The ARD-AYK12 is a RFID proximity card reader to be installed for use with access control systems.
This installation manual contains the following information:
- Mounting Instructions
- Wiring Instructions
-Operation Instructions
- Technical Specifications

MOUNTING INSTRUCTIONS

1 = To remove the top cover you need to unscrew the top
cover screw located on the bottom of the reader.
2 = Remove the top cover to reveal the screw holes for
mounting.
Mount the reader with the appropriate screws (not supplied) as indicated on the template. To mount the reader, perform the following:
1. Determine an appropriate mounting position for the reader.
2. Peel off the back of the self-stick mounting label template included with the unit and place at the desired mounting position. If you do not have the self-stick mounting
Bosch Sicherheitssyteme GmbH | V 1.2 | 2009.09
6 en | Installation Manual ARD-AYK12
template label, refer to the Mounting Diagrams in this manual for the dimensions.
3. Using the template as a guide, drill the holes (hole size is indicated on mounting template) for mounting the reader to the surface.
4. Drill a
7/16" (10 mm) hole for the cable. If mounting on
metal, place a grommet or electrical tape around the edge of the hole.
5. Route the interface cable from the reader to the controller. A linear type power supply is recommended
NOTICE!
Card readers are to be used with a listed access control unit whose power supply is UL Listed Class 2 or equivalent.

WIRING INSTRUCTIONS

The ARD-AYK12 is supplied with an 18 inch (45 cm) pigtail, having a 6-conductor cable. To connect the reader to the controller, perform the following steps:
1. Prepare the reader cable by cutting the cable jacket back
1/4 inches (3,4 cm) and strip the wires 1/2 inch (1,3 cm).
1
2. Prepare the controller cable by cutting the cable jacket back 1
1/4 inches (3,4 cm) and strip the wires 1/2 inch
(1,3 cm).
3. Splice the reader pigtail wires to the corresponding controller wires and cover each connection with insulating tape.
4. If the tamper output is being utilized, connect the purple wire to the correct input on the controller.
5. Trim and cover all conductors that are not used.
The table below shows how you should wire the reader to the controller.
Color Wiegand Output
Red DC + Input Black Ground White Data 1 Green Data 0
| V 1.2 | 2009.09 Bosch Sicherheitssyteme GmbH
ARD-AYK12 Installation Manual | en 7
Color Wiegand Output
Brown LED Control Purple Tamper
Cable Notes:
1. The individual wires coming out of the reader are color coded according to the recommended Wiegand standard.
2. When using a separate power supply for the reader, this supply and the controller's power supply must have a common ground.
3. The cable shield wire on the reader should be attached to an earth ground (best) or signal ground connection at the panel or power supply end of the cable. This configuration is best for shielding the reader cable from external interference.

OPERATION INSTRUCTIONS

The reader should be tested after wiring it to a power supply and the controller.
Do this by performing the following steps:
1. Power up the reader. The LED and beeper will activate three times. This indicates that the reader is working properly.
2. Present the appropriate type of proximity card to the reader. The LED will momentarily flash green and a short beep will be emitted. This indicates that the card was read properly by the Proximity Card Reader.
3. After the card data is processed by the controller, the controller can then turn the LED green. Refer to the controller description of the LED operation if the reader LED is controlled by the controller.
Bosch Sicherheitssyteme GmbH | V 1.2 | 2009.09
8 en | Installation Manual ARD-AYK12

TECHNICAL SPECIFICATIONS

Electrical Characteristics
Power Supply Type Linear type recommended Operating Voltage Range 5 - 16 VDC Maximum Input Current Standby: 35 mA
Read: 50 mA
Tamper Output Open collector, active low, max
sink current 16 mA
Max Cable Distance to
500 ft. (150 meters)
Controller Output modulation 26-bit Wiegand Card read distance* 3.15 inch (8 cm) RF Modulation ASK Regulatory Approvals USA: UL 294 & FCC Part 15B
Europe: CE Listed
Environmental Characteristics
Operating Temp. Range -25°F to 145°F (-31°C to 63°C ) Operating Humidity 0 to 95% (non condensing)
Dimensions
Height x Widht X Depth 3.15 x 1.57 x 0.50 inch
(79.91 x 39.91 x 12.8 mm)
* Measured using Bosch Proximity Card (P/N ACD-ATR11ISO) or equivalent. Range also depends on electrical environment and/ or proximity to metal.
Suitable for Outdoor Use
| V 1.2 | 2009.09 Bosch Sicherheitssyteme GmbH
ARD-AYK12 Installation Manual | en 9

MOUNTING DIAGRAM

Bosch Sicherheitssyteme GmbH | V 1.2 | 2009.09
10 en | Installation Manual ARD-AYK12
| V 1.2 | 2009.09 Bosch Sicherheitssyteme GmbH
ARD-AYK12 Installationshandbuch | de 11

Installationshandbuch

Der ARD-AYK12 ist ein RFID-Leser für berührungslose Ausweise und kann in Zutrittskontrollsysteme installiert werden.
Dieses Installationshandbuch enthält folgende Informationen:
-Montageanleitung
- Verkabelungsanleitung
- Bedienungsanleitung
-Technische Daten

MONTAGEANLEITUNG

1 = Um die obere Abdeckung zu entfernen, muss die an der
Unterseite des Lesers befindliche Schraube der oberen Abdeckung abgeschraubt werden.
2 = Entfernen Sie die obere Abdeckung, um die
Schraubenöffnungen für die Montage freizulegen.
Montieren Sie den Leser wie auf der Schablone angegeben mit den entsprechenden Schrauben (nicht im Lieferumfang enthalten). Gehen Sie zur Montage des Lesers wie folgt vor:
1. Legen Sie eine geeignete Montageposition für den Leser fest.
2. Ziehen Sie die Rückseite der mit dem Gerät mitgelieferten selbstklebenden Montagemarkierungsschablone ab, und
Bosch Sicherheitssyteme GmbH | V 1.2 | 2009.09
12 de | Installationshandbuch ARD-AYK12
bringen Sie die Schablone an der gewünschten Montageposition an. Wenn Sie über keine selbstklebende Montagemarkierungsschablone verfügen, können Sie die Abmessungen aus den Montagedarstellungen in diesem Handbuch entnehmen.
3. Bohren Sie die Löcher (der Bohrungsdurchmesser ist auf der Montageschablone angegeben) für die Montage des Lesers auf der entsprechenden Oberfläche.
4. Bohren Sie ein Loch mit
10 mm Durchmesser für das Kabel.
Bei der Montage auf Metall ist die Bohrungskante mit einer Schutzmanschette oder mit Isolierband zu versehen .
5. Führen Sie das Schnittstellenkabel vom Leser zum Kontroller. Es wird empfohlen, ein Netzteil mit linearer Spannungsregelung zu verwenden.
HINWEIS!
Kartenleser müssen zusammen mit einem zugelassenen Zutrittskontrollgerät verwendet werden, dessen Netzteil CE­zugelassen ist bzw. das mit einem gleichwertigen Netzteil ausgestattet ist.

VERKABELUNGSANLEITUNG

Der ARD-AYK12 wird mit einem 45 cm langen 6-adrigen Anschlusskabel geliefert. Gehen Sie zum Anschließen des Lesers an den Kontroller wie folgt vor:
1. Bereiten Sie das Leser-Kabel vor, indem Sie den Kabelmantel auf einer Länge von Drähte auf einer Länge von
3,4 cm entfernen und die
1,3 cm abisolieren.
2. Bereiten Sie das Kontroller-Kabel vor, indem Sie den Kabelmantel auf einer Länge von 3,4 cm entfernen und die Drähte auf einer Länge von
1,3 cm abisolieren.
3. Verbinden Sie die Drähte der Anschlussleitung des Lesers mit den entsprechenden Drähten des Controller-Kabels, und isolieren Sie alle Verbindungsstellen mit Isolierband.
4. Wenn der Sabotageausgang verwendet wird, schließen Sie den violetten Draht an den entsprechenden Eingang am Controller an.
5. Schneiden Sie alle nicht verwendeten Leiter zurück, und isolieren Sie sie entsprechend.
| V 1.2 | 2009.09 Bosch Sicherheitssyteme GmbH