This manual provides information on installing and operating the
following three-phase Rack Power Distribution Units (
PDUs):
Metered PDU
AP7862J:
NEMA L21-20 plug42 NEMA 5-15 outlets
Basic PDU
AP7562J:
NEMA L21-20 plug42 NEMA 5-15 outlets
Metered PDU — Metered PDUs distribute power to devices in the
rack. These
used by the
monitored through Web, Control Console,
PDUs have a sensor that measures the current being
PDU and it’s attached devices. The sensor can be
SNMP, or InfraStruXure
Manager interfaces.
Basic PDU—Basic PDUs distribute power to devices in the rack.
Display Interface—The display interface on Metered PDUs
shows the aggregate current being used by the
PDU and its
attached devices. An alarm occurs if the aggregate current is above
the high threshold value or below the low threshold values that
you configure.
L21-20 plug—Both PDUs have an L21-20 plug, which connects to
a variety of
APC equipment, including InfraStruXure PDU power
cables and Rack Automatic Transfer Switches.
Basic and Metered Rack Power Distribution Unit1
Product Description and Inventory
Additional
documentation
Inventory
The Metered Rack PDU User’s Guide and the Metered Rack PDU
Addendum are available on the supplied CD or on our Web site:
http://www.apc.com/.
The online user’s guide (.\Doc\eng\usrguide.pdf) contains additional
information about the following topics related to the
PDU:
• Management interfaces
• User accounts
• Customizing setup
•Security
The addendum (.\Doc\eng\addendum.pdf) contains additional
information about the following topics:
• The Wizard
• Configuration utilities
• File transfers
QuantityItem
1Configuration cable (940-0144) included
with the AP7862J only
Receiving inspection
Please recycle
InfraStruXure certified
3 Cord retention tray (with 12 flat-head screws
and 42 wire ties)
1APC Basic and Metered Power Distribution
Units Utility CD
1Warranty registration card
Inspect the package and contents for shipping damage, and make sure
that all parts were sent. Report any damage immediately to the shipping
agent, and report missing contents, damage, or other problems
immediately to APC or your APC reseller.
The shipping materials are recyclable. Please save them for
later use, or dispose of them appropriately.
This product is certified for use in InfraStruXure systems. See the
InfraStruXure Manager’s configuration instructions included with your
system.
2Basic and Metered Rack Power Distribution Unit
How to Install the Basic and Metered PDU
Attach the cord
retention trays
Attach cords to the tray
Attach the cord retention trays to the PDU, using four flat-head screws
(provided) per tray.
Attach a cord to the tray by looping the cord and securing it to the tray,
using a wire tie (provided).
Mounting options
Each cord must be secured to the tray so that you can
unplug it from the
Note
Install the PDU in the rear of the NetShelter VX Enclosure, in the cable
channel directly behind the rear vertical mounting rails. You can install
the
PDU in one of two ways: using toolless mounting pegs (provided) or
the mounting brackets (sold separately).
You can order a rack-mount bracket kit from APC
(
AR8116BLK).
Note
PDU without removing the wire tie.
Basic and Metered Rack Power Distribution Unit3
How to Install the Basic and Metered PDU
Toolless mounting
1. Slide the mounting pegs into the holes located in the channel in the
rear panel of the enclosure.
2. Snap the
PDU into place by pushing it downward until it locks into
position.
Note
You can mount two PDUs on one side of the enclosure by
using the toolless mounting method.
4Basic and Metered Rack Power Distribution Unit
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.