Bosch B430 Installation Manual

2.2 | Wire the module
Installing the module:
1. With the module facing the control panel as shown below, insert the support leg into the support hole labeled X.
2. Align the PCB metal contacts with the on-board connector.
Figure 2.1: Module installation
Callout ― Description
1 ― Support leg inserted into the control panel support hole labeled X
2 ― PCB metal contacts resting on the on-board connector
3 ― Plug-in module retention clip
Connect one end of a compatible telephone cord to the B430, and connect the other end to an RJ31X or RJ38X phone jack that is connected to the phone line. The module has pads on both sides of the board to connect a telephone test set. Refer to Figure
2.2.
Figure 2.2: Wiring the module
Callout ― Description
1 ― Premises telephone
2 ― Incoming Telco line
3 ― Installer telephone test set
4 ― RJ45 phone connector
The B430 Plug-in Telephone Communicator provides communication over the PSTN (Public Switched Telephone Network) by directly connecting the module to the control panel. The module provides a single telephone jack and easily installs into an on-board connector. You can program, diagnose, and troubleshoot the system from the control panel keypad as well as remotely through RPS.
Callout ― Description
1 ― Module handle and support leg
2 ― Line seize/ring LED
3 ― Test phone pads
4 ― RJ45 phone connector
5 ― Plug-in module retention clip opening
6 ― PCB metal contacts
Figure 1.1: Module overview
NOTICE!
Remove all power (AC and battery) before making any connections. Failure to do so might result in personal injury and/or equipment damage.
2 | Install or remove the module
2.1 | Install the module
The control panel communicates with and provides power to the module through the plug-in connection. Proper installation results in the necessary electrical and mechanical connection.
1 | Overview
To remove an installed module, hold the plug-in module retention clip open with one hand while grasping the top corners of the module support handle with your other hand. Pull the module out.
2.3 | Remove the module
1
2
3
4
5
6
1
© 2015 Bosch Security Systems, Inc.
F.01U.265.454 | 05 | 2015.05
en Installation Guide
Plug-in Telephone Communicator
B430
Bosch Security Systems, Inc.
130 Perinton Parkway Fairport, NY 14450 USA
www.boschsecurity.com
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5 85630 Grasbrunn Germany
Copyright
This document is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved.
Trademarks
All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
Bosch Security Systems, Inc. product manufacturing dates
Use the serial number located on the product label and refer to the Bosch Security Systems, Inc. website at http://www.boschsecurity.com/datecodes/.
The module uses a green LED to indicate when the circuit is on or off the hook or the phone line is ringing. Refer to Table
3.1.
3 | LED descriptions
Use Remote Programming Software (RPS) or an SDI2 keypad to program the control panel to use the module for communication.
For programming parameter descriptions, options, and defaults refer to RPS Help or the Program Entry Guide for your control panel.
4 | Confi guration
Flash pattern Function
OFF Steady Standby
ON Steady Line seize
Flash Ring detect
Table 3.1: Diagnostic LED fl ash patterns
Dimensions 2 in x 3.68 in x 0.60 in
(50 mm x 93.5 mm x 15.25 mm)
Voltage (operating) 12 VDC nominal
Current (maximum) Standby: 24 mA
Alarm: 24 mA
Operating temperature +32°F to +120°F (0°C to +49°C)
Relative humidity 5% to 93% at +90°F (+32°C )
Communication speed 2400 baud maximum
Compatibility B9512G/B9512G-E
B8512G/B8512G-E B5512/B5512E B4512/B4512E B3512/B3512E
6 | Specifi cations
Region Certifi cation
US UL 365 - Police Station Connected Burglar Alarm Units and Systems
UL 636 - Holdup Alarm Units and Systems UL 864 - Control Units and Accessories for Fire Alarm Systems (Commercial Fire) UL 985 - Household Fire Warning System Units UL 1023 - Household Burglar Alarm System Units UL 1076 - Proprietary Burglar Alarm Units and Systems UL 1610 - Central Station Burglar Alarm Units FCC Part 15
FCC Part 68
FCC Registration Number: ESVAL00BB430
Ringer Eq: 0.0B
Canada CAN/ULC S303 - Local Burglar Alarm Units and Systems
CAN/ULC S304 - Signal Receiving Centre and Premise CAN/ULC S545 - Residential Fire Warning System Control ICES-003 - Information Technology Equipment (ITE) ULC-ORD C1023 - Household Burglar Alarm System Units ULC-ORD C1076 - Proprietary Burglar Alarm Units and System
5 | Certifi cations