Brocade 5300 Reference Manual

Page 1
53-1000858-04
®
31 May 2012
Brocade 5300
Hardware Reference Manual
Page 2
© 2012 Brocade Communications Systems, Inc. All Rights Reserved.
Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, MLX, SAN Health, VCS, and VDX are registered trademarks, and AnyIO, Brocade One, CloudPlex, Effortless Networking, ICX, NET Health, OpenScript, and The Effortless Network are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or service names mentioned may be trademarks of their respective owners.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may require an export license from the United States government.
The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer programs that accompany it.
The product described by this document may contain “open source” software covered by the GNU General Public License or other open source license agreements. To find out which open source software is included in Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd.
Brocade Communications Systems, Incorporated
Corporate and Latin American Headquarters Brocade Communications Systems, Inc. 130 Holger Way San Jose, CA 95134 Tel: 1-408-333-8000 Fax: 1-408-333-8101 E-mail: info@brocade.com
European Headquarters Brocade Communications Switzerland Sàrl Centre Swissair Tour B - 4ème étage 29, Route de l'Aéroport Case Postale 105 CH-1215 Genève 15 Switzerland Tel: +41 22 799 5640 Fax: +41 22 799 5641 E-mail: emea-info@brocade.com
Asia-Pacific Headquarters Brocade Communications Systems China HK, Ltd. No. 1 Guanghua Road Chao Yang District Units 2718 and 2818 Beijing 100020, China Tel: +8610 6588 8888 Fax: +8610 6588 9999 E-mail: china-info@brocade.com
Asia-Pacific Headquarters Brocade Communications Systems Co., Ltd. (Shenzhen WFOE) Citic Plaza No. 233 Tian He Road North Unit 1308 – 13th Floor Guangzhou, China Tel: +8620 3891 2000 Fax: +8620 3891 2111 E-mail: china-info@brocade.com
Document History
Document Title Publication Number Summary of Changes Date
Brocade 5300 Hardware Reference Manual 53-1000858-01 New document March 2008
Brocade 5300 Hardware Reference Manual 53-1000858-02 Document update July 2008
Brocade 5300 Hardware Reference Manual 53-1000858-03 BSMI statement updated October 2011
Brocade 5300 Hardware Reference Manual 53-1000858-04 Chinese regulatory
statement added
May 2012
Page 3

Contents

About This Document
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . vii
What’s new in this document. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Document conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Text formatting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Command syntax conventions . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Notes, cautions, and warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Key terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Notice to the reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Additional information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Brocade resources. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x
Other industry resources. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x
Getting technical help. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x
Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
Chapter 1 Brocade 5300 Introduction
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Brocade 5300 overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Port side of the Brocade 5300. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Non-port side of the Brocade 5300. . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Ports on Demand license . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Brocade Inter-Switch Link (ISL) Trunking. . . . . . . . . . . . . . . . . . . . . . . 5
Chapter 2 Brocade 5300 Installation and Configuration
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Items included with the Brocade 5300. . . . . . . . . . . . . . . . . . . . . . . . 7
Installation and safety considerations. . . . . . . . . . . . . . . . . . . . . . . . . 7
Electrical considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Environmental considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Cabinet considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Recommendations for cable management . . . . . . . . . . . . . . . . . 8
Items required for installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installing a standalone Brocade 5300 . . . . . . . . . . . . . . . . . . . . . . . . 9
Brocade 5300 Hardware Reference Manual iii 53-1000858-04
Page 4
Cabinet installation for a Brocade 5300 . . . . . . . . . . . . . . . . . . . . . . 10
Brocade 5300 configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Providing power to the switch . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Creating a serial connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Switch IP address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Date and time settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Chapter 3 Brocade 5300 Operation
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Powering the Brocade 5300 on and off . . . . . . . . . . . . . . . . . . . . . . 17
LED activity interpretation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Brocade 5300 LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
LED locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
LED patterns. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
POST and boot specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
POST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Boot. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Interpreting POST results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Brocade 5300 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Installing an SFP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Field Replaceable Units (FRUs). . . . . . . . . . . . . . . . . . . . . . . . . . 25
Brocade 5300 Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Appendix A Brocade 5300 Specifications
In this appendix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Switch components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Weight and physical dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Facility requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Power supply specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Environmental requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
General specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Data transmission ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Memory specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Fibre Channel port specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Serial port specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
iv Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 5
Index
Regulatory compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
FCC warning (US only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
KCC statement (Republic of Korea) . . . . . . . . . . . . . . . . . . . . . .33
VCCI statement Japan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Power cords (Japan Denan). . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
China statement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
BSMI statement (Taiwan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
CE statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Canadian requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Laser compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
RTC battery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Electrical safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Regulatory certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Environmental regulation compliance. . . . . . . . . . . . . . . . . . . . . . . . 37
China RoHS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Brocade 5300 Hardware Reference Manual v 53-1000858-04
Page 6
vi Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 7

About This Document

In this chapter
How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Supported hardware and software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Notice to the reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Additional information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Getting technical help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x
Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
How this document is organized
This document is organized to help you find the information that you want as quickly and easily as possible.
The document contains the following components:
Chapter 1, “Brocade 5300 Introduction,” provides an overview of the Brocade 5300 switch, a
feature list, and a look at the appearance of the switch.
Chapter 2, “Brocade 5300 Installation and Configuration,” provides the information needed to
install the switch into your network.
Chapter 3, “Brocade 5300 Operation” discusses the day-to-day operational procedures for
using the switch.
Appendix A, “Brocade 5300 Specifications”provides tables of physical, environmental, and
general specifications, helpful for quick lookup.
The index points you to the exact pages on which specific information is located.
Supported hardware and software
Although many different software and hardware configurations are tested and supported by Brocade Communications Systems, Inc. for Fabric OS v6.1.0, documenting all possible configurations and scenarios is beyond the scope of this document.
This document is specific to the Brocade 5300 and Fabric OS v5.3.0. To obtain information about a Fabric OS version other than v5.3.0, see the documentation specific to that OS version.
Brocade 5300 Hardware Reference Manual vii 53-1000858-04
Page 8
What’s new in this document
The Chinese regulatory statement has been added. “China statement.”
Document conventions
This section describes text formatting conventions and important notice formats used in this document.
Text formatting
The narrative-text formatting conventions that are used are as follows:
bold text Identifies command names
Identifies the names of user-manipulated GUI elements Identifies keywords and operands Identifies text to enter at the GUI or CLI
italic text Provides emphasis
Identifies variables Identifies paths and Internet addresses Identifies document titles
code text Identifies CLI output
Identifies command syntax examples
For readability, command names in the narrative portions of this guide are presented in mixed lettercase: for example, switchShow. In actual examples, command lettercase is often all lowercase. Otherwise, this manual specifically notes those cases in which a command is case sensitive.
Command syntax conventions
Command syntax in this manual follows these conventions:
command Commands are printed in bold.
--option, option Command options are printed in bold.
-argument, arg Arguments.
[ ] Optional element.
variable Variables are printed in italics. In the help pages, values are underlined
enclosed in angled brackets < >.
... Repeat the previous element, for example “member[;member...]”
value Fixed values following arguments are printed in plain font. For example,
--show WWN
or
| Boolean. Elements are exclusive. Example:
viii Brocade 5300 Hardware Reference Manual
--show -mode egress | ingress
53-1000858-04
Page 9
Notes, cautions, and warnings
NOTE
ATTENTION
CAUTION
DANGER
The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards.
A note provides a tip, guidance or advice, emphasizes important information, or provides a reference to related information.
An Attention statement indicates potential damage to hardware or data.
A Caution statement alerts you to situations that can be potentially hazardous to you.
A Danger statement indicates conditions or situations that can be potentially lethal or extremely hazardous to you. Safety labels are also attached directly to products to warn of these conditions or situations.
Key terms
For definitions specific to Brocade and Fibre Channel, see the Brocade Glossary.
For definitions of SAN-specific terms, visit the Storage Networking Industry Association online dictionary at:
http://www.snia.org/education/dictionary
Notice to the reader
This document may contain references to the trademarks of the following corporations. These trademarks are the properties of their respective companies and corporations.
These references are made for informational purposes only.
Corporation Referenced Trademarks and Products
IBM Corporation IBM, FICON, PowerPC
Additional information
This section lists additional Brocade and industry-specific documentation that you might find helpful.
Brocade 5300 Hardware Reference Manual ix 53-1000858-04
Page 10
Brocade resources
To get up-to-the-minute information, join Brocade Connect. It’s free! Go to http://www.brocade.com and click Brocade Connect to register at no cost for a user ID and password.
For practical discussions about SAN design, implementation, and maintenance, you can obtain
Building SANs with Brocade Fabric Switches through:
http://www.amazon.com
For additional Brocade documentation, visit the Brocade SAN Info Center and click the Resource Library location:
http://www.brocade.com
Release notes are available on the Brocade Connect Web site and are also bundled with the Fabric OS firmware.
Other industry resources
White papers, online demos, and data sheets are available through the Brocade Web site at
http://www.brocade.com/products/software.jhtml.
Best practice guides, white papers, data sheets, and other documentation is available through
the Brocade Partner Web site.
For additional resource information, visit the Technical Committee T11 Web site. This Web site provides interface standards for high-performance and mass storage applications for Fibre Channel, storage management, and other applications:
http://www.t11.org
For information about the Fibre Channel industry, visit the Fibre Channel Industry Association Web site:
http://www.fibrechannel.org
Getting technical help
Contact your switch support supplier for hardware, firmware, and software support, including product repairs and part ordering. To expedite your call, have the following information available:
1. General Information
Switch model
Switch operating system version
Error numbers and messages received
supportSave command output
Detailed description of the problem, including the switch or fabric behavior immediately
following the problem, and specific questions
Description of any troubleshooting steps already performed and the results
Serial console and Telnet session logs
syslog message logs
x Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 11
2. Switch Serial Number
The switch serial number and corresponding bar code are provided on the serial number label, as illustrated below.:
*FT00X0054E9*
FT00X0054E9
The serial number label is located as follows:
Brocade 200E—On the non-port side of the chassis
Brocade 300, 4100, 4900, 5100, 5300, 7500, and Brocade Encryption Switch—On the
switch ID pull-out tab located inside the chassis on the port side on the left
Brocade 5000—On the switch ID pull-out tab located on the bottom of the port side of the
switch
Brocade 7600—On the bottom of the chassis
Brocade 48000—Inside the chassis next to the power supply bays
Brocade DCX—On the bottom right on the port side of the chassis
3. World Wide Name (WWN)
Use the wwn command to display the switch WWN.
If you cannot use the wwn command because the switch is inoperable, you can get the WWN from the same place as the serial number, except for the Brocade DCX. For the Brocade DCX, access the numbers on the WWN cards by removing the Brocade logo plate at the top of the non-port side of the chassis.
Document feedback
Quality is our first concern at Brocade and we have made every effort to ensure the accuracy and completeness of this document. However, if you find an error or an omission, or you think that a topic needs further development, we want to hear from you. Forward your feedback to:
documentation@brocade.com
Provide the title and version number of the document and as much detail as possible about your comment, including the topic heading and page number and your suggestions for improvement.
Brocade 5300 Hardware Reference Manual xi 53-1000858-04
Page 12
xii Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 13
Chapter

Brocade 5300 Introduction

In this chapter

Brocade 5300 overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Port side of the Brocade 5300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Non-port side of the Brocade 5300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Ports on Demand license . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Brocade Inter-Switch Link (ISL) Trunking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Brocade 5300 overview

The Brocade 5300 is an 80-port 1, 2, 4, or 8 Gbps Fibre Channel switch that delivers Brocade sixth generation ASIC technology and architecture for Fibre Channel Storage Area Networks (SANs). The Brocade 5300 is designed for the needs of enterprise environments that require a high-port footprint for por t aggregation.
1
With its high auto-sensing port count and ports-on-demand flexibility, the Brocade 5300 is an ideal solution as a fan-out switch from a director core, or as the core switch in a fabric. The Brocade 5300 satisfies demanding Reliability, Availability, and Serviceability (RAS), performance and scalability requirements of an enterprise switch while delivering interoperability and ease-of-use advantages found only in the Brocade product family. The Brocade 5300 is the latest enterprise offering from the Brocade family of entry-to-enterprise products, and offers the following features and capabilities:
Up to 80 auto-sensing ports of high-performance 8 Gbps technology in a single domain.
Ports On Demand scaling from 48 to 64 or 80 ports.
Full 1:1 subscription on all 80 ports at 8 Gbps.
1, 2, 4 and 8 Gbps auto-sensing Fibre Channel switch and router ports.
FICON and FICON Control Unit Port ready.
Fibre Channel Routing (FCR) service, which provides improved scalability and fault isolation,
along with multi-vendor interoperability through the optional Integrated Routing license.
Two hot-swappable, redundant power supply FRUs.
Three hot-swappable fan FRUs in an N+1 configuration to provide hardware-redundant cooling.
Universal ports that self-configure as E, F, M or FL ports. Ex_Ports are activated on a per port
basis with the optional Integrated Routing license.
An RJ45 Ethernet management port, in conjunction with EZSwitchSetup, that supports switch
IP address discovery and configuration, eliminating the need to attach a serial cable to configure the switch IP address and greatly increasing the ease of use.
USB port that provides storage for firmware updates, output of the supportSave command and
storage for configuration uploads and downloads.
Brocade 5300 Hardware Reference Manual 1 53-1000858-04
Page 14

Port side of the Brocade 5300

1
A system motherboard that features a Freescale MPC8548 Reduced Instruction Set Computer
Inter-Switch Link (ISL) Trunking (licensable), which allows up to eight ports (at 1, 2, 4, or 8 Gbps
Dynamic Path Selection (DPS), which optimizes fabric-wide performance and load balancing by
Rack-mount design using existing rail kits (fixed, sliding, and mid-mount/Telco rail kits) on a
Industry-leading extended distance support, which enables native Fibre Channel extension
Brocade Small Form-Factor Pluggable (SFP) or SFP+ optical transceivers that support any
Unicast, multicast (255 groups), and broadcast data traffic type support.
Brocade Fabric Operating System (FOS), which delivers distributed intelligence throughout the
Port-to-port latency minimized to 2100 nanoseconds through the use of cut-through frame
Extensive diagnostics and system-monitoring capabilities for enhanced high Reliability,
The Brocade EZSwitchSetup wizard that makes SAN configuration a three-step point-and-click
(RISC) CPU running at 1.3 GHz with integrated peripherals, and that provides high performance with low power consumption.
speeds) between a pair of switches combined to form a single, logical ISL with a speed of up to 64 Gbps (128 Gbps full duplex) for optimal bandwidth utilization and load balancing.
automatically routing data to the most efficient available path in the fabric.
19” EIA rack.
greater than 590 km (366 miles).
combination of Short Wavelength (SWL), Long Wavelength (LWL), or Extended Long Wavelength (ELWL) optical media among the switch ports.
network and enables a wide range of value-added applications including Brocade Advanced Web Tools and Brocade Zoning. Optional Fabric Services include: Adaptive Networking with QoS, Brocade Extended Fabrics, Brocade Enhanced Group Management, Brocade Fabric Watch, ISL Trunking, Integrated Routing, and End-to-End Performance Monitoring (APM).
routing at 8 Gbps.
Availability, and Serviceability (RAS)
task.
Port side of the Brocade 5300
The port side of the Brocade 5300 includes the system status LED, console port, Ethernet port and LEDs, USB port, and Fibre Channel ports and the corresponding port status LEDs.
Figure 1 shows the port side of the Brocade 5300.
2 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 15

Non-port side of the Brocade 5300

1
2
7345 8 9 10
13 14 15 16
11 12
6
1
FIGURE 1 Port side view of the Brocade 5300
1 Brocade 5300 9 FC ports 16-23
2 Switch ID pull-out tab 10 FC ports 24-31
3 System status LED (top) 11 FC ports 32-38
System power LED (bottom)
4 Console port 13 FC ports 48-55
5 Ethernet port 14 FC ports 56-63
6 USB port 15 FC ports 64-71
7 FC ports 0-7 16 FC ports 72-79
8FC ports 8-15
Non-port side of the Brocade 5300
Figure shows the non-port side of the Brocade 5300, which contains the power supplies (including
the AC power receptacle and AC power switch) and fans.
12 FC ports 40-47
Brocade 5300 Hardware Reference Manual 3 53-1000858-04
Page 16

Ports on Demand license

1
2
3 7
4
5 6
1
FIGURE 2 Non-port side of the Brocade 5300
1 Brocade 5300 5 Fan assembly #2
2 Non-port side of switch 6 Fan assembly #1
3 Power supply #2 7 Power supply #1
4 Fan assembly #3
Ports on Demand license
The Brocade 5300 has 80 ports. By default, ports 0-47 are enabled. As your needs increase, you can activate unlicensed ports by purchasing and installing the Brocade Ports on Demand (POD) optional licensed product. After it has been installed, the license appears in the licenseShow command output as Ports on Demand license.
To install a Ports on Demand license, you can either use the supplied license key or generate a license key. Typically the switch is shipped with a paper pack that specifies the transaction key to use with the Software License Keys link. Use this transaction key on the Brocade Web site at www.brocade.com/licensekeys and follow the instructions to generate the key. You can also use this site to generate other license keys for your switch.
4 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 17
After you have installed the license keys, you must enable the ports. You can do so without disrupting switch operation by using the portEnable command on each port individually. Alternatively, you can disable and re-enable the switch to activate all ports simultaneously.
For detailed information on enabling additional ports using the Ports on Demand license, refer to the Fabric OS Administrator’s Guide.

Brocade Inter-Switch Link (ISL) Trunking

Brocade ISL Trunking is optional software that allows you to create trunking groups of ISLs between adjacent switches. Each eight port group on the Brocade 5300 can be used as a trunking group. For more information about Brocade ISL Trunking, see the Fabric OS Administrator’s Guide.
Brocade Inter-Switch Link (ISL) Trunking
1
Brocade 5300 Hardware Reference Manual 5 53-1000858-04
Page 18
Brocade Inter-Switch Link (ISL) Trunking
1
6 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 19
Chapter

Brocade 5300 Installation and Configuration

In this chapter

Items included with the Brocade 5300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installation and safety considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installing a standalone Brocade 5300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Cabinet installation for a Brocade 5300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Brocade 5300 configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Items included with the Brocade 5300

The following items are included with the standard shipment of the Brocade 5300. When you open the Brocade 5300 packaging, verify that these items are included in the package and that no damage has occurred during shipping:
The Brocade 5300 switch, containing three fan assemblies and two power supplies
One accessory kit, containing the following items:
Serial cable with an RJ-45 connector
6 ft. Power Cord
Rubber feet, required for setting up the switch as a standalone unit
Brocade Family Doc CD
Brocade 5300 QuickStart Guide
EZSwitch Setup CD
2

Installation and safety considerations

You can install the Brocade 5300 switch in the following ways:
1. As a standalone unit on a flat surface.
2. In an EIA cabinet using a fixed-rail rack mount kit. The optional fixed-rail rack mount kit can be ordered from your switch retailer.
3. In an EIA cabinet using an optional slide-rail rack mount kit. The optional slide-rail rack mount kit can be ordered from your switch retailer.
4. In an EIA cabinet using an optional mid-mount rack kit for switches. The optional mid-mount rack kit for switches can be ordered from your switch retailer.
Brocade 5300 Hardware Reference Manual 7 53-1000858-04
Page 20
Installation and safety considerations
2

Electrical considerations

To install and operate the switch successfully, ensure the following:
The primary outlet is correctly wired, protected by a circuit breaker, and grounded in
accordance with local electrical codes.
The supply circuit, line fusing, and wire size are adequate, as specified by the electrical
rating on the switch nameplate.
The power supply standards provided in Table 6, “Power Supply Specifications” on
page 28 are met.

Environmental considerations

For successful installation and operation of the switch, ensure that the following environmental requirements are met:
At a minimum, adequate cooling requires that you install the switch with the non-port side,
which contains the air intake vents, facing the cool-air aisle.
All equipment in the rack should force air in the same direction to avoid intake of exhaust
air.
A maximum of 102 cubic meters/hour (60 cubic feet/minute) and a minimum of 74.8
cubic meters/hour (44 cubic feet/minute) of air flow is available to the air intake vents on the non-port side of the switch.
The ambient air temperature does not exceed 40 C (104 F) while the switch is operating.

Cabinet considerations

For successful installation and operation of the switch in a cabinet, ensure the following cabinet requirements are met:
The cabinet must be a standard EIA cabinet.
Plan a cabinet space that is one rack unit (1U) high; 4.45 cm (1.75 inches) high and 48.3
cm (19 inches) wide.
Ground all equipment in the cabinet through a reliable branch circuit connection and
maintain ground at all times. Do not rely on a secondary connection to a branch circuit, such as a power strip.
Ensure that airflow and temperature requirements are met on an ongoing basis,
particularly if the switch is installed in a closed or multicabinet assembly.
Verify that the additional weight of the switch does not exceed the cabinet’s weight limits
or unbalance the cabinet in any way.
Secure the cabinet to ensure stability in case of unexpected movement, such as an
earthquake.

Recommendations for cable management

The minimum bend radius for a 50 micron cable is 2 inches under full tensile load and 1.2 inches with no tensile load.
8 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 21

Installing a standalone Brocade 5300

NOTE
Cables can be organized and managed in a variety of ways, for example, using cable channels on the sides of the cabinet or patch panels to minimize cable management. Following is a list of recommendations:
You should not use tie wraps with optical cables because they are easily overtightened and can damage the optic fibers.
2
Plan for rack space required for cable management before installing the switch.
Leave at least 1 m (3.28 ft) of slack for each port cable. This provides room to remove and
replace the switch, allows for inadvertent movement of the rack, and helps prevent the cables from being bent to less than the minimum bend radius.
If you are using Brocade ISL Trunking, consider grouping cables by trunking groups. The
cables used in trunking groups must meet specific requirements, as described in the Fabric OS Administrator’s Guide.
For easier maintenance, label the fiber optic cables and record the devices to which they
are connected.
Keep LEDs visible by routing port cables and other cables away from the LEDs.
Use hook and loop style straps to secure and organize fiber optic cables.

Items required for installation

The following items are required for installing, configuring, and connecting the Brocade 5300 for use in a network and fabric:
Workstation with an installed terminal emulator, such as HyperTerminal
Unused IP address and corresponding subnet mask and gateway address
Serial cable (provided)
Ethernet cable
SFPs and compatible cables, as required
Access to an FTP server for backing up the switch configuration (optional)
Installing a standalone Brocade 5300
Perform this task to install the Brocade 5300 as a standalone unit.
1. Unpack the Brocade 5300 and verify the items listed on “Items included with the Brocade
5300” on page 7. Verify the items are present and undamaged.
2. Apply the adhesive rubber feet. Applying the rubber feet onto the switch helps prevent the switch from sliding off the supporting surface.
a. Clean the indentations at each corner of the bottom of the switch to ensure that they are
free of dust or other debris that might lessen the adhesion of the feet.
b. With the adhesive side against the chassis, place one rubber foot in each indentation and
press into place.
3. Place the switch on a flat, sturdy surface.
4. Provide power to the switch as described in “Providing power to the switch” on page 10.
Brocade 5300 Hardware Reference Manual 9 53-1000858-04
Page 22

Cabinet installation for a Brocade 5300

ATTENTION
ATTENTION
2
Do not connect the switch to the network until the IP address is correctly set. For instructions on how to set the IP address, see “Brocade 5300 configuration”
Cabinet installation for a Brocade 5300
Follow the installation instructions shipped with the appropriate rack mount kit:
To install the switch into a fixed-rail rack, refer to the Fixed Rack Mount Kit Installation
Procedure.
To install the switch into a slide-rail rack, refer to the Slide Rack Mount Kit Installation
Procedure.
To install the switch into mid-mount rack, refer to the Mid-Mount Rack Mount Kit (Switch)
Installation Procedure.

Brocade 5300 configuration

Once you have set up the Brocade 5300 in a rack or as a standalone switch, it is time to give it power and a basic configuration. If you are going to use the Brocade 5300 in a single-switch setup, you can use EZSwitchSetup to complete the basic configuration.
See the EZSwitchSetup CD, included with the Brocade 5300 for more information. You can also use the Brocade 5300 Quick Start Guide.
If you do not want to use EZSwitch Setup, follow the instructions in the rest of this section.

Providing power to the switch

Perform the following steps to provide power to the Brocade 5300.
1. Connect the power cords to both power supplies, and then to power sources on separate circuits to protect against AC failure. Ensure that the cords have a minimum service loop of 6 in. available and are routed to avoid stress.
2. Power on the power supplies by flipping both AC switches to the “1” symbol. The power supply LEDs display amber until POST is complete, and then change to green. The switch usually requires from 1 to 3 min to boot and complete POST.
Power is supplied to the switch as soon as the first power supply is connected and turned on.
3. After POST is complete, verify that the switch power and status LEDs on the left of the port side of the switch are green.

Creating a serial connection

You will perform all configuration tasks in this guide using a serial connection.
Complete the following steps to create a serial connection to the switch.
10 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 23
Brocade 5300 configuration
1. Connect the serial cable to the serial port on the switch and to an RS-232 serial port on the workstation.
If the serial port on the workstation is RJ-45 instead of RS-232, remove the adapter on the end of the serial cable and insert the exposed RJ-45 connector into the RJ-45 serial port on the workstation.
2. Open a terminal emulator application (such as HyperTerminal on a PC, or TERM, TIP, or Kermit in a UNIX environment), and configure the application as follows:
2
In a Windows environment:
Parameter Value
Bits per second 9600
Databits 8
Parity None
Stop bits 1
Flow control None
In a UNIX environment, enter the following string at the prompt:
tip /dev/ttyb -9600.
If ttyb is already in use, use ttya instead and enter the following string at the prompt:
tip /dev/ttya -9600

Switch IP address

You can configure the Brocade 5300 with a static IP address, or you can use a DHCP (Dynamic Host Configuration Protocol) server to set the IP address of the switch. DHCP is enabled by default. The Brocade 5300 supports both IPv4 and IPv6.
Using DHCP to set the IP address
When using DHCP, the Brocade 5300 obtains its IP address, subnet mask, and default gateway address from the DHCP server. The DHCP client can only connect to a DHCP server that is on the same subnet as the switch. If your DHCP server is not on the same subnet as the Brocade 5300, use a static IP address.
Setting a static IP address
1. Log into the switch using the default password, which is password.
2. Use the ipaddrset command to set the Ethernet IP address.
If you are going to use an IPv4 IP address, enter the IP address in dotted decimal notation as prompted.
Ethernet IP Address: [192.168.74.102]
If you are going to use an IPv6 address, enter the network information in semicolon-separated notation as prompted.
switch:admin> ipaddrset -ipv6 --add 1080::8:800:200C:417A/64
Brocade 5300 Hardware Reference Manual 11 53-1000858-04
Page 24
Brocade 5300 configuration
2
3. Complete the rest of the network information as prompted.
4. Enter off to Disable DHCP when prompted.

Date and time settings

The Brocade 5300 maintains the current date and time inside a battery-backed real-time clock (RTC) circuit. Date and time are used for logging events. Switch operation does not depend on the date and time; a Brocade 5300 with an incorrect date and time value still functions properly. However, because the date and time are used for logging, error detection, and troubleshooting, you should set them correctly.
Time zones
You can set the time zone for the switch by name. You can also set country, city or time zone parameters.
IP address is being changed...Done.
Ethernet Subnetmask: [255.255.255.0]
Ethernet IP Address: [192.168.74.102] Ethernet Subnetmask: [255.255.255.0]
DHCP [OFF]: off
If the time zone is not set with the new options, the switch retains the offset time zone settings. The tsTimeZone command includes an option to revert to the prior time zone format. For more information about the
You can set the time zone for a switch using the tsTimeZone command. The tsTimeZone command allows you to perform the following tasks:
--old option, see the Fabric OS Command Reference.
Display all of the time zones supported in the firmware
Set the time zone based on a country and city combination or based on a time zone ID such as
PST
The time zone setting has the following characteristics:
You can view the time zone settings. However, only those with administrative permissions can
set the time zones.
The tsTimeZone setting automatically adjusts for Daylight Savings Time.
Changing the time zone on a switch updates the local time zone setup and is reflected in local
time calculations.
By default, all switches are in the GMT time zone (0,0). If all switches in a fabric are in one time
zone, it is possible for you to keep the time zone setup at the default setting.
System services that have already started will reflect the time zone changes only after the next
reboot.
Time zone settings persist across failover for high availability.
12 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 25
Brocade 5300 configuration
2
Local time synchronization
You can synchronize the local time of the principal or primary fabric configuration server (FCS) switch to a maximum of eight external network time protocol (NTP) servers. To keep the time in your SAN current, it is recommended that the principal or primary FCS switch has its time synchronized with at least one external NTP server. The other switches in the fabric will automatically take their time from the principal or primary FCS switch.
All switches in the fabric maintain the current clock server value in non-volatile memory. By default, this value is the local clock server <LOCL> of the principal or primary FCS switch. Changes to the clock server value on the principal or primary FCS switch are propagated to all switches in the fabric.
When a new switch enters the fabric, the time server daemon of the principal or primary FCS switch sends out the addresses of all existing clock servers and the time to the new switch. If a switch with v5.3.0 or later has entered the fabric it will be able to store the list and the active servers; pre-5.3.0 Fabric OS switches will ignore the new list parameter in the payload and will update only the active server address.
If the active NTP server configured is IPv6, then distributing the same in the fabric will not be possible to switches earlier than v5.3.0 because IPv6 is supported for Fabric OS version 5.3.0 and later. The default value LOCL will be distributed to pre-5.3.0 switches.
The tsClockServer command accepts multiple server addresses in either IPv4, IPv6, or DNS name formats. When multiple NTP server addresses are passed, tsclockserver sets the first obtainable address as the active NTP server. The rest are stored as backup servers that can take over if the active NTP server fails. The principal or primary FCS switch synchronizes its time with the NTP server every 64 seconds.
Setting the date
1. Log into the switch using the default password, which is password.
2. Enter the date command, using the following syntax:
date "mmddHHMMyy"
The values are:
mm is the month; valid values are 01 through 12.
dd is the date; valid values are 01 through 31.
HH is the hour; valid values are 00 through 23.
MM is minutes; valid values are 00 through 59.
yy is the year; valid values are 00 through 99 (values greater than 69 are interpreted as
1970 through 1999, and values less than 70 are interpreted as 2000-2069).
switch:admin> date Fri Sep 29 17:01:48 UTC 2007 switch:admin> date "0927123007" Thu Sep 27 12:30:00 UTC 2007 switch:admin>
Brocade 5300 Hardware Reference Manual 13 53-1000858-04
Page 26
Brocade 5300 configuration
2
Setting time zones
You must perform the procedure on all switches for which the time zone must be set. However, you only need to set the time zone once on each switch, because the value is written to nonvolatile memory.
Use one of the two following procedures to set the time zone.
The following procedure describes how to set the current time zone using timezone_fmt mode to Central Standard time.
1. Log into the switch using the default password, which is password.
2. Enter the tsTimeZone command as follows:
switch:admin> tstimezone [--interactive]/ [, timezone_fmt]
Use timezone_fmt to set the time zone by Country/City or by time zone ID, such as PST.
The following example shows how to change the time zone to US/Central.
switch:admin> tstimezone Time Zone : US/Pacific switch:admin> tstimezone US/Central switch:admin> tstimezone Time Zone : US/Central
The following procedure describes how to set the current time zone using interactive mode to Pacific Standard Time.
1. Type the tsTimeZone command as follows:
switch:admin> tstimezone --interactive
2. You are prompted to select a general location.
Please identify a location so that time zone rules can be set correctly.
3. Enter the appropriate number or Ctrl-D to quit.
4. At the prompt, select a country location.
5. At the prompt, enter the appropriate number to specify the time zone region or Ctrl-D to quit.
Synchronizing local time using NTP
Perform the following steps to synchronize the local time using NTP.
1. Log into the switch using the default password, which is password.
2. Enter the tsClockServer command:
switch:admin> tsclockserver "<ntp1;ntp2>"
where ntp1 is the IP address or DNS name of the first NTP server, which the switch must be able to access. The second ntp2 is the second NTP server and is optional. The operand “<ntp1;ntp2>” is optional; by default, this value is LOCL, which uses the local clock of the principal or primary switch as the clock server.
switch:admin> tsclockserver LOCL switch:admin> tsclockserver "132.163.135.131"
14 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 27
Brocade 5300 configuration
switch:admin> tsclockserver
132.163.135.131 switch:admin>
2
The following example shows how to set up more than one NTP server using a DNS name:
switch:admin> tsclockserver "10.32.170.1;10.32.170.2;ntp.localdomain.net" Updating Clock Server configuration...done. Updated with the NTP servers
Changes to the clock server value on the principal or primary FCS switch are propagated to all switches in the fabric.
Brocade 5300 Hardware Reference Manual 15 53-1000858-04
Page 28
Brocade 5300 configuration
2
16 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 29
Chapter

Brocade 5300 Operation

In this chapter

Powering the Brocade 5300 on and off. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
LED activity interpretation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
POST and boot specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Interpreting POST results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Brocade 5300 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Brocade 5300 Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Powering the Brocade 5300 on and off

Complete the following steps to power the Brocade 5300 on.
1. Connect one or both power cords to the power connectors on the power supplies and to a power source
3
2. Set the AC power switches to “I”.
Power is supplied to the switch as soon as the first power supply is connected and powered on.
The switch runs POST by default each time it is powered on; it can take up to several minutes to boot and complete POST.
To power the Brocade 5300 off, power off both power supplies by setting each AC power switch to
O”. All devices are returned to their initial state the next time the switch is powered on.

LED activity interpretation

System activity and status can be determined through the activity of the LEDs on the switch.
There are three possible LED states: no light, a steady light, and a flashing light. The lights are green or amber.
Sometimes, the LEDs flash either of the colors during boot, POST, or other diagnostic tests. This is normal; it does not indicate a problem unless the LEDs do not indicate a healthy state after all boot processes and diagnostic tests are complete.

Brocade 5300 LEDs

The Brocade 5300 has the following LEDs:
One system status LED (above) on the left side.
One power status LED (below) on the left side.
Brocade 5300 Hardware Reference Manual 17 53-1000858-04
Page 30
LED activity interpretation
1
2
7
65
3
4
11
8 9
12
10
13
3
Two E t h e r n e t Po r t LEDs
One port status LED for each port on the switch. These LEDs are arrayed below each pair of
Fibre Channel ports. The port LEDs are located in the array in the same relative positions as the ports.
One power supply LED above the AC power switch on each power supply on the non-port side
of the switch
One fan status LED at the bottom of each fan assembly on the non-port side of the switch

LED locations

Figure 3 shows the port side of the Brocade 5300.
18 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 31
LED activity interpretation
7
12
3
8910
456
1 Brocade 5300 8 FC port status LED (port 0)
2 System status LED 9 FC port status LED (port 4)
3 System power LED 10 FC ports (0 through 7)
4 Console port 11 FC port status LED (port 48)
5 Ethernet port 12 FC port status LED (port 52)
6 Ethernet speed LED 13 FC ports (53 through 55)
7 Ethernet link LED
FIGURE 3 LEDs on Port Side of Brocade 5300
Figure 4 shows the non-port side of the switch.
3
1 Power supply #2 status LED 6 Power supply #1 status LED
2 Power supply #2 7 Power supply #1
3 Fan assembly #3 8 Fan assembly #3 status LED
4 Fan assembly #2 9 Fan assembly #2 status LED
5 Fan assembly #1 10 Fan assembly #1 status LED
FIGURE 4 LEDs on non-port side of Brocade 5300
Brocade 5300 Hardware Reference Manual 19 53-1000858-04
Page 32
LED activity interpretation
3

LED patterns

Tab le 1 describes the LEDs and their actions on the port side of the switch.
TABLE 1 Port side LED patterns during normal operation
LED name LED color Status of hardware Recomended action
Power Status No light System is off or there is an internal
power supply failure.
Steady green System is on and power supplies are
functioning properly.
System Status No light System is off or there is no power. Verify the system is on and has
Steady green System is on and functioning
properly.
Steady amber (for more than five seconds)
Flashing amber/green
Ethernet Speed
Ethernet Link No light There is no link. Verify the Ethernet cable is
No light Port speed is 10 Mbps. No action required.
Steady green Port speed is 100 Mbps. No action required.
Steady amber There is a link. No action required.
Flickering amber There is link activity (traffic). No action required.
Unknown state, boot failed, or the system is faulty.
This LED displays steady amber during POST, this is normal and does not indicate a fault.
Attention is required. A number of variables can cause this status including a single power supply failure, a fan failure, or one or more environmental ranges has exceeded.
Verify the system is powered on (power supply switches to “1”), the power cables attached, and your power source is live.
If the system power LED is not green, the unit may be faulty. Contact your switch service provider.
No action required.
completed booting.
No action required.
Perform the following steps: Connect a serial cable to the system. Reboot the system. Check the failure indicated on the
system console. Contact your switch service provider.
Check the management interface and the error log for details on the cause of status.
Contact your switch service provider.
connected correctly.
20 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 33
LED activity interpretation
TABLE 1 Port side LED patterns during normal operation (Continued)
LED name LED color Status of hardware Recomended action
3
Port Status No light No signal or light carrier (media or
cable) detected.
Slow flashing green (flashing in 2-second intervals)
Fast flashing green (flashing in half-second intervals)
Flickering green (steady with random flashes)
Steady green Port is online, but has no traffic. No action required.
Slow flashing amber (flashing in 2-second intervals)
Fast flashing amber (flashing in half-second intervals)
Steady amber (for more than 5 seconds)
Port is online but segmented because of a loopback cable or incompatible switch connection.
Port is online and an internal loopback diagnostic test is running.
Port is online and frames are flowing through the port.
Port is disabled (because of diagnostics or the portDisable command).
Port is faulty. Check the management interface
Port is receiving light or signal carrier at 4 Gbps; but is not yet online.
Check transceiver and cable.
No action required.
No action required.
No action required.
Verify the diagnostic tests are not running. Re-enable the port using the portEnable command.
and the error log for details on the cause of status. Contact your switch service provider.
No action required.
Tab le 2 describes the LEDs on the non-port side of the switch.
TABLE 2 Non-port side LED patterns during normal operation
LED name LED color Status of hardware Recomended action
Power Supply Status
No light Power supply is not receiving
power or is off.
Steady green Power supply is operating
normally.
Steady amber (for more than 5 seconds)
Power supply fault for one of the following reasons: Power supply is switched off
The power cable is disconnected The power supply has failed Note: When the switch is first
powered on the power supply status LED will show amber until POST has completed.
Verify the power supply is on and seated and the power cord is connected to a functioning power source.
No action required.
Try th e fol l owin g : Check the power cable connection. Verify that the power supply is powered on. Replace the power supply FRU.
Brocade 5300 Hardware Reference Manual 21 53-1000858-04
Page 34

POST and boot specifications

3
TABLE 2 Non-port side LED patterns during normal operation (Continued)
LED name LED color Status of hardware Recomended action
Fan Status No light Fan assembly is not receiving
Steady green Fan assembly is operating
Steady amber (for more than 5 seconds)
POST and boot specifications
When the switch is turned on or rebooted, the switch performs POST. Total boot time with POST can be several minutes. POST can be omitted after subsequent reboots by using the fastboot command or entering the diagDisablePost command to persistently disable POST.
For more information about these commands, refer to the Fabric OS Command Reference Manual.
power.
normally.
Fan fault for one of the following reasons:
One or more of the fan(s) in the fan assembly has failed The fan FRU was disabled by the user
Note: When the switch is first powered on the fan status LED will show amber until POST has completed.
Try th e fol l owin g : Verify the fan FRU is seated correctly. Verify the switch is powered on.
No action required.
Try th e fol l owin g : Verify the fan FRU is enabled (use the
fanEnable command). Replace the fan FRU.

POST

The success or failure results of the diagnostic tests that run during POST can be monitored through LED activity, the error log, or the command line interface.
POST includes the following tasks:
1. Conducts preliminary POST diagnostics.
2. Initializes the operating system.
3. Initializes hardware.
4. Runs diagnostic tests on several functions, including circuitry, port functionality, memory, statistics counters, and serialization.

Boot

In addition to POST, boot includes the following tasks after POST is complete:
1. Performs universal port configuration.
2. Initializes links.
3. Analyzes fabric. If any ports are connected to other switches, the switch participates in a fabric configuration.
4. Obtains a domain ID and assigning port addresses.
22 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 35
5. Constructs unicast routing tables.
6. Enables normal port operation.

Interpreting POST results

POST is a system check that is performed each time the switch is powered on, rebooted, or reset. During POST, the LEDs flash either amber or green. Any errors that occur during POST are listed in the error log.
Complete the following steps to determine whether POST completed successfully and whether any errors were detected.
1. Verify that the switch LEDs indicate that all components are healthy.
See Tab le 1 and Ta ble 2 for descriptions and interpretations of LED patterns. If one or more LEDs do not display a healthy state, verify that the LEDs on the switch are not set to “beacon” by entering the switchShow command to detect if beaconing is active.
2. Verify that the switch prompt displays on the terminal of a computer workstation connected to the switch.
Interpreting POST results
3
If there is no switch prompt when POST completes, press Enter. If the switch prompt still does not display, try opening a Telnet session or accessing the switch through another management tool. If this is not successful, the switch did not successfully complete POST. Contact your switch supplier for repair.
3. Review the switch system log for errors. Any errors detected during POST are written to the system log, accessible through the errShow command.
For information about all referenced commands, and on accessing the error log, refer to Fabric OS
Administrator’s Guide. For information about error messages, refer to the Fabric OS Message Reference Manual.

Brocade 5300 Maintenance

The Brocade 5300 is designed for high availability and low failure; it does not require any regular physical maintenance. It includes diagnostic tests and field-replaceable units, described in the following sections.

Installing an SFP

The Brocade 5300 only supports Brocade-branded SFPs. If you use an unqualified SFP, the switchShow command output shows the port in a Mod_Inv state. Fabric OS also logs the issue in the system error log.
Complete the following steps to install an SFP.
1. Making sure that the bail (wire handle) is in the unlocked position, place the SFP in the correctly oriented position on the port, as shown in Figure 5.
2. Slide the SFP into the port until you feel it click into place; then close the bail.
Brocade 5300 Hardware Reference Manual 23 53-1000858-04
Page 36
Brocade 5300 Maintenance
NOTE
NOTE
3
Each SFP has a 10-pad gold-plated PCB-edge connector on the bottom. The correct position to insert an SFP into the upper row of ports is with the gold edge down. The correct position to insert an SFP into the lower row of ports is with the gold edge up.
FIGURE 5 Installing an SFP in the upper row of port slot
Diagnostic tests
In addition to POST, Fabric OS includes diagnostic tests to help you troubleshoot the hardware and firmware. This includes tests of internal connections and circuitry, fixed media, and the transceivers and cables in use.
The tests are implemented by command, either through a Telnet session or through a console set up to the serial connection to the switch. Some tests require the ports to be connected by external cables, to allow diagnostics to verify the serializer/deserializer interface, transceiver, and cable. Some tests require loopback plugs.
Diagnostic tests run at link speeds of 1, 2, 4 and 8 Gbps depending on the speed of the link being tested.
Diagnostic tests might temporarily lock the transmit and receive speed of the links during diagnostic testing.
For information about specific diagnostic tests, see the Fabric OS Troubleshooting and Diagnostics Guide.
24 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 37
Brocade 5300 Maintenance
3

Field Replaceable Units (FRUs)

You can replace the power supplies and fan assemblies on site without the use of special tools. The power supplies and fan assemblies are keyed to ensure correct orientation during installation. Installation instructions are provided with all replacement units.
Power supplies
The two power supplies are hot-swappable. They are identical and fit into either power supply slot.
Fabric OS identifies the power supplies as follows (viewing the switch from the non-port side):
Power supply 1 on the right
Power supply 2 on the left
Use one of the following methods to determine if you need to replace a power supply.
Check the power supply status LED next to the On/Off switch (see “LED locations” on
page 18)
In Web Tools, click the Power Status icon.
Enter the psShow command at the prompt to display power supply status as shown below:
br5300:admin> psshow
Power Supply #1 is OK V10529, TQ2H0000030 ,60-0300031-01,X2, ,SP640 ,2X,TQ2H0000 Power Supply #2 is OK V10541, TQ2H0000189 ,60-0300031-01,X3, ,SP640-2P ,A ,TQ2H0000 br5300:admin>
For further information on replacing the power supplies, see the Mid-Size Switch Power Supply Replacement Procedure.
Fan assemblies
The three fan assemblies are hot-swappable. They are identical and fit into any fan assembly slot.
Each fan assembly contains two fans, identified by Fabric OS as follows (viewing the switch from the non-port side):
Fan assembly #1 on the right
Fan assembly #2 in the center
Fan assembly #3 on the left
Use one of the following methods to determine if you need to replace a fan assembly.
Check the fan status LED on the face of the fan assembly (see “LED locations” on
page 18)
In Web Tools, click the Fan Status icon.
Brocade 5300 Hardware Reference Manual 25 53-1000858-04
Page 38

Brocade 5300 Management

NOTE
3
Enter the fanShow command at the prompt:
br5300:admin> fanshow Fan 1 is Ok, speed is 4821 RPM Fan 2 is Ok, speed is 4821 RPM Fan 3 is Ok, speed is 4891 RPM br5300:admin>
For further information on replacing the fan assemblies, see the Brocade 5300 Fan Assembly Replacement Procedure.
Brocade 5300 Management
You can use the management functions built into the Brocade 5300 to monitor the fabric topology, port status, physical status, and other information to help you analyze switch performance and to accelerate system debugging.
The Brocade 5300 automatically performs power-on self-test (POST) each time it is turned on. Any errors are recorded in the system error log. For more information about POST, see “POST and boot
specifications” on page 22.
For information about upgrading the version of Fabric OS installed on your switch, see the Fabric
OS Administrator’s Guide.
You can manage the Brocade 5300 using any of the management options listed in Table 3.
TABLE 3 Management Options for the Brocade 5300 Switch
Management Tool Out-of-band Support In-band Support
Command line interface (CLI) Up to two admin sessions and four user sessions simultaneously.
For more information, refer to the Fabric OS Administrator’s Guide and the Fabric OS Command Reference Manual.
Brocade Web Tools For information, refer to the Web Tools Administrator’s Guide.
Standard SNMP applications For information, refer to the MIB Reference Manual.
Brocade Fabric Manager (option to purchase) For information, refer to the Fabric Manager Administrator’s Guide.
Management Server For information, refer to the Fabric OS Administrator’s Guide and
the Fabric OS Command Reference Manual.
EFCM (option to purchase) For information, refer to theEFCM documentation set.
Ethernet or serial connection
Ethernet or serial connection
Ethernet or serial connection
Ethernet or serial connection
Ethernet or serial connection
Ethernet or serial connection
IP over Fibre Channel
IP over Fibre Channel
IP over Fibre Channel
IP over Fibre Channel
Native in-band interface (over HBA only)
IP over Fibre Channel
To achieve in-band support for IP over Fibre Channel, the software must be run on both the HBA and the switch, and it must be supported by both the HBA and HBA driver.
26 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 39
Appendix

Brocade 5300 Specifications

In this appendix

Switch components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Weight and physical dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Facility requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Power supply specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Environmental requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
General specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Data transmission ranges. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Memory specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Fibre Channel port specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Serial port specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Regulatory compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
A

Switch components

The Brocade 5300 switch includes the following components:
Cabinet-mountable 2U chassis designed to be mounted in a 19-in. cabinet space, with
forced-air cooling that flows from the non-port side of the switch to the port side
80 Fibre Channel ports, compatible with short wavelength (SWL), long wavelength (LWL), and
extended long wavelength (ELWL) SFP transceivers
Two IEEE-compliant RJ-45 connector on the port side of the switch for use with a serial console
and 10/100 MB Ethernet
80 port Link LEDs, one switch power LED, one switch status LED, two Ethernet LEDs, two
power supply LEDs, and three fan LEDs
2 universal AC power supplies with AC switches and built-in fans
3 fan assemblies containing two fans each. The fans have two speeds, which are set
automatically and cannot be modified. They default to high speed upon boot, then switch to low speed as Fabric OS comes online, returning to high speed only as required.
Brocade 5300 Hardware Reference Manual 27 53-1000858-04
Page 40

Weight and physical dimensions

A
Weight and physical dimensions
Tab le 4 lists the weight and dimensions of the Brocade 5300.
TABLE 4 Physical specifications
Dimension Value
Height 2U or 8.6 cm (3.4 in.)
Depth 61 cm (24 in.)
Width 42.8 cm (16.8 in.)
Weight (with two power supplies, three fan assemblies, and zero SFPs installed)

Facility requirements

Tab le 5 provides the facilities requirements that must be met for the Brocade 5300.
TABLE 5 Facility Requirements
Type Requirements
15.6 kg (34.4 lb)
Electrical Primary AC input 100-240 VAC, 2.0A, 47-63 Hz; switch autosenses input voltage
Adequate supply circuit, line fusing, and wire size, as specified by the electrical rating
Circuit protected by a circuit breaker and grounded in accordance with local electrical
Refer to Table 6 on page 28 for complete power supply specifications.
Thermal
A minimum air flow of 79.8 cubic meters/hour (47 cubic ft/min.) available in the
Ambient air temperature not exceeding 40 C (104 F) while the switch is operating
Cabinet (when rack-mounted)
Two rack units (2U) in a 48.3 cm (19-inches) cabinet
All equipment in cabinet grounded through a reliable branch circuit connection
Additional weight of switch not to exceed the cabinet’s weight limits
Cabinet secured to ensure stability in case of unexpected movement

Power supply specifications

The power supplies are universal and capable of functioning worldwide without voltage jumpers or switches. They meet IEC 61000-4-5 surge voltage requirements and are autoranging in terms of accommodating input voltages and line frequencies. Each power supply has a built-in fan for cooling, pushing air towards the port side of the switch.
Tab le 6 lists the power supply specifications for the Brocade 5300.
on the switch nameplate
codes
immediate vicinity of the switch
TABLE 6 Power Supply Specifications
Specification Value
Inlet C13
Maximum output of one power supply 300 Watts
28 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 41
TABLE 6 Power Supply Specifications
Specification Value
Nominal system DC power consumption 260 Watts
Input voltage 85-264 VAC
Input line frequency 47-63HZ
BTU rating 1313 BTU/hr
Inrush current Maximum of 38A for period of 10-150mS
Input line protection Both AC lines are fused

Environmental requirements

Tab le 7 lists the acceptable environmental ranges for both operating and nonoperating (such as
during transportation or storage) conditions.
TABLE 7 Environmental requirements
Condition Acceptable during operation Acceptable During Non-Operation
Environmental requirements
A
Ambient Tem pera ture
Humidity 10% to 85% RH non-condensing, at
Altitude 0 to 3 km (10,000 feet) above sea level 0 to 12 km (40,000 feet) above sea level
Shock 20 G, 6 ms, half-sine wave 33 G, 11 ms, 3/eg Axis
Vibration 0.5 G, 5-500 Hz 2.0 G, 5-500 Hz
Air flow High speed 9000 RPM 102 CMH (60 CFM)

General specifications

Tab le 8 lists the general specifications for the Brocade 5300.
TABLE 8 General specifications
Specification Description
Configurable port types F_Port, FL_Port, E_Port, EX_Port, and M_Port
System architecture Nonblocking shared-memory switch
System processor Freescale MPC8548 x 1.3GHz
ANSI Fibre Channel protocol FC-PH (Fibre Channel Physical and Signalling Interface standard)
Modes of operation Fibre Channel Class 2 and Class 3
Fabric initialization Complies with FC-SW-3 Rev. 6.6
FC-IP (IP-over-Fibre Channel) Complies with FC-IP 2.3 of FCA profile
0º to 40º C 32º to 104º F
40º C (104º F), with maximum gradient of 10% per hour
Low speed 6000 RPM 74.8 CMH (44 CFM)
-25º to 70º C
-13º to 158º F
10% to 90% RH non-condensing, at 70º C (158º F)
None required.
Brocade 5300 Hardware Reference Manual 29 53-1000858-04
Page 42
General specifications
A
TABLE 8 General specifications
Specification Description
Aggregate switch I/O bandwidth 1280 Gbps if all 80 ports are running at 8 Gbps, full duplex
Port-to-port latency Less than 2100 nanoseconds with no contention (destination port is free)
Tab le 9 lists the electromagnetic compatibility (EMC) for the Brocade 5300.
TABLE 9 EMC specifications
Country Safety EMC
United States Bi_Nat UL/CSA 60950-1 1st Ed or
latest
Canada Bi_Nat UL/CSA 60950-1 1st Ed or
latest
Japan CISPR22 and JEIDA (Harmonics)
European Community EN60950-1 or latest EN55022 and EN55024
Australia/New Zealand EN55022 or CISPR22 or AS/NZS
Argentina IEC60950-1 or latest
Russian Federation IEC60950-1 or latest 51318.22-99 and 51318.24.99
Korea KN22 and KN24
China (PS only) GB4943-2001 and
GB9254-1998 or latest
Taiwan (PS only) CNS 14336(94) or latest CNS 13438(95) or latest
ANSI C63.4
ICES-003 Class A
CISPR22
GB17625.1-2003 or latest
30 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 43

Data transmission ranges

Tab le 10 provides the data transmission ranges for different cable types and port speeds.
TABLE 10 Data transmission ranges
Port Speed Cable Size
(microns)
Data transmission ranges
Short Wavelength (SWL) Long Wavelength (LWL) Extended Long
Wavelength (ELWL)
A
1 Gbps 50 500 m (1,640 ft) (OM2)
860 m (2,821 ft) (OM3)
62.5 300 m (984 ft) NA NA
9 NA 10 km (6.2 mi) 80 km (50 mi)
2 Gbps 50 300 m (984 ft) (OM2)
500 m (1,640 ft) (OM3)
62.5 150 m (492 ft) NA NA
9 NA 10 km (6.2 mi) 80 km (50 mi)
4 Gbps 50 150 m (492 ft) (OM2)
380 m (1,246 ft) (OM3)
62.5 70 m (230 ft) NA NA
9 NA 10 km (6.2 mi) NA
8 Gbps 50 50 m (164 ft) (OM2)
150 m (492 ft) (OM3)
62.5 21 m NA NA
9NA 10 km NA
NA NA
NA NA
NA NA
NA NA
Up to 500 km at 1G is supported when using long distance transport system such as DWDM.

Memory specifications

The Brocade 5300 has three types of memory devices:
TABLE 11 Brocade 5300 memory specifications
Type Size
Boot flash 4 MB
Compcat flash 1 GB
Main memory (DDR2 SDRAM) 1 GB

Fibre Channel port specifications

The Fibre Channel ports in the Brocade 5300 are compatible with SWL, LWL, and ELWL SFP transceivers. The strength of the signal is determined by the type of transceiver in use.
The ports meet all required safety standards. For more information about these standards, see
“Regulatory compliance” on page 32.
Brocade 5300 Hardware Reference Manual 31 53-1000858-04
Page 44

Serial port specifications

NOTE
A
The ports are capable of operating at 1, 2, 4, or 8 Gbps and are able to autonegotiate to the maximum link speed.
Serial port specifications
The serial port is located on the port side of the switch. The Brocade 5300 uses an RJ-45
connector for the serial port. An RJ-45 to DB9 adaptor cable is also provided with the switch.
To protect the serial port from damage, keep the cover on the port when not in use.
The serial port can be used to connect to a workstation to configure the switch IP address before connecting the switch to a fabric or IP network. The serial port’s parameters are fixed at 9600 baud, 8 data bits, and no parity, with flow control set to None.
Tab le 12 lists the serial cable pinouts.
TABLE 12 Serial cable pinouts
PIN Signal Description
1Not supported NA
2Not supported NA
3UART1_TXD Transmit data
4GND Logic ground
5GND Logic ground
6UART1_RXD Receive data
7Not supported NA
8Not supported NA

Regulatory compliance

This section describes the regulatory compliance requirements for the Brocade 5300. It contains:
“FCC warning (US only),” next
“KCC statement (Republic of Korea)” on page 33
“VCCI statement Japan” on page 33
“Power cords (Japan Denan)” on page 33
“China statement” on page 34
“BSMI statement (Taiwan)” on page 35
“CE statement” on page 35
“Canadian requirements” on page 35
“Laser compliance” on page 35
“RTC battery” on page 35
“Electrical safety” on page 36
“Regulatory certifications” on page 36
32 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 45
Regulatory compliance
A鞾韥韥(꽺ꓩ끞 ꗞꭖ뭪겕韥韥): 넩 韥韥鱉 꽺ꓩ끞(A鞾)냱ꈑ 놹녅볁놶뼞麦ꈒ냹 뼑 韥韥넩꿙鱽 볅ꎙ녅
鿅鱉 ꩡ끞녅鱉넩 뇅냹 늱넍뼍겑韥 ꗉꄱꐥ, 閵뇊뀭넍 덵꾢꾅꫑ ꩡ끞뼍鱉 阸냹 ꑞ놶냱ꈑ 뼞鱽鲙.
A

FCC warning (US only)

This equipment has been tested and complies with the limits for a Class A computing device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, might cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.

KCC statement (Republic of Korea)

Class A device (Broadcasting Communication Device for Office Use): This device obtained EMC registration for office use (Class A), and may be used in places other than home. Sellers and/or users need to take note of this.

VCCI statement Japan

This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance might arise. When such trouble occurs, the user might be required to take corrective actions.

Power cords (Japan Denan)

Brocade 5300 Hardware Reference Manual 33 53-1000858-04
Page 46
Regulatory compliance
汉文  “仅适用于非热带气候条件下安全使用。” 
藏文 
蒙古 文
壮文 
Dan hab yungh youq gij dienheiq diuzgen mbouj dwg diegndat haenx ancienz sawjyungh.
安全 说明 和标 记 
维文 
汉文  仅适用于海拔2000m以下地区安全使用。
藏文 
蒙古 文 
壮文 
Dan hab yungh youq gij digih haijbaz 2000m doxroengz haenx ancienz sawjyungh.
安全 说明 和标
记 
维文 
在维修的时候一定要断开所有电源 (English translation“disconnect all power sources before service”)
For non tropical use:
For altitude 2000 meter and below:
China-CCC Warning statements
English translation of above statement
This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures.
Warning for Class A:
A

China statement

34 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 47
Regulatory compliance
ATTENTION
ATTENTION
A

BSMI statement (Taiwan)

Warning:
This is Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

CE statement

This is a Class A product. In a domestic environment, this product might cause radio interference, and the user might be required to take corrective measures
The standards compliance label on the Brocade 5300 contains the CE mark which indicates that this system conforms to the provisions of the following European Council directives, laws, and standards:
Electromagnetic Compatibility (EMC) Directive 2004/108/EEC
Low Voltage Directive (LVD) 2006/95/EC
EN50082-2/EN55024:1998 (European Immunity Requirements)
- EN61000-3-2/JEIDA (European and Japanese Harmonics Spec)
- EN61000-3-3

Canadian requirements

This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations, ICES-003 Class A.

Laser compliance

This equipment contains Class 1 laser products and complies with FDA Radiation Performance Standards, 21 CFR Subchapter I and the international laser safety standard IEC 825-2.
Use only optical transceivers that are qualified by Brocade Communications Systems, Inc. and comply with the FDA Class 1 radiation performance requirements defined in 21 CFR Subchapter I, and with IEC 825-2. Optical products that do not comply with these standards might emit light that is hazardous to the eyes.

RTC battery

Brocade 5300 Hardware Reference Manual 35 53-1000858-04
Page 48
Regulatory compliance
ATTENTION
ATTENTION
ATTENTION
ATTENTION
A
Do not attempt to replace the real-time clock (RTC) battery. There is danger of explosion if the battery is incorrectly replaced or disposed of. Contact your switch supplier if the real-time clock begins to lose time.

Electrical safety

This switch might have more than one power cord. To reduce the risk of electric shock, disconnect both power cords before servicing.
Connect the power cord only to a grounded outlet.
This product is designed for an IT power system with phase-to-phase voltage of 230V. After operation of the protective device, the equipment is still under voltage if it is connected to an IT power system.

Regulatory certifications

Tab le 13 lists the EMC compatibility for the Brocade 5300.
TABLE 13 EMC (electromagnetic compatibility)
Country Safety EMC
United States Bi_Nat UL/CSA 60950-1 1st Ed or
latest
Canada Bi_Nat UL/CSA 60950-1 1st Ed or
latest
Japan CISPR22 and JEIDA (Harmonics)
European Community EN60950-1 or latest EN55022 and EN55024
Australia/New Zealand EN55022 or CISPR22 or AS/NZS
Argentina IEC60950-1 or latest
Russian Federation IEC60950-1 or latest 51318.22-99 and 51318.24.99
Korea KN22 and KN24
China (PS only) GB4943-2001 and
GB9254-1998 or latest
Taiwan (PS only) CNS 14336(94) or latest CNS 13438(95) or latest
ANSI C63.4
ICES-003 Class A
CISPR22
GB17625.1-2003 or latest
36 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 49

Environmental regulation compliance

⦃ֱՓ⫼ᳳ䰤 (EPUP) ܡ䋷ໄᯢ˖
EPUP 󰵼ᖫϡӮߎ⦄೼ѻક FRU ⱘᬍ㺙ѻકЁˈгϡӮᇍ Brocade
᠔ᦤկⱘⳌ݇ѻકֱׂᴵℒ˄䆹ֱׂᴵℒ೼ Brocade ঞ݊ᅶ᠋䯈䖒៤ⱘ䗖⫼ড়ৠЁ߫ߎ˅䖯㸠๲㸹DŽᇍѢℸ CD Ϟࣙ৿ⱘⳌֵ݇ᙃˈབ䗖䫔ᗻǃ䩜ᇍ⡍ᅮ⫼䗨ⱘ䗖⫼ᗻ䴲։ᴗᗻⱘᱫ⼎ֱ䆕ˈBr
ocade ೼ℸ䚥䞡ໄᯢᴀ݀ৌᇍѢϢϞ䗄ֵᙃⳌ݇ⱘ᠔᳝݊Ҫֱ䆕䰜䗄ὖϡ䋳䋷DŽ EPUP ؛䆒೼Āѻક᪡԰᠟ݠāЁ⊼ᯢⱘᐌ㾘ᴵӊϟՓ⫼䆹ѻકDŽ
This section describes the “China RoHS” environmental regulatory compliance requirements for the Brocade 5300 switch.

China RoHS

The contents included in this section are per the requirements of the People's Republic of China­Management Methods for Controlling Pollution by Electronic Information products.
䙉ᅜ⦃๗⊩㾘 Ё೑ RoHS ᴀ㡖Ёࣙ৿ⱘݙᆍ䛑䙉ᅜњЁҎ⇥݅೑lj⬉ᄤֵᙃѻક∵ᶧ᥻ࠊㅵ⧚ࡲ⊩NJⱘ 㽕∖DŽ
Environmental protection use period (EPUP) disclaimer
In no event do the EPUP logos shown on the product and FRUs alter or expand that warranty that Brocade provides with respect to its products as set forth in the applicable contract between Brocade and its customer. Brocade hereby disclaims all other warranties and representations with respect to the information contained on this CD including the implied warranties of merchantability, fitness for a particular purposes and non-infringement.
Environmental regulation compliance
A
The EPUP assumes that the product will be used under normal conditions in accordance with the operating manual of the product.
Brocade 5300 Hardware Reference Manual 37 53-1000858-04
Page 50
Environmental regulation compliance
A
TS/HS dual language sheet
In accordance with China's Management Measures on the Control of Pollution caused by Electronic Information products (Decree No. 39 by the Ministry of Information Industry), the following information is provided regarding the names and concentration level of Hazardous substances (HS) which may be contained in this product.
TABLE 14 China ROHS hazardous substances/toxic substances (HS/TS) concentration chart
Name of the Component
Hazardous/Toxic Substance/Elements
Lead (PB) Mercury
(Hg)
Cadium (CD)
Hexavalent Chromium (CR6+)
Polybrominated Biphenyl (PBB)
Polybrominated Diphenyl Ether (PBDE)
Fibre Channel Switch
Fan, Blower assemblies
PCBA cards X O O O O O
Power Supply kit X O O O O O
SFPs (optical
XOOO O O
XOOO O O
XOOO O O cable connectors)
Sheet Metal X O O O O O
Chassis Assembly
Mechanical brackets and Slides
Slot Filler X O O O O O
Cable management tray
Cable Comb O O O O O O
Cables and power cords
Replacement Doors
Software/ Documentation CDs
XOOO O O
XOOO O O
XOOO O O
OO OO O O
XOOO O O
OO OO O O
X indicates that the concentration of such hazardous/toxic substance in all the units of homogeneous material of such component is higher than the SJ/T11363-2006 Requirements for Concentration Limits.
38 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 51
Environmental regulation compliance
O indicates that no such substances are used or that the concentration is within the aforementioned limits.
A
Brocade 5300 Hardware Reference Manual 39 53-1000858-04
Page 52
Environmental regulation compliance
A
40 Brocade 5300 Hardware Reference Manual
53-1000858-04
Page 53

Index

A
access
NTP
, 14
B
boot, 22 Brocade Advanced Web Tools Brocade Fabric Manager BSMI statement (Chinese) BSMI statement (Taiwan)
, 26
, 35
, 35
C
Canadian requirements, 35 CE statement China RoHS Command line interface (CLI) configuring
date and time NTP
configuring the Brocade 5300
, 35
, 37
, 12
, 14
D
, 26
, 26
, 10
F
Fabric Manager, 26 facility requirements FCC warning (US only) Fibre Channel Association Fibre Channel port specifications field replaceable units (FRUs) front panel
LEDs
, 17
FRUs
, 25
, 28
, 33
, x
, 31
, 25
G
general specifications, 29
I
installation and safety considerations, 7 installing a Brocade 5300 into an EIA cabinet installing a stand-alone Brocade 5300 installing an SFP interpreting LED activity interpreting post results items included with the Brocade 5300 items required for installation
, 23
, 17 , 23
, 9
, 9
, 7
, 10
data transmission ranges, 31 date
, 13
date and time diagnostic tests
, 12
, 24
K
KCC statement, 33 KCC statement (Republic of Korea)
, 33
E
electrical safety, 36 environmental requirements event
date and time
Brocade 5300 Hardware Reference Manual 41 53-1000858-04
, 12
, 29
L
laser compliance, 35
Page 54
LEDs
interpreting on front panel
LEDs on the port side of the switch local clock LOCL
, 14
logging
timestamp
, 17
, 17
, 14
, 12
M
maintaining, 23 Management Server managing memory specifications MIC statement (Republic of Korea) monitoring
, 26
through LED activity
, 26
, 31
, 17
, 17
, 33
RTC battery
, 35
S
serial port specifications, 32 setting
time zone setting the date and time setting the default account passwords
setting the IP address setting the switch date and time Setting time zones settings
date and time SNMP switch components
, 14
, 12
, 11
, 12
, 14
, 12
, 26
, 27
T
, 12
N
nonport side view, 3 NTP
access
, 14
O
overview, 1
P
POD license, 4 port side view ports on demand license post
, 22
post and boot specifications power supply specifications provide power to the switch
, 2
, 4
, 22 , 28 , 10
time, 12 time and date Time zones time zones tsclockserver tsTimeZone
, 12
, 12
, 12
, 14
, 14
V
VCCI statement, 33
W
weight and physical dimensions, 28
R
recommendations for cable management, 8 regulatory certifications regulatory compliance
42 Brocade 5300 Hardware Reference Manual
, 36
, 32
53-1000858-04