Bosch D9210C Specsheet

Intrusion Alarm Systems | D9210C Access Control Interface Module
D9210C Access Control Interface Module
www.boschsecurity.com
u Direct interface to 26‑bit Wiegand card readers
u Onboard buzzer output
u Supervised onboard point
The D9210C Access Control Interface Module is a fully supervised, addressable SDI bus device that allows access control integration for Bosch G Series Control Panels. This highly reliable module offers 14 programmable levels of access authority. Authority for access is controlled by the level of the user, the time of day, the state of the door and the armed state of the area. Each of the authority restrictions can be controlled through automatic and manual functions. Users can be added to the system with local programming using RPS (Remote Programming Software), D5200, or with credentials using the Add User function through keypads.
Functions
Reader Input
• Standard 5-wire Weigand interface.
• +5 VDC or +12 VDC supplied to power readers.
• Open collector output for reader LED.
Unsupervised Inputs
• Tamper – supports normally open devices.
• REX – supports normally open devices. Request to Exit on short.
• RTE – supports normally open devices. Request to Enter on short.
Supervised Input
• 1000Ω End of line resistor.
• Use for door contact.
can have a shunt only option
u Four door states: Locked, Unlocked, Secured, Fire
Unlock
Door States
Four-door states are controlled through the keypad, RPS (Remote Programming Software), scheduled events (Skeds) and automatic programmable functions in the D9210C parameters:
• Locked: Lock Relay de-activated thru valid credential or RTE (Request to Exit) input.
• Unlocked: allows the door to be opened for free access. Lock Relay is activated.
• Secured: does not allow access unless a Fire Unlock occurs. Valid credential or RTE will not activate relay.
• Fire Unlock: allows free access no matter what the previous door state or armed state is. This is a programmable option that can be used to allow free access into or out off the building upon a fire alarm.
Two automatic functions link the door state to the arming state of the area:
• Auto Door: When the area is disarmed, the door state is switched to “Unlocked.”
• Disarm on Open: with this function as "Yes," a user with valid access rights will activate the strike and disarm the system after the door is opened. With this function as "No," the area will disarm upon the strike activation.
Indicators
• Heartbeat LED: Blue LED blinks on and off when system is operational. A steady On or Off LED indicates a system error.
2 | D9210C Access Control Interface Module
• Reader LED: Rapidly blinking LED indicates the Card data is being received. When the LED is off, no card data is being received.
Certifications and approvals
USA UL D9210C Series: ALVY: (UL294):
Access Control System Units AMCX: Central Station Alarm Units (UL1610), AOTX: Local Alarm Units (UL609), APAW: Police Station Alarm Units (UL365), APOU: Propriety Alarm Units (UL1076), NBSX: (UL1023): Household Burglar Alarm System Units, UOTU: (UL985): Control Units and Accessories – Household System Type, UOXX: Control Unit Accessories, System (UL864)
Region Certification
USA CSFM 7167-1615:0243 7167 -- CONTROL
UNIT (HOUSEHOLD)
CSFM 7165-1615:0242 7165 -- FIRE ALARM
CONTROL UNIT (COMMERCIAL)
Installation/configuration notes
The D9210C Access Control Interface Module is individually programmed through the control panel it is connected to.
Compatibility Information
Category Commercial Code Description
Readers and ARD-AYH12 EM Prox Wall Mount
Accessories ARD-AYJ12 EM Prox Mullion
ARD-AYK12 EM Prox Mini Mullion
ARD-AYQ12 EM Prox Wall Mount Vandal
Resistant
ARD-AYCE65B EM Prox or PIN Mullion
ARD-R10 HID iClass Mini Mullion
ARD-R40 HID iClass Wall Mount
D8223 HID Prox Wall Mount
D8224 HID Prox Mullion
D8224‑SP HID Prox Switch Plate Mount
D8225 HID Prox Mini Mullion
D8229 PIN Reader
Credentials ACA-ATR13 EM Tokens
ACD-ATR11ISO EM Cards
ACD-ATR14CS EM Clamshell Cards
ACD-IC2K26-50 iClass Cards
ACT-IC2K26-10 iClass Tokens
D8236‑10 HID Prox Cards
D8236KF‑10 HID Prox Tokens
Systems D9412GV4 Control Panel
D7412GV4 Control Panel
D9412GV3 Control Panel
D7412GV3 Control Panel
D9412GV2 Control Panel
D7412GV2 Control Panel
D9412G Control Panel
D7412G Control Panel
Parts included
Quantity Component
1 D9210C
1 1 kΩ ½ watt end of line resistor
3 # 6x3/8 self-tapping sheet metal screws to secure the
module to mounting skirt or enclosure
Technical specifications
Environmental Considerations
Relative Humidity Up to 93% non-condensing
Temperature Operating 0° to +49°C (+32° to +120°F)
Electrical Requirements
Current Draw: 110 mA max (Board) +150 mA max
Voltage (operating) 8.5 – 13.8 V
(Reader)
Reader Requirements
+5.2 VDC Power out to 5.2
VDC card reader
DATA 0 Data 0 input
from card reader
DATA 1 Data 1 input
from card reader
BUZZER Buzzer common
upon strike activation
LED LED common
upon card read response and strike activation
5 V +/- 0.25 V for 20 to 140 mA load 150 mA maximum continuous
High impedance input with 47 kΩ pull up to +5.2 V
High impedance input with 47 kΩ pull up to +5.2 V
Sink up to 35 mA from 5-14 VDC source Output impedance is 100Ω
Sink up to 35 mA from 5-14 VDC source Output impedance is 180Ω
Loading...