Yaesu FT950 User Manual

FT-950
Technical supplement
2007 VERTEX STANDARD CO., LTD.
©
EH031H90A

Introduction

This manual provides technical information neces­sary for servicing the FT-950 HF/50 MHz Trans­ceiver. Servicing this equipment requires expertise in han­dling surface-mount chip components. Attempts by non-qualified persons to service this equipment may result in permanent damage not covered by the warranty, and may be illegal in some countries. Two PCB layout diagrams are provided for each double-sided circuit board in the Transceiver. Each side of is referred to by the type of the majority of components installed on that side (“leaded” or “chip­only”). In most cases one side has only chip com­ponents, and the other has either a mixture of both chip and leaded components (trimmers, coils, elec­trolytic capacitors, ICs, etc.), or leaded components only. While we believe the technical information in this manual to be correct, VERTEX STANDARD as­sumes no liability for damage that may occur as a result of typographical or other errors that may be present. Your cooperation in pointing out any in­consistencies in the technical information would be appreciated.
VERTEX STANDARD CO., LTD.
4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan
VERTEX STANDARD
US Headquarters
10900 Walker Street, Cypress, CA 90630, U.S.A.
YAESU EUROPE B.V.
P.O. Box 75525, 1118 ZN Schiphol, The Netherlands
YAESU UK LTD.
Unit 12, Sun Valley Business Park, Winnall Close Winchester, Hampshire, SO23 0LB, U.K.
VERTEX STANDARD HK LTD.
Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road, Kwun Tong, Kowloon, Hong Kong
VERTEX STANDARD (AUSTRALIA) PTY., LTD.
Normanby Business Park, Unit 14/45 Normanby Road Notting Hill 3168, Victoria, Australia

Contents

Introduction
Specifications
Exploded View
Block Diagram
Connection Diagram
WIRE ASSY List
Board Unit (Schematics, Layouts & Parts)
MAIN Unit
CNTL Unit
LOCAL Unit
PA-A Unit
TUNER Unit
DSP Unit
SW-A Unit
SW-B Unit
VR-A Unit
VR-B Unit
PHONE Unit
MIC Unit
KEY Unit
DVS-6 Unit (Option)
Important Note
This transceiver was assembled using Pb (lead) free solder, based on the RoHS specification. Only lead-free solder (Alloy Composition: Sn-3.0Ag-0.5Cu) should be used for repairs performed on this apparatus. The solder stated above utilizes the alloy composition required for compliance with the lead-free specification, and any solder with the above alloy composition may be used.
FT-950 Technical Supplement
Specifications-1

Specifications

General
Rx Frequency Range: 30 kHz - 56 MHz (operating)
160 - 6 m (specified performance, Amateur bands only)
Tx Frequency Ranges: 160 - 6 m (Amateur bands only) Frequency Stability: ±0.5 ppm (after 1 minute @+77 °F [+25 °C])
±1.0 ppm (after 1 minute @+14 °F ~ +122 °F [-10 °C ~ +50 °C])
Operating Temperature Range: 14 °F ~ +122 °F (-10 °C ~ +50 °C) Emission Modes: A1A (CW), A3E (AM), J3E (LSB, USB), F3E (FM),
F1B (RTTY), F1D (PACKET), F2D (PACKET)
Frequency Steps: 1/10 Hz (SSB, CW, & AM), 100 Hz (FM) Antenna Impedance: 50 Ohms, unbalanced
16.7 - 150 Ohms, unbalanced (Tuner ON, 160 - 6 m Amateur bands, TX only)
Power Consumption (Approx.): Rx (no signal) 1.8 A
Rx (signal present) 2.1 A Tx (100 W) 22 A
Supply Voltage: DC 13.8 V ± 10% (Negative Ground) Dimensions (WxHxD): 14.4" x 4.5" x 12.4" (365 x 115 x 315 mm) Weight (Approx.): 21.6 lbs (9.8 kg)
Transmitter
Power Output: 5 - 100 watts (2 - 25 watts AM carrier) Modulation Types: J3E (SSB): Balanced,
A3E (AM): Low-Level (Early Stage), F3E (FM): Variable Reactance
Maximum FM Deviation: ±5.0 kHz/±2.5 kHz Harmonic Radiation: Better than -60 dB (160 - 10m Amateur bands: Harmonics)
Better than -50 dB (160 - 10m Amateur bands: Others) Better than -65 dB (6m Amateur band)
SSB Carrier Suppression: At least 60 dB below peak output Undesired Sideband Suppression: At least 60 dB below peak output 3rd-order IMD: -31 dB @14 MHz 100 watts PEP Bandwidth: 3 kHz (LSB/USB), 500 Hz (CW), 6 kHz (AM), 16 kHz (FM) Audio Response (SSB): Not more than -6 dB from 300 to 2700 Hz Microphone Impedance: 600 Ohms (200 to 10 kOhms)
Specifications-2
FT-950 Technical Supplement
Specifications
Receiver
Circuit Type: Triple-conversion Superheterodyne Intermediate Frequencies: 69.450 MHz/450 kHz/30 kHz (24 kHz for AM/FM) Sensitivity: SSB (BW: 2.4 kHz, 10 dB S+N/N)
4 µV (0.5 - 1.8 MHz) (IPO "ON")
0.2 µV (1.8 - 30 MHz) (AMP 2 "ON")
0.125 µV (50 - 54 MHz) (AMP 2 "ON")
AM (BW: 6 kHz, 10 dB S+N/N, 30 % modulation @400 Hz)
28 µV (0.5 - 1.8 MHz) (IPO "ON") 2 µV (1.8 - 30 MHz) (AMP 2 "ON") 1 µV (50 - 54 MHz) (AMP 2 "ON")
FM (BW: 15 kHz, 12 dB SINAD)
0.5 µV (28 - 30 MHz) (AMP 2 "ON")
0.35 µV (50 - 54 MHz) (AMP 2 "ON")
There is no specification for frequency ranges not listed.
Squelch Sensitivity: SSB/CW/AM
2 µV (0.1 - 1.8 MHz) 2 µV (50 - 54 MHz)
FM
1 µV (28 - 30 MHz) 1 µV (50 - 54 MHz)
There is no specification for frequency ranges not listed.
Selectivity (WIDTH: Center): Mode -6 dB -60 dB
CW/RTTY/PKT 0.5 kHz or better 750 Hz or less SSB 2.4 kHz or better 3.6 kHz or less AM 6 kHz or better 15 kHz or less FM 15 kHz or better 25 kHz or less
Image Rejection: 70 dB or better (160 - 10m Amateur bands)
60 dB or better (6m Amateur band)
Maximum Audio Output: 2.5 W into 4 Ohms with 10% THD Audio Output Impedance: 4 to 8 Ohms (4 Ohms: nominal) Conducted Radiation: Less than 4 nW
Specifications are subject to change, in the interest of technical improvement, without notice or obligation, and are guaranteed only within the amateur bands.
FT-950 Technical Supplement
Specifications-3
Specifications
Note
Specifications-4
FT-950 Technical Supplement

Exploded View

REF. VXSTD P/N Description Qty.
U31406007 OVAL HEAD SCREW M4X6B 6
U20308007 BINDING HEAD SCREW M3X8B 5
U24305007 BIND HEAD TAPTITE-B M3X5B 4
U31410020 OVAL HEAD SCREW M4X10SUS 2
U31306007 OVAL HEAD SCREW M3X6B 18
U24425007 BIND HEAD TAPTITE-B M4X25B 2
U24410007 BIND HEAD TAPTITE-B M4X10B 2
U70005002 PLAIN WASHER FW5NI 2
Non-designated parts are available only as part of a designated assembly.
S4000056(x4pcs) CASE LEG
R7153662(x2pcs) BLIND SHEET
R3084747 HANDLE
RA096120A
TOP CASE

CASE ASSY

RA0734000(x2pcs) PORON SHEET
R0115070A HANDLE SHAFT
R4115020A(x2pcs) HANDLE END
RA0006300 SP NET
FT-950 Technical Supplement
RA0719500(x2pcs) LEG
R7133800B(x2pcs) WASHER
RA072470A(x2pcs) LEG(IN)
RA072460A(x2pcs) LEG(F)
R7133800B(x2pcs) WASHER
RA0990500 PORON SHEET
RA0988400 GASKET
RA0866600 (x3pcs) SPONGE RUBBER
RA0988300(x2pcs) GASKET
RA096130A BOTTOM CASE
RA0733900(x4pcs) PORON SHEET
Exploded View-1
Exploded View
Panel ASSY (1/2)
REF. VXSTD P/N Description Qty.
U24306002 BIND HEAD TAPTITE-B M3X6NI 16
U34308001 FLAT HEAD TAPTITE-B M3X8 6
Non-designated parts are available only as part of a designated assembly.
RA0988500 SPONGE RUBBER
RA096180A SHIELD PLATE
RA0994000(x4pcs) PORON SHEET
RA0990600 DOUBLE FACE
RA0990700 GUIDE PLATE
RA0962100 BLIND SHEET
Exploded View-2
FT-950 Technical Supplement
Exploded View
Panel ASSY (2/2)
REF. VXSTD P/N Description Qty.
U24206001 BIND HEAD TAPTITE-B M2.6X6 9
U24105001 BIND HEAD TAPTITE-B M2X5 29
Non-designated parts are available only as part of a designated assembly.
RA0937000 PUSH KNOB(POW)
RA0937200 PUSH KNOB(LEFT)
RA0937300 KNOB ASSY(SEL)
RA0937700 PUSH KNOB(STO)
RA0937900
R7155600(x6pcs) HIMERON TAPE
RA0939000(x4pcs) VOLUME KNOB
RA0938900 ROTARY KNOB(SEL)
PUSH KNOB(MAINL) RA0936700
SPONGE RUBBER
RA0936500 WINDOW
U9900192(x2pcs) WAVE WASHER
RA0744600 SLEEVE
RA0729400(x4pcs) WASHER
SW-A-UNIT
RA0936900 KNOB ASSY(MOX)
T9207445 WIRE ASSY (SW-A-UNIT
VFD MODULE)
T9207130A WIRE ASSY (SW-A-UNIT
 
RA0938100 PUSH KNOB(MAINR)
RA0937600 PUSH KNOB(MRTX)
RA0936300 FRONT PANEL
CNTL-UNIT)
T9207433A WIRE ASSY (SW-A-UNIT VR-A-UNIT)
T9207434A WIRE ASSY (SW-A-UNIT SW-B-UNIT)
RA0938200 PUSH KNOB(CLAR)
RA0938300 PUSH KNOB(SRTX)
RA0938400 KNOB ASSY(BAGR)
RA0938400 KNOB ASSY(BAGR)

RA0938600 PUSH KNOB(10KEY)
MIC-UNIT
SW-B-UNIT
PHONE-UNIT
KEY-UNIT
VR-A-UNIT
R3135000A WASHER
R0134990A COIL SPRING
R6144801 NUT
Q7000605 VFD MODULE
Q9000833 ROTARY ENCODER
VR-B-UNIT
Q9000882 ROTARY ENCODER
RA0936800 PANEL FRAME
FT-950 Technical Supplement
RA0938800 VOLUME KNOB(IN)
RA0979400 KNOB MAIN ASSY
RA0939500 RUBBER RING(MAIN)
RA0950700 KNOB BASE(SUB)
RA0938700 VOLUME KNOB(OUT)
RA0829300 RUBBER RING (SUB)
Exploded View-3
Exploded View
CHASSIS ASSY (1/2)
REF. VXSTD P/N Description Qty.
U24306002 BIND HEAD TAPTITE-B M3X6NI 4
U44308002 PAN HEAD TAPTITE-B M3X8NI 4
U24306002 BIND HEAD TAPTITE-B M3X6NI 19
U03308002 SEMS SCREW ASM3X8NI 8
U51525020 HEXA SOCKET BOLT M5X25SUS 1
U66500002 FLANGE NUT N5NI 1
U70005002 PLAIN WASHER FW5NI 2
U72005002 TOOTHED LOCK WASHER OW5NI 2
U65500102 WING NUT N5NI 1
Non-designated parts are available only as part of a designated assembly.
T9207117A WIRE ASSY (PA-A-UNIT
RA0962300(x2pcs) SPONGE RUBBER
CNTL-UNIT)
PA-A-UNIT
M2090052 FAN
TUNER-UNIT
RA0962400 DOUBLE FACE
RA0962000 SP HOLDER
M4090125 SPEAKER
RA0961900(x2pcs) SHEET
RA0990400 SPONGE RUBBER
T9207317 WIRE ASSY
P1090984(x2pcs) CONNECTOR
RA0962500 DISPLAY PANEL
Exploded View-4
RA0957600 CHASSIS
FT-950 Technical Supplement
REF. VXSTD P/N Description Qty.
U24306002 BIND HEAD TAPTITE-B M3X6NI 26
U44308002 PAN HEAD TAPTITE-B M3X8NI 4
U03306002 SEMS SCREWAS M3X6NI 4
Non-designated parts are available only as part of a designated assembly.
CNTL-UNIT
Exploded View
CHASSIS ASSY (2/2)
RA0957600 CHASSIS
T9207130A WIRE ASSY (CNTL-UNIT
SW-A-UNIT)
T9207431A WIRE ASSY (CNTL-UNIT
TUNER-UNIT)
T9207432A WIRE ASSY (CNTL-UNIT
T9207115A WIRE ASSY (CNTL-UNIT
DSP-UNIT)
LOCAL-UNIT)
RA0423200 LOCK PLATE
T9207337 WIRE ASSY
T9207432A WIRE ASSY (CNTL-UNIT MAIN-UNIT)
(CNTL-UNIT MAIN-UNIT)
T9207337 WIRE ASSY (CNTL-UNIT
RA0961400 SHIELD CASE
DSP-UNIT
MAIN-UNIT)
T9207437 WIRE ASSY (MAIN-UNIT
SCP-UNIT)
MAIN-UNIT
FT-950 Technical Supplement
RA0961500 SHIELD CASE COVER
RA0470800 (x2 pcs) ELEC. COND TAPE
LOCAL-UNIT
Exploded View-5
Exploded View
NOTE:
Exploded View-6
FT-950 Technical Supplement

Block Diagram

FT-950 Technical Supplement
BLOCK DIAGRAM-1

Connection Diagram

CONNECTION DIAGRAM-1
FT-950 Technical Supplement

WIRE ASSY List

Parts List
REF DESCRIPTION VALUE V/W TOL. MFR'S DESIG VXSTD P/N VERS.
P 0001 WIRE ASSY 500MM9P (CNTL-TUNER) T9207431A P 0002 WIRE ASSY 70MM18P (CNTL-MAIN) T9207432A P 0003 WIRE ASSY 70MM18P (CNTL-DSP) T9207432A P 0004 WIRE ASSY 60MM18P (SW-A - VR-A) T9207433A P 0005 WIRE ASSY 65MM40P (SW-A - SW-B) T9207434A P 0006 WIRE ASSY 70MM (CNTL-MAIN) T9207337 P 0007 WIRE ASSY 70MM (CNTL-MAIN) T9207337 P 0008 WIRE ASSY (CNTL-LOCAL) T9207115A P 0009 WIRE ASSY (CNTL-PA-A) T9207117A P 0010 WIRE ASSY (CNTL - SW-A) T9207130A P 0011 WIRE ASSY 650MM8P (CNTL - PA-A) T9207435 P 0012 WIRE ASSY 70MM (CNTL-MAIN) T9207305 P 0013 WIRE ASSY 150MM (CNTL-MAIN) T9207306 P 0014 WIRE ASSY 220MM8PS (MAIN-DSP) T9207436 P 0015 WIRE ASSY 120MM14P (MAIN-SCP) T9207437 P 0016 WIRE ASSY 670MM2PFA (MAIN-SP) T9207438 P 0017 WIRE ASSY 460MM2P (MAIN-MIC) T9207439 P 0018 WIRE ASSY 280MM3P (MAIN-TUNER) T9207440 P 0019 WIRE ASSY 410MM3P (MAIN-PHONE) T9207442 P 0020 WIRE ASSY 70MM9P (SW-A - VFD) T9207445 P 0021 WIRE ASSY P 0022 WIRE ASSY P 0023 WIRE ASSY P 0024 WIRE ASSY P 0025 WIRE ASSY P 0026 WIRE ASSY P 0027 WIRE ASSY P 0028 WIRE ASSY P 0029 WIRE ASSY P 0030 WIRE ASSY
ORG 110 TMP/TMP (MAIN-LOCAL) GRA 320 TMP/TMP (MAIN-LOCAL) GRA 260 TMP/TMP (MAIN-LOCAL) GRA 190 TMP/TMP (LOCAL-SCP) GRA 210 TMP/TMP (MAIN-SCP) GRA 380 TMP/TMP (MAIN - PA-A) GRA 150 TMP/TMP (MAIN-TUNER) GRA 150 TMP/TMP (PA-A - TUNER) GRA 70 TMP/<3> (TUNER - ANT-2) GRA 70 TMP/<3> (TUNER - ANT-1)
T9318231A T9318311 T9318312 T9318306 T9318307 T9318313 T9318308 T9318308 T9318309 T9318309
LOT
SIDE
LAY ADR
FT-950 Technical Supplement
WIRE List-1
WIRE ASSY List
Parts List
Note
REF DESCRIPTION VALUE V/W TOL. MFR'S DESIG VXSTD P/N VERS.
LOT
SIDE
LAY ADR
WIRE List-2
FT-950 Technical Supplement

Alignment

Introduction and Precautions
The following procedures cover adjustments that are not normally required once the transceiver has left the factory. However, If a problem occurs during normal operation due to component failure; realign­ment may be required after the faulty components have been replaced.
We recommend that authorized Vertex Standard Technicians, who are experienced with the circuitry and fully equipped to repair and align our products, perform repairs. If a fault is suspected, contact the selling dealer for instructions regarding repair. Au­thorized Vertex Standard Technicians have the lat­est information to align all circuits and make com­plete performance checks to ensure compliance with factory specifications after repairs.
Those who do undertake any of the following align­ments are cautioned and proceed at their own risk. Problems caused by unauthorized attempts at re­alignment are not covered by the warranty policy.
Vertex Standard must reserve the right to change circuits and alignment procedures in the interest of improved performance, without notifying owners.
Under no circumstances should any alignment be attempted unless the normal functions and opera­tion of the transceiver are clearly understood, the cause of the malfunction has been clearly identified and all faulty components replaced. The need for realignment should be determined to be absolutely necessary.
The following test equipment (and a thorough fa­miliarity with its correct use) is necessary for correct realignment. Most steps do not require all of the equipment listed. The interactions of some adjust­ments may require that more complex adjustments be performed in a sequence. Do not attempt to per­form only a single step unless it is clearly isolated electrically from all other steps. Have all test equip­ment ready before beginning, and follow all of the steps in a section in the order they are presented.
Required Test Equipment
RF Signal GeneratorAF Signal GeneratorSpectrum Analyzer good to at least 1 GHz.Frequency CounterSINAD MeterRF MillivoltmeterElectronic LoadDigital DC Voltmeter (high-Z, 1 M-Ohm/V)DC VoltmeterDC Ammeter (20 A)OhmmeterDMU-2000 Data Management Unit50-Ohm Dummy Load (100 watts)In-Line Wattmeter (100 watts, 50-Ohm)Linear DetectorRF Coupler4-Ohm AF Dummy Load (3 watts)1/4-inch 3-contant Plug
Alignment Preparation & Precautions
A 50-ohm RF Dummy load and in-line wattmeter must be connected to the “ANT 1” jack in all proce­dures that call for transmission, except where speci­fied otherwise. Correct alignment is not possible with an antenna.
After completing one step, read the following step to determine whether the same test equipment will be required. If not, remove the unneeded test equip­ment before proceeding. (except the dummy load and wattmeter).
Correct alignment requires that the ambient temper­ature be maintained constant between 68 °F ~ 86 °F (20 °C ~ 30 °C). When the transceiver is brought into the shop from a hot or cold environment, it should be allowed time to come to room temperature be­fore alignment. Also, the test equipment must be thoroughly warmed up before beginning.
Whenever possible, alignments should be made with oscillator shields and circuit boards firmly affixed in place.
Important Notice
Do not adjust the alignment menus that are not mentioned in this manual.
FT-950 Technical Supplement
Note: Signal levels in dB referred to in this proce-
dure are based on 0 dBµ = 0.5 µV (closed cir­cuit).
ALIGNMENT-1
Alignment
VDD Meter Adjustment
Connect the DC voltmeter to pin 6 of J5402 on
the PA-A Unit.
Switch the external display to “SWR Monitor”
page.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “B-01 vdd”.
Press the [ENT] key, then rotate the [CLAR(VFO-
B)] knob so that the VDD meter reading is the same as that on the DC voltmeter.
Rotate the Main Tuning Dial knob to select the
alignment parameter “B-02 vdd”.
Rotate the [CLAR(VFO-B)] knob so that the VDD
meter (on the external display) reading is same as that on the DC voltmeter.
Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the align­ment mode.
Pin 6 of J5402
TP5032
ALIGNMENT-2
PA-A UNIT ALIGNMENT POINTS
FT-950 Technical Supplement
Alignment
2nd Local Oscillator Adjustment
Disconnect the coaxial cable from J4005 on the
LOCAL Unit, then connect the Frequency counter to J4005.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “C-08 FrE”.
Rotate the [CLAR(VFO-B)] knob so that the Fre-
quency counter reading is “69.000 MHz”.
Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the align­ment mode.
Disconnect the Frequency counter from J4005,
then connect the RF millivoltmeter to J4005.
Adjust T4003, T4004, and T4005 on the LOCAL
Unit for maximum deflection on the RF millivoltmeter (more than 0 dBm).
Disconnect the RF millivoltmeter from J4005, then
re-connect the coaxial cable to J4005.
PLL Adjustment
Connect the Digital DC voltmeter (high-Z) to
TP4005 on the LOCAL Unit.
Disconnect the coaxial cable from J4002 on the
LOCAL Unit, then connect the RF millivoltmeter to J4002.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Referring to the table below, select the appropri-
ate “Alignment Parameter” using the Main Tun­ing Dial knob per the chart below, and adjust the listed components for the required voltage, or confirm that the correct voltage is present on each alignment parameter.
ALIGNMENT PARAMETER
A-01 V1H A-02 V1L A-03 V2H A-04 V2L A-05 V3H A-06 V3L A-07 V4H A-08 V4L
Disconnect the RF millivoltmeter from J4002, then
re-connect the coaxial cable to J4002.
Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the align­ment mode.
ADJUST / CONFIRM
Adjust TC4004
Confirm
Adjust TC4003
Confirm
Adjust TC4002
Confirm
Adjust TC4001
Confirm
DC VOLTMETER
5.0 V ±0.1 V
At least 0.7 V
5.0 V ±0.1 V
At least 0.7 V
5.0 V ±0.1 V
At least 0.7 V
5.0 V ±0.1 V
At least 0.7 V
RF MILLIVOLTMETER
At least –3 dBm At least –3 dBm At least –3 dBm At least –3 dBm At least –3 dBm At least –3 dBm At least –3 dBm At least –3 dBm
J4002
TC4001
TC4002
TC4003
TC4004
FT-950 Technical Supplement
TP4005
T4003
T4004
J4005
T4005
LOCAL UNIT ALIGNMENT POINTS
ALIGNMENT-3
Alignment
Main Receiver Adjustment
1st Local Oscillator Adjustment
Set the following controls as indicated:
[ANT 1-2] button: ANT 1 [IPO] button: AMP1 [ATT] button: OFF [µ-TUNE] button: THRU [R.FLT] button: AUTO [AGC] button: AUTO [RF GAIN] knob: Fully clockwise [MODE] button: CW
Connect the RF millivoltmeter to TP1049 on the
MAIN Unit.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “C-03 L7”.
Rotate the [CLAR(VFO-B)] knob so that the RF
millivoltmeter reading is “1.0 Vrms ±0.05 V”, then press the [ENT] key.
Rotate the Main Tuning Dial knob to select the
alignment parameter “C-04 L14”.
Rotate the [CLAR(VFO-B)] knob so that the RF
millivoltmeter reading is “0.6 Vrms ±0.05 V”, then press the [ENT] key.
Rotate the Main Tuning Dial knob to select the
alignment parameter “C-07 L50”.
Rotate the [CLAR(VFO-B)] knob so that the RF
millivoltmeter reading is “0.7 Vrms ±0.05 V”, then press the [ENT] key.
Press and hold in the [MENU] button for one sec-
ond to save the new settings and exit the align­ment mode.
TP1055
T1028
TP1063
T1034 T1022
T1027
T1023
T1011
TP1049
J1028
T1019
T1026
T1025
T1024
T1033
T1032
T1031
TP1035 T1037
T1030
TP1059
T1029
ALIGNMENT-4
MAIN UNIT (RECEIVER SECTION
)
A
LIGNMENT POINTS
FT-950 Technical Supplement
Alignment
2nd/3rd
Connect the RF millivoltmeter to TP1063 on the
Adjust T1034 on the MAIN Unit for maximum
Connect the RF millivoltmeter to TP1055 on the
Adjust T1028 on the MAIN Unit for maximum
IF Transformer Adjustment
Set the VFO-A frequency to 14.200 MHz in the
Set the following controls as indicated:
Connect the AF millivoltmeter and 4 Ohm
Connect the RF Signal Generator to the “ANT 1”
Adjust T1025, T1032, T1037, T1030, T1027, and
Note: 1) If the S-meter deflects while adjusting, re­duce the RF Signal Generator output so that the S­meter does not deflect.
2) There are two peak points in the T1025 and T1032 adjustments. Adjust T1025 and T1032 so the cores are in the upper part of the coil.
Local Level Adjustment
MAIN Unit.
deflection on the RF millivoltmeter (more than +8 dBm).
MAIN Unit.
deflection on the RF millivoltmeter (more than 0 dBm).
CW mode.
[ANT 1-2] button: ANT 1 [IPO] button: AMP1 [ATT] button: OFF [µ-TUNE] button: THRU [R.FLT] button: 6 kHz [AGC] button: AUTO [RF GAIN] knob: Fully clockwise
dummy load to the EXT SP jack.
jack, then set the output level to 0 dBµ at the
14.200 MHz.
T1022 on the MAIN Unit in succession several times for maximum deflection on the AF millivoltmeter.
MCF Adjustment (1)
Set the VFO-A frequency to 14.200 MHz in the
CW mode.
Set the following controls as indicated:
[ANT 1-2] button: ANT 1 [IPO] button: AMP1 [ATT] button: OFF [µ-TUNE] button: THRU [R.FLT] button: 3 kHz [AGC] button: AUTO [RF GAIN] knob: Fully clockwise
Connect the AF millivoltmeter and 4 Ohm
dummy load to the EXT SP jack.
Connect the RF Signal Generator to the “ANT 1”
jack, then set the output level to 0 dBµ at the
14.200 MHz.
Adjust T1026 and T1033 on the MAIN Unit in
succession several times for maximum deflection on the AF millivoltmeter.
Note: 1) If the S-meter deflects while adjusting, re­duce the RF Signal Generator output so that the S­meter does not deflect.
2) There are two peak points in the T1026 and T1033 adjustments. Adjust T1026 and T1033 so the cores are in the upper part of the coil.
IF Trap Adjustment
Set the VFO-A frequency to 50.000 MHz in the
CW mode.
Set the following controls as indicated:
[ANT 1-2] button: ANT 1 [IPO] button: AMP1 [ATT] button: OFF [µ-TUNE] button: THRU [R.FLT] button: AUTO [AGC] button: AUTO [RF GAIN] knob: Fully clockwise
Connect the AF millivoltmeter and 4 Ohm
dummy load to the EXT SP jack.
Connect the RF Signal Generator to the “ANT 1”
jack, then set the output level to +60 ~ +90 dBµ at the 69.450 MHz.
Adjust T1011 on the MAIN Unit for minimum
deflection on the AF millivoltmeter.
Note: If the S-meter deflects while adjusting, reduce the RF Signal Generator output so that the S-meter does not deflect.
FT-950 Technical Supplement
ALIGNMENT-5
Alignment
MCF Adjustment (2)
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “G-03 FnG”.
Rotate the [CLAR(VFO-B)] knob so that the Mult-
Display Window shows “80”.
Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the align­ment mode.
Set the VFO-A frequency to 50.000 MHz in the
FM mode.
Set the following controls as indicated:
[ANT 1-2] button: ANT 1 [IPO] button: AMP2 [ATT] button: OFF [µ-TUNE] button: THRU [R.FLT] button: 15 kHz [AGC] button: AUTO [RF GAIN] knob: Fully clockwise
Connect the SINAD meter and 4 Ohm dummy
load to the EXT SP jack.
Connect the RF Signal Generator to the “ANT 1”
jack, then set the output level to –10 ~ 0 dBµ at the 50.000 MHz with ±3.5 kHz deviation FM modulation of a 1 kHz audio signal.
Adjust T1024 and T1031 on the MAIN Unit in
succession several times for maximum deflection on the SINAD meter.
Adjust T1022 on the MAIN Unit in succession
several times for maximum deflection on the SINAD meter. Note: Do not adjust T1022 more than 45 degrees rotation.
Noise Blanker Circuit Adjustment
Set the VFO-A frequency to 14.200 MHz in the
CW mode.
Set the following controls as indicated:
[ANT 1-2] button: ANT 1 [IPO] button: AMP1 [ATT] button: OFF [µ-TUNE] button: THRU [R.FLT] button: AUTO [AGC] button: AUTO [NB] button: ON (for short-duration pulse noise) [RF GAIN] knob: Fully clockwise
Connect the Digital DC voltmeter (high-Z) to
TP1059 on the MAIN Unit.
Connect the RF Signal Generator to the “ANT 1”
jack, then set the output level to 30 dBµ at 14.200 MHz.
Adjust T1029 and T1023 on the MAIN Unit for
minimum deflection on the DC voltmeter.
Turn the NB to “OFF” by pressing the [NB] but-
ton.
Scope Circuit Adjustment
Set the VFO-A frequency to 14.200 MHz in the
CW mode.
Set the following controls as indicated:
[ANT 1-2] button: ANT 1 [IPO] button: AMP1 [ATT] button: OFF [µ-TUNE] button: THRU [R.FLT] button: AUTO [AGC] button: AUTO [RF GAIN] knob: Fully clockwise
Disconnect the coaxial cable from J1028 on the
MAIN Unit, then connect the RF millivoltmeter to J1028.
Connect the RF Signal Generator to the “ANT 1”
jack, then set the output level to 80 dBµ at 14.200 MHz.
Adjust T1019 on the MAIN Unit for maximum
deflection on the RF millivoltmeter.
Disconnect the RF millivoltmeter from J1028, then
re-connect the coaxial cable to J1028.
ALIGNMENT-6
FT-950 Technical Supplement
Alignment
RF AGC Adjustment
Set the following controls as indicated:
[ANT 1-2] button: ANT 1 [IPO] button: AMP1 [ATT] button: OFF [µ-TUNE] button: THRU [R.FLT] button: 6 kHz [AGC] button: AUTO [RF GAIN] knob: Fully clockwise [MODE] button: CW
Connect the Digital DC voltmeter (high-Z) to
TP1035 on the MAIN Unit.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “D-05 rGc”.
Note the Digital DC voltmeter reading (with no
receive signal).
Rotate the [CLAR(VFO-B)] knob counter-clock-
wise just to the point where the Digital DC volt­meter reading is 0.01 V less than the voltage noted in the previous step.
Rotate the [CLAR(VFO-B)] knob clockwise just
to the point where the Digital DC voltmeter read­ing is the same as the previously noted voltage, then press the [ENT] key.
Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the align­ment mode.
IF Gain Adjustment
Set the VFO-A frequency to 1.900 MHz in the CW
mode.
Set the following controls as indicated:
[ANT 1-2] button: ANT 1 [IPO] button: AMP1 [ATT] button: OFF [µ-TUNE] button: THRU [R.FLT] button: 6 kHz [AGC] button: AUTO [RF GAIN] knob: Fully clockwise [MODE] button: CW
Set the CW PITCH frequency to “700 Hz” via
Menu item “045 A1A PITCH”.
Connect the AF millivoltmeter and 4 Ohm
dummy load to the EXT SP jack.
Connect the RF Signal Generator to the “ANT 1”
jack, then set the output level to 36 dBµ at 1.900 MHz.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Adjust the Main [AF GAIN] knob so that the AF
millivoltmeter reading is “0 dB.”
Refer to the chart below and select the appropri-
ate “Alignment Parameter” using the Main Tun­ing Dial knob per the chart below, then set the RF Signal Generator output to each frequency & level, and adjust the [CLAR(VFO-B)] knob for the corresponding AC millivoltmeter reading at each frequency.
ALIGNMENT PARAMETER
E-01 iGn E-02 iGn E-03 iGn E-04 iGn E-05 iGn E-06 iGn E-07 iGn E-08 iGn E-09 iGn E-10 iGn
RF SIGNAL GENERATOR
1.900 MHz, 9 dBµ
3.750 MHz, 9 dBµ
7.150 MHz, 9 dBµ
10.125 MHz, 9 dBµ
14.175 MHz, 9 dBµ
18.117 MHz, 9 dBµ
21.255 MHz, 9 dBµ
24.940 MHz, 9 dBµ
28.850 MHz, 9 dBµ
52.000 MHz, 9 dBµ
VFO-A FREQUENCY
1.900 MHz
3.750 MHz
7.150 MHz
10.125 MHz
14.175 MHz
18.117 MHz
21.255 MHz
24.940 MHz
28.850 MHz
52.000 MHz
AF MILLIVOLTMETER
–1.5 dB (±0.5 dB) –1.5 dB (±0.5 dB) –1.5 dB (±0.5 dB) –1.5 dB (±0.5 dB) –1.5 dB (±0.5 dB) –1.5 dB (±0.5 dB) –1.5 dB (±0.5 dB) –1.5 dB (±0.5 dB) –1.5 dB (±0.5 dB) –1.5 dB (±0.5 dB)
Press and hold in the [MENU] button for one sec-
ond to save the new settings and exit the align­ment mode.
FT-950 Technical Supplement
ALIGNMENT-7
Alignment
S-meter Adjustment
Set the VFO-A frequency to 14.200 MHz in the
CW mode.
Set the following controls as indicated:
[ANT 1-2] button: ANT 1 [IPO] button: AMP1 [ATT] button: OFF [µ-TUNE] button: THRU [R.FLT] button: 6 kHz [AGC] button: AUTO [RF GAIN] knob: Fully clockwise
Connect the RF Signal Generator to the “ANT 1”
jack, then set the frequency to 14.200 MHz.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Refer to the chart below and select the appropri-
ate “Alignment Parameter” using the Main Tun­ing Dial knob. Set the RF Signal Generator out­put to each level, and adjust the [CLAR(VFO-B)] knob for the corresponding S-meter reading. Press the [ENT] key to save the new setting at each level.
ALIGNMENT PARAMETER
F-01 S-0 F-02 S-1 F-03 S-5 F-04 S-7 F-05 S-9 F-06 S10 F-07 S20 F-08 S30 F-09 S40 F-10 S50 F-11 S60
RF SIGNAL GENERATOR
11 dBµ 13 dBµ 24 dBµ 30 dBµ 36 dBµ 46 dBµ 56 dBµ 66 dBµ 76 dBµ 86 dBµ 96 dBµ
MAIN S-METER
Turn on one dot
S-1 S-5 S-7
S-9 S-9+10dB S-9+20dB S-9+30dB S-9+40dB S-9+50dB S-9+60dB
Press and hold in the [MENU] button for one sec-
ond to save the new settings and exit the align­ment mode.
FM Gain Adjustment
Set the Main Band (VFO-A) frequency to 28.850
MHz in the FM-W mode.
Set the following controls as indicated:
[ANT 1-2] button: ANT 1 [IPO] button: AMP1 [ATT] button: OFF [µ-TUNE] button: THRU [R.FLT] button: 15 kHz [AGC] button: AUTO [RF GAIN] knob: Fully clockwise
Set the RF Signal Generator to 12 dBµ at the
28.8500 MHz with ±3.5 kHz deviation FM modu­lation of a 1 kHz audio signal.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “G-02 FnG”.
Rotate the [CLAR(VFO-B)] knob so that the S-
meter reading is “S-3”.
Press and hold in the [MENU] button for 2 sec-
onds to save the new setting and exit the align­ment mode.
Set the RF Signal Generator to 12 dBµ at the 52.000
MHz with ±3.5 kHz deviation FM modulation of a 1 kHz audio signal.
Set the VFO-A frequency to 52.000 MHz in the
FM-W mode.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode again.
Rotate the Main Tuning Dial knob to select the
alignment parameter “G-03 FnG”.
Rotate the [CLAR(VFO-B)] knob so that the S-
meter reading is “S-3”.
Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the align­ment mode.
ALIGNMENT-8
FT-950 Technical Supplement
Transmitter Adjustment
TX IFT Adjustment
Disconnect the coaxial cable from J1011 on the
MAIN Unit, then connect the RF millivoltmeter to J1011.
Set the VFO-A frequency to 14.200 MHz in the
FM mode.
Set the value of Menu item “111 TGEN TX PWR”
to “100”.
Press the PTT button, adjust T1021, T1014, T1010,
and T1009 for maximum deflection on the RF millivoltmeter.
Release the PTT button.Disconnect the RF millivoltmeter from J1011, then
re-connect the coaxial cable to J1011.
Alignment
TX Scope Circuit Adjustment
Disconnect the coaxial cable from J1028 on the
MAIN Unit, then connect the RF millivoltmeter to J1028.
Set the VFO-A frequency to 14.200 MHz in the
CW mode.
Set the value of Menu item “111 TGEN TX PWR”
to “100”.
Press the PTT button, then adjust T1006 for maxi-
mum deflection on the RF millivoltmeter.
Release the PTT button.Disconnect the RF millivoltmeter from J1028, then
re-connect the coaxial cable to J1028.
J1011
T1009
T1010
J1028
T1006
T1014
T1021
FT-950 Technical Supplement
MAIN UNIT (TRANSMITTER SECTION
)
A
LIGNMENT POINTS
ALIGNMENT-9
Alignment
PA-A Unit Adjustment
Preparation
Connect the 50-Ohm Dummy Load and Wattme-
ter to the “ANT 1” jack.
Disconnect the coaxial cables from J5001 and
J5006 on the PA-A Unit, then terminate J5001 and J5006, each with a 50-Ohm resistor.
Disconnect the jumper plugs from J5003 and
J5004 on the PA-A Unit, and remove the jumper wire that is connected between TP5031 and TP5032 on the PA-A Unit.
Pre-Drive Stage Idling Current Adjustment
Connect the DC ammeter to J5003 on the PA-A
Unit.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “H-01 Pdb”.
Press the PTT button, then adjust the
[CLAR(VFO-B)] knob so that the DC ammeter reading is “100 mA (±5 mA)”.
Release the PTT button.
J5006
TP5032
TP5031
J5004
J5003
ALIGNMENT-10
J5001
PA-A UNIT ALIGNMENT POINTS
FT-950 Technical Supplement
Drive Stage Idling Current Adjustment
Connect the DC ammeter to J5004 on the PA-A
Unit.
Rotate the Main Tuning Dial knob to select the
alignment parameter “H-02 db1”.
Press the PTT button, then adjust the
[CLAR(VFO-B)] knob so that the DC ammeter reading is “500 mA (±50 mA)”.
Release the PTT button.Rotate the Main Tuning Dial knob to select the
alignment parameter “H-03 db2”.
Press the PTT button, then adjust the
[CLAR(VFO-B)] knob so that the DC ammeter reading is “500 mA (±50 mA)”.
Release the PTT button.
Final Stage Idling Current Adjustment
Connect the DC ammeter between TP5031 and
TP5032 on the PA-A Unit.
Rotate the Main Tuning Dial knob to select the
alignment parameter “H-04 Fb1”.
Press the PTT button, then adjust the
[CLAR(VFO-B)] knob so that the DC ammeter reading is “1 A (±50 mA)”.
Release the PTT button.Rotate the Main Tuning Dial knob to select the
alignment parameter “H-05 Fb2”.
Press the PTT button, then adjust the
[CLAR(VFO-B)] knob so that the DC ammeter reading is “1 A (±50 mA)”.
Release the PTT button.
Alignment
Antenna Tuner Adjustment
CM Coupler Balance Adjustment
Connect the 50-Ohm Dummy Load and Wattme-
ter to the “ANT 1” jack.
Connect the Digital DC voltmeter (high-Z) to pin
3 of J6003 on the TUNER Unit.
Turn off the [TUNE] switch, then set the VFO-A
frequency to 24.900 MHz in the CW mode.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “I-08 iAL”.
Press the PTT button, then rotate the
[CLAR(VFO-B)] knob for 50 Watts on the Watt­meter.
Adjust TC6001 on the TUNER Unit for minimum
deflection on the DC voltmeter (less than 0.1 V).
Release the PTT button, then press the [MENU]
button momentarily to exit the alignment mode.
Pin 3 of J6003
TC6001
Termination
Press and hold in the [MENU] button for one sec-
ond to save the new settings and exit the align­ment mode.
Disconnect the 50-Ohm resistors from J5001 and
J5006, then connect the coaxial cables to J5001 and J5006.
Re-connect the jumper plugs to J5003 and J5004,
and re-connect the jumper wire between TP5031 and TP5032.
FT-950 Technical Supplement
TUNER UNIT ALIGNMENT POINTS
ALIGNMENT-11
Alignment
Current ALC Adjustment
Connect the 50-Ohm Dummy Load and Wattme-
ter to the “ANT 1” jack.
Set the VFO-A frequency to 3.750 MHz in the CW
mode.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “I-02 iAL”.
Press the PTT button, then adjust the
[CLAR(VFO-B)] knob for 125 W (+5W/–0W) on the Wattmeter.
Release the PTT button, then press the [ENT] key.Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the align­ment mode.
ALC Meter Adjustment
Connect the 50-Ohm Dummy Load and Wattme-
ter to the “ANT 1” jack.
Set the VFO-A frequency to 14.200 MHz in the
CW mode.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “N-01 P1h”.
Rotate the [CLAR(VFO-B)] knob so that the
Multi-Display Window shows “0”.
Press the PTT button, then rotate the
[CLAR(VFO-B)] knob for 100 W (+5W/–0W) on the Wattmeter.
Release the PTT button.Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the align­ment mode.
Set the VFO-A frequency to 14.200 MHz in the
USB mode.
Set the value of Menu item “111 TGEN TX PWR”
to “100”.
Connect the Audio Generator to
pin 8 of the MIC jack (pin 7: GND), then set the output level to 0.5 mV @1 kHz.
Set the MIC GAIN knob to 12 o'clock position.Press the PTT button, then adjust the Audio Gen-
erator output level to the position where the ALC meter just starts to deflect.
Release the PTT button.Increase the Audio Generator output level by “9
dB”.
Press the [ENT] key while pressing and holding
in the PTT button.
Release the PTT button, then press and hold in
the [MENU] button for one second to save the new setting and exit the alignment mode.
MIC IN
MIC GND
ALIGNMENT-12
FT-950 Technical Supplement
TX Output Power/PO Meter/TXG Adjustment
Referring to table below, tune the transceiver to
each frequency listed.
BAND
1.8 MHz Band
3.5 MHz Band 7 MHz Band
10 MHz Band 14 MHz Band 18 MHz Band 21 MHz Band
24.5 MHz Band 28 MHz Band 50 MHz Band
VFO-A FREQUENCY
1.820 MHz
3.570 MHz
7.050 MHz
10.100 MHz
14.200 MHz
18.100 MHz
21.200 MHz
24.900 MHz
28.700 MHz
52.000 MHz
UK: 51.000 MHz, EU: 50.250 MHz, FRA: 50.700 MHz
Ú
Ú
MODE
CW CW CW CW CW CW CW CW CW CW
Connect the 50-Ohm Dummy Load and Wattme-
ter to the “ANT 1” jack.
Set the VFO-A frequency to 1.820 MHz in the CW
mode.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Rotate the Main Dial knob to select the alignment
Press the PTT button, then rotate the
Release the button.Rotate the Main Dial knob to select the alignment
Press the PTT button to save the new setting.Release the button.Rotate the Main Dial knob to select the alignment
Press the PTT button, then rotate the
Release the button.
Alignment
parameter “J-01 P1h”.
[CLAR(VFO-B)] knob for 101 W (+5W/–1W) on the Wattmeter.
parameter “J-02 P1h”.
parameter “J-03 P1h”.
[CLAR(VFO-B)] knob for maximum deflection on the ALC meter zone.
ALIGNMENT MENU
J-01 P1h J-02 P1h J-03 P1h J-04 P50 J-05 P50 J-06 P50 J-07 P20 J-08 P20
1.9 MHZ3.5 MHZ7 MHZ
J-09 P20 J-10 P10 J-11 P10 J-12 P10 J-13 P05 J-14 P05
J-15 P05 K-01 P1h K-02 P1h K-03 P1h K-04 P50 K-05 P50 K-06 P50 K-07 P20 K-08 P20 K-09 P20 K-10 P10 K-11 P10 K-12 P10 K-13 P05 K-14 P05 K-15 P05 L-01 P1h L-02 P1h L-03 P1h L-04 P50 L-05 P50 L-06 P50 L-07 P20 L-08 P20 L-09 P20 L-10 P10
L-11 P10 L-12 P10 L-13 P05 L-14 P05 L-15 P05
Note: The 10 MHz, 18 MHz, 21 MHz, and 28 MHz bands do not need the adjustment.
OPERATION
Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
[
PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob
POWER METER
(
)
A
DJUST TO
101 W (+5 W / –1 W
– –
50 W (+5 W / –0 W
– –
20 W (+2 W / –0 W
– –
10 W (+1 W / –0 W
– –
5 W (+1 W / –0 W
– –
101 W (+5 W / –1 W
– –
50 W (+5 W / –0 W
– –
20 W (+2 W / –0 W
– –
10 W (+1 W / –0 W
– –
5 W (+1 W / –0 W
– –
101 W (+5 W / –1 W
– –
50 W (+5 W / –0 W
– –
20 W (+2 W / –0 W
– –
10 W (+1 W / –0 W
– –
5 W (+1 W / –0 W
– –
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
FT-950 Technical Supplement
ALC METER
(
)
A
DJUST TO
– –
Turns on 16 dots
– –
Turns on 16 dots
– –
Turns on 16 dots
– –
Turns on 16 dots
– –
Turns on 13 dots
– –
Turns on 16 dots
– –
Turns on 16 dots
– –
Turns on 16 dots
– –
Turns on 16 dots
– –
Turns on 13 dots
– –
Turns on 16 dots
– –
Turns on 16 dots
– –
Turns on 16 dots
– –
Turns on 16 dots
– –
Turns on 13 dots
ALIGNMENT MENU
N-01 P1h N-02 P1h N-03 P1h N-04 P50 N-05 P50 N-06 P50 N-07 P20 N-08 P20
14 MHZ24 MHZ50 MHZ
N-09 P20 N-10 P10 N-11 P10 N-12 P10 N-13 P05 N-14 P05 N-15 P05 Q-01 P1h Q-02 P1h Q-03 P1h Q-04 P50 Q-05 P50 Q-06 P50 Q-07 P20 Q-08 P20 Q-09 P20 Q-10 P10 Q-11 P10 Q-12 P10 Q-13 P05 Q-14 P05 Q-15 P05 S-01 P1h S-02 P1h S-03 P1h S-04 P50 S-05 P50 S-06 P50 S-07 P20 S-08 P20 S-09 P20 S-10 P10
S-11 P10 S-12 P10 S-13 P05 S-14 P05 S-15 P05
OPERATION
Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
[
PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button Rotate the [CLAR(VFO-B)] knob
POWER METER
(
)
A
DJUST TO
101 W (+5 W / –1 W
50 W (+5 W / –0 W
20 W (+2 W / –0 W
10 W (+1 W / –0 W
5 W (+1 W / –0 W
101 W (+5 W / –1 W
50 W (+5 W / –0 W
20 W (+2 W / –0 W
10 W (+1 W / –0 W
5 W (+1 W / –0 W
101 W (+5 W / –1 W
50 W (+5 W / –0 W
20 W (+2 W / –0 W
10 W (+1 W / –0 W
5 W (+1 W / –0 W
) – –
) – –
) – –
) – –
) – –
) – –
) – –
) – –
) – –
) – –
) – –
) – –
) – –
) – –
) – –
ALIGNMENT-13
ALC METER
(
)
A
DJUST TO
– –
Turns on 16 dots
– –
Turns on 16 dots
– –
Turns on 16 dots
– –
Turns on 16 dots
– –
Turns on 13 dots
– –
Turns on 16 dots
– –
Turns on 16 dots
– –
Turns on 16 dots
– –
Turns on 16 dots
– –
Turns on 13 dots
– –
Turns on 16 dots
– –
Turns on 16 dots
– –
Turns on 16 dots
– –
Turns on 16 dots
– –
Turns on 13 dots
Alignment
Perform the same procedures for the Alignment
Menus “J-04 P50” through “J-15 P05”, “K-01 P1h” through “K-15 P05”, “L-01 P1h” through “L-15 P05” per the chart at the right.
Press the [ENT] key to save the new setting at 1.8
MHz, 3.5 MHz, 7 MHz, and 10 MHz Bands.
Perform the same procedures for the Alignment
Menus “N-01 P1h” through “N-15 P05” per the chart at the right.
Press the [ENT] key to save the new setting at 14
MHz, 18 MHz, and 21 MHz Bands.
Perform the same procedures for the Alignment
Menus “Q-01 P1h” through “Q-15 P05” per the chart at the right.
Press the [ENT] key to save the new setting at 24
MHz and 28 MHz Bands.
Perform the same procedures for the Alignment
Menus “S-01 P1h” through “S-15 P05” per the chart below.
Press and hold in the [MENU] button for one sec-
ond to save the new settings and exit the align­ment mode.
AM-TXG Adjustment
Connect the 50-Ohm Dummy Load and Wattme-
ter to the “ANT 1” jack.
Set the value of Menu item “111 TGEN TX PWR”
to “100”, and Menu item “112 TGEN AM CAR” to “100”.
Set the VFO-A frequency to 14.200 MHz in the
AM mode.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “T-02 tCA.”
Rotate the [CLAR(VFO-B)] knob so that the
Multi-Display Window shows “0”.
Press the PTT button without microphone input,
then rotate the [CLAR(VFO-B)] knob for 70 W (±5 W) on the Wattmeter.
Release the PTT button.Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the align­ment mode.
REV-ALC Adjustment
Disconnect the test equipment from the “ANT 1”
jack.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “U-01 rAC.”
Press the PTT button, then rotate the
[CLAR(VFO-B)] knob so that the PO meter turns on 14 dots.
Release the PTT button, then press the [ENT] key.Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the align­ment mode.
ALIGNMENT-14
FT-950 Technical Supplement
Alignment
ID Meter Adjustment
Choose one of the adjustment methods described below, according to the equipment you have available. If you perform adjustment method (2) Using a DC Ammeter, complete the transmit adjustments on ALIGNMENT page 9 through 14.
1) Using an Electronic Load
Remove the jumper wire that is connected be-
tween TP5031 and TP5032 on the PA-A Unit, then connect the Electronic Load to TP5032 and GND.
Set the VFO-A frequency to 14.200 MHz in the
CW mode.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “X-01 Idd”.
Press the PTT button, then adjust the Electronic
Load to “10 A”.
Press the [ENT] key, then release the PTT button.Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the align­ment mode.
2) Using a DC Ammeter
Connect the 50-Ohm Dummy Load and Wattme-
ter to the “ANT 1” jack.
Remove the jumper wire that is connected be-
tween TP5031 and TP5032 on the PA-A Unit, then connect the DC ammeter (15-A range) between TP5031 and TP5032.
Set the VFO-A frequency to 14.200 MHz in the
CW mode.
Press the PTT button, set the DC ammeter for 10
A via Menu item “111 TGEN TX PWR”.
Release the PTT button, then press and hold in
the [MENU] button for one second to save the new setting and exit the menu mode.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “X-01 Idd”.
Press the PTT button, confirm the DC ammeter
readig is 10 A.
Press the [ENT] key, then release the PTT button.Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the align­ment mode.
FT-950 Technical Supplement
TP5032
TP5031
PA-A UNIT ALIGNMENT POINTS
ALIGNMENT-15
Alignment
FM MAX Deviation Adjustment
Connect the Dummy Load, Wattmeter, and De-
viation Meter to the “ANT 1” Jack.
Set the VFO-A frequency to 28.700 MHz in the
FM mode.
Set the value of Menu item “056 F3E MIC ” to
“50”.
Connect the Audio Generator to
pin 8 of the MIC jack (pin 7: GND), then set the output level to 2 mV @1 kHz.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “V-02 F45”.
Press the PTT button, then rotate the
[CLAR(VFO-B)] knob for 4.5 kHz (±0.2 kHz) on the Deviation Meter.
Release the PTT button.Press the [NAR] button to set the VFO-A operat-
ing mode to the FM-N mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “V-03 F23”.
Press the PTT button, then rotate the
[CLAR(VFO-B)] knob for 2.25 kHz (±0.15 kHz) on the Deviation Meter.
Release the PTT button.Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the align­ment mode.
MIC IN
MIC GND
SWR Meter Adjustment
Set the VFO-A frequency to 28.700 MHz in the
CW mode.
Connect the 50-Ohm Dummy Load and Wattme-
ter to the “ANT 1” Jack.
Connect the 1/4-inch 3-contact Plug to the KEY
jack (but, without the key).
Set the Multi Function Meter to “SWR” by press-
ing the [METER] button.
Disconnect the 3-pin plug from J1014 on the
MAIN Unit, then apply a 2.75 V DC voltage to pin 2 of J1014, and 1.00 V DC to pin 3 of J1014.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “W-03 S30.”
Press the [MOX] button, then rotate the
[CLAR(VFO-B)] knob so that the SWR meter (on the front panel) reading is “3.0”. The SWR meter reading (3.0) is broad (few points). Therefore, set the [CLAR(VFO-B)] knob to the center of this broad range.
Release the [MOX] button.Apply a 2.96 V DC voltage to pin 2 of J1014, and
1.00 V DC to pin 3 of J1014.
Rotate the Main Tuning Dial knob to select the
alignment parameter “W-06 S30.”
Press the [MOX] button, then rotate the
[CLAR(VFO-B)] knob so that the SWR meter (on the front panel) reading is “3.0.” The SWR meter reading (3.0) is broad (few points). Therefore, set the [CLAR(VFO-B)] knob to the center of this broad range.
Release the [MOX] button.Apply a 3.81 V DC voltage to pin 2 of J1014, and
1.00 V DC to pin 3 of J1014.
Rotate the Main Tuning Dial knob to select the
alignment parameter “W-09 S30.”
Press the [MOX] button, then rotate the
[CLAR(VFO-B)] knob so that the SWR meter (on the front panel) reading is “3.0.” The SWR meter reading (3.0) is broad (few points). Therefore, set the [CLAR(VFO-B)] knob to the center of this broad range.
Release the [MOX]button.Press and hold in the [MENU] button for 2 sec-
onds to save the new settings and exit the align­ment mode.
Re-connect the 3-pin plug to J1014 on the MAIN
Unit.
ALIGNMENT-16