Amana AMVC80704BX, AMVC80905CX, AMVC81155CX, ADVC80703BX, ADVC80905CX User Manual

...
0 (0)

Downloaded from www.rsandrews.com. Since 1968, RS Andrews has proudly served Atlanta's Heating, Air Conditioning & Plumbing Needs.

80%AFUE

Heating Input:70,000–115,000BTU/h

StandardFeatures

MillionAir® stainless-steel, dualdiameter tubular heat exchanger

Two-stage gas valve operates on two-stage or single-stage thermostats

ComfortNet™ Communications System compatible

Efficient and quiet variable-speed ECM circulator motor gently ramps up or down according to heating or cooling demand

SureStart® Silicon Nitride igniter designed for long igniter life

Furnace control board with self-diagnostics, colorcoded low-voltage terminals, and provisions for electronic air cleaner and 120-volt or 24-volt humidifiers

Low constant fan speed allows homeowner to activate a very low speed to efficiently circulate air throughout the home. This setting costs as little as a 100-watt light bulb to operate.

Quiet, two-speed induced draft blower

All models comply with California NOx emissions standards

CabinetFeatures

Fully insulated, heavy-gauge steel cabinet with durable baked-enamel finish

Designed for multi-position installation: upflow, horizontal left or right

Removable bottom for sideor bottom-return applications

Convenient left or right connection for gas/electric service

Coil and furnace fit flush for most installations

AMVC8/ADVC8

Two-Stage,Variable Speed

Gas Furnace

Contents

 

Nomenclature.....................................................................

2

Product Specifications........................................................

3

Dimensions.........................................................................

4

Airflow Data........................................................................

5

Wiring Diagrams ..............................................................

10

Accessories........................................................................

12

* Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the Lifetime Unit Replacement Limited Warranty and Lifetime Heat Exchanger Limited Warranty (in both cases, good for as long as you own your home) plus the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec.

SS-AMVC8

www.amana-hac.com

8/10

Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas.

Supersedes 3/10

Product Specifications

Nomenclature

 

 

 

 

A

M

V

 

C

8

070

 

4

 

C

X

 

A

A

 

 

 

 

 

1

 

2

 

3

4

5

6,7,8

 

9

 

10

 

11

12

 

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Brand

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Revisions

 

 

A

Amana® Brand

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Major and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minor Revisions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow Direc5on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOx

 

 

C

Downflow/Horizontal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

Natural Gas

 

 

D

Dedicated Downflow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

Low NOx

 

 

H

High Airflow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K

Dedicated Upflow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cabinet Width

 

 

M

Upflow/Horizontal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A 14”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B 17½”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Descrip5on/Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C 21”

 

 

V

Two-­Stage/Variable-­speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D 24½”

 

 

H

Two-­Stage/MulS-­speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

Single-­Stage/MulS-­speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum CFM @ 0.5” ESP

 

 

E

Two-­Stage/High-­E ciency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 1200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 1600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SystemType

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 2000

 

 

C

ComfortNet™ CommunicaSng System

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBTU/h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AFUE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

045: 45,000

 

 

115: 115,000

 

 

95

95%

8 80%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

070: 70,000

 

 

140: 140,000

 

 

9

90%+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

090: 90,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

www.amana-hac.com

SS-AMVC8

Product Specifications

Specifications

 

AMVC8

AMVC8

AMVC8

ADVC8

ADVC8

ADVC8

 

0704BX*

0905CX*

1155CX*

0703BX*

0905CX*

1155CX*

 

 

 

 

 

 

 

Heating Capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

High Fire Input (BTU/h)¹

70,000

90,000

115,000

70,000

90,000

115,000

 

 

 

 

 

 

 

High Fire Output (BTU/h)¹ (below)

 

 

 

 

 

 

 

 

 

 

 

 

 

Natuarl Gas

57,000

74,000

93,000

57,000

74,000

93,000

 

 

 

 

 

 

 

LP Gas

50,400

64,000

82,000

50,400

64,000

82,000

 

 

 

 

 

 

 

Low Fire Input (BTU/h)¹

49,000

63,000

80,000

49,000

63,000

80,000

 

 

 

 

 

 

 

Low Fire Output (BTU/h)¹ (below)

 

 

 

 

 

 

 

 

 

 

 

 

 

Natuarl Gas

39,200

50,400

64,000

39,200

50,400

64,000

 

 

 

 

 

 

 

LP Gas

39,200

50,400

64,000

39,200

50,400

64,000

 

 

 

 

 

 

 

AFUE2

80

80

80

80

80

80

 

 

 

 

 

 

 

Available AC @ 0.5” ESP

1.5 - 3.0

2.0 - 5.0

2.0 - 5.0

1.5 - 3.0

2.0 - 5.0

2.0 - 5.0

 

 

 

 

 

 

 

Temperature Rise Range (° F)

20 - 50

20 - 50

25 - 55

30-60

30-60

35-65

 

 

 

 

 

 

 

Circulator Blower

 

 

 

 

 

 

 

 

 

 

 

 

 

Size (D x W)

10” x 8”

10” x 10”

10” x 10”

10” x 8”

10” x 10”

10” x 10”

 

 

 

 

 

 

 

Horsepower - RPM

¾

¾

¾

¾

¾

¾

 

 

 

 

 

 

 

Speed

 

Variable

 

 

Variable

 

 

 

 

 

 

 

 

Vent Diameter²

4”

4”

4”

4”

4”

4”

 

 

 

 

 

 

 

No. of Burners

3

4

5

3

4

5

 

 

 

 

 

 

 

Disposable Filter Size (in²)

818

960

960

713

960

960

 

 

 

 

 

 

 

Electrical Data

 

 

 

 

 

 

 

 

 

 

 

 

 

Min. Circuit Ampacity³

12.1

12.1

12.1

12.1

12.1

12.1

 

 

 

 

 

 

 

Max. Overcurrent Device (amps)

15

15

15

15

15

15

 

 

 

 

 

 

 

Ship Weight (lbs)

138

156

158

155

177

179

 

 

 

 

 

 

 

1Natural Gas BTU/h. For altitudes above 2,000’, reduce input rating 4% for each 1,000’ above sea level.

2 DOE AFUE based upon Isolated Combustion System (ICS)

3Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

4Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.

Notes

All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.

Gas Service Connection ½” FPT

Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.

SS-AMVC8

www.amana-hac.com

3

Amana AMVC80704BX, AMVC80905CX, AMVC81155CX, ADVC80703BX, ADVC80905CX User Manual

Product Specifications

AMVC8 Dimensions

Minimum Clearances to Combustible Materials

Sides

Rear

Front¹

 

Vent²

Top

 

 

 

SW

 

B

 

 

 

 

 

 

 

 

 

 

 

 

1

0

3

6

 

1

1

 

 

 

 

 

 

 

See Notes below.

ADVC8Dimensions

Dimensions

Model

A

B

 

 

 

AMVC80704BX

17½”

16”

 

 

 

AMVC80905CX

21”

19½”

 

 

 

AMVC81155CX

21”

19½”

 

 

 

Minimum Clearances to Combustible Materials

Sides

Rear

Front¹

 

Vent²

Top

 

 

 

SW

 

B

 

 

 

 

 

 

 

 

 

 

 

 

1

0

3

6

 

1

1

 

 

 

 

 

 

 

Approved for line contact in the horizontal position.

Dimensions

Model

A

B

 

 

 

ADVC80703BX

17½”

16”

 

 

 

ADVC80905CX

21”

19½”

 

 

 

ADVC81155CX

21”

19½”

 

 

 

¹24” clearance for serviceability recommended.

²SingleWallVent(SW)tobeusedonlyasaconnector.RefertotheventingtablesoutlinedintheInstallationManualforadditionalventingrequirements.

4

www.amana-hac.com

SS-AMVC8

Loading...
+ 8 hidden pages