Allied Telesis, Inc. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesis, Inc. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesis, Inc. has been advised of, known, or should have known, the possibility of such damages.
Electrical Safety and Emissions Standards
This product meets the following standards.
U.S. Federal Communications Commission
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses , and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
RFI Emissions FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-3-3, C-TICK,
CE
Warning: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Immunity EN55024 Electrical Safety EN60950 (TUV), UL 60950 (
CULUS
)
Laser Safety EN60825
3
Translated Safety Statements
Important: The indicates that translations of the safety statement are available in the PDF document “Translated Safety Statements” posted on the Allied Telesis website at www.alliedtelesis.com.
4

Contents

Preface ............................................................................................................................................................ 11
Symbol Conventions..................................... ....................................... ... ... ................................................ 11
Contacting Allied Telesis............................................................................................................................ 12
Chapter 1: Overview ..................................................................................................................................... 13
Features..................................................................................................................................................... 13
Twisted Pair Ports ............................................................................................................................... 13
LEDs.................................................................................................................................................... 14
SFP Slots............................................................................................................................................. 14
Installation Options.............................................................................................................................. 14
Power Conservation ............................................................................................................................ 14
MAC Address Table ............................................................................................................................ 14
Management Software ........................................................................................................................ 15
Management Interface......................................................................................................................... 15
Dimensions.......................................................................................................................................... 15
Operating Conditions.................... .... ... ....................................... ... ... ................................................... 15
Front and Back Panels............................................................................................................................... 16
Management Software............................................................................................................................... 17
Twisted Pair Ports...................................................................................................................................... 17
Combo Ports.............................................................................................................................................. 18
LEDs .......................................................................................................................................................... 20
eco-friendly Button..................................................................................................................................... 21
Power Supply............................................................................................................................................. 22
Network Topologies ................................................................................................................................... 23
Gigabit Ethernet to the Desktop .......................................................................................................... 23
Gigabit Ethernet Backbone.................................................................................................................. 23
Chapter 2: Installation ......................................... ....................................................................... ................... 25
Reviewing Safety Precautions ................................................................................................................... 26
Selecting a Site for the Switch ................................................................................................................... 28
Cable Specifications................................................................................................................................... 29
Unpacking the Switch................................................................................................................................. 30
Installing the Switch on a Desktop............................................................................................................. 31
Installing the Switch in an Equipment Rack............................................................................................... 32
Installing the Switch on a Wall ................................................................................................................... 35
Installing Optional SFP Transceivers......................................................................................................... 37
Cabling the Switch ..................................................................................................................................... 40
Powering On the Switch............................................................................................................................. 41
Chapter 3: Troubleshooting .......................................................................................................................... 43
Appendix A: Technical Specifications ............................................................................................................ 47
Physical Specifications............................................................................................................................... 48
Dimensions (H x W x D)................................................................................................................ 48
Weights......................................................................................................................................... 48
Environmental Specifications..... ... ....................................... ... ... ....................................... ... ... ................... 49
Power Specifications.................................................................................................................................. 49
5
Contents
Certifications...............................................................................................................................................49
Connectors and Port Pinouts......................................................................................................................50
6

List of Figures

Figure 1: AT-GS950/8, AT-GS950/16, AT-GS950/24 and AT-GS950/48 Front Panels...................................................... 16
Figure 2: Back Panel........................................................................................................................................................... 17
Figure 3: Gigabit Ethernet to the Desktop Topology............................................................................................................ 23
Figure 4: Gigabit Ethernet Backbone Topology ................................................................................................................... 24
Figure 5: AT-GS950/xx Packing List.................................................................................................................................... 30
Figure 6: Attaching the Rubber Feet ................................................................................................................................... 31
Figure 7: Attaching the Rack-Mount Brackets to the Switch................................................................................................ 33
Figure 8: Mounting the Switch in an Equipment Rack......................................................................................................... 34
Figure 9: Attaching the Brackets to Install the Switch on a Wall......................................... ... .............................................. 35
Figure 10: Marking the Screw Hole Locations..................................................................................................................... 35
Figure 11: Securing the Switch to the Wall.......................................................................................................................... 36
Figure 12: Removing the Dust Plug from an SFP Slot ........................................................................................................ 37
Figure 13: Inserting the SFP................................................................................................................................................ 38
Figure 14: Plugging in the AC Power Cord.......................................................................................................................... 41
Figure 15: RJ-45 Connector and Port Pin Layout................................................................................................................ 50
7
List of Figures
8

List of Tables

Table 1. Combo Ports .........................................................................................................................................................18
Table 2. System LEDs ........................................................................................................................................................20
Table 3. 10/100/1000Base-T Port LEDs .............................................................................................................................20
Table 4. SFP Slot LEDs ......................................................................................................................................................21
Table 5. Twisted Pair Cabling and Distances .....................................................................................................................29
Table 6. Product Dimensions ..............................................................................................................................................48
Table 7. Product Weights ...................................................................................................................................................48
Table 8. Environmental Specifications ................................................................................................................................49
Table 9. Power Consumption .............................................................................................................................................49
Table 10. Product Certifications ..........................................................................................................................................49
Table 11. MDI Pin Signals (10Base-T or 100Base-TX) ......................................................................................................50
Table 12. MDI-X Pin Signals (10Base-T or 100Base-TX) ..................................................................................................50
Table 13. RJ-45 1000Base-T Connector Pinouts ...............................................................................................................51
9
List of Tables
10

Preface

Note
Caution
Warning
Warning
This guide contains the installation instructions for the AT-GS950/8, AT-GS950/16, AT-GS950/24 and AT-GS950/48 Gigabit Ethernet Smart Switches. The overview gives a physical description of the switch hardware and the instructions give the installation procedures.
This preface contains the following sections:
“Symbol Conventions” on page 11“Contacting Allied Telesis” on page 12

Symbol Conventions

This document uses the following conventions:
Notes provide additional information.
Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data.
Warnings inform you that performing or omitting a specific action may result in bodily injury.
Warnings inform you that an eye and skin hazard exists due to the presence of a Class 1 laser device.
11
Preface

Contacting Allied Telesis

If you need assistance with this product, you may contact Allied Telesis technical support by going to the Support & Services section of the Allied Telesis web site at www.alliedtelesis.com/support. You can find links for the following services on this page:
24/7 Online Support - Enter our interactive support
USA and EMEA phone support - Select the phone
Hardware warranty information - Learn about Allied
Replacement Services - Submit a Return Merchandise
center to search for answers to your questions in our knowledge database, check support tickets, learn about RMAs, and contact Allied Telesis technical experts.
number that best fits your location and customer type.
Telesis warranties and register your product online.
Authorization (RMA) request via our interactive support center.
Documentation - View the most recent installation
guides, user guides, software release notes, white papers and data sheets for your product.
Software Updates - Download the latest software
releases for your product.
For sales or corporate contact information, go to
www.alliedtelesis.com/purchase and select your region.
12

Chapter 1

Overview

This chapter describes the AT-GS950/8, AT-GS950/16, AT-GS950/24 and AT-GS950/48 Layer 2 Gigabit Ethernet Switches. The sections in the chapter are.
“Features” on page 13 “Front and Back Panels” on page 16 “Management Software” on page 17 “Twisted Pair Ports” on page 17 “Combo Ports” on page 18 “LEDs” on page 20 “eco-friendly Button” on page 21 “Power Supply” on page 22 “Network Topologies” on page 23

Features

Twisted Pair
Ports
Here are the hardware features of the AT-GS950/8, AT-GS950/16, AT­GS950/24 and AT-GS950/48 Gigabit Ethernet Switches.
8, 16, 24 or 48 ports10Base-TX, 100Base-T and 1000Base-T compliantIEEE 802.3u Auto-Negotiation compliantAuto-MDI/MDIXRJ-45 connectors100 meters (328 feet) maximum operating distanceIEEE 802.3x flow control in 10/100Base-TX full-duplex
operation
IEEE 802.3x back pressure in 10/100Base-TX half-
duplex operation
IEEE803.3z 1000Base-T flow controlSupport for jumbo frames up to 10KB
13
Chapter 1: Overview
Note
Note
SFP Slots Two slots on the AT-GS950/8 and AT-GS950/16
LEDs Speed and link/activity LEDs for the twisted pair ports
Link/activity LEDs for the SFP slotsPower LED
Switches
Four slots on the AT-GS950/24 and AT-GS950/48
Switches
Support 100Base-FX and 1000Base-SX/LX
transceivers
The SFP slots on each switch are paired with twisted pair ports to form combo ports. For more information, refer to “Combo Ports” on page 18.
Installation
Options
Power
Conservation
MAC Address
Table
SFP transceivers must be purchased separately. For a list of supported transceivers, contact your Allied Telesis distributor or reseller.
19-inch equipment rackDesk or tabletopWall
eco-friendly button to turn off the port LEDs when the
system is not being monitored
High-efficiency power supplyPower scaling based on traffic loads on ports operating
at 1000 Mbps (Port power scaling not available at 10 or 100 Mbps)
Power shutdown on unused ports
8 kilobytesAutomatic learning and aging
14
AT-GS950/8, AT-GS950/16, AT-GS950/24 and AT-GS950/48 Switches Installation Guide
Note
Note
Management
Software
AT-S107 Management Software for the AT-GS950/8
Switch
AT-S108 Management Software for the AT-GS950/16
Switch
AT-S109 Management Software for the AT-GS950/24
Switch
AT-S116 Management Software for the AT-GS950/48
Switch
The management software programs come pre-installed on the switches.
Management
Interface
Web-browser interface for in-band, over-the-network
management
Dimensions AT-GS950/8 Switch(W x D x H):
280 mm (11.0 in) x 180 mm (7.1 in) x height - 44 mm (1.7 in)
Operating
Conditions
AT-GS950/16 and AT-GS950/24 Switches (W x D x H):
330 mm (13.0 in) x 200 mm (7.9 in) x 44 mm (1.7 in)
AT-GS950/48 Switch (W x D x H):
440 mm (17.32 in) x 250 mm (9.4 in) x 44 mm (1.7 in)
Operating temperature range of 0° C to 45° C (32° F to
113° F)
Operating humidity range of 5% to 90% non-
condensing
There are two versions of the AT-GS950 Switches. This manual documents the newer version. To determine whether your switch is a old or new version, examine the front panel for the eco-friendly button. The button is found only on the new switches.
15
Chapter 1: Overview
AT-GS950/16
10/100/1000Base-T Twisted Pair Ports
AT-GS950/24
SFP Slots
10/100/1000Base-T Twisted Pair Ports
SFP Slots
AT-GS950/16
10/100/1000Base-T
SFP Slots
Twisted Pair Ports
AT-GS950/8
Port and
System LEDs
Port and
System LEDs
eco-friendly
Button
eco-friendly
Button
Port and
System LEDs
eco-friendly
Button
eco-friendly
Button
10/100/1000Base-T Twisted Pair Ports
AT-GS950/48
SFP Slots
eco-friendly
Button
10/100/1000Base-T Twisted Pair Ports
System LED

Front and Back Panels

Figure 1 on page 16 illustrates the front panels of the AT-GS950/8, AT-GS950/16, AT-GS950/24 and AT-GS950/48 Gigabit Ethernet Switches.
16
Figure 1. AT-GS950/8, AT-GS950/16, AT-GS950/24 and AT-GS950/48