80%AFUE
Heating Input:70,000–115,000BTU/h
StandardFeatures
•MillionAir® stainless-steel, dualdiameter tubular heat exchanger
•Two-stage gas valve operates on two-stage or single-stage thermostats
•ComfortNet™ Communications System compatible
•Efficient and quiet variable-speed ECM circulator motor gently ramps up or down according to heating or cooling demand
•SureStart® Silicon Nitride igniter designed for long igniter life
•Furnace control board with self-diagnostics, colorcoded low-voltage terminals, and provisions for electronic air cleaner and 120-volt or 24-volt humidifiers
•Low constant fan speed allows homeowner to activate a very low speed to efficiently circulate air throughout the home. This setting costs as little as a 100-watt light bulb to operate.
•Quiet, two-speed induced draft blower
•All models comply with California NOx emissions standards
CabinetFeatures
•Fully insulated, heavy-gauge steel cabinet with durable baked-enamel finish
•Designed for multi-position installation: upflow, horizontal left or right
•Removable bottom for sideor bottom-return applications
•Convenient left or right connection for gas/electric service
•Coil and furnace fit flush for most installations
AMVC8/ADVC8
Two-Stage,Variable Speed
Gas Furnace
Contents |
|
Nomenclature..................................................................... |
2 |
Product Specifications........................................................ |
3 |
Dimensions......................................................................... |
4 |
Airflow Data........................................................................ |
5 |
Wiring Diagrams .............................................................. |
10 |
Accessories........................................................................ |
12 |
* Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the Lifetime Unit Replacement Limited Warranty and Lifetime Heat Exchanger Limited Warranty (in both cases, good for as long as you own your home) plus the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec.
SS-AMVC8 |
www.amana-hac.com |
8/10 |
Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas. |
Supersedes 3/10 |
Product Specifications
Nomenclature
|
|
|
|
A |
M |
V |
|
C |
8 |
070 |
|
4 |
|
C |
X |
|
A |
A |
|
|
|||||||
|
|
|
1 |
|
2 |
|
3 |
4 |
5 |
6,7,8 |
|
9 |
|
10 |
|
11 |
12 |
|
13 |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Brand |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Revisions |
|
|
A |
Amana® Brand |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Major and |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Minor Revisions |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Airflow Direc5on |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOx |
|
|
|
C |
Downflow/Horizontal |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N |
Natural Gas |
|
|||
|
D |
Dedicated Downflow |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X |
Low NOx |
|
|||
|
H |
High Airflow |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
K |
Dedicated Upflow |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Cabinet Width |
|
|||
|
M |
Upflow/Horizontal |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
A 14” |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
B 17½” |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Descrip5on/Motor |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C 21” |
|
|
|
V |
Two-Stage/Variable-speed |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
D 24½” |
|
|||
|
H |
Two-Stage/MulS-speed |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S |
Single-Stage/MulS-speed |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Maximum CFM @ 0.5” ESP |
|
||||
|
E |
Two-Stage/High-E ciency |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 1200 |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 1600 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SystemType |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 2000 |
|
|
|
C |
ComfortNet™ CommunicaSng System |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MBTU/h |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
AFUE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
045: 45,000 |
|
|
115: 115,000 |
|
||
|
95 |
95% |
8 80% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
070: 70,000 |
|
|
140: 140,000 |
|
||||
|
9 |
90%+ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
090: 90,000 |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
www.amana-hac.com |
SS-AMVC8 |
Product Specifications
Specifications
|
AMVC8 |
AMVC8 |
AMVC8 |
ADVC8 |
ADVC8 |
ADVC8 |
|
0704BX* |
0905CX* |
1155CX* |
0703BX* |
0905CX* |
1155CX* |
|
|
|
|
|
|
|
Heating Capacity |
|
|
|
|
|
|
|
|
|
|
|
|
|
High Fire Input (BTU/h)¹ |
70,000 |
90,000 |
115,000 |
70,000 |
90,000 |
115,000 |
|
|
|
|
|
|
|
High Fire Output (BTU/h)¹ (below) |
|
|
|
|
|
|
|
|
|
|
|
|
|
Natuarl Gas |
57,000 |
74,000 |
93,000 |
57,000 |
74,000 |
93,000 |
|
|
|
|
|
|
|
LP Gas |
50,400 |
64,000 |
82,000 |
50,400 |
64,000 |
82,000 |
|
|
|
|
|
|
|
Low Fire Input (BTU/h)¹ |
49,000 |
63,000 |
80,000 |
49,000 |
63,000 |
80,000 |
|
|
|
|
|
|
|
Low Fire Output (BTU/h)¹ (below) |
|
|
|
|
|
|
|
|
|
|
|
|
|
Natuarl Gas |
39,200 |
50,400 |
64,000 |
39,200 |
50,400 |
64,000 |
|
|
|
|
|
|
|
LP Gas |
39,200 |
50,400 |
64,000 |
39,200 |
50,400 |
64,000 |
|
|
|
|
|
|
|
AFUE2 |
80 |
80 |
80 |
80 |
80 |
80 |
|
|
|
|
|
|
|
Available AC @ 0.5” ESP |
1.5 - 3.0 |
2.0 - 5.0 |
2.0 - 5.0 |
1.5 - 3.0 |
2.0 - 5.0 |
2.0 - 5.0 |
|
|
|
|
|
|
|
Temperature Rise Range (° F) |
20 - 50 |
20 - 50 |
25 - 55 |
30-60 |
30-60 |
35-65 |
|
|
|
|
|
|
|
Circulator Blower |
|
|
|
|
|
|
|
|
|
|
|
|
|
Size (D x W) |
10” x 8” |
10” x 10” |
10” x 10” |
10” x 8” |
10” x 10” |
10” x 10” |
|
|
|
|
|
|
|
Horsepower - RPM |
¾ |
¾ |
¾ |
¾ |
¾ |
¾ |
|
|
|
|
|
|
|
Speed |
|
Variable |
|
|
Variable |
|
|
|
|
|
|
|
|
Vent Diameter² |
4” |
4” |
4” |
4” |
4” |
4” |
|
|
|
|
|
|
|
No. of Burners |
3 |
4 |
5 |
3 |
4 |
5 |
|
|
|
|
|
|
|
Disposable Filter Size (in²) |
818 |
960 |
960 |
713 |
960 |
960 |
|
|
|
|
|
|
|
Electrical Data |
|
|
|
|
|
|
|
|
|
|
|
|
|
Min. Circuit Ampacity³ |
12.1 |
12.1 |
12.1 |
12.1 |
12.1 |
12.1 |
|
|
|
|
|
|
|
Max. Overcurrent Device (amps) |
15 |
15 |
15 |
15 |
15 |
15 |
|
|
|
|
|
|
|
Ship Weight (lbs) |
138 |
156 |
158 |
155 |
177 |
179 |
|
|
|
|
|
|
|
1Natural Gas BTU/h. For altitudes above 2,000’, reduce input rating 4% for each 1,000’ above sea level.
2 DOE AFUE based upon Isolated Combustion System (ICS)
3Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
4Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
•All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
•Gas Service Connection ½” FPT
•Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.
SS-AMVC8 |
www.amana-hac.com |
3 |
Product Specifications
AMVC8 Dimensions
Minimum Clearances to Combustible Materials
Sides |
Rear |
Front¹ |
|
Vent² |
Top |
|
|
|
|
||||
SW |
|
B |
||||
|
|
|
|
|
||
|
|
|
|
|
|
|
1 |
0 |
3 |
6 |
|
1 |
1 |
|
|
|
|
|
|
|
See Notes below.
ADVC8Dimensions
Dimensions
Model |
A |
B |
|
|
|
AMVC80704BX |
17½” |
16” |
|
|
|
AMVC80905CX |
21” |
19½” |
|
|
|
AMVC81155CX |
21” |
19½” |
|
|
|
Minimum Clearances to Combustible Materials
Sides |
Rear |
Front¹ |
|
Vent² |
Top |
|
|
|
|
||||
SW |
|
B |
||||
|
|
|
|
|
||
|
|
|
|
|
|
|
1 |
0 |
3 |
6 |
|
1 |
1 |
|
|
|
|
|
|
|
Approved for line contact in the horizontal position.
Dimensions
Model |
A |
B |
|
|
|
ADVC80703BX |
17½” |
16” |
|
|
|
ADVC80905CX |
21” |
19½” |
|
|
|
ADVC81155CX |
21” |
19½” |
|
|
|
¹24” clearance for serviceability recommended.
²SingleWallVent(SW)tobeusedonlyasaconnector.RefertotheventingtablesoutlinedintheInstallationManualforadditionalventingrequirements.
4 |
www.amana-hac.com |
SS-AMVC8 |