This manual provides technical information necessary for servicing the FT-950 HF/50 MHz Transceiver.
Servicing this equipment requires expertise in handling surface-mount chip components. Attempts by
non-qualified persons to service this equipment
may result in permanent damage not covered by
the warranty, and may be illegal in some countries.
Two PCB layout diagrams are provided for each
double-sided circuit board in the Transceiver. Each
side of is referred to by the type of the majority of
components installed on that side (“leaded” or “chiponly”). In most cases one side has only chip components, and the other has either a mixture of both
chip and leaded components (trimmers, coils, electrolytic capacitors, ICs, etc.), or leaded components
only.
While we believe the technical information in this
manual to be correct, VERTEX STANDARD assumes no liability for damage that may occur as a
result of typographical or other errors that may be
present. Your cooperation in pointing out any inconsistencies in the technical information would be
appreciated.
VERTEX STANDARD CO., LTD.
4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan
VERTEX STANDARD
US Headquarters
10900 Walker Street, Cypress, CA 90630, U.S.A.
YAESU EUROPE B.V.
P.O. Box 75525, 1118 ZN Schiphol, The Netherlands
YAESU UK LTD.
Unit 12, Sun Valley Business Park, Winnall Close
Winchester, Hampshire, SO23 0LB, U.K.
VERTEX STANDARD HK LTD.
Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road,
Kwun Tong, Kowloon, Hong Kong
VERTEX STANDARD (AUSTRALIA) PTY., LTD.
Normanby Business Park, Unit 14/45 Normanby Road
Notting Hill 3168, Victoria, Australia
Contents
Introduction
Specifications
Exploded View
Block Diagram
Connection Diagram
WIRE ASSY List
Alignment
Board Unit (Schematics, Layouts & Parts)
MAIN Unit
CNTL Unit
LOCAL Unit
PA-A Unit
TUNER Unit
DSP Unit
SW-A Unit
SW-B Unit
VR-A Unit
VR-B Unit
PHONE Unit
MIC Unit
KEY Unit
DVS-6 Unit (Option)
Important Note
This transceiver was assembled using Pb (lead) free solder, based on the RoHS specification.
Only lead-free solder (Alloy Composition: Sn-3.0Ag-0.5Cu) should be used for repairs performed on this apparatus. The solder
stated above utilizes the alloy composition required for compliance with the lead-free specification, and any solder with the
above alloy composition may be used.
FT-950 Technical Supplement
Specifications-1
Specifications
General
Rx Frequency Range:30 kHz - 56 MHz (operating)
160 - 6 m (specified performance, Amateur bands only)
Tx Frequency Ranges:160 - 6 m (Amateur bands only)
Frequency Stability:±0.5 ppm (after 1 minute @+77 °F [+25 °C])
Maximum FM Deviation:±5.0 kHz/±2.5 kHz
Harmonic Radiation:Better than -60 dB (160 - 10m Amateur bands: Harmonics)
Better than -50 dB (160 - 10m Amateur bands: Others)
Better than -65 dB (6m Amateur band)
SSB Carrier Suppression:At least 60 dB below peak output
Undesired Sideband Suppression:At least 60 dB below peak output
3rd-order IMD:-31 dB @14 MHz 100 watts PEP
Bandwidth:3 kHz (LSB/USB), 500 Hz (CW), 6 kHz (AM), 16 kHz (FM)
Audio Response (SSB):Not more than -6 dB from 300 to 2700 Hz
Microphone Impedance:600 Ohms (200 to 10 kOhms)
Specifications-2
FT-950 Technical Supplement
Specifications
Receiver
Circuit Type:Triple-conversion Superheterodyne
Intermediate Frequencies:69.450 MHz/450 kHz/30 kHz (24 kHz for AM/FM)
Sensitivity:SSB (BW: 2.4 kHz, 10 dB S+N/N)
4 µV (0.5 - 1.8 MHz) (IPO "ON")
0.2 µV (1.8 - 30 MHz) (AMP 2 "ON")
0.125 µV (50 - 54 MHz) (AMP 2 "ON")
AM (BW: 6 kHz, 10 dB S+N/N, 30 % modulation @400 Hz)
There is no specification for frequency ranges not listed.
Squelch Sensitivity:SSB/CW/AM
2 µV (0.1 - 1.8 MHz)
2 µV (50 - 54 MHz)
FM
1 µV (28 - 30 MHz)
1 µV (50 - 54 MHz)
There is no specification for frequency ranges not listed.
Selectivity (WIDTH: Center):Mode-6 dB -60 dB
CW/RTTY/PKT0.5 kHz or better 750 Hz or less
SSB2.4 kHz or better 3.6 kHz or less
AM6 kHz or better 15 kHz or less
FM15 kHz or better 25 kHz or less
Image Rejection:70 dB or better (160 - 10m Amateur bands)
60 dB or better (6m Amateur band)
Maximum Audio Output:2.5 W into 4 Ohms with 10% THD
Audio Output Impedance:4 to 8 Ohms (4 Ohms: nominal)
Conducted Radiation:Less than 4 nW
Specifications are subject to change, in the interest of technical improvement, without notice or obligation,
and are guaranteed only within the amateur bands.
FT-950 Technical Supplement
Specifications-3
Specifications
Note
Specifications-4
FT-950 Technical Supplement
Exploded View
REF. VXSTD P/NDescriptionQty.
U31406007 OVAL HEAD SCREW M4X6B6
U20308007 BINDING HEAD SCREW M3X8B5
U24305007 BIND HEAD TAPTITE-B M3X5B4
U31410020 OVAL HEAD SCREW M4X10SUS2
U31306007 OVAL HEAD SCREW M3X6B18
U24425007 BIND HEAD TAPTITE-B M4X25B2
U24410007 BIND HEAD TAPTITE-B M4X10B2
U70005002 PLAIN WASHER FW5NI2
Non-designated parts are available only as part of a designated
assembly.
S4000056(x4pcs)
CASE LEG
R7153662(x2pcs)
BLIND SHEET
R3084747
HANDLE
RA096120A
TOP CASE
CASE ASSY
RA0734000(x2pcs)
PORON SHEET
R0115070A
HANDLE SHAFT
R4115020A(x2pcs)
HANDLE END
RA0006300
SP NET
FT-950 Technical Supplement
RA0719500(x2pcs)
LEG
R7133800B(x2pcs)
WASHER
RA072470A(x2pcs)
LEG(IN)
RA072460A(x2pcs)
LEG(F)
R7133800B(x2pcs)
WASHER
RA0990500
PORON SHEET
RA0988400
GASKET
RA0866600 (x3pcs)
SPONGE RUBBER
RA0988300(x2pcs)
GASKET
RA096130A
BOTTOM CASE
RA0733900(x4pcs)
PORON SHEET
Exploded View-1
Exploded View
Panel ASSY (1/2)
REF. VXSTD P/NDescriptionQty.
U24306002 BIND HEAD TAPTITE-B M3X6NI16
U34308001 FLAT HEAD TAPTITE-B M3X86
Non-designated parts are available only as part of a designated
assembly.
RA0988500
SPONGE RUBBER
RA096180A
SHIELD PLATE
RA0994000(x4pcs)
PORON SHEET
RA0990600
DOUBLE FACE
RA0990700
GUIDE PLATE
RA0962100
BLIND SHEET
Exploded View-2
FT-950 Technical Supplement
Exploded View
Panel ASSY (2/2)
REF. VXSTD P/NDescriptionQty.
U24206001 BIND HEAD TAPTITE-B M2.6X69
U24105001 BIND HEAD TAPTITE-B M2X529
Non-designated parts are available only as part of a designated
assembly.
RA0937000
PUSH KNOB(POW)
RA0937200
PUSH KNOB(LEFT)
RA0937300
KNOB ASSY(SEL)
RA0937700
PUSH KNOB(STO)
RA0937900
R7155600(x6pcs)
HIMERON TAPE
RA0939000(x4pcs)
VOLUME KNOB
RA0938900
ROTARY KNOB(SEL)
PUSH KNOB(MAINL)
RA0936700
SPONGE RUBBER
RA0936500
WINDOW
U9900192(x2pcs)
WAVE WASHER
RA0744600
SLEEVE
RA0729400(x4pcs)
WASHER
SW-A-UNIT
RA0936900
KNOB ASSY(MOX)
T9207445
WIRE ASSY
(SW-A-UNIT
VFD MODULE)
T9207130A
WIRE ASSY
(SW-A-UNIT
RA0938100
PUSH KNOB(MAINR)
RA0937600
PUSH KNOB(MRTX)
RA0936300
FRONT PANEL
CNTL-UNIT)
T9207433A
WIRE ASSY
(SW-A-UNITVR-A-UNIT)
T9207434A
WIRE ASSY
(SW-A-UNITSW-B-UNIT)
RA0938200
PUSH KNOB(CLAR)
RA0938300
PUSH KNOB(SRTX)
RA0938400
KNOB ASSY(BAGR)
RA0938400
KNOB ASSY(BAGR)
RA0938600
PUSH KNOB(10KEY)
MIC-UNIT
SW-B-UNIT
PHONE-UNIT
KEY-UNIT
VR-A-UNIT
R3135000A
WASHER
R0134990A
COIL SPRING
R6144801
NUT
Q7000605
VFD MODULE
Q9000833
ROTARY ENCODER
VR-B-UNIT
Q9000882
ROTARY ENCODER
RA0936800
PANEL FRAME
FT-950 Technical Supplement
RA0938800
VOLUME KNOB(IN)
RA0979400
KNOB MAIN ASSY
RA0939500
RUBBER RING(MAIN)
RA0950700
KNOB BASE(SUB)
RA0938700
VOLUME KNOB(OUT)
RA0829300
RUBBER RING (SUB)
Exploded View-3
Exploded View
CHASSIS ASSY (1/2)
REF. VXSTD P/NDescriptionQty.
U24306002 BIND HEAD TAPTITE-B M3X6NI4
U44308002 PAN HEAD TAPTITE-B M3X8NI4
U24306002 BIND HEAD TAPTITE-B M3X6NI19
U03308002 SEMS SCREW ASM3X8NI8
U51525020 HEXA SOCKET BOLT M5X25SUS1
U66500002 FLANGE NUT N5NI1
U70005002 PLAIN WASHER FW5NI2
U72005002 TOOTHED LOCK WASHER OW5NI2
U65500102 WING NUT N5NI1
Non-designated parts are available only as part of a designated
assembly.
T9207117A
WIRE ASSY
(PA-A-UNIT
RA0962300(x2pcs)
SPONGE RUBBER
CNTL-UNIT)
PA-A-UNIT
M2090052
FAN
TUNER-UNIT
RA0962400
DOUBLE FACE
RA0962000
SP HOLDER
M4090125
SPEAKER
RA0961900(x2pcs)
SHEET
RA0990400
SPONGE RUBBER
T9207317
WIRE ASSY
P1090984(x2pcs)
CONNECTOR
RA0962500
DISPLAY PANEL
Exploded View-4
RA0957600
CHASSIS
FT-950 Technical Supplement
REF. VXSTD P/NDescriptionQty.
U24306002 BIND HEAD TAPTITE-B M3X6NI26
U44308002 PAN HEAD TAPTITE-B M3X8NI4
U03306002 SEMS SCREWAS M3X6NI4
Non-designated parts are available only as part of a designated
assembly.
P 0001WIRE ASSY500MM9P (CNTL-TUNER)T9207431A
P 0002WIRE ASSY70MM18P (CNTL-MAIN)T9207432A
P 0003WIRE ASSY70MM18P (CNTL-DSP)T9207432A
P 0004WIRE ASSY60MM18P (SW-A - VR-A)T9207433A
P 0005WIRE ASSY65MM40P (SW-A - SW-B)T9207434A
P 0006WIRE ASSY70MM (CNTL-MAIN)T9207337
P 0007WIRE ASSY70MM (CNTL-MAIN)T9207337
P 0008WIRE ASSY(CNTL-LOCAL)T9207115A
P 0009WIRE ASSY(CNTL-PA-A)T9207117A
P 0010WIRE ASSY(CNTL - SW-A)T9207130A
P 0011WIRE ASSY650MM8P (CNTL - PA-A)T9207435
P 0012WIRE ASSY70MM (CNTL-MAIN)T9207305
P 0013WIRE ASSY150MM (CNTL-MAIN)T9207306
P 0014WIRE ASSY220MM8PS (MAIN-DSP)T9207436
P 0015WIRE ASSY120MM14P (MAIN-SCP)T9207437
P 0016WIRE ASSY670MM2PFA (MAIN-SP)T9207438
P 0017WIRE ASSY460MM2P (MAIN-MIC)T9207439
P 0018WIRE ASSY280MM3P (MAIN-TUNER)T9207440
P 0019WIRE ASSY410MM3P (MAIN-PHONE)T9207442
P 0020WIRE ASSY70MM9P (SW-A - VFD)T9207445
P 0021WIRE ASSY
P 0022WIRE ASSY
P 0023WIRE ASSY
P 0024WIRE ASSY
P 0025WIRE ASSY
P 0026WIRE ASSY
P 0027WIRE ASSY
P 0028WIRE ASSY
P 0029WIRE ASSY
P 0030WIRE ASSY
ORG 110 TMP/TMP (MAIN-LOCAL)
GRA 320 TMP/TMP (MAIN-LOCAL)
GRA 260 TMP/TMP (MAIN-LOCAL)
GRA 190 TMP/TMP (LOCAL-SCP)
GRA 210 TMP/TMP (MAIN-SCP)
GRA 380 TMP/TMP (MAIN - PA-A)
GRA 150 TMP/TMP (MAIN-TUNER)
GRA 150 TMP/TMP (PA-A - TUNER)
GRA 70 TMP/<3> (TUNER - ANT-2)
GRA 70 TMP/<3> (TUNER - ANT-1)
The following procedures cover adjustments that are
not normally required once the transceiver has left
the factory. However, If a problem occurs during
normal operation due to component failure; realignment may be required after the faulty components
have been replaced.
We recommend that authorized Vertex Standard
Technicians, who are experienced with the circuitry
and fully equipped to repair and align our products,
perform repairs. If a fault is suspected, contact the
selling dealer for instructions regarding repair. Authorized Vertex Standard Technicians have the latest information to align all circuits and make complete performance checks to ensure compliance with
factory specifications after repairs.
Those who do undertake any of the following alignments are cautioned and proceed at their own risk.
Problems caused by unauthorized attempts at realignment are not covered by the warranty policy.
Vertex Standard must reserve the right to change
circuits and alignment procedures in the interest of
improved performance, without notifying owners.
Under no circumstances should any alignment be
attempted unless the normal functions and operation of the transceiver are clearly understood, the
cause of the malfunction has been clearly identified
and all faulty components replaced. The need for
realignment should be determined to be absolutely
necessary.
The following test equipment (and a thorough familiarity with its correct use) is necessary for correct
realignment. Most steps do not require all of the
equipment listed. The interactions of some adjustments may require that more complex adjustments
be performed in a sequence. Do not attempt to perform only a single step unless it is clearly isolated
electrically from all other steps. Have all test equipment ready before beginning, and follow all of the
steps in a section in the order they are presented.
Required Test Equipment
RF Signal Generator
AF Signal Generator
Spectrum Analyzer good to at least 1 GHz.
Frequency Counter
SINAD Meter
RF Millivoltmeter
Electronic Load
Digital DC Voltmeter (high-Z, 1 M-Ohm/V)
DC Voltmeter
DC Ammeter (20 A)
Ohmmeter
DMU-2000 Data Management Unit
50-Ohm Dummy Load (100 watts)
In-Line Wattmeter (100 watts, 50-Ohm)
Linear Detector
RF Coupler
4-Ohm AF Dummy Load (3 watts)
1/4-inch 3-contant Plug
Alignment Preparation & Precautions
A 50-ohm RF Dummy load and in-line wattmeter
must be connected to the “ANT 1” jack in all procedures that call for transmission, except where specified otherwise. Correct alignment is not possible with
an antenna.
After completing one step, read the following step
to determine whether the same test equipment will
be required. If not, remove the unneeded test equipment before proceeding. (except the dummy load
and wattmeter).
Correct alignment requires that the ambient temperature be maintained constant between 68 °F ~ 86 °F
(20 °C ~ 30 °C). When the transceiver is brought into
the shop from a hot or cold environment, it should
be allowed time to come to room temperature before alignment. Also, the test equipment must be
thoroughly warmed up before beginning.
Whenever possible, alignments should be made with
oscillator shields and circuit boards firmly affixed in
place.
Important Notice
Do not adjust the alignment menus that are not
mentioned in this manual.
FT-950 Technical Supplement
Note: Signal levels in dB referred to in this proce-
dure are based on 0 dBµ = 0.5 µV (closed circuit).
ALIGNMENT-1
Alignment
VDD Meter Adjustment
Connect the DC voltmeter to pin 6 of J5402 on
the PA-A Unit.
Switch the external display to “SWR Monitor”
page.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the
alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “B-01 vdd”.
Press the [ENT] key, then rotate the [CLAR(VFO-
B)] knob so that the VDD meter reading is the
same as that on the DC voltmeter.
Rotate the Main Tuning Dial knob to select the
alignment parameter “B-02 vdd”.
Rotate the [CLAR(VFO-B)] knob so that the VDD
meter (on the external display) reading is same
as that on the DC voltmeter.
Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the alignment mode.
Pin 6 of J5402
TP5032
ALIGNMENT-2
PA-A UNIT ALIGNMENT POINTS
FT-950 Technical Supplement
Alignment
2nd Local Oscillator Adjustment
Disconnect the coaxial cable from J4005 on the
LOCAL Unit, then connect the Frequency counter
to J4005.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the
alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “C-08 FrE”.
Rotate the [CLAR(VFO-B)] knob so that the Fre-
quency counter reading is “69.000 MHz”.
Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the alignment mode.
Disconnect the Frequency counter from J4005,
then connect the RF millivoltmeter to J4005.
Adjust T4003, T4004, and T4005 on the LOCAL
Unit for maximum deflection on the RF
millivoltmeter (more than 0 dBm).
Disconnect the RF millivoltmeter from J4005, then
re-connect the coaxial cable to J4005.
PLL Adjustment
Connect the Digital DC voltmeter (high-Z) to
TP4005 on the LOCAL Unit.
Disconnect the coaxial cable from J4002 on the
LOCAL Unit, then connect the RF millivoltmeter
to J4002.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the
alignment mode.
Referring to the table below, select the appropri-
ate “Alignment Parameter” using the Main Tuning Dial knob per the chart below, and adjust the
listed components for the required voltage, or
confirm that the correct voltage is present on each
alignment parameter.
Disconnect the RF millivoltmeter from J4002, then
re-connect the coaxial cable to J4002.
Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the alignment mode.
ADJUST / CONFIRM
Adjust TC4004
Confirm
Adjust TC4003
Confirm
Adjust TC4002
Confirm
Adjust TC4001
Confirm
DC VOLTMETER
5.0 V ±0.1 V
At least 0.7 V
5.0 V ±0.1 V
At least 0.7 V
5.0 V ±0.1 V
At least 0.7 V
5.0 V ±0.1 V
At least 0.7 V
RF MILLIVOLTMETER
At least –3 dBm
At least –3 dBm
At least –3 dBm
At least –3 dBm
At least –3 dBm
At least –3 dBm
At least –3 dBm
At least –3 dBm
J4002
TC4001
TC4002
TC4003
TC4004
FT-950 Technical Supplement
TP4005
T4003
T4004
J4005
T4005
LOCAL UNIT ALIGNMENT POINTS
ALIGNMENT-3
Alignment
Main Receiver Adjustment
1st Local Oscillator Adjustment
Set the following controls as indicated:
[ANT 1-2] button: ANT 1
[IPO] button: AMP1
[ATT] button: OFF
[µ-TUNE] button: THRU
[R.FLT] button: AUTO
[AGC] button: AUTO
[RF GAIN] knob: Fully clockwise
[MODE] button: CW
Connect the RF millivoltmeter to TP1049 on the
MAIN Unit.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the
alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “C-03 L7”.
Rotate the [CLAR(VFO-B)] knob so that the RF
millivoltmeter reading is “1.0 Vrms ±0.05 V”, then
press the [ENT] key.
Rotate the Main Tuning Dial knob to select the
alignment parameter “C-04 L14”.
Rotate the [CLAR(VFO-B)] knob so that the RF
millivoltmeter reading is “0.6 Vrms ±0.05 V”, then
press the [ENT] key.
Rotate the Main Tuning Dial knob to select the
alignment parameter “C-07 L50”.
Rotate the [CLAR(VFO-B)] knob so that the RF
millivoltmeter reading is “0.7 Vrms ±0.05 V”, then
press the [ENT] key.
Press and hold in the [MENU] button for one sec-
ond to save the new settings and exit the alignment mode.
TP1055
T1028
TP1063
T1034
T1022
T1027
T1023
T1011
TP1049
J1028
T1019
T1026
T1025
T1024
T1033
T1032
T1031
TP1035
T1037
T1030
TP1059
T1029
ALIGNMENT-4
MAIN UNIT(RECEIVER SECTION
)
A
LIGNMENT POINTS
FT-950 Technical Supplement
Alignment
2nd/3rd
Connect the RF millivoltmeter to TP1063 on the
Adjust T1034 on the MAIN Unit for maximum
Connect the RF millivoltmeter to TP1055 on the
Adjust T1028 on the MAIN Unit for maximum
IF Transformer Adjustment
Set the VFO-A frequency to 14.200 MHz in the
Set the following controls as indicated:
Connect the AF millivoltmeter and 4 Ohm
Connect the RF Signal Generator to the “ANT 1”
Adjust T1025, T1032, T1037, T1030, T1027, and
Note: 1) If the S-meter deflects while adjusting, reduce the RF Signal Generator output so that the Smeter does not deflect.
2) There are two peak points in the T1025 and T1032
adjustments. Adjust T1025 and T1032 so the cores
are in the upper part of the coil.
Local Level Adjustment
MAIN Unit.
deflection on the RF millivoltmeter (more than
+8 dBm).
MAIN Unit.
deflection on the RF millivoltmeter (more than 0
dBm).
CW mode.
[ANT 1-2] button: ANT 1
[IPO] button: AMP1
[ATT] button: OFF
[µ-TUNE] button: THRU
[R.FLT] button: 6 kHz
[AGC] button: AUTO
[RF GAIN] knob: Fully clockwise
dummy load to the EXT SP jack.
jack, then set the output level to 0 dBµ at the
14.200 MHz.
T1022 on the MAIN Unit in succession several
times for maximum deflection on the AF
millivoltmeter.
MCF Adjustment (1)
Set the VFO-A frequency to 14.200 MHz in the
CW mode.
Set the following controls as indicated:
[ANT 1-2] button: ANT 1
[IPO] button: AMP1
[ATT] button: OFF
[µ-TUNE] button: THRU
[R.FLT] button: 3 kHz
[AGC] button: AUTO
[RF GAIN] knob: Fully clockwise
Connect the AF millivoltmeter and 4 Ohm
dummy load to the EXT SP jack.
Connect the RF Signal Generator to the “ANT 1”
jack, then set the output level to 0 dBµ at the
14.200 MHz.
Adjust T1026 and T1033 on the MAIN Unit in
succession several times for maximum deflection
on the AF millivoltmeter.
Note: 1) If the S-meter deflects while adjusting, reduce the RF Signal Generator output so that the Smeter does not deflect.
2) There are two peak points in the T1026 and T1033
adjustments. Adjust T1026 and T1033 so the cores
are in the upper part of the coil.
IF Trap Adjustment
Set the VFO-A frequency to 50.000 MHz in the
CW mode.
Set the following controls as indicated:
[ANT 1-2] button: ANT 1
[IPO] button: AMP1
[ATT] button: OFF
[µ-TUNE] button: THRU
[R.FLT] button: AUTO
[AGC] button: AUTO
[RF GAIN] knob: Fully clockwise
Connect the AF millivoltmeter and 4 Ohm
dummy load to the EXT SP jack.
Connect the RF Signal Generator to the “ANT 1”
jack, then set the output level to +60 ~ +90 dBµ at
the 69.450 MHz.
Adjust T1011 on the MAIN Unit for minimum
deflection on the AF millivoltmeter.
Note: If the S-meter deflects while adjusting, reduce
the RF Signal Generator output so that the S-meter
does not deflect.
FT-950 Technical Supplement
ALIGNMENT-5
Alignment
MCF Adjustment (2)
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the
alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “G-03 FnG”.
Rotate the [CLAR(VFO-B)] knob so that the Mult-
Display Window shows “80”.
Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the alignment mode.
Set the VFO-A frequency to 50.000 MHz in the
FM mode.
Set the following controls as indicated:
[ANT 1-2] button: ANT 1
[IPO] button: AMP2
[ATT] button: OFF
[µ-TUNE] button: THRU
[R.FLT] button: 15 kHz
[AGC] button: AUTO
[RF GAIN] knob: Fully clockwise
Connect the SINAD meter and 4 Ohm dummy
load to the EXT SP jack.
Connect the RF Signal Generator to the “ANT 1”
jack, then set the output level to –10 ~ 0 dBµ at
the 50.000 MHz with ±3.5 kHz deviation FM
modulation of a 1 kHz audio signal.
Adjust T1024 and T1031 on the MAIN Unit in
succession several times for maximum deflection
on the SINAD meter.
Adjust T1022 on the MAIN Unit in succession
several times for maximum deflection on the
SINAD meter.
Note: Do not adjust T1022 more than 45 degrees
rotation.
Noise Blanker Circuit Adjustment
Set the VFO-A frequency to 14.200 MHz in the
CW mode.
Set the following controls as indicated:
[ANT 1-2] button: ANT 1
[IPO] button: AMP1
[ATT] button: OFF
[µ-TUNE] button: THRU
[R.FLT] button: AUTO
[AGC] button: AUTO
[NB] button: ON (for short-duration pulse noise)
[RF GAIN] knob: Fully clockwise
Connect the Digital DC voltmeter (high-Z) to
TP1059 on the MAIN Unit.
Connect the RF Signal Generator to the “ANT 1”
jack, then set the output level to 30 dBµ at 14.200
MHz.
Adjust T1029 and T1023 on the MAIN Unit for
minimum deflection on the DC voltmeter.
Turn the NB to “OFF” by pressing the [NB] but-
ton.
Scope Circuit Adjustment
Set the VFO-A frequency to 14.200 MHz in the
CW mode.
Set the following controls as indicated:
[ANT 1-2] button: ANT 1
[IPO] button: AMP1
[ATT] button: OFF
[µ-TUNE] button: THRU
[R.FLT] button: AUTO
[AGC] button: AUTO
[RF GAIN] knob: Fully clockwise
Disconnect the coaxial cable from J1028 on the
MAIN Unit, then connect the RF millivoltmeter
to J1028.
Connect the RF Signal Generator to the “ANT 1”
jack, then set the output level to 80 dBµ at 14.200
MHz.
Adjust T1019 on the MAIN Unit for maximum
deflection on the RF millivoltmeter.
Disconnect the RF millivoltmeter from J1028, then
re-connect the coaxial cable to J1028.
ALIGNMENT-6
FT-950 Technical Supplement
Alignment
RF AGC Adjustment
Set the following controls as indicated:
[ANT 1-2] button: ANT 1
[IPO] button: AMP1
[ATT] button: OFF
[µ-TUNE] button: THRU
[R.FLT] button: 6 kHz
[AGC] button: AUTO
[RF GAIN] knob: Fully clockwise
[MODE] button: CW
Connect the Digital DC voltmeter (high-Z) to
TP1035 on the MAIN Unit.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the
alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “D-05 rGc”.
Note the Digital DC voltmeter reading (with no
receive signal).
Rotate the [CLAR(VFO-B)] knob counter-clock-
wise just to the point where the Digital DC voltmeter reading is 0.01 V less than the voltage noted
in the previous step.
Rotate the [CLAR(VFO-B)] knob clockwise just
to the point where the Digital DC voltmeter reading is the same as the previously noted voltage,
then press the [ENT] key.
Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the alignment mode.
IF Gain Adjustment
Set the VFO-A frequency to 1.900 MHz in the CW
mode.
Set the following controls as indicated:
[ANT 1-2] button: ANT 1
[IPO] button: AMP1
[ATT] button: OFF
[µ-TUNE] button: THRU
[R.FLT] button: 6 kHz
[AGC] button: AUTO
[RF GAIN] knob: Fully clockwise
[MODE] button: CW
Set the CW PITCH frequency to “700 Hz” via
Menu item “045 A1A PITCH”.
Connect the AF millivoltmeter and 4 Ohm
dummy load to the EXT SP jack.
Connect the RF Signal Generator to the “ANT 1”
jack, then set the output level to 36 dBµ at 1.900
MHz.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the
alignment mode.
Adjust the Main [AF GAIN] knob so that the AF
millivoltmeter reading is “0 dB.”
Refer to the chart below and select the appropri-
ate “Alignment Parameter” using the Main Tuning Dial knob per the chart below, then set the
RF Signal Generator output to each frequency &
level, and adjust the [CLAR(VFO-B)] knob for the
corresponding AC millivoltmeter reading at each
frequency.
–1.5 dB (±0.5 dB)
–1.5 dB (±0.5 dB)
–1.5 dB (±0.5 dB)
–1.5 dB (±0.5 dB)
–1.5 dB (±0.5 dB)
–1.5 dB (±0.5 dB)
–1.5 dB (±0.5 dB)
–1.5 dB (±0.5 dB)
–1.5 dB (±0.5 dB)
–1.5 dB (±0.5 dB)
Press and hold in the [MENU] button for one sec-
ond to save the new settings and exit the alignment mode.
FT-950 Technical Supplement
ALIGNMENT-7
Alignment
S-meter Adjustment
Set the VFO-A frequency to 14.200 MHz in the
CW mode.
Set the following controls as indicated:
[ANT 1-2] button: ANT 1
[IPO] button: AMP1
[ATT] button: OFF
[µ-TUNE] button: THRU
[R.FLT] button: 6 kHz
[AGC] button: AUTO
[RF GAIN] knob: Fully clockwise
Connect the RF Signal Generator to the “ANT 1”
jack, then set the frequency to 14.200 MHz.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the
alignment mode.
Refer to the chart below and select the appropri-
ate “Alignment Parameter” using the Main Tuning Dial knob. Set the RF Signal Generator output to each level, and adjust the [CLAR(VFO-B)]
knob for the corresponding S-meter reading.
Press the [ENT] key to save the new setting at
each level.
Press the [PTT] button
Rotate the [CLAR(VFO-B)] knob
Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button
Rotate the [CLAR(VFO-B)] knob
Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button
Rotate the [CLAR(VFO-B)] knob
Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button
Rotate the [CLAR(VFO-B)] knob
Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button
Rotate the [CLAR(VFO-B)] knob
Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button
Rotate the [CLAR(VFO-B)] knob
Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button
Rotate the [CLAR(VFO-B)] knob
Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button
Rotate the [CLAR(VFO-B)] knob
Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button
Rotate the [CLAR(VFO-B)] knob
Rotate the [CLAR(VFO-B)] knob
[
PTT] button
Rotate the [CLAR(VFO-B)] knob
Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button
Rotate the [CLAR(VFO-B)] knob
Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button
Rotate the [CLAR(VFO-B)] knob
Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button
Rotate the [CLAR(VFO-B)] knob
Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button
Rotate the [CLAR(VFO-B)] knob
Rotate the [CLAR(VFO-B)] knob
Press the [PTT] button
Rotate the [CLAR(VFO-B)] knob
POWER METER
(
)
A
DJUSTTO
101 W (+5 W / –1 W
50 W (+5 W / –0 W
20 W (+2 W / –0 W
10 W (+1 W / –0 W
5 W (+1 W / –0 W
101 W (+5 W / –1 W
50 W (+5 W / –0 W
20 W (+2 W / –0 W
10 W (+1 W / –0 W
5 W (+1 W / –0 W
101 W (+5 W / –1 W
50 W (+5 W / –0 W
20 W (+2 W / –0 W
10 W (+1 W / –0 W
5 W (+1 W / –0 W
)
–
–
)
–
–
)
–
–
)
–
–
)
–
–
)
–
–
)
–
–
)
–
–
)
–
–
)
–
–
)
–
–
)
–
–
)
–
–
)
–
–
)
–
–
ALIGNMENT-13
ALC METER
(
)
A
DJUSTTO
–
–
Turns on 16 dots
–
–
Turns on 16 dots
–
–
Turns on 16 dots
–
–
Turns on 16 dots
–
–
Turns on 13 dots
–
–
Turns on 16 dots
–
–
Turns on 16 dots
–
–
Turns on 16 dots
–
–
Turns on 16 dots
–
–
Turns on 13 dots
–
–
Turns on 16 dots
–
–
Turns on 16 dots
–
–
Turns on 16 dots
–
–
Turns on 16 dots
–
–
Turns on 13 dots
Alignment
Perform the same procedures for the Alignment
Menus “J-04 P50” through “J-15 P05”, “K-01 P1h”
through “K-15 P05”, “L-01 P1h” through “L-15
P05” per the chart at the right.
Press the [ENT] key to save the new setting at 1.8
MHz, 3.5 MHz, 7 MHz, and 10 MHz Bands.
Perform the same procedures for the Alignment
Menus “N-01 P1h” through “N-15 P05” per the
chart at the right.
Press the [ENT] key to save the new setting at 14
MHz, 18 MHz, and 21 MHz Bands.
Perform the same procedures for the Alignment
Menus “Q-01 P1h” through “Q-15 P05” per the
chart at the right.
Press the [ENT] key to save the new setting at 24
MHz and 28 MHz Bands.
Perform the same procedures for the Alignment
Menus “S-01 P1h” through “S-15 P05” per the
chart below.
Press and hold in the [MENU] button for one sec-
ond to save the new settings and exit the alignment mode.
AM-TXG Adjustment
Connect the 50-Ohm Dummy Load and Wattme-
ter to the “ANT 1” jack.
Set the value of Menu item “111 TGEN TX PWR”
to “100”, and Menu item “112 TGEN AM CAR”
to “100”.
Set the VFO-A frequency to 14.200 MHz in the
AM mode.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the
alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “T-02 tCA.”
Rotate the [CLAR(VFO-B)] knob so that the
Multi-Display Window shows “0”.
Press the PTT button without microphone input,
then rotate the [CLAR(VFO-B)] knob for 70 W
(±5 W) on the Wattmeter.
Release the PTT button.
Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the alignment mode.
REV-ALC Adjustment
Disconnect the test equipment from the “ANT 1”
jack.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the
alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “U-01 rAC.”
Press the PTT button, then rotate the
[CLAR(VFO-B)] knob so that the PO meter turns
on 14 dots.
Release the PTT button, then press the [ENT] key.
Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the alignment mode.
ALIGNMENT-14
FT-950 Technical Supplement
Alignment
ID Meter Adjustment
Choose one of the adjustment methods described below, according to the equipment you have available. If you
perform adjustment method (2) Using a DC Ammeter, complete the transmit adjustments on ALIGNMENT
page 9 through 14.
1) Using an Electronic Load
Remove the jumper wire that is connected be-
tween TP5031 and TP5032 on the PA-A Unit, then
connect the Electronic Load to TP5032 and GND.
Set the VFO-A frequency to 14.200 MHz in the
CW mode.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the
alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “X-01 Idd”.
Press the PTT button, then adjust the Electronic
Load to “10 A”.
Press the [ENT] key, then release the PTT button.
Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the alignment mode.
2) Using a DC Ammeter
Connect the 50-Ohm Dummy Load and Wattme-
ter to the “ANT 1” jack.
Remove the jumper wire that is connected be-
tween TP5031 and TP5032 on the PA-A Unit, then
connect the DC ammeter (15-A range) between
TP5031 and TP5032.
Set the VFO-A frequency to 14.200 MHz in the
CW mode.
Press the PTT button, set the DC ammeter for 10
A via Menu item “111 TGEN TX PWR”.
Release the PTT button, then press and hold in
the [MENU] button for one second to save the
new setting and exit the menu mode.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the
alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “X-01 Idd”.
Press the PTT button, confirm the DC ammeter
readig is 10 A.
Press the [ENT] key, then release the PTT button.
Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the alignment mode.
FT-950 Technical Supplement
TP5032
TP5031
PA-A UNIT ALIGNMENT POINTS
ALIGNMENT-15
Alignment
FM MAX Deviation Adjustment
Connect the Dummy Load, Wattmeter, and De-
viation Meter to the “ANT 1” Jack.
Set the VFO-A frequency to 28.700 MHz in the
FM mode.
Set the value of Menu item “056 F3E MIC ” to
“50”.
Connect the Audio Generator to
pin 8 of the MIC jack (pin 7:
GND), then set the output level
to 2 mV @1 kHz.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the
alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “V-02 F45”.
Press the PTT button, then rotate the
[CLAR(VFO-B)] knob for 4.5 kHz (±0.2 kHz) on
the Deviation Meter.
Release the PTT button.
Press the [NAR] button to set the VFO-A operat-
ing mode to the FM-N mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “V-03 F23”.
Press the PTT button, then rotate the
[CLAR(VFO-B)] knob for 2.25 kHz (±0.15 kHz)
on the Deviation Meter.
Release the PTT button.
Press and hold in the [MENU] button for one sec-
ond to save the new setting and exit the alignment mode.
MIC IN
MIC GND
SWR Meter Adjustment
Set the VFO-A frequency to 28.700 MHz in the
CW mode.
Connect the 50-Ohm Dummy Load and Wattme-
ter to the “ANT 1” Jack.
Connect the 1/4-inch 3-contact Plug to the KEY
jack (but, without the key).
Set the Multi Function Meter to “SWR” by press-
ing the [METER] button.
Disconnect the 3-pin plug from J1014 on the
MAIN Unit, then apply a 2.75 V DC voltage to
pin 2 of J1014, and 1.00 V DC to pin 3 of J1014.
Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the
alignment mode.
Rotate the Main Tuning Dial knob to select the
alignment parameter “W-03 S30.”
Press the [MOX] button, then rotate the
[CLAR(VFO-B)] knob so that the SWR meter (on
the front panel) reading is “3.0”. The SWR meter
reading (3.0) is broad (few points). Therefore, set
the [CLAR(VFO-B)] knob to the center of this
broad range.
Release the [MOX] button.
Apply a 2.96 V DC voltage to pin 2 of J1014, and
1.00 V DC to pin 3 of J1014.
Rotate the Main Tuning Dial knob to select the
alignment parameter “W-06 S30.”
Press the [MOX] button, then rotate the
[CLAR(VFO-B)] knob so that the SWR meter (on
the front panel) reading is “3.0.” The SWR meter
reading (3.0) is broad (few points). Therefore, set
the [CLAR(VFO-B)] knob to the center of this
broad range.
Release the [MOX] button.
Apply a 3.81 V DC voltage to pin 2 of J1014, and
1.00 V DC to pin 3 of J1014.
Rotate the Main Tuning Dial knob to select the
alignment parameter “W-09 S30.”
Press the [MOX] button, then rotate the
[CLAR(VFO-B)] knob so that the SWR meter (on
the front panel) reading is “3.0.” The SWR meter
reading (3.0) is broad (few points). Therefore, set
the [CLAR(VFO-B)] knob to the center of this
broad range.
Release the [MOX]button.
Press and hold in the [MENU] button for 2 sec-
onds to save the new settings and exit the alignment mode.
Re-connect the 3-pin plug to J1014 on the MAIN
Unit.
ALIGNMENT-16
FT-950 Technical Supplement