NTPP007, NTPP008, NTPP009
Exaquantum Plant Information Management System
GENERAL
Exaquantum is a Plant Information Management System (PIMS) product that provides business benets to users
in the Hydrocarbons, Chemicals, Power & Utilities, Pulp & Paper and many other industries. The main function of
Exaquantum is the acquisition of data from all facets of a business and the subsequent transformation of that data
into easily usable, high-value, widely-distributed information. The data then becomes an integral part of the set of
tools used by the business in vital decision-making processes.
Exaquantum supports rapid plant-related deployment, making the software easy to implement within plant-specic
operational environments. This allows information to be structured sensibly around the production calendars and
shift patterns in the plant.
Exaquantum is the business intelligent gateway between the operational Process Control System (PCS) and the
business Enterprise Resource Planning (ERP) system. Using the latest, proven, Microsoft based open technology
Exaquantum is designed to provide low administration costs, and be robust to future IT trends.
Exaquantum comprises the following features:
• Process Control Systems Interface
• Data processing and storage
• Role Based View of Exaquantum resources
• Visualization – Exaquantum/Explorer and Web UI
• Multiple server support
• Data exposure via APIs/OLE DB/OPC.
Exaquantum/Web
Web clientWeb clientUser PC
Internet
Intranet
Web Server
OLE DB etc.
External Data:
ERP,
LIMS, etc.
Role Based View
Administration T ools
Real Time Database
PCS Interface
PCS, DCS, PLCs etc
Figure Exaquantum Overview
Exaquantum/Explorer
Local Area Network
Historian
Exaquantum/PIMS (Server)
Exaquantum/PIMS (Server)
OPC Server
User PC
Long-term
Archive
Exaquantum/PIMS (Server)
F01E.ai
KEY FEATURES
Process Control Systems Interface
Exaquantum primarily uses embedded OPC clients to access PCS data with the following OPC servers.
Data Access – OPC DA 2.05a compliant
• Yokogawa Exaopc for CENTUM VP, CS 3000, CENTUM CS, STARDOM and DARWIN.
• Yokogawa Exaopc-RD Redundancy package (*1)
• Yokogawa FAST/TOOLS SCADA
Data Access – OPC UA DA compliant
• SMARTDAC+ (*2)
• OPC UA Server (*3)
Yokogawa Electric Corporation
2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan
• Yokogawa Exaopc for CENTUM VP, CS 3000, CENTUM CS. (*4)
• Yokogawa Exaopc-RD Redundancy package. (*1)
• OPC A&E Servers from other suppliers.
Historical Data Access – OPC HDA 1.1 compliant
• Yokogawa Exaopc for CENTUM VP, CS 3000, CENTUM CS. (*4)
• Yokogawa Exaopc-RD Redundancy package. (*1)
• OPC HDA Servers from other suppliers.
Text Files
Import and export data in Exaquantum-dened ASCII format.
*1: When connecting Exaquantum to Exaopc-RD, please contact your Y okogawa representative.
*2: R3.10 or R3.15, SMARTDAC+ can only be available.
*3: R3.20 supported OPC UA server information, please contact your Yokogawa representative.
*4: CENTUM CS is supported by R3.20 or earlier.
Data Processing and Storage
The Exaquantum Real Time Data Base (RTDB) provides tag-based, real-time process data to be utilized in various
business application software. The data acquired to the RTDB can be optimized through the following functions:
• Quality Codes
Users can judge the validity and reliability of data at a glance. Exaquantum assigns quality codes to data that is
transparent to data users. Quality Codes do not count as licensed tags.
• Aggregations
Basic statistical functions (minimum, maximum, mean, standard deviation, summations, dierential summation and
spot value) are calculated and stored using tag values over pre-dened (hour, day, month or user-dened) time
periods. Aggregations do not count as licensed tags.
• Custom Aggregations
Users can query for aggregations over custom periods using the Exaquantum Excel Add-In or API.
• Function Block
Users can congure relational complex data processing groups as function blocks allowing easy and repeated use
of data.
• KPI Calculations
Users can script simple or complex logic to create raw or aggregated values using calculated tags.
• Exaopc HDA
Following an Exaquantum shutdown period, Exaquantum can access Exaopc’s (R2.10 or later) HDA server to
retrieve missing process data (allowing aggregated and calculated values to also be generated) and Alarms &
Events (A&E). After a LAN interruption, aggregation values can be recalculated Exaquantum can access Exaopc’s
(R3.10 or later) HDA server to retrieve missing process data.
To enable Exaopc History Catch-up functionality, it is necessary to install Exaopc on a separate server to that used
by Exaquantum. The specication of the Exaopc server must be suitable for History Catch-up to perform properly.
2
Exaquantum can also be used as a Data Historian to securely store large amounts of process data and Alarms
& Events. Its powerful and fast storage and retrieval capabilities means there is virtually no limit to the amount of
historical data that can be available online. Automatic archiving and deletion permits older data to be removed from
the system, which can be restored later.
Role Based Name Space (RBNS)
Exaquantum can be congured to provide each user with their own Microsoft Windows group-personalized folder
hierarchy and naming convention view of Exaquantum process data when using the Exaquantum Data Selector within
Exaquantum/Explorer, Exaquantum/Web or the Exaquantum Excel Add-In across all Exaquantum servers.
The Exaquantum administrator controls read and write access to Windows dened user groups. Read-only access
allows process data to be viewed on displays by users. Write access allows users to write data to Exaquantum on a
function block or tag basis.
Multiple Server Support
Multiple Exaquantum servers can seamlessly integrate their process data together to allow visualization on a single
display screen or report. For example, a display screen may consist of a textual tag eld showing data from one
Exaquantum server and a trend showing data from another Exaquantum server.
A Primary and Standby Exaquantum server is designated to contain the Role Based View information accessed by the
users.
If Exaquantum calculation tags require inputs from tags located on other Exaquantum servers then this functionality
(cross server calculations) is available by purchasing the Exaquantum Open Interface (NTPP007).
All Exaquantum servers must contain the same software revision.
Exaquantum provides the following user interfaces.
Exaquantum/Explorer
For users who need to create standard, pre-congured, xed or ad-hoc display screens, the following Exaquantum/
Explorer design tools are available:
• Graphics conguration and runtime support, with components such as Trends, X-Y Plots, Tubular Trends, Data
Entry Grid, Data Write Back, Alarms and Events viewing, Excel Viewer and Web Browser.
• Advanced features such as Report Times, Scripting, Navigation and Data Parameterization.
• Excel Add-In for reporting and analysis of Exaquantum data.
Exaquantum/Explorer can be installed on a CENTUM HIS.
Exaquantum/Web
For people using Microsoft Internet Explorer Web technology deployed on either their PC or tablet and Apple Safari on
tablet devices. In addition, users can select tags from a displayed graphic for displaying on a trend. Exaquantum/Web
supports the following features.
• Plant graphics containing dynamic plant views created with the Exaquantum Web Graphics Editor, add in description
of running ad-hoc trend from graphic or imported and converted Yokogawa DCS graphics.
• Simple to use Trending, with a maximum of 4 graphs per page, featuring:
- Time range selection
- Zoom and Trend Legend
• Users can create ad-hoc Trends which can be saved for subsequent re-use and shared with other users.
• Trends can display Alarms & Events for process data analysis.
• Users can add annotations (notes) to Trends to document plant data.
• Display pre-congured Word, Excel, PDF, etc. reports.
• Excel Add-In for reporting and analysis of Exaquantum data in the Web environment that is compatible with the
Exaquantum/Explorer Excel Add-In.
• X-Y plots for data analysis.
• Trends and X-Y plots can be displayed via a URL.
F02E.ai
Figure: Overlapped Trend with Alarms & Events
Exaquantum Graphic Conversion Tool
This tool converts imported CENTUM VP and CS 3000 graphics into Exaquantum/Explorer and Exaquantum/Web
graphics.
Data Availability via OLE DB
Exaquantum raw, aggregated and calculated values, along with A&E, can provide valuable information to third party
application packages. The Exaquantum OLE DB interfaces can be used to access this information.
These two interfaces allow users to view a snapshot of Exaquantum data using minimal programming.
Data Access through OPC
Application packages can access Exaquantum data via the Exaquantum OPC server, which supports OPC DA 2.05a
and HDA 1.1.
Exaquantum process data and Alarms & Events can be provided to an OSIsoft PI historian using the Exaquantum
OPC Server interface. Tag denition data can be exported from Exaquantum, using Excel or text les to congure the
PI historian. PI must have an equal number of tags to map the Exaquantum data.
Note: The number of tags required for PI is the total of Exaquantum’s instantaneous values and all the aggregation items.
Note: If the PI OPC Open Interface is required, please contact your local Y okogawa representative in advance of implementation
as some conguration is required.
History Data Export (HDE) Tool (R3.20 or later)
The History Data Export (HDE) tool extracts tag data from Exaquantum’s Historian utilizing OPC HDA. The tool can be
run as a command line tool or run displaying a User Interface.
BUSINESS BENEFITS
The business benets of making information available are both diverse, and industry-specic. Some of the typical
benets are described below.
Information Distribution
The availability of large amounts of data available on the desktops and tablets of many users increases eciency.
This increase is a result of fast and easy access to many dierent types of data. RBNS further increases eciency, by
presenting users with just the data that is pertinent to them. When Internet and Intranet access to data is also taken
into account, the benets are even more apparent.
Enhancing PCS Data
Many data sources have limited scope for enhancing their own data. Exaquantum can enhance PCS data with a set of
built-in aggregations. For example, users in some hydrocarbon industries will nd one hour (or shift, daily, etc.) values
(minimum, maximum, mean, summations, equipment run time, etc.) more useful than raw data, especially if totalizers
or accumulators are used for ow measurements. Exaquantum can further enhance the raw and aggregated data with
custom calculations.
Enhancing Data from Multiple PCSs
Exaquantum is able to rene the data from disparate data sources into high-value business information, often known
as Key Performance Indicators (KPIs). For example, tonnage of a product can be calculated from a ow measured by
a PCS and a density measurement provided by a Laboratory Management Information System (LIMS).
Time Resolved Alarm and Event History
Exaquantum can read, historize and display Alarms & Events received from compliant OPC A&E interfaces, which can
be presented in time order for analysis.
For industries where unplanned shutdowns follow a complex series of consequential events, this facility can be very
valuable in identifying the original cause of the shutdown.
An Integrated Platform
The Exaquantum philosophy of open access to data and information enables easy conguration and integration of
application software.
Typical data ows between applications are the passing of:
• Sample results transferred from LIMS to Exaquantum can be used for displays, reports and the calculation of KPIs.
• Inventory and QA data from Exaquantum to an ERP system to optimize planning and scheduling campaigns.
• Condition monitoring data from Exaquantum to maintenance software to automatically initiate repairs and optimize
Planned Maintenance Management schedules.
Long Term History
Long-term historization of plant data by Exaquantum creates the opportunity for further analysis to take place.
Example 1: A system can be set to automatic or manual mode. Analysis of plant history can prove the success of the
Example 2: A LIMS value may indicate a trend leading towards an out-of-spec product. Operators and engineers
Example 3: The ow meter on a main product stream may be inaccurate by several percent indicating leaks or
control settings and monitor their ongoing usage.
have the opportunity to implement a correction before waste products are created.
measurement errors. The measurements from other ow meters on connected streams can be used to
identify an alternative, accurate measurement for the main product stream.
Batch applications can be notied automatically if any steps or changes occur in the process. These changes may
originate from direct process measurements however they can also be the result of Exaquantum aggregations or
calculations. Exaquantum is the standard route for any application that requires event notication from any PCS, thus
minimizing development costs.
IT Security
Legacy and Standard security levels are available allowing compliance with system security requirements.
Microsoft SQL Server 2017 Standard (R3.30 or later)
Exaquantum installation includes Microsoft SQL Server as an Integrated Value Added Solution.
Exaopc Product Security Support (R2.70 or later)
Exaquantum has adopted the same security function as Exaopc R3.70 (*1) which tightens the security for accessing
process control systems (such as CENTUM).
*1: Exaopc (R3.70 or later) can set limits on data access for each user account connecting to Exaopc.
SYSTEM SPECIFICATION
ItemSpecication (*1)
Maximum number of tagsMaximum 500,000 tags (*2)
Throughput of Exaquantum (Maximum data acquisition) 600,000 tags/minute (*3)
Data item gathering interval (minimum)1 second (*4)
Data item data historization interval (minimum)1 second (*4)
Number of concurrent users (Exaquantum/Explorer)Up to 64/server
Number of concurrent users (Exaquantum/Web)Up to 100 for 1 Exaquantum Web Server
Number of connected physical OPC servers per
Exaquantum server
*1: A suitable hardware platform and infrastructure (network) must be chosen to support the required sizing.
*2: Deployed across single or Multi-servers up to a maximum of 500,000 tags.
In case of Multi servers, for a maximum of ve (5) Exaquantum servers.
*3: Select an appropriate number of RAID-5 disks depending on the update rate as illustrated in the examples contained in the
‘Hardware Disk Drive Conguration’ section below.
*4: Depends on the OPC server performance.
*5: Number of connected OPC DA is included in OPC UA DA Server.
*6: The maximum number of supported A&E OPC servers is 31.
The combined total from all connected physical OPC server(s) is not to exceed 130 messages per second.
*7: When using process data from tags from other Exaquantum servers in calculations, then the Exaquantum servers are
included in the number of connected OPC gateways.
Maximum of 35 OPC DA (*5) and HDA servers per Exaquantum Server
(Maximum of 31 OPC A&E servers per Exaquantum Server (*6) (*7))
The minimum requirements for the hardware and software operating environments are described in the tables below.
Please contact the Yokogawa representative for large or non-standard systems requirements.
Exaquantum Server (real-time and historical database)
CPU: Intel x64 architecture as shown below
No. of tagsRequired CPU Specications
Less than 20,000 tagsXeon dual core 2 GHz or higher
20,000 - 50,000 tagsXeon dual core 3 GHz or higher
50,000 - 100,000 tagsXeon 4 core 3 GHz or higher
100,000 - 500,000 tagsXeon 8 core 3 GHz or higher with Hyper-Threading enabled
Note: Please consider the number of Alarm and Event when required CPU Specication is considered. For details, please contact
your Y okogawa representative.
Main memory capacity
No. of tagsOperating SystemMain Memory capacity
Windows Server 2012 Standard 64-bit
Less than 20,000 tags
20,000 tags - 100,000 tags
100,000 tags - 300,000 tags
300,000 tags - 500,000 tags
Windows Server 2012 R2 Standard 64-bit
Windows Server 2016 Standard 64-bit
Windows Server 2019 Standard 64-bit
Windows Server 2012 Standard 64-bit
Windows Server 2012 R2 Standard 64-bit
Windows Server 2016 Standard 64-bit
Windows Server 2019 Standard 64-bit
Windows Server 2012 Standard 64-bit
Windows Server 2012 R2 Standard 64-bit
Windows Server 2016 Standard 64-bit
Windows Server 2019 Standard 64-bit
Windows Server 2012 Standard 64-bit
Windows Server 2012 R2 Standard 64-bit
Windows Server 2016 Standard 64-bit
Windows Server 2019 Standard 64-bit
8 GB or more
10 GB or more
32 GB or more
64 GB or more
6
Note: Please combine the required capacity when another software is to be installed on the Exaquantum.
Disk capacity: Depends on the process data scan rate and retention period.
The disk free space required for installation is:
• System drive: minimum 8 GB (*1)
• SQL server installed drive: minimum 8 GB (*2)
*1: 16 GB or more empty space in main memory is required when a SQL server is installed on a system drive.
*2: 1 TB or more empty space in disk is required when OPC CAMS for HIS or UACS A&E messages are collected and saved.
Hardware disk drive details
ThroughputDetails
Less than 2,000 data/second (*1)Refer to “Example 1: Less than 2,000 updates/second”
2,000 - 5,000 data/secondRefer to “Example 2: 2,000 updates/second to 5,000 updates/second”
5,000 - 10,000 data/secondRefer to “Example 3: 5,000 updates/second to 10,000 updates/second”
CPUEquivalent to Intel Core i3 dual core 1.33 GHz or higher
Main RAM Memory Capacity 4 GB or more
Disk capacity2 GB or more, 3 GB or more (in case of using MS Excel)
Resolution1024 × 768 or better
Display colors65,536 or more
Note: When an Exaquantum client is installed on a HIS, please follow the operational environment specied by the standard
operation and monitoring function (LHS1100, LHM1101, VP6H1 100).
Note: Please combine the required capacity when another software is to be installed on Exaquantum.
Tablet PCs
Apple - iPadWindows - Tablets
Retina resolution2048 × 15362160 ×1440
Non-Retina resolution1024 × 7681920 × 1080, 1366 × 768 or 1024 × 768
Size7 inches or more7 inches or more
Note: As for the Tablet PC, touch panel behavior only is conrmed.
PI OPC Interface PC
CPUEquivalent to Core i3 dual core 2.50 GHz or higher
Main memory2 GB or more
Disk capacityRequires following free space for installation.
System driveMinimum 2 GB required (40 GB recommended)
8
Software Operating Environment
The packages contained in the Software Specication may support either ‘64-bit’ or ‘32-bit’ versions. If either ‘64-bit’ or
‘32-bit’ is not listed then only the 32-bit version is supported.
HardwareSoftware Specication
<Operating System>
•Windows Server 2019 Standard 64-bit (*1)
•Windows Server 2016 Standard 64-bit (*1)
• Windows Server 2012 R2 Standard 64-bit (*1)
Exaquantum Server
Exaquantum Web Server
*1: Exaquantum is a 32-bit application that can be installed with the WOW64 emulation environment provided with the 64-bit
OS.
*2: SQL Server (Main server modules are 64-bit) runtime version is bundled with Exaquantum.
Microsoft SQL Server can only be used by Exaquantum as stated in the SQL Server license certicate.
*3: Supported Editions of Excel 2013 are listed below (Volume License Editions):
• Excel 2013
• Oce Standard 2013
• Oce Professional Plus 2013Supported Editions of Excel 2016 are listed below (V olume License Editions):
• Excel 2016
• Oce Standard 2016
• Oce Professional Plus 2016
• Windows Server 2012 Standard 64-bit (*1)
<Other Software>
• Microsoft SQL Server 2017 Standard 64-bit (*2)
• Microsoft Excel or Oce 2013 (32-bit) / 2016 (32-bit) / 2019 (32-bit / 64-bit) /
Microsoft 365 (32-bit / 64-bit) (*3) (*4)
• Microsoft Internet Explorer 11.0
• Adobe Reader 10.1/11.0/DC (*5)
< Operating System >
• Windows Server 2019 Standard 64-bit (*1)
• Windows Server 2016 Standard 64-bit (*1)
• Windows Server 2012 R2 Standard 64-bit (*1)
• Windows Server 2012 Standard 64-bit (*1)
< Other Software >
Supported Editions of Excel 2019 are listed below(V olume License Editions) :
• Excel 2019
• Oce Standard 2019
• Oce Professional Plus 2019
Supported Editions of Excel 365 are listed below (Click To Run Editions) (C2R):
• Excel 365
• Microsoft Standard 365
As for Microsoft 365 version, refer to the following Yokogawa Web site for the support status.
https://www.yokogawa.com/solutions/products-platforms/solution-based-software/data-historian/data-historian-
exaquantum/#Details_Support-info
*4: There are sometimes compatibility issues, when opening Excel documents created on dierent OS or version of Excel.
There is a workaround for these problems, described in Exaquantum/Explorer User’s Manual Volume 3 - Excel Reports
(IM36J04A12-03E).
*5: Adobe Reader is required to browse Exaquantum R2.50 or later manuals.
HardwareSoftware Specication
<Operating System>
• Windows Server 2019 Standard 64-bit (*1)
• Windows Server 2016 Standard 64-bit (*1)
• Windows Server 2012 R2 Standard 64-bit (*1)
• Windows Server 2012 Standard 64-bit (*1)
• Windows 10 Enterprise 2015 LTSC 64-bit (*1)
User PCs for Exaquantum/
Explorer,
Exaquantum/Web Client (*8)
PI OPC Interface PC (*4)<Operating System> (*4)
T ablet device on W eb Client
(Supported on R3.01 or later)
• Windows 10 Enterprise 2016 LTSC 64-bit (*1)
• Windows 10 Enterprise 2019 LTSC 64-bit (*1)
• Windows 10 IoT Enterprise 2016 L TSC 64-bit (*1)
• Windows 10 IoT Enterprise 2019 L TSC 64-bit (*1)
• Windows 10 Pro SAC 64-bit (*7)
• Windows 10 Enterprise SAC 64-bit (*7)
• Microsoft Excel or Oce 2013 (32-bit) / 2016 (32-bit) / 2019 (32-bit/64-bit) /
Microsoft 365 (32-bit/64-bit) (*2)
• Microsoft Internet Explorer 11.0
• Adobe Reader 10.1/11.0/DC (*3)
<Operating System>
• iOS (From iOS 9 or more can be guaranteed) (*5) (*6)
• Windows 10 Tablet (*5) (*6)
9
LTSC: Long Term Servicing Channel SAC: Semi-Annual Channel
*1: Exaquantum is a 32-bit application that can be installed with the WOW64 emulation environment provided with the 64-bit
OS.
*2: Supported Editions of Excel 2013 are listed below (Volume License Editions):
• Excel 2013
• Oce Standard 2013
• Oce Professional Plus 2013Supported Editions of Excel 2016 are listed below (V olume License Editions):
• Excel 2016
• Oce Standard 2016
• Oce Professional Plus 2016
Supported Editions of Excel 2019 are listed below(V olume License Editions) :
• Excel 2019
• Oce Standard 2019
• Oce Professional Plus 2019
Supported Editions of Excel 365 are listed below (Click To Run Editions): (C2R)
• Excel 365
• Microsoft Standard 365
As for Microsoft 365 version, refer to the following Yokogawa Web site for the support status.
https://www.yokogawa.com/solutions/products-platforms/solution-based-software/data-historian/data-historian-
exaquantum/#Details_Support-info
*3: Adobe Reader is required to browse Exaquantum R2.50 or later manuals.
*4: When PI is used, please contact your Y okogawa representative.
*5: Legacy Exaquantum/Web is not supported.
*6: Exaquantum/Explorer and Excel Add-In are not supported.
*7: The support policy in regard to operating system will depend on the policy of Microsoft.
If any problems occur in the OS during the additional servicing period of OS or after the end of support date, the
service support might be charged by Microsoft and this will be out of scope for maintenance service for Exaquantum
(SV3NTMP001).
Some functions of the Exaquantum/Explore and Exaquantum/Web client may possibly be restricted when Windows Update
is applied to Windows 10 SAC. Refer to the following Y okogawa W eb site for the support status.
https://www.yokogawa.com/solutions/products-platforms/solution-based-software/data-historian/data-historian-
exaquantum/#Details_Support-info
*8: Exaquantum/Web Client does not support Microsoft Edge.
• GS 36J02A10-01E NTPF100 Exaopc OPC Interface Package However , either LHS241 1 or VP6H2411 is used, History Catchup cannot be available.
Note: For detailed information, refer to GS 36J02A10-01E NTPF100 Exaopc OPC interface package. When Exaquantum is
connected to Exaopc-RD, please contact your Y okogawa representative.
Note: The following Revision Numbers are required for Exaquantum to collect Alarms & Events from CAMS.
• Exaopc R3.72 or later
• CENTUM VP R5.03.20 or later
Note: The following Revision Numbers are required for Exaquantum to collect Alarms & Events from UACS
• Exaopc R3.78.10 or later
• CENTUM VP R6.07.10 or later
10
Precaution of connecting with SMARTDAC+
When connecting to SMARTDAC+, ensure to meet the following requirement of SMARTDAC+;
- Firmware version R4.01.03 or later.
- When connecting to SMARTDAC+ by Exaquantum, ordering the SMARTDAC+ which come with E3 option is
required. For more details, please refer to the GS of SMARTDAC+.
Restrictions in Co-existence of Exaquantum and other SBP products
Exaquantum
Server (PIMS or Web servers)T able 1Table1
ClientT able 1T able 2
Note: IT Security model must be set to the ‘Legacy model’ if Exaquantum and other SBP products are installed on a single PC.
SBP products
Co-existence tables for Exaquantum with other SBP products are as shown below:
Table 1:
Exaquantum
(R3.30)
Exaopc
(R3.79) (*2)
OK (*1)OKN/AOKN/A
Exapilot
(R3.98)
Table 2:
Exaopc
(R3.79)
Exaquantum
(R3.30)
OK: Applicable N/A: Not Applicable
OKOKN/AOKOK
Exapilot
(R3.98)
ServerClient
Exaquantum
/Batch
Exaquantum
/Batch
Exaplog
(R3.40) (*3)
Exaplog
(R3.40) (*3)
Platform for Advanced Control
and Estimation
(R5.02.20)
Platform for Advanced Control
and Estimation
(R5.02.20)
Note: Ensure other software operation environments such as OS are valid in addition to the variety of packages and their
revisions.
*1: In the case where the PIMS server and Web server are combined, Exaopc can be also installed.
*2: Exaopc includes Exaopc-RD. Please contact Y okogawa when Exaopc resides with other revisions.
*3: As for another revision, please contact your Y okogawa representative.
(R3.30)
OK: Applicable N/A: Not Applicable
Note: R3.20 IT security model for Exaquantum and other SBP products must be set to the same model when these packages are
installed the same server.
Note: T o ensure the variety of packages, their revisions and other operating environments such as the OS must be identical.
Note: When installing an Exaquantum client on CENTUM CS 3000 HIS, please contact your Y okogawa representative.
*1: On CENTUM VP R4.03 or later, Legacy model or Standard model (Standalone and Domain) can coexist.
ServerN/A
ClientOK (*1)
MODELS AND SUFFIX CODES
Exaquantum/PIMS
An Exaquantum license authorizes tags (data points) up to the number specied by each sux code.
Exaquantum supports a maximum number of 500,000 tags, deployed across single or multiple servers. Only one
DVD set is provided regardless of the number of servers, unless otherwise requested. Every client PC connected to
Exaquantum/PIMS must be licensed. One or more Exaquantum/Explorer Per-Seat Client licenses are provided with
each tag license.
Description
ModelNTPP001Exaquantum Data Server Package
-SBasic Software License
1New Order (with Media)
1English version
This is an optional package for adding additional per-seat users to the NTPP001 package.
Each license will allow an Exaquantum/Explorer client to be installed on a single client PC.
All Exaquantum/Explorer client PCs must be licensed even if Microsoft Terminal Server is used.
This is an optional package for the NTPP001 package. The number of Web servers required should be based upon
the number of concurrent users because more than one Web server may be required to prevent overloading. In the
case of more than 100 Web clients, please use more than one Web Server with a sucient server specication.
Please contact your Yokogawa representative for assistance.
Description
ModelNTPP003Exaquantum Web Server Package
- SBasic Software License
Sux
Codes
1Always 1
1English version
-
Enter number of Web servers required in (01-99)
12
Exaquantum/Web Client (Per-Seat Licensing)
This is an optional package for adding web users, requiring both NTPP001 and NTPP003. Each Exaquantum/Web
client PC or Tablet PC connected to Exaquantum must be licensed. Each license allows an Exaquantum/Web client
to be installed on a single client PC. However, web users are not bound to any one PC and therefore user proles are
used to control access to Exaquantum.
Description
ModelNTPP004Exaquantum Web Client Package
- SBasic Software License
Sux
Codes
1Always 1
1English version
-Enter number of per-seat Web client licenses required in (01-99)
Exaquantum GUI Conversion Tool
This is an optional package that requires the NTPP001 package. It provides conversion of graphics les suitable for
display within Exaquantum/Explorer and Exaquantum/Web screens.
Description
ModelNTPP005Exaquantum GUI Conversion T ool
- SBasic Software License
Sux
Codes
1Always 1
1English version
ECENTUM VP/CENTUM CS 3000 Graphics to Exaquantum/Explorer format
WCENTUM VP/CENTUM CS 3000 Graphics to Exaquantum/Web format
This is an optional package for adding new or additional concurrent users to the NTPP001 package.
Each concurrent license will allow an Exaquantum/Explorer client to be installed on two PCs however only
one Exaquantum/Explorer client can be used at one time. For example, if NTPP006-S11-02 is purchased then
Exaquantum/Explorer can be installed on four PCs where any two of the four PCs can be connected to Exaquantum
at the same time.
All Exaquantum/Explorer client PCs must be licensed even if Microsoft Terminal Server is used.
Description
ModelNTPP006Exaquantum User 2:1 Concurrent Licensing Interface Package
- SBasic Software License
Sux
Codes
1Always 1
1English version
-
Enter new or additional concurrent client licenses in (01-99)
Exaquantum Open Interface
This is an optional package for the NTPP001 package to allow access to Exaquantum process data via OPC DA
2.05a and HDA 1.1. This package is also required for each Exaquantum server providing tag data to Exaquantum
calculated tags located in another Exaquantum server.
Description
ModelNTPP007Exaquantum Open Interface function
- SBasic Software License
Sux
Codes
1Always 1
1English version
-
Enter number of Exaquantum Open Interface function licenses in (01-05)
Additional Exaquantum Server License
This is an optional package to license Exaquantum servers within an Exaquantum multi-server environment.
Description
ModelNTPP008Additional Exaquantum Servers
- SBasic Software License
Sux
Codes
1Always 1
1English version
-
Enter number of new or additional Exaquantum server Licenses in (01-04)
This is an optional for adding additional Exaquantum tags to the NTPP001 package.
Description
ModelNTPP009Exaquantum/PIMS T ags for Upgrade
Sux
Codes
Option
Codes
(*1)
*1: Addition of the number of tags to NTPP001
- SBasic Software License
2For Upgrade of 500,000 or less Exaquantum tags
1English version
/S
/M
/L
/X
Enter number of additional Exaquantum tags in groups of 1,000 until a maximum total of 10,000 tags
are reached.
Enter number of additional Exaquantum tags in groups of 1,000 until a maximum total of 20,000 tags
are reached.
This can only be ordered when the previous tier has been reached.
Enter number of additional Exaquantum tags in groups of 1,000 until a maximum total of 100,000 tags
are reached.
This can only be ordered when the previous tier has been reached.
Enter number of additional Exaquantum tags in groups of 1,000 until a maximum total 500,000 tags are
reached.
This can only be ordered when the previous tier has been reached. (R3.01 or later)
ANNUAL MAINTENANCE CONTRACT
The product is supplied without the manufacturer’s warranty costs. A warranty is obtained by purchasing an Annual
Maintenance Contract (AMC), which covers a specied (contract) time period (usually 1 year). It is mandatory that an
AMC(s) is purchased when a Solution Based Software license products is ordered. The AMC will start on the date that
the license product is delivered to the Yokogawa Sales Oce. You cannot order an optional software product, unless
an active AMC for the existing Solution Based Software license has been purchased.
For more details of the maintenance service, please refer to the “Maintenance Services for Solution-Based Software
/UIEnter number of Exaquantum/Explorer Licenses in (01 - 99).
/UCEnter number of Exaquantum/Explorer 2:1 Concurrent Licenses in (01 - 99).
/WSEnter number of Exaquantum Web server in (01 - 99).
/WCEnter the number of Exaquantum/Web server named user Licenses in (01 - 99).
/GEExaquantum GUI Conversion Tool (Exaquantum/Explorer format).
/GWExaquantum GUI Conversion Tool (Exaquantum/Web format).
/OPEnter number of Exaquantum Open Interface in (01- 05).
/MLEnter number of Exaquantum multi-server Licenses in (01 - 04).
Enter number of additional Exaquantum tags in groups of 1,000 until a maximum total of 10,000 tags
are reached.
Enter number of additional Exaquantum tags in groups of 1,000 until a maximum total of 20,000 tags
are reached.
This can only be ordered when the previous tier has been reached.
Enter number of additional Exaquantum tags in groups of 1,000 until a maximum total of 100,000 tags
are reached.
This can only be ordered when the previous tier has been reached.
Enter number of additional Exaquantum tags in groups of 1,000 until a maximum total of 500,000 tags
are reached.
This can only be ordered when the previous tier has been reached.
15
Description
TRADEMARK ACKNOWLEDGMENT
The names of corporations, organizations, products and logos herein are either registered trademarks or trademarks
of Yokogawa Electric Corporation and their respective holders.