Switches | Product Information
CentreCOM® GS900M Copper Series
Layer 2 Gigabit Access Switches
Allied Telesis CentreCOM GS900M Series copper Gigabit
access switches are cost-effective and fully managed. GS900M
Series switches deliver flexible uplink connectivity with one small
form-factor pluggable (SFP) slot on the 8-port model and 2 or 4
unpopulated combo ports (10/100/1000T or 100FX/1000X) on the
16/24-port models.
Overview
CentreCOM GS900M Series switches
feature quiet operation with a compact,
fanless 8-port model and a variable
fan control feature on the 16/24-port
models. All models feature 0-50°C
extended temperature capability. In
addition, the CentreCOM GS900M
Series includes ECO LED, ECO Trigger,
and Power Saving Mode for energy
efficiency. CentreCOM GS900M Series
switches provide an intelligent, energy
efficient, and cost-effective solution for
the edge of the network.
Key Features
ۼ Web-based graphical user interface for
simplified administration
ۼ Supports up to 50°C extended
temperature
ۼ Eco-friendly
ۼ Flexible LAN authentication functions
ۼ Tri Authentication: Any one physical
port can support a combination of IEEE
802.1X, MAC, and Web Authentication.
Therefore, the user doesn’t have to set
each port configuration based on the
authentication method on the connected
device
ۼ Multiple Dynamic VLAN: The traffic from
a device is classified into a dynamic VLAN
after the connection is authenticated
ۼ IGMP v3 / MLD v2 Snooping: Limits the
flooding of multicast traffic by dynamically
configuring L2 interfaces so that
multicast traffic is forwarded to only those
interfaces associated with IP multicast
address
Specifications
Port Speed
10Mbps/100Mbps/1000Mbps
Port Configuration
Por ts 10/100/100 0T (R J-45
Connector)
AT-GS908M × 8
AT-GS916M × 16
AT-GS 924M × 24
Auto-Negotiation
Auto MDI/MDI-X
MDI/MDI-X Manual Configuration
Full Duplex /Half Duplex Manual Configuration (only on
10/100Mbps mode)
SFP Slots AT-GS908M × 1
AT-GS916M × 2
AT-GS924M × 4
Cable Specifications
10T UTP Category 3 or better
100T UT P Category 5 or bet ter
1000T UTP Enhanced Category 5 or
better
Ethernet Specifications
IEEE 802.3 10BAS E-T
IEEE 802.3u 100 BAS E-TX
IEEE 802.3u 100BA SE-F X
IEEE 802.3ab 1000BASE-T
IEEE 802.3z 1000B ASE-SX /LX
IEEE 802.3ah 100BASE-BX, 1000BASE-BX10
IEEE 802.3x Flow Control
IEEE 802.3ad Link Aggregation Manual Configuration
IEEE 802.1D Spanning-Tree STP Compatible
IEEE 802.1Q VL AN Tagging
IEEE 802.1X Port-Based Network Access Control
IEEE 802.1p Class of Service, priority protoco
l IEEE 802.1s Multiple Spanning-Tree
IEEE 802.1w Rapid Spanning-Tree
LEDs
Selectable Port LED as Speed or Duplex indicator, port LED
can be disabled.
LINK/ACT Green: Link Established
Flashing: S end/Receive Packets
SPD/ DPX (S PEED) Green: 1000Mbps link established
SPD/ DPX (DUPLEX ) Green: Full Duplex link established
SFP Slot LED
LINK/ACT Green: Link Established
Flashing: S end/Receive Packets
Status LED
POWE R Green: Power On
FAULT Red: Detecting Error
Flashing: B ooting, Writing to Flash
Memory, Error on FAN, Voltage, Temp
STANDBY Green: Standby M ode
Supported Features
VLAN (Port-based/lE EE 802.1Q Tagging)
Multiple VLAN
Spanning-Tree (IEEE 802.1 D STP Compatible/ IEE E 802.1 w/
lEEE 802.1s)
QoS (IEEE 802.1p/Diffserv)
Policy-Based QoS
IEEE 802.1x Authentication (Single Host /Multiple Host/
Multiple Authentication)
IEEE 802.1x Encryption Mode (MD5/ TLS/TTL S/PEA P)
Dynamic V LA N
Multiple D ynamic VLAN
MAC Address-based Authentication
Web Authentication
Supplicant MAC Authentication
EPSR-Aware
Port Trunking (lEE E 802.3 ad Manual Configuration)
Port Mirroring
Port Security
Flow Control
Packet Storm Protection
Loop Guard (LD F Detection/Ingress Rate Detection)
Ingress Filtering
HoL Blocking Prevention
IGMP v 3 Snooping
MLD v2 Snooping
BPDU /E AP For warding
DHCP S nooping
Access Filter
DHCP Client
RADIUS Accounting
Jumbo Frame
Logging
Script
SNTP
Statistics
eco-friendly features (Power Saving Mode)
Auto Fan Control
Download firmware and configuration by TF TP/Zmodem/
HTTP
Management
SNMP SNMP v1, SNMP v2c
SNMP MIB MIB II (RFC1213), Ethernet
MIB( RFC 363 5) Ex tended Interface
MIB( RFC 2863 [if X Entr y]) Bridge
MIB(RFC1493)
Dot1q MIB R FC2674, Private MIB
Terminal Telnet, VT100 (via Console), Web GU I
(via HTTP, requires Internet Explorer)
alliedtelesis.com
NETWORK SMARTER
CentreCOM G900M Series | Layer 2 Gigabit Access Switches
Performance
Switching mode
Maximum packet forwarding rate
(entire unit/64 Byte)
1000M <> 1000M 4.0µs 4.2µs 4.0µs
Switching delay (64 Byte)
Switching fabric
Memory
FDB entry
Number of VLANs
100M <> 10 0M 8.8µs 9.3µs 9.0µs
0M <> 10M 57. 3µ s 62.8µs 60.9µs
Packet Buffer 512K B
Flash 16MB
Main Memory 64MB
Power Specifications
Rated input voltage
Rated frequency
Rated input current
Maximum input current
(actual measured value)
Average power consumption
8.6W (M ax 12W) 17W (Max 22W ) 25W (Max 30W )
Environmental Specifications
Operating temperature 0 ºC to 50 ºC (32°F to 122°F)
Storage temperature -20ºC to 60º C (-4°F to 140° F)
Operating humidity 5% to 80% (non-condensing)
Storage humidity 5% to 95% (non-condensing)
Physical Characteristics
Dimensions (W xD x H )
AT-GS908M 26.3 cm × 17.9 cm × 3.8 cm
(10.35 in × 7.05 in × 1.5 in)
AT-GS916M 34.1 cm × 21 cm × 4.4 cm
(13.42 in × 8.26 in × 1.7 in)
AT-GS924M 4 4 cm × 21 cm × 4.4 cm
Weight:
AT-GS908M 1.4 kg (3.08 lbs)
AT-GS916M 2.0 kg (4.41 lbs)
AT-GS924M 2.7 kg (5.95 lbs)
(17.32 in × 8. 26 in × 1.7 in)
Safety and Electromagnetic Emissions
Certifications
EMI AT-GS908M : VCCI Class B
AT-G S916 M
AT-GS924M : VCCI Class A
Safety Standards U L60950-1, CSA-C22.2 No.
60950-1
EU RoH S Compliant
AT-G S90 8M AT-G S916 M AT-G S92 4M
Store and Forward
13.4 Mpps 23.8Mpps 35.7Mpps
24Gbps 36Gbps 48Gbps
8K (Maximum)
256 ( VID=1 ~ 4,094)
AT-G S90 8M AT-G S916 M AT-G S92 4M
100–240V AC
(10% auto-ranging)
50/60Hz
0.3A 0.5A 0.6A
0.2A 0.4A 0.53A
Package Description
AT-GS9XXM switch
120V AC power cord
Management cable (RJ-4 5 to DB-9)
Rack-mount kit for AT-GS916M and AT-GS924M
Install Guide and CL I user’s guide available at
alliedtelesis.com
Ordering Information
GS900M Gigabit Copper Switches
AT-GS 9 08M-xx
8 × 10/100/1000T ports, 1 × SFP slot
1 standard AC power supply in a compact form
factor
AT-GS 916M-xx
14 × 10/100/1000T ports, 2 × Combo ports
(2 × 10/100/1000T or 100FX/1000X ports)
1 standard AC power supply in a compact form
factor
AT-GS 924 M-x x
20 × 10/100/1000T ports, 4 × Combo ports
(4 × 10/100/1000T or 100FX/1000X ports)
1 standard AC power supply in a compact form
factor
Where xx = 10 for US power cord
20 for no power cord
30 for UK power cord
40 for Australian power cord
50 for European power cord
Accessories
AT-R KMT- J 05
19 in rack-mounting kit for AT-GS9 08M
Small Form Pluggable Optics Modules
AT-SP SX
SFP, MMF, 1000Mbps, 220 / 500 m, 850 nm, LC
AT-SP SX-1
SFP, MMF, 1000Mbps, 220 / 550m, 850 nm, LC
Extended temperature: -40ºC to 85ºC
AT-SPEX
SFP, MMF, 1000Mbps, 2 km, 1310 nm, LC
AT-SPL X10
SFP, SMF, 1000Mbps, 10 km, 1310 nm, LC
AT-SPL X10 /I
SFP, SMF, 1000Mbps, 10 km, 1310 nm, LC
Extended temperature: -40ºC to 85ºC
AT-SPL X4 0
SFP, SMF, 1000Mbps, 40 km, 1310 nm, LC
AT-SPZX8 0
SFP, SMF, 1000Mbps, 80 km, 1550 nm, LC
AT-SPBD10-13
SFP, SMF, 1000Mbps, 10 km, 1310/1490 nm,
LC-BiDi
AT-SPBD10-14
SFP, SMF, 1000Mbps, 10 km, 1490/1310 nm,
LC-BiDi
AT-SPFX/2
SFP, MMF, 100Mbps, 2 km, 1310 nm, LC
AT-SPFXBD-LC-13
SFP, SMF, 100Mbps, 10 km, 1310/1510 nm, LCBiDi
AT-SPFXBD-LC-15
SFP, SMF, 100Mbps, 10 km, 1510/1310 nm, LCBiDi
AT-SPFX /15
SFP, SMF, 100Mbps, 15 km, 1310 nm, LC
NETWORK SMARTER
North America Headquarters | 19800 Nor th Creek Parkway | Suite 100 | Bothell | WA 98011 | USA | T: +1 800 424 4284 | F: +1 425 481 3895
Asia-Pacific Headquarters | 11 Tai Seng Link | Singapore | 534182 | T: +65 6383 3832 | F: +65 6383 3830
EMEA & CSA Operations | Incheonweg 7 | 1437 EK Rozenburg | The Netherlands | T: +31 20 7950020 | F: +31 20 7950021
alliedtelesis.com
© 2015 Allied Tele sis, Inc. All right s reserved. Infor mation in this docum ent is subject to chang e without notice. A ll company names, lo gos, and product d esigns that are trad emarks or register ed trademarks are t he property of t heir respective ow ners.
617-00052 7 Rev F