Yokogawa ISC40 User Manual

User’s
Model ISC40G(S)
Manual
Sensors and Fittings for Inductive
Conductivity Measurement
IM 12D8J2-E-E
16th edition
(BG)
Всички улътвания за продукти от серията ATEX Ex ce лредлагат на английски език. Ако се нуждаете oт улътвания за продукти oт серията Ex на родния ви eзик, ce свържете c най-близкия oфис или представителство на фирма Yokogawa.
(CZ)
Všechny uživatelské příručky pro výrobky, na něž se vztahuje nevýbušné schváleni ATEX Ex, jsou dostupné v angličtině. Požadujete-li pokyny týkající se výrobků s nevýbušným schválením ve vašem lokálním jazyku, kontaktujte prosím vaši nejbližší reprezentačni kancelář Yokogawa.
(D)
Alle Betriebsanleitungen für ATEX Ex bezogene Produkte stehen in den Sprachen Englisch. Sollten Sie die Betriebs- anleitungen für Ex-Produkte in Ihrer Landessprache benötigen, setzen Sie sich bitte mit Ihrem örtlichem Yokogawa-Vertreter in Verbindung.
(DK)
Alle brugervejledninger for produkter relateret til CE er tilgængelige på engelsk. Skulle De ønske yderligere oplysninger om håndtering af CE produkter på eget sprog, kan De rette henvendelse herom til den nærmeste Yokogawa afdeling eller forhandler.
(E)
Todos los manuales de instrucciones para los productos antiexplosivos de ATEX están disponibles en inglés. Si desea solicitar las instrucciones de estos artículos antiexplosivos en su idioma local, deberá ponerse en contacto con la ocina o el representante de Yokogawa más cercano.
(F)
Tous les manuels d’instruction des produits ATEX Ex sont disponibles en langue anglaise. Si vous nécessitez des instructions relatives aux produits Ex dans votre langue, veuillez bien contacter votre représentant Yokogawa le plus proche.
(GB)
All instruction manuals for ATEX Ex related products are available in English. Should you require Ex related instructions in your local language, you are to contact your nearest Yokogawa ofce or representative.
(GR)
Ολα τα εγχειριδια λειτουργιας των προιοντων με ATEX Ex διατιθενται στα Αγγλικα. Σε περιπτωση πον χρειαζεοτε οδηγιεξ σχετικα με Ex στην τοπικη γλωσσα παρακαλονμε επικοινωνηστε με το πλησιεστερο γραφειο τηζ Yokogawa η αντιπροσωπο τηξ.
(EST) Kõik ATEX Ex toodete kasutamisjuhendid on esitatud inglise keeles. Ex seadmete muukeelse dokumentatsiooni saamiseks pöörduge lähima lokagava (Yokogawa) kontori või esindaja poole.
IM 12D8J2-E-E
(H)
Az ATEX Ex mûszerek gépkönyveit angol nyelven adjuk ki. Amennyiben helyi nyelven kérik az Ex eszközök leírásait, kérjük keressék fel a legközelebbi Yokogawa irodát, vagy képviseletet.
(I) Tutti i manuali operativi di prodotti ATEX contrassegnati con Ex sono disponibili in inglese. Se si desidera ricevere i manuali operativi di prodotti Ex in lingua locale, mettersi in contatto con l’ufcio Yokogawa più vicino o con un rappresentante.
(LV)
Visas ATEX Ex kategorijas izstrâdâjumu Lietoðanas instrukcijas tiek piegâdâtas angïu valodâs. Ja vçlaties saòemt Ex ierîèu dokumentâciju citâ valodâ, Jums ir jâsazinâs ar rmas Jokogava (Yokogawa) tuvâko osu vai pârstâvi.
(LT) Visos gaminiø ATEX Ex kategorijos Eksploatavimo instrukcijos teikiami anglø kalbomis. Norëdami gauti priestaisø Ex dokumentacijà kitomis kalbomis susisiekite su artimiausiu bendrovës Yokogawa biuru arba atstovu.
(M)
Il-manwali kollha ta’ l-istruzzjonijiet għal prodotti marbuta ma’ ATEX Ex huma disponibbli bl-Ingliż. Jekk tkun teħtieģ struzzjonijiet marbuta ma’ Ex l-lingwa lokali tiegħek, għandek tikkuntattja lill-eqreb rappreżentan jew ufććju ta’ Yokogawa.
(NL) Alle handleidingen voor producten die te maken hebben met ATEX explosiebeveiliging (Ex) zijn verkrijgbaar in het Engels. Neem, indien u aanwijzingen op het gebied van explosiebeveiliging nodig hebt in uw eigen taal, contact op met de dichtstbijzijnde vestiging van Yokogawa of met een vertegenwoordiger.
(P) Todos os manuals de instruções referentes aos produtos Ex da ATEX estão disponíveis em Inglês. Se necessitar de instruções na sua língua relacionadas com produtos Ex, deverá entrar em contacto com a delegação mais próxima ou com um representante da Yokogawa.
(PL) Wszystkie instrukcje obsługi dla urządzeń w wykonaniu przeciwwybuchowym Ex, zgodnych z wymaganiami ATEX, dostępne są w języku angielskim. Jeżeli wymagana jest instrukcja obsługi w Państwa lokalnym ję zyku, prosimy o kontakt z najbliższym biurem Yokogawy.
(RO)
Toate manualele de instructiuni pentru produsele ATEX Ex sunt in limba engleza. In cazul in care doriti instructiunile in limba locala, trebuie sa contactati cel mai apropiat birou sau reprezentant Yokogawa.
(S) Alla instruktionsböcker för ATEX Ex (explosionssäkra) produkter är tillgängliga på engelska. Om Ni behöver instruktioner för dessa explosionssäkra produkter på annat språk, skall Ni kontakta närmaste Yokogawakontor eller representant.
(SF) Kaikkien ATEX Ex-tyyppisten tuotteiden käyttöhjeet ovat saatavilla englannin-. Mikäli tarvitsette Ex-tyyppisten tuotteiden ohjeita omalla paikallisella kielellännne, ottakaa yhteyttä lähimpään Yokogawa-toimistoon tai
-edustajaan.
(SK) Všetky návody na obsluhu pre prístroje s ATEX Ex sú k dispozícii v jazyku anglickom. V prípade potreby návodu pre Ex-prístroje vo Vašom národnom jazyku, skontaktujte prosím miestnu kanceláriu rmy Yokogawa.
(SLO) Vsi predpisi in navodila za AEX Ex sorodni pridelki so pri roki v anglišèini. Èe so Ex sorodna navodila potrebna v vašem tukejnjem jeziku, kontaktirajte vaš najbliši Yokogawa ofce ili predstaunika.
IM 12D8J2-E-E
Contents
1 INTRODUCTION 7
1.1 General 7
1.2 Unpacking and Checking 7
1.3 Warranty and Service 7
1.4 Serial Number definition 8
2 GENERAL SPECIFICATIONS 9
2.1 Measuring elements 9
2.2 Materials 9
2.3 Functional specifications (at 25°C) 9
2.4 Dynamic specifications 9
2.5 Operating range 10
2.6 Regulatory standards 10
2.7 Shipping details 11
2.8 Environmental conditions 11
2.9 Process connections 11
3 INSTALLATION OF SENSOR WITH STANDARD OPTIONS 14
3.1 Typical installation 14
3.1.1 Installation of ISC40G(S)-GG (TG) with flange adapters 14
3.1.2 Installation of ISC40G(S)-TG with T-piece 16
3.1.3 Installation of ISC40G(S)-GS with flange adapters 17
4 DIMENSIONS ISC40 SENSOR 18
5 WIRING ISC40 SENSOR 19
6 MODELCODE ISC40 SENSOR 20
7 SPAREPARTS ISC40 SENSOR 21
8 EU DECLARATION OF CONFORMITY 22
9 ISC40FS – FLOW FITTING SUBASSEMBLY 24
9.1 General Specifications 24
9.1.1 Materials 24
9.1.2 Operating range 24
9.1.3 Shipping details 24
9.1.4 Process connections 24
9.2 Installation of ISC40 sensor in ISC40FS 24
9.3 Dimensions ISC40FS 25
9.4 Modelcode ISC40FS 26
9.5 Spareparts ISC40FS 26
IM 12D8J2-E-E
10 ISC40FF – FLOW FITTING 27
10.1 General Specifications 27
10.1.1 Materials 27
10.1.2 Operating range 27
10.1.3 Shipping details 27
10.1.4 Process connections 27
10.2 Installation of ISC40 sensor in ISC40FF 27
10.3 Dimensions ISC40FF 28
10.4 Modelcode ISC40FF 29
10.5 Spareparts ISC40FF 30
11 ISC40FD – IMMERSION FITTING 31
11.1 General Specifications 31
11.1.1 Materials 31
11.1.2 Operating range 31
11.1.3 Process connections 31
11.2 Installation of ISC40 sensor in ISC40FD 31
11.3 Dimensions ISC40FD 33
11.4 Modelcode ISC40FD 34
11.5 Spareparts ISC40FD 34
12 Chemical Compatibility Chart 35
IM 12D8J2-E-E
IM 12D8J2-E-E
1 INTRODUCTION
1.1 General
The sensor and fitting program for inductive conductivity measurement (model ISC40) is designed to meet the most common installation requirements in terms of material compatibility, process connections and flow dynamics. The various installation possibilities are described and illustrated in this manual. The following categories of installation can be recognised:
1. Direct mounting of sensors in tank wall or customer supplied flanges
2. Cost effective installation of sensors using process adapters
3. Maintenance friendly installation of sensors using in-line subassemblies
4. Installation in flow chambers for measurements in sample streams or bypass loops
5. Installation in immersion fittings for measurement in open tanks or channels
Within the wide range of process adapters, subassemblies, flow fittings and immersion fittings it is easy to find the appropriate installation that fits the application (a wide choice of materials), the plant installation practice (a wide choice of process con­nections) and the maintenance procedures.
1.2 Unpacking and Checking
Upon delivery, unpack the sensor carefully and inspect it to ensure that it is not damaged during shipment. If damage is found, retain the original packing material and immediately notify the carrier and the relevant local Yokogawa Sales office. Make sure the Model Code and Serial Number on the sensor are the same as on the packing list. Also check if option(s) that were ordered, are included and correct.
1.3 Warranty and Service
Yokogawa products are guaranteed free from defects in workmanship and materials under normal use and service for a period of (typically) 12 months from the date of shipment from the manufacturer. Individual Sales organizations can deviate from the typical warranty period, and the conditions of sale relating to the original purchase order should be consulted. Damage caused by wear and tear, inadequate maintenance, corrosion, or by the effects of chemical processes is excluded from this warranty coverage. In the event of a warranty claim, the defective goods should be sent (freight paid) to the Service Department of the relevant Yokogawa Sales office for repair or replacement (at Yokogawa’s discretion).
The following information must be included in the letter accompanying the returned goods:
• Model Code and Serial Number.
• Original Purchase Order and Date.
• Length of time in service and description
of the process.
• Description of the fault and circumstances
of the failure.
• Process/environmental conditions that
may be related to the failure of the sensor.
• Statement as to whether warranty or non-
warranty service is requested.
• Complete shipping and billing instructions
for return of material, plus the name and phone number of a contact person that can be reached for further information.
• Clean Statement Returned goods that have been in contact with process fluids must be decontaminated and disinfected prior to shipment. Goods should carry a certificate to this effect, for the health and safety of our employees. Material Safety Data sheets must be included for all components of the process to which the sensor(options) have been exposed.
IM 12D8J2-E-E
1.4 Serial Number definition
The Serial Number is defined by nine (9) alphanumeric characters: X1X2 Production Location X3X4 Year/Month code X5X6 X7X8 X9 Tracking number
Example: N1B600028
Table 1:
Production year according to DIN. IEC 60062
Year Yearcode Year Yearcode
2012 C 2024 S 2013 D 2025 T 2014 E 2026 U 2015 F 2027 V 2016 H 2028 W 2017 J 2029 X 2018 K 2030 A
2019 L 2031 B
2020 M 2032 C 2021 N 2033 D 2022 P 2034 E 2023 R 2035 F
Table 2:
Production month code according to DIN. IEC 60062
Month Monthcode
January 1 February 2 March 3 April 4 May 5 June 6 July 7 August 8 September 9 October O November N December D
IM 12D8J2-E-E
2 GENERAL SPECIFICATIONS
The ISC40 inductive conductivity sensor is suitable for use with the Yokogawa inductive conductivity analyzers.
2.1 Measuring elements
: Toroïds with high permeability magnetic material
Pt1000 or 30k temperature element
2.2 Materials Wetted parts sensor
Body ISC40*-G* : 30% glass filled PEEK, FDA approved Body ISC40*-T* : PFA, FDA approved Non-wetted parts sensor Sealing gasket : Viton Thread part : AISI 316 SS Options for sensor
All options except /TFD : AISI 316 SS and O-ring material as wetted part /TFD : AISI 316 SS as non-wetted part
TFM and Kalrez as wetted part
2.3 Functional specifications (at 25°C)
Temperature element : Pt1000 to IEC 751
30k NTC
Installation factor : 1.88 cm-1 nominal for PEEK sensor
3.00 cm-1 nominal for PFA sensor Actual installation can change this factor. If there is less than 25mm spacing between sensor and holder, in-situ calibration is necessary to meet the specified accuracies (see fig. 1)
Only for PEEK
1.30
1.25
1.20
1.15
non conductive
1.10
1,05
1.00
0.95
Correction factor (x nominal C.C.)
0.90
piping
conductive
piping
0 10 20 30 40 50
D
D in millimeters
Fig 1: Actual installation factor as function of spacing around the sensor
Note: The ISC40 temperature sensor is designed for cell compensation and for indication.
It is NOT designed for process temperature control.
2.4 Dynamic specifications
Response time : t90 < 5 min. for PEEK sensor conductivity : t90 < 10 min. for PFA sensor
IM 12D8J2-E-E
10
2.5 Operating range
Conductivity : 0 – 2000 mS/cm at actual process temperature.
Note: The sensor has an error (0.5 µS/cm for PEEK model, 1.0 µS/cm for PFA model) that
must be considered when application is chosen.
Temperature : -20°C to 130°C (-4°F to 266°F) for PEEK sensor
-20°C to 100°C (-4°F to 212°F) for PFA sensor
Pressure : 0 to 20 bar (0 to 290 PSIG) for PEEK sensor
0 to 10 bar (0 to 145 PSIG) for PFA sensor.
Note: At maximum process temperature the maximum pressure for the PFA sensor is 5 bar
(72 PSIG).
Cable length : max 50 meter, in combination with WF10 extension cable and
BA10 junction box
2.6 Regulatory standards CE : Decision 768/2008/EC
- ATEX : Directive 94/9/EC, as amended by Regulation (EC) no. 1882/2003
Certificate no. : DEKRA 11ATEX0063 X
II 1 G Ex ia IIC T4…T6 Ga
Electrical data : Sensor output circuits (permanently connected cable)
connected to a certified intrinsically safe circuit with the following maximum values: Ui = 19.1 V; Ii = 170 mA; Pi = 0.8 W; Ci = 0 nF; Li = 0 mH or certified intrinsically safe Yokogawa Inductive Conductivity
transmitter model FLXA21 series, model ISC202S series or
model IC200S series
Note: The effective internal capacitance Ci and the effective internal inductance Li of the
sensor are depending only upon the properties and the length of the connected cable.
Special conditions (X) : T6 for Tamb. -30°C to 40°C
T5 for Tamb. -30°C to 95°C T4 for Tamb. -30°C to 130°C, depending on sensor body material
: The sensor must be installed and used so, that dangers
of ignition due to hazardous electrostatic charges cannot occur, especially in the case that the process medium is non­conductive.
- Pressure : Directive 97/23/EC, as amended by Regulation (EC) no. 1882/2003
Applying article : 3.3 (Sound Engineering Practice)
IECEx
Applying standards : IEC 60079-0 : 2007
IEC 60079-11 : 2006 IEC 60079-26: 2006
Certificate no. : IECEx DEK 11.0028X
Ex ia IIC T4…T6 Ga
IM 12D8J2-E-E
CSA
Certificate no. : 2447837 IS, Class I Div. 1, GP A, B, C, D T4…T6
Master Contract no 182892
Electrical data : Sensor output circuits (permanently connected cable)
connected to a certified intrinsically safe circuit with the following maximum values: Uo = 19.1 V; Io = 170 mA; Po = 0.8 W; Co≥ Ci + Ccable; Lo≥ Li + Lcable or certified intrinsically safe Yokogawa Inductive Conductivity
transmitter model FLXA21 series, model ISC202S series or
model IC200S series Ambient : T6 for Tamb. -30°C to 40°C temperature range T5 for Tamb. -30°C to 95°C
T4 for Tamb. -30°C to 130°C, depending on sensor body
material
Note: Intrinsically safe when connected as per Control Drawing FF1-K1244QY (see fig. 2)
FM
Certificate no. : 3046320 IS, Class I, Div. 1, Groups A, B, C, D T4…T6 Electrical data : Sensor output circuits (permanently connected cable)
connected to a FM approved intrinsically safe apparatus
meeting the entity parameters of the ISC40S:
Uo≤ 19.1 V; Io≤ 170 mA; Po≤ 0.8 W;
Co≥ Ci + Ccable; Lo≥ Li + Lcable
or
certified intrinsically safe Yokogawa Inductive Conductivity
transmitter model FLXA21 series, model ISC202S series or
model IC200S series Ambient : T6 for Tamb. -30°C to 40°C temperature range T5 for Tamb. -30°C to 85°C
T4 for Tamb. -30°C to 85°C, depending on sensor body
material Note: Intrinsically safe when connected as per Control Drawing FF1-K1244QX (see fig. 3)
11
2.7 Shipping details Package size (LxWxH)
ISC40*-**-*-03 (05) : 350 x 270 x 50 mm (13.8 x10.6 x 2.0 inch) ISC40*-**-*-10 (15, 20) : 320 x 240 x110 mm (12.6 x 9.5 x 4.3 inch) Package weight (app.) ISC40*-**-*-03 : 1.0 kg (2.2 lbs) ISC40*-**-*-05 : 1.3 kg (2.9 lbs) ISC40*-**-*-10 : 1.6 kg (3.5 lbs) ISC40*-**-*-15 : 2.1 kg (4.6 lbs) ISC40*-**-*-20 : 2.5 kg (5.5 lbs)
2.8 Environmental conditions
Storage temperature : -30°C to 50°C (-22°F to 122°F) Water proof : IP67 (conform IEC 60529), also in combination with the
preferred Yokogawa process connections
2.9 Process connections
Process connections are made in combination with a variety of adapters and fittings,
which are available in AISI 316 SS, PVC or PVDF (see relevant sections in this manual).