BUCHI M-560 User Manual

0 (0)

Operation Manual

Melting Point

M 560

093251 en

Table of contents

Table of contents

1

About this manual

 

 

 

5

 

1.1

Reference documents

 

 

 

5

 

1.2

Abbreviations . . . . . . . . . . . . . .

. . . . . . . . . .

.

 

5

2

Safety

 

 

 

 

6

 

2.1

User qualification . . . . . . . . . . . .

. . . . . . . . . .

.

.

6

 

2.2

Proper use . . . . . . . . . . . . . .

. . . . . . . . . .

.

.

6

 

2.3

Improper use . . . . . . . . . . . . . .

. . . . . . . . . .

.

 

6

 

2.4

Warning notices used in this manual . . . . . .

. . . . . . . . . .

.

 

7

 

2.5

Product safety

 

 

 

7

 

2.5.1

Instrument-related hazards . . . . . . . . .

. . . . . . . . . .

.

 

. 7

 

2.5.2

Other hazards

 

 

 

7

 

2.5.3

Safety measures . . . . . . . . . . . .

. . . . . . . . . .

.

.

8

 

2.5.4

Safety elements

 

 

 

8

 

2.6

General safety rules . . . . . . . . . . . .

. . . . . . . . . .

.

 

8

3

Technical data . . . . . . . . . . . . . . . .

. . . . . . . . . .

.

 

9

 

3.1

Scope of delivery . . . . . . . . . . . .

. . . . . . . . . .

.

.

9

 

3.1.1

Standard accessories . . . . . . . . . . .

. . . . . . . . . .

.

 

. 9

 

3.1.2

Optional accessories . . . . . . . . . . .

. . . . . . . . . .

.

 

11

 

3.2

Technical data overview

 

 

 

12

 

3.3

Materials used

 

 

 

13

4

Description of function . . . . . . . . . . . .

. . . . . . . . . .

.

. 14

 

4.1

Melting Point . . . . . . . . . . . . . .

. . . . . . . . . .

.

 

14

 

4.2

Boiling Point

 

 

 

14

 

4.3

Controls and connections

 

 

 

15

5

Putting into operation

 

 

 

16

 

5.1

Installation site

 

 

 

16

 

5.2

Commissioning . . . . . . . . . . . . .

. . . . . . . . . .

.

 

16

 

5.2.1

Unpacking and installation

 

 

 

16

 

5.2.2

Power connection

 

 

 

18

 

5.2.3

Calibration

 

 

 

18

Read this manual carefully before installing and running your system; take particular note of the safety precautions in section 2. Keep the manual in the immediate vicinity of the instrument, so that it can be consulted at any time.

No technical modifications may be made to the instrument without the prior written agreement of BUCHI. Unauthorized modifications may affect system safety or result in accidents. This manual is copyrighted. Information from it may not be reproduced, distributed, or used for competitive purposes, nor made available to third parties. The manufacture of any component with the aid of this manual without prior written agreement is also prohibited.

The English manual is the original language version and serves as basis for all translations into other languages. Other language versions can be downloaded at www.buchi.com.

3

Melting Point M-560 Operation Manual, Version D

Table of contents

6

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 

19

 

6.1

Basic operating principles

 

19

 

6.1.1

Display during idle

 

19

 

6.1.2

Display during a process or in menus . . . . . . . . . . . . . . . .

.

20

 

6.1.3

Entering text

 

21

 

6.1.4

Using the external keyboard

 

21

 

6.2

Melting point determination . . . . . . . . . . . . . . . . . . . .

 

22

 

6.2.1

Sample preparation . . . . . . . . . . . . . . . . . . . . . .

.

22

6.2.2Determination without pre-registered melting point method . . . . . . . . . . 23

6.2.3

Creating a method . . . . . . . . . . . . . . . . . . . . . .

.

26

6.2.4

Using and handling methods . . . . . . . . . . . . . . . . . . .

 

. 26

6.2.5

Adjusting parameters during a determination . . . . . . . . . . . . . .

 

27

6.2.6

Printout . . . . . . . . . . . . . . . . . . . . . . . . . .

.

27

6.3

Boiling point

 

28

6.3.1

Sample preparation . . . . . . . . . . . . . . . . . . . . . .

.

28

6.3.2Determination without pre-registered boiling point method . . . . . . . . . . 28

 

6.3.3

Creating a method . . . . . . . . . . . . . . . . . . . . . .

.

30

 

6.3.4

Adjusting parameters during a determination . . . . . . . . . . . . . .

 

30

 

6.3.5

Printout . . . . . . . . . . . . . . . . . . . . . . . . . .

.

31

 

6.4

Calibration

 

32

 

6.4.1

Calibration principle . . . . . . . . . . . . . . . . . . . . . .

.

32

 

6.4.2

Calibration procedure . . . . . . . . . . . . . . . . . . . . . .

 

32

 

6.4.3

Printout . . . . . . . . . . . . . . . . . . . . . . . . . .

.

34

 

6.4.4

Verification

 

35

 

6.5

Settings, SysInfo, Test

 

35

 

6.5.1

Test protocol . . . . . . . . . . . . . . . . . . . . . . . .

.

37

 

6.5.2

SysInfo protocol

 

38

7

Maintenance

 

39

 

7.1

Housing

 

39

 

7.2

Glass window

 

39

 

7.3

Upkeep . . . . . . . . . . . . . . . . . . . . . . . . . .

.

39

 

7.4

Cleaning the heating block . . . . . . . . . . . . . . . . . . . .

 

39

8

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . .

 

41

 

8.1

Malfunctions and their remedy

 

41

 

8.1.1

Setting the printer baud rate

 

43

 

8.2

Customer service . . . . . . . . . . . . . . . . . . . . . . .

 

. 43

9

Shutdown, storage, transport, and disposal . . . . . . . . . . . . . . .

 

. 44

 

9.1

Storage and transport

 

44

 

9.2

Disposal

 

44

10

Spare parts

 

45

11

Declarations and requirements

 

46

 

11.1

FCC requirements (for USA and Canada) . . . . . . . . . . . . . . .

 

. 46

 

11.2

Declaration of conformity . . . . . . . . . . . . . . . . . . . .

.

47

4

Melting Point M-560 Operation Manual, Version D

1  About this manual

1 About this manual

This manual describes the Melting Point M-560 and provides all the information required for its safe operation and to maintain it in good working order.

It is addressed in particular to laboratory personnel and operators.

NOTE

The symbols pertaining to safety (WARNINGS and ATTENTIONS) are explained in section 2.

1.1Reference documents

For more information regarding melting point, refer to the corresponding literature:

The Laboratory Assistant 94187

Melting Point M-560, Operating Manual numbers 93251–93255

Melting Point M-565, Operating Manual numbers 93256–93260

1.2Abbreviations

Chemicals:

PTFE

Polytetrafluoroethylene

PP

Polypropylene

PE

Polyethylene

EPDM

Ethylene-propylene-diene rubber

POM

Polyoxymethylene

PUR

Polyurethane

Miscellaneous:

mp

Melting point

bp

Boiling point

pharm.

Pharmacopoeia

therm.

Thermodynamic

L

Sample left

C

Sample center

R

Sample right

5

Melting Point M-560 Operation Manual, Version D

2  Safety

2 Safety

This section highlights the safety concept of the Melting Point M-560 and contains general rules of behavior and warnings about hazards concerning the use of the product.

The safety of users and personnel can only be ensured if these safety instructions and the safety-​ related warnings in the individual sections are strictly observed and followed. Therefore the manual must always be available to all persons performing the tasks described herein.

2.1User qualification

The instrument may be used only by laboratory personnel or other persons whose training or professional experience give them an overview of the dangers which can develop when operating the instrument.

Personnel without this training or persons who are currently being trained require careful supervision. This Operation Manual serves as a basis for training.

2.2Proper use

The instrument has been designed and built for laboratory use only. It is intended to be used to determine melting and boiling points and melting ranges at ambient temperatures up to 400 °C.

2.3Improper use

Applications beyond those described above are improper. Furthermore, applications which do not comply with the technical data are also considered improper. The operator bears the sole risk for any damages caused by such improper use.

The following applications in particular are expressly forbidden:

Use in rooms requiring explosion-proof equipment.

Extraction of samples which may explode or ignite as the result of a blow, friction, heat, or spark (e.g. explosives).

6

Melting Point M-560 Operation Manual, Version D

2  Safety

2.4Warning notices used in this manual

WARNING

Generally, the triangular warning symbol indicates the possibility of personal injury or even loss of life if the instructions are not followed.

WARNING

Hot surface.

WARNING

Electrical hazard.

WARNING

Biohazard.

ATTENTION

The “read this” symbol for ATTENTION indicates that equipment damage, malfunctions, or incorrect processes may result if the instructions are not followed.

NOTE

Useful tips to facilitate operation of the instrument.

2.5Product safety

The Melting Point M-560 is designed and built in accordance with current state-of-the-art technology. However, risks to users, property, and the environment can arise when the instrument is used carelessly or improperly.

The manufacturer has determined residual dangers emanating from the instrument

if the instrument is operated by insufficiently trained personnel.

if the instrument is not operated properly.

Appropriate warnings in this manual serve to alert the user to these residual dangers.

2.5.1Instrument-related hazards

Pay attention to the following safety notices:

WARNING

Potentially hot surfaces during operation, especially the heating oven (up to 400 °C).

Always be aware of the danger of being burned.

2.5.2Other hazards

WARNING

Certain solvents within or in the vicinity of the Melting Point M-560 can form peroxides and/or are highly inflammable.

Always be aware of the explosion risk when working with hazardous substances or with substances of unknown composition.

Always use the instrument in an adequately ventilated work area.

7

Melting Point M-560 Operation Manual, Version D

2  Safety

2.5.3Safety measures

Always wear personal protective equipment such as protective goggles and protective clothing, when working with the instrument.

2.5.4Safety elements

Anti-seismic tie-down

The instrument is equipped with a fixture to tie it down in areas at risk of an earthquake (see bottom side of the instrument).

2.6General safety rules

Responsibility of the operator

The head of laboratory is responsible for training the lab personnel.

The operator shall inform the manufacturer without delay of any safety-related incidents that occur during the operation of the instrument. Legal regulations, such as local, state, and federal laws applying to the instrument, must be strictly followed.

Duty of maintenance and care

The operator is responsible for ensuring that the instrument is operated only in a proper manner and that maintenance, service, and repairs are performed with care, on schedule, and by authorized personnel only.

Spare parts to be used

Use only recommended consumables and spare parts for maintenance in order to ensure continued optimum system performance and reliability. Modifications to the spare parts used are allowed only with the prior written permission of the manufacturer.

Modifications

Modifications to the instrument are permitted only after prior consultation with and written approval from the manufacturer. Modifications and upgrades should be carried out only by an authorized BUCHI technical engineer. The manufacturer reserves the right to decline any claim resulting from unauthorized modifications.

8

Melting Point M-560 Operation Manual, Version D

3  Technical data

3 Technical data

This section introduces the reader to the Melting Point M-560 and its main components. It contains technical data, requirements and performance data.

3.1Scope of delivery

Check the scope of delivery according to the order number.

NOTE

For detailed information on the listed products, see www.buchi.com or contact your local dealer.

3.1.1Standard accessories

Table 3-1: Standard accessories

Product

Order number

 

 

Melting Point M-560

051999

 

 

Calibration set M-560/M-565

11055018

(4 substances; 4-nitrotoluene, diphenyl acetic acid, caffeine, potassium nitrate)

Melting point capillaries, 100 units

017808

 

 

9

Melting Point M-560 Operation Manual, Version D

3  Technical data

Table 3-1: Standard accessories (cont.)

Product

Order number

 

 

Sample holder

11055014

 

 

 

 

Cleaning tool

051978

 

B

A) Boiling point tubes, 10 units

019697

B

B) Boiling point capillaries, 10 units

051850

 

 

A

A

Compaction wire

036721

 

 

Operation Manual:

 

 

 

English

93251

 

 

German

93252

 

 

French

93253

 

 

Italian

93254

 

 

Spanish

93255

 

 

10

Melting Point M-560 Operation Manual, Version D

BUCHI M-560 User Manual

3  Technical data

3.1.2Optional accessories

Table 3-2: Optional accessories

Product

Order number

 

 

Sample Loader M-569

051997

 

 

Verification set M-560/M-565

11055019

(3 substances; benzil, p-anisic acid, phenolphthalein)

Melting point capillaries, 1000 units

001759

 

 

Mortar and pestle, agate

041867

 

 

Compact keyboard German (CH)

029509

Compact keyboard English (USA)

029508

 

 

Serial dot matrix printer (including ribbon, 11055438 paper roll, and cables)

11

Melting Point M-560 Operation Manual, Version D

3  Technical data

Table 3-2: Optional accessories (cont.)

Product

Order number

 

 

Ribbon for printer

044306

 

 

Paper roll for printer

038684

 

 

A) Boiling point tubes, 100 units

019007

 

 

B) Boiling point capillaries, 100 units

051890

 

 

Protective cover

051935

 

 

3.2

Technical data overview

 

 

 

 

 

 

 

 

Table 3-4: Technical data of the Melting Point M-560

 

 

 

 

 

Melting Point M-560

 

 

 

 

 

 

 

Manual melting point determination

 

 

 

 

 

 

 

Manual boiling point determination

 

 

 

 

 

 

 

Automatic melting point determination

 

 

 

 

 

 

 

Automatic boiling point determination

 

 

 

 

 

 

 

Homogeneous sample loading

 

 

 

 

 

 

 

Positions for melting capillaries

3

 

 

 

 

 

 

 

Positions for boiling capillaries

1

 

 

 

 

 

 

 

Precision magnifying lens

 

 

 

 

 

 

 

Magnification of lens

2.5×

 

 

 

 

 

 

 

Display

Colour, TFT, 320×240, 3.5˝

 

 

 

 

 

 

 

Determination temperature range

Ambient +10 °C to 400 °C

 

 

 

 

 

 

 

Temperature resolution

0.1 °C

 

 

 

 

 

 

 

Accuracy of melting point at 0.5 °C/min

 

 

 

up to 250 °C

±0.3 °C

 

 

 

 

 

12

Melting Point M-560 Operation Manual, Version D

3  Technical data

Table 3-4: Technical data of the Melting Point M-560

 

Melting Point M-560

 

 

250 °C to 400 °C

±0.3 °C to ±0.5 °C

 

 

Repeatability of melting point at 0.5 °C/min

±0.1 °C

 

 

Accuracy of boiling point at 1.0 °C/min up to 400 °C

±0.5 °C

 

 

Repeatability of boiling point at 1.0 °C/min

±0.3 °C

 

 

Temperature gradients, °C/min

0.1, 0.2, 0.5, 1, 2, 3, 5, 10, 20

 

 

Heat-up time (50 °C–350 °C) at 25 °C

~4 min

 

 

Cool-down time (350 °C–50 °C) at 25 °C

~13 min

 

 

Electrical supply

100–240 V (±10 %), 50–60 Hz

 

 

Power consumption

150 W

 

 

Contact termination

L, N, PE

 

 

Approval

CE, CSA, UL

 

 

Dimensions (W×H×D), mm

190×200×370

 

 

Weight, kg

4.5

 

 

Environmental conditions

For indoor use only

 

 

Temperature

5–40 °C

 

 

Altitude

up to 2000 m a.s.l.

 

 

Humidity

Maximum relative humidity 80 % for temperatures up to

 

31 °C, decreasing linearly to 50 % relative humidity at 40 °C

 

 

Overvoltage category

II

 

 

Degree of protection

IP20

 

 

Pollution degree

2

 

 

Storable methods for melting point

50

 

 

Storable methods for boiling point

50

 

 

Compliant with Pharmacopeia methods

PH. EUR. 6.1.2.2.60, USP XXI 741 and JP

 

 

NOTE

Temperature measuring accuracy refers to pharmacopoeia melting point.

3.3

Materials used

 

 

 

 

 

 

 

Table 3-5: Materials used

 

 

 

 

 

 

 

Component

Material designation

 

 

 

 

 

 

Print holder

PA

 

 

 

 

 

 

Heating block

Aluminium

 

 

 

 

 

 

Lenses

Glass

 

 

 

 

 

 

Axial fan

Aluminium

 

 

 

 

 

 

Housing

PU, Stainless Steel, Glass

 

 

 

 

 

 

Cover

POM, Ceramic, Aluminium, Stainless Steel

 

 

 

 

13

Melting Point M-560 Operation Manual, Version D

4  Description of function

4 Description of function

This section explains the basic principle of the Melting Point M-560 and provides a functional description of the assemblies.

4.1Melting Point

The Melting Point M-560 is an instrument for manual (visual) determination of melting point, melting range, and boiling point at ambient temperatures +10 °C up to 400 °C. The melting point of three samples can be determined at the same time. The boiling point can be determined for one sample. Samples have to be observed through the lens.

The melting point capillary sits in a hollow of the metal block, which is heated electrically and controlled by a temperature sensor. The heating block is capable of being maintained accurately at a pre-defined temperature by the heating element, and of being heated at a defined rate.

4.2Boiling Point

The boiling point is determined by the “Siwoloboff” method.

The Melting Point M-560 can be used to determine the boiling point of a small amount of liquid. The heating block has one insert available for boiling point tubes (outside left). The moment of boiling is determined visually.

The process for boiling point determination is analogous to that for determining a melting point:

The start temperature is set 5 to 10 °C lower than the expected boiling point.

The sample is put into the heating block as soon as the start temperature is reached.

A delay time allows the equilibrium between oven temperature and sample temperature. During this delay time some air bubbles escape from the boiling point capillary.

Starting from the start temperature, the sample is heated at a temperature gradient of 1 °C/min.

As the temperature rises, bubbles of gas rise slowly and regularly from the immersed end of the boiling point capillary.

The boiling point of the liquid has been reached when the flow of steam bubbles reaches a frequency of 0.6 Hz [Hertz].

14

Melting Point M-560 Operation Manual, Version D

4  Description of function

4.3Controls and connections

a Power switch; turns the instrument on/off b Start; starts process

c Stop; stops process, starts/stops ventilation, returns to idle screen

d 3 Select and Set buttons

e Rotary knob for navigation through the menu and for select characters

f Display

f

ba

c d e

Fig. 4.1: Front view

 

f

 

d

 

USB

a

b PS/2

e

c

 

RS232

a Mains plug

b PS/2 connection for keyboard

c RS 232 connection for serial printer d USB connection: required for service e Housing cooling fan

f Heating block cooling fan

Fig. 4.2: Rear view

15

Melting Point M-560 Operation Manual, Version D