Bradford White LE120L3-3, LE130L3-3, LE140L3-3, LE150L3-3 User Manual

0 (0)

Residential & Light Duty

Commercial Electric Water Heaters

SERVICE MANUAL

Troubleshooting Guide and Instructions for Service

(To be performed ONLY by qualified service providers)

Models Covered

by This Manual:

Residential:

RE1 & RE3 Upright Models.

RE1 & RE2 Lowboy Models.

RE1 Utility Models.

RE1 Wall Hung Models.

Light Duty:

LE Upright Models.

LE Utility Models.

LE Lowboy.

LE Wall Hung.

Manual 238-51544-00A REV 08/18

Save this manual for future reference

Residential and Light Duty

Commercial Electric Water Heaters

 

Page

 

Service Procedure

Introduction……………………………………………………………………

2

- - -

Tools……………………………………………………………………………

2

- - -

General Information…………………………………………………………..

3

- - -

Sequence of Operation………………………………………………………

6

- - -

Single Element Operation……………………………………..........

6

- - -

Double Element Non-Simultaneous Single Phase……………….

7

- - -

Double Element Simultaneous Single Phase 4 wire Service……

8

- - -

Double Element Non-Simultaneous 3 Phase………....................

9

- - -

Double Element Simultaneous 3 Phase…………………………..

10

- - -

Double Element Non-Simultaneous Single Phase Off Peak …..

11

- - -

Troubleshooting……………………………………………………………...

12

- - -

Line Voltage and High Limit ECO Testing…………………………………

14

 

RE-I

Heating Element Testing……………......................................................

15

 

RE-II

Residential Thermostat Testing ……......................................................

16

 

RE-III

Single Element …………………………….....................................

16

 

 

Double Element, 4 wire, Simultaneous, Single Phase …………..

16

 

 

Double Element, Non-Simultaneous, Single Phase ……….........

17

 

 

Double Element, Non-Simultaneous, 3 Phase …………………...

19

 

 

Double Element, Simultaneous, 3 Phase …………………………

21

 

 

Double Element, Non-Simultaneous, Single Phase, Off Peak …

23

 

 

Light Duty Commercial Thermostat Testing ….......................................

25

 

RE IV

Double Element, Non-Simultaneous, Single Phase……………...

25

 

 

Double Element, Simultaneous, Single Phase …………………...

27

 

 

Double Element, Non-Simultaneous, 3 Phase ……………………

29

 

 

Double Element, Simultaneous, 3 Phase ………………………….

31

 

 

Thermostat Removal and Replacement ……………………………………

33

 

RE-V

Heating Element Removal and Replacement ……………………………..

34

 

RE-VI

DipTube and Anode Inspection and Replacement ……………………….

35

 

RE-VII

Generic Parts List …………………………………………………………….

36

- - -

This service manual is designed to aid service and maintenance professionals on the function, proper diagnosis and repair of Bradford White residential electric and light duty commercial electric water heaters.

The text and illustrations in this manual provide step by step instructions to facilitate proper operation and troubleshooting procedures. Contact the Bradford White Technical Support Group immediately if diagnosis can not be made using the methods described in this service manual.

- Multi Meter

- Phillips Head Screw Driver

- 1-½ Deep Well Socket

- Thermometer

- ¼" Nut Driver

- Drain Hose

- Various Hand Tools: Pipe Wrench, Channel Locks, Pliers (common & needle nose), Wire cutters, Wire Strippers, Flash Light.

Page 2

2

 

 

 

 

 

 

 

 

GENERAL INFORMATION

 

 

 

 

 

 

 

 

Commonly Used Formulas

 

 

 

 

 

 

Amps =

Watts

(for single phase units) Example: 4500W/240V = 18.75A

 

 

 

 

 

 

Volts

 

 

 

 

 

Amps =

Watts

 

(for balanced 3 phase units) Example: 4500W/240V x 1.732 = 10.82A

 

Volts x 1.732

 

 

 

 

 

Watts = Amps x Volts

Example: 18.75A x 240V = 4500W

 

 

 

Volts2

2

 

Ohms =

 

 

 

 

 

Example: (240V) / 4500W = 12.8 Ohms

 

Watts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

WHITE

GREEN

BLACK

RED

GREEN

Grounded

Ungrounded

(Neutral)

Grounding

Ungrounded

Ungrounded

Grounding

 

120

 

 

 

 

 

 

0

 

 

 

 

 

240

 

 

 

 

 

 

120

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120

 

 

 

 

120

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Neutral

A

B

C

 

120

 

 

120

 

 

 

120

 

 

208

 

208

 

208

RED BLACK RED

Neutral

A

 

B

C

Neutral

A

 

B

C

 

 

120

 

 

 

 

277

 

 

120

 

 

 

277

 

 

 

120

 

 

240

 

277

 

 

480

 

 

 

240

240

 

 

 

480

480

 

 

RED

BLACK

RED

 

RED

BLACK

RED

Page 3

3

GENERAL INFORMATION

Wattage Limitations at Various Voltages

Residential Electric Upright RE2 & RE3 Series (Non-Simultaneous Operation)

Residential High Efficiency Upright RE2 Series (Non-Simultaneous Operation)

Residential Electric Lowboy RE2 Series (Non-Simultaneous Operation)

Maximum

Element

Voltage

Wattage

Upper/Lower

 

3,000

3,000/3,000

120

 

 

 

6,000

6,000/6,000

208, 240

 

 

 

6,000

6,000/6,000

277, 480

 

 

 

Residential Electric Upright RE2 & RE3 Series (Simultaneous Operation)

Residential High Efficiency Upright RE2 Series (Simultaneous Operation)

Residential Electric Lowboy RE2 Series (Simultaneous Operation)

Light Duty Commercial Electric LE Series (Non-Simultaneous Operation)

Light Duty Commercial Electric LE Series (Simultaneous Operation)

Maximum

Element

Voltage

Wattage

Upper/Lower

 

3,000

1,500/1,500

120

 

 

 

10,000

5,000/5,000

208

 

 

 

11,000

5,500/5,500

240

 

 

 

12,000

6,000/6,000

277, 480

 

 

 

Residential Electric Utility Series (Single Element Operation)

Light Duty Utility Series (Single Element Operation)

Maximum

Single

Voltage

Wattage

Element

 

3,000

3,000

120

 

 

 

6,000

6,000

208, 240

 

 

 

6,000

6,000

277

 

 

 

6,000

6,000

480

 

 

 

Page 4

4

GENERAL INFORMATION

Surface Mounted Thermostats

Surface mounted thermostats are mounted into a bracket which holds the thermostat against the side of the tank. Surface mounted thermostats respond to tank surface temperatures to sense a call for heat, set point temperature settings and high limit (ECO) activation. It is important that the entire back surface of the thermostat is in full contact or flush with the tank. Improperly mounted thermostat will lead to improper water heater operation.

Manual

 

ECO (high limit)

 

Reset button

 

Temperature

Temperature

control Dial

control Dial

Surface Mount

Surface Mount

Surface Mount

Combination Thermostat/

Combination Thermostat/

Thermostat

ECO (high limit)

ECO (high limit)

59T Series

59T/66T Series

59T/66T Series

 

Direct Immersion “Screw-in” Type Heating Element

1-½ Hex

 

Terminal Block

Screw-in Flange

 

 

 

Zinc Plated Copper or

Incoloy Sheath

Terminal Block

 

Element Rating Ink Stamped

Screw

 

on side of Terminal Block.

 

 

Page 5

5

SEQUENCE OF OPERATION

Residential and light duty commercial electric water heaters are designed to operate using several different operating modes. The common modes and sequence of operation are as follows:

1.Single Element Operation.

2.Double Element Non-Simultaneous Operation (single phase).

3.Double Element Non-Simultaneous Operation (3 phase).

4.Double Element Simultaneous Operation (single phase).

5.Double Element Simultaneous Operation (3 phase).

Sequence of Operation- Single Element Operation.

1Line voltage is applied across terminals L1 & L3 of the thermostat. ECO is closed, so there is voltage at terminal L4 and to one side of the element.

2Tank is cold therefore thermostat

is closed at terminal T2 (calling for heat). This completes the circuit and allows current to flow through the element.

1

ECO

Closed

2

Thermostat closed at terminal T2

3 When the thermostat is satisfied, it opens at

3

terminal T2 interrupting current flow through the

 

element. System is now in stand-by mode, waiting

 

for the next call for heat.

 

 

Thermostat opens

 

at terminal T2

Page 6

6

SEQUENCE OF OPERATION

Non-Simultaneous and Simultaneous Operation

Double element electric water heaters are designed to operate in either Non-Simultaneous or Simultaneous mode.

Non-Simultaneous Mode: Allows only one heating element to operate at a time. For example, when the tank is cold, the upper element is energized first, heating the top of the tank. Only when the upper thermostat is satisfied, the upper element is de-energized and power is directed to the lower thermostat, energizing the lower element and heating the bottom portion of the tank until the lower thermostat is satisfied. As hot water is drawn off the tank, it is replaced with cold water delivered through the diptube to the bottom of the tank. When the tank cools at the lower thermostat level, the lower thermostat will call for heat, energizing the lower element. If enough hot water is drawn from the tank, the top portion of the tank cools and the upper thermostat will call for heat, de-energizing the lower element and allowing only the top element to energize until the upper thermostat is satisfied.

Simultaneous mode: allows both heating elements to operate at the same time. That is, if either thermostat (upper or lower) is calling for heat, the corresponding heating element is energized independent of the other.

Sequence of Operation- Double Element, Non-Simultaneous Operation, Single Phase.

1 Line voltage is applied across terminals

 

 

L1 & L3 of the upper thermostat. ECO is

 

 

closed, so there is voltage at terminal L4

 

 

and to one side of the upper and lower

 

 

elements.

1

2

 

2

Tank is cold. Therefore, the thermostats

 

 

 

 

are closed at terminals T2 & 2 (calling for heat).

 

 

 

 

The circuit is complete through the upper

 

ECO

Thermostat closed

 

thermostat only, allowing current to flow through

 

Closed

at terminal T2

 

upper element.

 

 

 

3

When the upper thermostat is satisfied, it opens at

Upper

 

Upper

 

terminal T2, interrupting current flow through the

T’stat

 

T’stat

 

 

 

 

 

upper element. Terminal T4 closes, allowing voltage

 

 

 

 

to pass to terminal 1 of the lower thermostat. This

Upper

 

Upper

 

completes the circuit through the lower thermostat

Element

 

Element

 

and allows current flow through the lower element.

 

 

at terminal 2

 

 

 

 

Thermostat closed

4

When the lower thermostat is satisfied, it opens at

T’stat

 

T’stat

 

terminal 2, interrupting current flow through lower

 

 

 

Lower

 

Lower

 

element. The system is now in stand-by mode

 

 

 

 

waiting for the next call for heat.

Lower

 

 

 

 

 

Lower

 

 

Element

 

 

 

 

Element

 

 

 

 

5

The lower thermostat/element

 

 

combination will generally

 

 

cycle on and off more often

3

 

than the upper. In some cases,

 

such as a cold tank or in high

 

 

demand periods, the upper

 

 

thermostat will call for heat

 

 

(opening at terminal

Thermostat

closed

 

T4 and closing at

at terminal T4

 

 

 

terminal T2) prior to the lower

 

 

thermostat being satisfied. This

Upper

 

will interrupt current flow

 

T’stat

 

 

 

 

through the lower thermostat

 

 

and element and allow current

Upper

 

to flow through the upper

 

Element

 

element only. When the upper

 

 

thermostat is satisfied, it

 

 

 

resumes operation as

 

T’stat

 

described in sequence #3

 

 

 

Lower

 

above.

 

 

 

 

 

Lower

 

 

 

Element

4

5

Thermostat open between terminals 1 and 2

Upper

T’stat

Upper

Element

Lower

T’stat

Thermostat closed

at terminal T2

Upper

T’stat

Upper

Element

Thermostat closed

between terminals

1 and 2

Lower

T’stat

Lower

Lower

Element

Element

Page 7

7

SEQUENCE OF OPERATION

A 4 wire, double element heater wired for simultaneous operation is essentially two single element systems operating independently. The heaters are wired internally with two independent circuits, one circuit for each thermostat/element combination. When installed using a two wire service, the blue and red (or white) wires will be connected together, likewise black and yellow wires will be connected together.

Sequence of Operation- Double Element, Simultaneous Operation, Single Phase, 4 wire service installation.

1Line voltage from circuit one is applied across terminals L1 & L3 of the lower thermostat. Likewise, line voltage from circuit two is applied across terminals L1 & L3 of the upper thermostat. ECO in both upper and lower thermostat is closed, so there is voltage at terminal L4 of each thermostat and to one side of the upper and lower elements.

2Tank is cold therefore both thermostats are closed at terminal T2 (calling for heat). This completes the circuit through the thermostats and allows current to flow through the elements.

1

Circuit two

 

Circuit one

2

Circuit two

 

Circuit one

ECO

Thermostat closed

Closed

at terminal T2

 

ECO

Closed

Thermostat closed at terminal T2

3When either thermostat is satisfied, it will open at terminal T2, interrupting current flow through the corresponding element. As both thermostats satisfy, the system will be in stand-by mode waiting for the next call for heat. Thermostats will operate independent of each other.

3

Circuit two

 

Circuit one

Thermostat open at terminal T2

Thermostat open at terminal T2

Page 8

8

Bradford White LE120L3-3, LE130L3-3, LE140L3-3, LE150L3-3 User Manual

SEQUENCE OF OPERATION

Sequence of Operation- Double Element, Non-Simultaneous Operation, 3 Phase.

1Line voltage is applied across terminals L1 & L3 of upper thermostat. Likewise, Line voltage is applied to terminal L3 of lower thermostat. ECO in both upper & lower thermostat is closed, so there is voltage at terminal L4 of both thermostats and to one side of both upper & lower elements.

2Tank is cold therefore both thermostats are closed at terminal T2 (calling for heat). The circuit is complete through the upper thermostat only allowing current to flow through the upper element.

3When the upper thermostat is satisfied, it opens at terminal T2 interrupting current flow through upper element, and closes at terminal T4 allowing voltage to pass to terminal L1 of lower thermostat. This completes the circuit through the lower thermostat allowing current flow through lower element.

4When the lower thermostat is satisfied, it opens at terminal T2 interrupting the current flow through the lower element. The system is now in stand-by mode waiting for the next call for heat.

5The lower thermostat/element combination will generally cycle on and off more often than the upper. In some cases, such as a cold tank or in high demand periods, the upper thermostat will call for heat (opening at terminal T4 and closing at terminal T2) prior to the lower thermostat being satisfied. This will interrupt current flow through the lower thermostat and element and allow current to flow through the upper element only. When the upper thermostat is satisfied, it resumes operation as described in sequence #3 above.

1

2

ECO

Thermostat closed

Closed

 

at terminal T2

ECO

Closed Thermostat closed at terminal T2

3

4

Thermostat closed

Thermostat closed

at terminal T4

at terminal T4

Thermostat closed

 

at terminal T2

Thermostat open

 

at terminal T2

5

Thermostat closed at terminal T2

Thermostat closed at terminal T2

Page 9

9

SEQUENCE OF OPERATION

Sequence of Operation- Double Element, Simultaneous Operation, 3 Phase.

1Line voltage is applied across terminals L1 & L3 of upper thermostat. Line voltage also extends to terminal L1 of lower thermostat. Also, line voltage is applied to terminal L3 of lower thermostat. ECO in both upper & lower thermostat is closed, so there is voltage at terminal L4 of both thermostats and to one side of both upper & lower elements.

2Tank is cold therefore both thermostats are closed at terminal T2 (calling for heat). This completes the circuit through the thermostats and allows current to flow through the elements.

3When either thermostat is satisfied, it will open at terminal T2, interrupting current flow through the corresponding element. As both thermostats satisfy, the system will be in stand-by mode waiting for the next call for heat. Thermostats will operate independent of the other.

1

2

ECO

 

Closed

Thermostat closed

 

at terminal T2

ECO

Closed Thermostat closed at terminal T2

3

Thermostat open at terminal T2

Thermostat open at terminal T2

Page 10

10

SEQUENCE OF OPERATION

Some electric utility companies will offer discounts for using electricity during “Off Peak” Times of the day. The system allows the use of an “Off Peak” meter, which interrupts power to the lower element during high power demand periods.

Sequence of Operation- Double Element, Non-Simultaneous Operation, Single Phase, Off Peak.

1Line voltage is applied across terminals

L1 & L3 of the upper thermostat. Line voltage from off peak meter is supplied to terminal L1 of lower thermostat. ECO in the upper thermostat is closed, so there is voltage at terminal L4 of upper thermostat and to one side of the upper element.

Tank is cold therefore both thermostats

2are closed at terminal T2 (calling for heat). The circuit is complete through the upper thermostat only, allowing current to flow through upper element.

3When upper thermostat is satisfied, it opens at terminal T2 interrupting current flow through upper element, and closes at terminal T4 allowing voltage to pass to one side of the lower element. This completes the circuit through the lower thermostat and off peak meter allowing current flow through lower element.

4When the lower thermostat is satisfied, it opens at terminal T2 interrupting current flow through lower element. The system is now in stand-by mode waiting for the next call for heat

5During peak power demand periods as determined by the local utility, the off peak meter will interrupt power to terminal L1 of lower thermostat. Only the top thermostat/element combination is allowed to operate during this period.

From

Off Peak

Meter

1

 

2

 

ECO

Thermostat closed

 

Closed

 

at terminal T2

 

 

Thermostat closed at terminal T2

From

3

4

5

Off Peak

 

 

Off Peak

Meter

 

 

Power interrupted

Thermostat closed

 

 

Thermostat closed

at terminal T4

 

 

at terminal T2

Thermostat closed

Thermostat open

at terminal T2

at terminal T2

Page 11

11

TROUBLESHOOTING

Most common cause for improper electric water heater operation can be linked to heating element failure.

When troubleshooting an electric water heater with the incidence of “No Hot Water” or “Insufficient Amount of Hot Water,” It’s always a good idea to check the heating elements first by following the procedure on page 15.

Common Heating Element Failures:

1.Dry Firing. Element may be partially submerged in water or most likely, completely exposed with no water in tank. In some cases, sediment or lime build up around an element can eventually cause an air pocket, and within seconds, result in a dry fired element. At this point the element becomes inoperative. When element replacement is required, be sure the tank is full of water prior to energizing the water heater.

2.Grounded Element. An element with a short circuit to ground will in most cases cause the circuit breaker in the service panel to open or shut off. In some cases, there may not be enough current draw for the circuit breaker to open. This will allow the heating element to be in continuous operation resulting in over heated water, limited only by the ECO or Energy Cut Out. Repeated actuation of the ECO is

usually the result of a grounded element.

3.Sediment build up. Slow hot water recovery can usually be traced back to sediment or lime build up around heating element. Sediment build up can also over time cause a dry fired element.

Figure 1, below shows a common “Screw-In” type heating element identifying certain features commonly referred to throughout this manual.

1-½ Hex

 

Terminal Block

Screw-in Flange

 

 

 

Zinc Plated Copper or

Incoloy Sheath

 

 

 

 

0642

4500W 240V

RC02404524

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Terminal Block

 

Element Rating Ink Stamped

Screw

 

on side of Terminal Block.

 

 

Figure 1

Typical Direct Immersion “Screw-In”

Type Heating Element

Page 12

12