CARA TTERISTICHE GENERALI
Descrizione quadro
Il quadro elettrico ZL16 è adatto al comando di una automazione per cancelli a battente della serie WINNY a 24V. Alimentato a 230V con potenza max. fino a 100W, frequenza 50÷60Hz. Progettato e costruito interamente dalla CAME S.p.A., risponde alle vigenti norme UNI 8612. Contenitore in ABS con grado di protezione IP54, dotato di presa per il riciclo d’aria e completo di trasformatore. Il circuito va alimentato sui morsetti L1­L2 e protetto in ingresso con fusibile da 1A, mentre i dispositivi di comando a bassa tensione sono protetti con fusibile da 3.15A. La potenza complessiva degli accessori (24V) non deve superare i 40W. Include un dispositivo amperometrico, che garantisce l’arresto immediato del movimento in caso di ostacolo.
Sicurezza
Le fotocellule possono essere collegate e predisposte per:
Riapertura
-
in fase di chiusura (2-C1), le fotocellule rilevando un ostacolo durante la fase di chiusura della porta, provoca­no l'inversione di marcia fino alla com­pleta apertura;
Stop totale
-
(1-2), arresto del cancello con l’esclusione del ciclo di chiusura automatica; per riprendere il movimento bisogna agire sulla pulsantiera o sul radiocomando;
290
197
110
Altre funzioni
-
Chiusura automatica
.
Il temporizzatore di chiusura
S2)
(vedi ponticello
automatica si autoalimenta a finecorsa apre. Il tempo prefissato regolabile, è in ogni modo subordinato all'intervento di eventuali accessori di sicurezza e si esclude dopo un intervento di "stop" o in mancanza d'energia elettrica.
"Uomo presente"
-
(vedi ponticello S1). Funzionamento del portone mantenendo premuto il pulsante (esclude la funzione del radiocomando);
Regolazioni
- Tempo lavoro;
- Tempo chiusura automatica;
- Sensibilità amperometrica.
Attenzione! Prima di intervenire al-
l’interno dell’apparecchiatura, togliere la tensione di linea.
Accessori collegabili
Elettroserratura 12V-
-
15W
, (1-ES)
ENGLISH
GENERAL CHARACTERISTICS
Description of control panel
The ZL16 electric panel is suitable for controlling one automation of WINNY 24V series swing gates. 230V power supply with up to 100W power and 50-60 Hz frequency. Wholly designed and built by CAME S.p.A., it meets UNI 8612 regulations in force. ABS Case with an IP54 protective level, with air recycling inlet and trans­former. The circuit requires 230V (a.c.) at termi­nal blocks L1- L2 and the inlet is pro­tected with one 1A fuse, whilst the low voltage command devices are protected by a 3.15A fuse. The accessories’ total wattage (24V) must not exceed 40W. The panel includes a amperometric safety device for motor, that immediately stops movement if gate hits an obstacle.
Other functions
-
Automatic closing
(see bridge connection S2). The automatic closing timer is automatically activated at the end of the opening cycle. The preset, adjustable automatic closing time is automatically interrupted by the activation of any safety system, and is deactivated after a STOP command or in case of power failure;
"Operator present"
-
(see bridge connection S1). Gate operates only when the pushbutton is held down (the radio remote control system is deactivated);
Adjiustments
- Operating time;
- Automatic closure time;
- Amperometric sensitivity
Safety
Photocells can be connected to obtain:
Re-opening
-
during closure (2-C1), if the photocells identify an obstacle while the gate is closing, they will reverse the direction of movement until the gate is completely open;
Total stop
-
(1-2), shutdown of gate movement without automatic closing; a pushbutton or radio remote control must be actuated to resume movement).
Accessories which can be connected
- 12V-15W electric lock
, connect it to ter-
minal blocks 1-ES.
Caution! Disconnect the unit from
the main power lines before carrying out any operation inside the unit.
-2-
FRANÇAIS
CARACTÉRISTIQUES GÉNÉRALES
Description armoire de commande
L’armoire électrique ZL16 sert à commander une automation des portails à battant de la série WINNY à 24V. Alimentée à 230V avec une puissance jusqu’à 100W, fréquence 50÷60Hz. Conçu et construit entièrement par CAME S.p.A., il est conforme aux normes NFP 25-362 en vigueur. Boîtier en ABS avec degré de protection IP54, équipé d’une prise pour le recyclage de l’air et d’un transformateur. Le circuit doit être alimenté avec une tension de 230V (c.a.) aux bornes L1­L2 et doit être protégé à l’entrée par une fusible de 1A, tandis que les dispositifs de commande à basse tension sont protégés par un fusible de 3.15A. La puissance totale des accessoires (24V) ne doit pas dépasser 40W. L’armoire est prévu avec la fonction de dispositif ampèremétrique des moteur. Il assure l’arrêt instantané du mouvement en cas d’ostacle.
Sécurité
Accessoires pouvant être branchés
Serrure électrique 12V-15W
, la brancher
aux bornes 1-ES.
Autres functions
Fermeture automatique
-
.
Le temporisateur de fermeture
S2)
(voir pontet
automatique est autoalimenté à la fin du temps de la course en ouverture. Le temps réglable est programmé, cependant, il est subordonné à l’intervention d’éventuels accessoires de sécurité et il est exclu après une inter­vention de “stop” ou en cas de coupure de courant;
“Homme mort”
-
(voir pontet S1). Fonctionnement du portail en maintenant appuyé le bouton-poussoir (exclut la fonction de la radiocommande);
Réglages
- Temps de fonctionnement;
- Temps de fermeture automatique;
- Sensibilité ampèrométrique.
Il est possible de brancher des photocellules et de les programmer pour:
Réouverture
-
en phase de fermeture (2­C1), les cellules photoélectriques provoquent l'inversion de marche jusqu'à l'ouverture complète si elles relèvent un obstacle durant la phase de fermeture du portail;
Stop total
-
(1-2), arrêt du portail et désactivation d’un éventuel cycle de fermeture automatique; pour activer de nouveau le mouvement, il faut agir sur les boutons-poussoirs ou sur la radiocommande).
Attention! Avant d’intervenir à l’intérieur de l’appareillage, couper la tension de ligne.