid long extended
Infl ator must cool for 20 minutes after 20 minutes of continuous oper-ation. The Infl ator is not designed to operate continuously for more than 20 minutes.
The work surface
Do not use infl ator on high pressure tires used on large trucks, trailers or tractors. The infl ator is not designed to operate for the length of time necessary to infl ate these tires.
Make sure the
universal adapter touches the core or tire valve stem.
Operation
For use with 12-volt
rated 10 amps or higher. Do not use with older 8 amp cigarette lighter receptacles.
Overinfl ation can be dangerous.
Pay attention while infl ating
low pressure items to prevent
TIRES
1. Remove valve stem cap.
2. Attach the universal adapter (see Figure 2) from the inflator to the valve stem with the lever in the up position. Be sure to press universal adapter down over valve stem threads completely. When universal adapter is firmly in place, press locking lever down to lock onto valve stem.
3. Plug power cord into cigarette lighter receptacle.
4. Set automatic shut-off gauge by turning ring on gauge until bottom edge of pointer is just above the desired pressure (see Figure 3).
It may be necessary
higher than desired pressure to prevent unit from turning off prematurely.
5. Turn on inflator and wait until inflator shuts off.
6. Check that the tire pressure is correct.
DC power outlets
overinfl ation.
to set pointer 2-3 psi
7. To add additional air pressure, set shut-off at higher pressure and turn power switch off and then back on to restart inflator.
User - Maintenance Instructions
FUSE REPLACEMENT
NEVER replace a blown fuse with a fuse having a higher rating.
1. Unscrew end of plug counter­clockwise to remove fuse.
2. If fuse is blown, replace with a new 10-amp fuse. Always replace a blown fuse with the same size fuse.
3. Reassemble plug. Do not overtighten.
TECHNICAL SERVICE
Please call our Tool Hotline at 1-800­543-6400 with any questions regarding the operation or repair of this unit or for additional copies of this manual.
UNIT REPAIR
Only qualified personnel should repair the unit and they should use genuine Campbell Hausfeld replacement parts and accessories, or parts and accessories which perform equivalently.
STORAGE
The unit should be stored in a cool dry place.
Open
www.chpower.com
Lock
Universal Adapter
Valve Stem
Figure 3 - Shut-off set for 30 psi.Figure 2
2
Operating Instructions RP3200
Notes
3
www.chpower.com
Operating Instructions RP3200
Limited Warranty
1. DURATION: From the date of purchase by the original purchaser as follows: One (1) Year.
2. WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400
3. WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld product.
4. WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: Any Campbell Hausfeld nailer, stapler, air tool, spray gun, inflator or air accessory supplied or manufactured by Warrantor.
5. WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects in material and workmanship which occur within the duration of the warranty period.
6. WHAT IS NOT COVERED UNDER THIS WARRANTY:
A. Implied warranties, including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED
FROM THE DATE OF ORIGINAL PURCHASE AS STATED IN THE DURATION. If this product is used for commercial, industrial or rental purposes, the warranty will apply for ninety (90) days from the date of purchase. Some States do not allow limitation on how long an implied warranty lasts, so the above limitations may not apply to you.
B. ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY
DEFECT, FAILURE, OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
C. Any failure that results from an accident, purchaser’s abuse, neglect or failure to operate products in accordance
with instructions provided in the owner’s manual(s) supplied with product. Accident, purchaser's abuse, neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any
safety devices. If such safety devices are removed or altered, this warranty is void. D. Normal adjustments which are explained in the owner’s manual(s) provided with the product. E. Items or service that are normally required to maintain the product, i.e. o-rings, springs, bumpers, debris shields,
driver blades, fuses, batteries, gaskets, packings or seals, fluid nozzles, needles, sandblast nozzles, lubricants,
material hoses, filter elements, motor vanes, abrasives, blades, cut-off wheels, chisels, chisel retainers, cutters,
collets, chucks, rivet jaws, screw driver bits, sanding pads, back-up pads, impact mechanism, or any other
expendable part not specifically listed. These items will only be covered for ninety (90) days from date of
original purchase. Underlined items are warranted for defects in material and workmanship only.
7. RESPONSIBILITIES OF WARRANTOR UNDER THIS WARRANTY: Repair or replace, at Warrantor’s option, products or components which are defective, have malfunctioned and/or failed to conform within duration of the warranty period.
8. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY:
A. Provide dated proof of purchase and maintenance records. B. Call Campbell Hausfeld (800) 543-6400 to obtain your warranty service options. Freight costs must be borne by
the purchaser.
C. Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s).
9. WHEN WARRANTOR WILL PERFORM REPAIR OR REPLACEMENT UNDER THIS WARRANTY: Repair or replacement will be scheduled and serviced according to the normal work flow at the servicing location, and depending on the availability of replacement parts.
This Limited Warranty applies in the United States, Canada and Mexico only and gives you specific legal rights. You may also have other rights which vary from state to state or country to country.
www.chpower.com