Yokogawa MY40-01 Data sheet

MY40 Digital Insulation Tester
Digital model with 4 voltage/resistance ratings
Multifunction
Insulation resistance, AC voltage and conductor resistance measurement Insulation test mode: Comparator, memory, auto-hold and
All test modes: Live-line alarm (excluding AC voltage
Double-action safety mechanism
Testing Performance Specifications
Model Rating
125V/200M
250V/200M
MY40
-01
500V/2000M
1000V/2000M
Range Option
.4000
4.000
40.00
200.0 .4000
4.000
40.00
200.0
4.000
40.00
400.0 2000
4.000
40.00
400.0 2000
Measuring Range Tolerance
Resolution
.1k
1k
10k
0–.0199M
.0200–10.00M
10.01–200.0M
100k
.1k
1k
10k
0–.0499M
.0500–20.00M
20.01–200.0M
100k
1k
10k
100k
0–0.999M
1.000–500M 501–2000M
1M
1k
10k
100k
0–1.999M
2.000–1000M 1001–2000M
1M
± (5%of rdg+6dgt)
*
± (2%of rdg+6dgt) ± 5%of rdg
± (5%of rdg+6dgt)
*
± (2%of rdg+6dgt) ± 5%of rdg
± (5%of rdg+6dgt)
*
± (2%of rdg+6dgt) ± 5%of rdg
± (5%of rdg+6dgt)
*
± (2%of rdg+6dgt) ± 5%of rdg
Lower Limit of
measured
0.125M
0.25M
0.5M
2M
Current
0.5mA
* First effective measuring range; ** The minimum value at which the rated voltage can be maintained
Rated
1mA
1mA
1mA
Central Scale
Standard test conditions
Ambient temperature/humidity ranges: 23 ±5:/45-75% RH
Value
Tolerances under the above-mentioned conditions:
5M
Deviation from zero scale value: 6 digits maximum
Indication of mark on bar graph: Approx. 4000 M min. (500 V/1000 V)
Open circuit voltage: 130% max. of rated voltage
5M
Rated measuring current: Short-circuit Current: 2 mA max.
50M
AC voltage measurement (45-400 Hz)
MY40-01 600V 1V ±(2% of rdg + 6dgt) Approx. 2 M
50M
Conductor resistance measurement
MY40-01 4000.1Ω ±(2% of rdg + 8dgt)
SERIES
discharge functions
measurement), battery check and automatic power-off
Protection against inad­vertent setting of rotary switch to 1000 V rating
Approx. 400 M min. (125 V/250 V)
1 mA (0 to 20%) when in first effective measuring range
Model Range
Model Range
Resolution
Resolution
Accuracy Input Impedance
Accuracy
Open-circuit Voltage
Buzzer sound resistance: <40.
General Specifications
Display: 3 1/2-digit LCD; 4000 count; backlight-illuminated; logarithmic bar graph; extension bar graph–no fluctuations, as the display shows the digits of a reading in the order in which each digit settles.
Example of Extension Bar Indicator View
The data value is changing.
The data value is fixed.
Comparator function:The MY40 alerts you by turning on the LOW symbol and sounding the buzzer if the measured value is smaller than the reference value. You can allocate as many as three user-defined reference values to each rating. The factory-set defaults are 0.1 MΩ,
0.2 M and 0.4 M.
Memory function:For each rating, you can save as many as 20 meas­urements at desired memory address numbers.
Automatic discharge function:The MY40 automatically begins dis­charge when you turn off the MEAS switch. You can monitor the state of discharge by checking the bar graph and make sure discharge is complete by checking that the segment bar disappear.
High-voltage indicators: The high-voltage symbol and LED lamp come on to alert you when the MY40 is in insulation testing mode or if any voltage remains to be discharged.
Live-line alarm:If you apply an AC voltage of approximately 40 V or higher across the input terminals, the MY40 alerts you by blinking the LED lamp and sounding the buzzer.
Overrange input alarm: If the voltage being measured exceeds 600 V during AC voltage measurement, the MY40 alerts you by flashing the Maximum Value indicator and sounding the buzzer.
Auto-hold function: The tester retains the measured resistance for approximately 5 seconds after the MEAS switch is turned off.
Dimensions: 125 (W) ҂ 103 (H) ҂ 53 (D) (mm), excluding protrusions
Weight: 420 g (main unit and batteries only, excluding accessories)
Batteries: Four AA (R6P) batteries
Note: See the list of accessories on the backside of this bulletin for more information on accessories.
Standard Accessories
Product Part Number Qty
Protection cover
Shoulder strap
Line probe
Earth probe
User's manual
Batteries
93013
99005
98001
98002
1
1
1
1
1
4
External Dimensions Unit: mm
52.5
103
93015
Carrying case
(case for housing both the main
unit and accessories)
93013
Protection cover
LIGHT
Enter
INSULATION
TESTER
MEM
MEAS
PULL
LOCK
COMP
Select
125
ALARM
1000V
2000M
500V
250V
200M
125V
V
600V MAX
OFF
1000V RELEASE
Clr
B9108XA
Accessory-housing case
3
Loading...