The unit is housed in a 4000 series module, has a built in door open relay
and can control up to 99 proximity keys. With the addition of a 12V ac/dc
power supply a surface or flush mounting support and electric door release the unit provides a complete access control system.
OPERATION
• The user offers the key(fob or ca rd format) close to the reader
• If the key has been programmed, the unit will emit a beep, the LED will
change from yellow to green for about one second and the built in relay
will energise.
• If the key has not been progra mmed, the unit will emit a beep, the LED
will change from yellow to red for about one second and the key will be
ignored. After 5 attempts to use a non programmed key, the led will
change to red flashing for about 60 seconds: during this time the unit will
not accept any keys.
PROGRAMMING
Programming is carried out by the 4 buttons loca ted on the back of the
module, LEDs and acoustic signals are provided to assist with the programming. In “stand-by” the buttons are locked, these must be un locked
by entering the unlock sequence before any prog ramming can be undertaken.
UNLOCK BUTTONS SBLOCCO TASTI
The programming buttons are locked to prevent unauthorised or accidental operation. The unlock sequence is a combination of 4 button activations: the available buttons are “tens”, “units”, “store” an d “delete”, the
same button can be operated up-to a max of 4 times as the unlock sequence.
Unlock button procedure:
1. From “stand-by” (green and red LEDs on) enter the unlock se-
2. If the entered sequence is wrong, the unit will emit a beep and the
3. With the two yellow LEDs switched on the unit is no w waiting for a
4. When the unit emits 2 beeps and the 4 LEDs are switched on this
The unit will automatically relock if no operations are detected within 20
seconds of being unlocked.
To exit programming mode before the 20 second s timeout expires,
hold the Delete button down for three seconds. The gre en Store LED
will illuminate for 1 second and the module will bee p once. The module will then have exited programming m ode.
PrtCode:66250400 Pag.1/8
INSTALLATION INSTRUCTION
quence by programming the relevant buttons, (factory settings when
first used 4 x operation of the “tens” button).
green and red LEDs will remain on (restart from point 1). When the
correct sequence is entered, the green and red LEDs are switched
off and the two yellow LEDs are switched on confirming the correct
sequence.
new unlock sequence or confirmation of the previous sequence. If an
unlock sequence (new or old) is not entered within 15 seconds the
unit will revert to “stand-by” (restart from point 1).
indicates that the buttons are unlocked (“programming mode”) and
the following operations may now be performed.
a. Key storing
b. Key deletion
c. Key reading
d. S et the relay time
Stand-alone proximity keys reader
Lettore chiavi di prossimità stand-alone
ART.4850 LETTORE CHIAVI DI PROSSIMITÀ STAND-ALONE
Ha dimensioni di un modulo della serie 4000, incorpora il relè apri-porta e
gestisce fino a 99 chiavi di prossimità. In abbinamento ad un alimentatore
12/24Vac/dc ed al relativo supporto da incasso o superficie permette di
realizzare un completo sistema di controllo accessi.
FUNZIONAMENTO
• L’utente avvicina la propria chiave di prossimità (formato tag o card) al
• Se la chiave viene letta correttamente, l’unità emette un bip, il LED cen-
• Se la chiave non è programmata, l’unità emette un bip, il LED centrale
PROGRAMMAZIONE
La programmazione viene eseguita tramite i 4 tasti presenti sul retro del
modulo con l’ausilio dei relativi LED e di segnalazioni acustiche. In condizioni normali (stand-by) i tasti sul retro del modulo sono in blocco, prim a di
procedere ad una qualunque operazione di prog rammazione è necessario
sbloccarli digitando l’opportuna sequenza.
Il blocco dei tasti funge da protezione contro eventuali manomiss ioni o
pressioni accidentali degli stessi. La sequenza di sblocco è costi tuita da
una combinazione di 4 pressioni scegliendo tra i tasti “tens”, “units”, “sto-re” e “delete”: lo stesso tasto può essere presente più volte (max 4) nella
combinazione per cui una sequenza di sblocco pu ò essere composta anche da 4 pressioni di uno solo dei tasti tra quelli sopra menzionati.
Procedura di sblocco tasti:
1. Dall a condizione di “stand-by” (LED verde “store” e LED rosso “dele-
2. Se la sequenza inserita è errata, l’unità lo segnala con un bip ed i
3. I LED giall i sono accesi e l’unità è in attesa di una nuova sequenza di
4. L’emissione di 2 bip e l’accensione dei 4 LED (2 gial li, il verde ed il
In assenza di operazioni i tasti si bloccheranno automaticamente dopo
circa 20 secondi.
Per uscire dal modo programmazione prima che scadano i 20 secondi di “timeout”, premere per circa 3 secondi il pulsante delete: il LED
store si accende per un secondo circa e l’unità emette un beep confermando l’uscita dal modo programmazione.
Power on the unit
First time factory
sequence
Is Right ?
old one
YES
Reading
Key
default is 4
times the "tens"
button
The unit emit
two beep, red
and green LEDs
off, yellow LEDs
on
The unit emit 2
beep the 4 LEDs
are switched on
Rela y
Time
Programming
19/10/2006Rev.1.1
Key
Dele tio n
Enter the unlock
NO
Enter a new
sequence or the
Buttons are
unlocked one of
the following
operations can
be performed
Key
Storing
lettore nell’apposita zona centrale;
trale passa da giallo a verde per circa un secondo e il relè incorporato si
attiva per il tempo programmato;
passa da giallo a rosso per circa un secondo e l a chiave viene ignorata.
Dopo cinque tentativi di utilizzo di una chiave non programmata, il LED
frontale diventa rosso lampeggiante per circa 60 secondi duran te i quali
l’unità non è abilitata alla lettura delle chiavi.
te” accesi) inserire la sequenza di sblocco premendo gli opportuni
tasti. In caso di prima programmazione, la sequenza impostata di
fabbrica è 4 volte il tasto “tens”;
LED rosso e verde restano accesi (ripartire dal punto 1) altrimenti
vengono emessi due bip, i LED rosso e verde si spengono e si ac cendono quelli gialli a segnalare la corretta sequenza.
sblocco. Per procedere con lo sblocco dei tasti digitare una nuo va
sequenza o una uguale a quella precedente. Se la digitazione della
nuova sequenza si interrompe per più di 15 s econdi l’unità torna in
“stand-by” (punto 1);
rosso) indicano che i tasti sono sbloccati (“modo programmazione”)
ed è possibile accedere ad una delle seguenti operazioni:
a. Memorizzazione di una chiave;
b. Cancellazione di una chiave;
c. Lettura di una chiave.
d. Programmazione del tempo relè
ISTRUZIONI D’INSTALLAZIONE
Alimentare L'unità
In caso di prima
Digitare l a
sbl o c c o
Sequenza
Corrett a ?
precedente
operazioni
SI
Lettura
Chia ve
programmazione
premere 4 volte
"TENS"
L'unità emette
due bip, LED
rosso e verde
spenti, LED
gialli accesi
L'unità emette
due bip, i 4 LED
sono accesi
Prog.
Tempo
Relè
Canc.
Chia ve
sequenza di
NO
Digitare una
nuova sequenza
o ripetere la
I tasti sono sbloccati
ed è possibile passare
ad una delle seguenti
Mem.
Chia ve
KEY STORING MEMORIZZAZIONE CHIAVE
All keys (tags or fobs) have a unique number these are stored within the
unit (in locations 1 to 99). A stored key when read will acti vate the unit’s
built-in relay.
Key storing procedure:
1. Unlock the buttons as described above to enter the “pr ogramming
mode” (yellow, green & red LEDs switched on).
2. Press the “store” button, green LED is switched on while all other
LEDs are off. The unit is waiting for a code (1 to 99).
3. Enter the code (1 to 99) using the “units” and “tens” buttons. Each
button operation is confirmed by a beep and the corresponding LED
flashing, eg, to enter 45, press the “tens” butto n 4 times then the
“units” button 5 times.
4. Press the “store” button to confirm.
a. If the chosen code is already in use, the unit will emit a beep
and the red LED will switch on for 1 second. Rest art from point
3.
b. If the chosen code is availa ble, the green LED will flash, the unit
is waiting for a proximity key to store.
5. Offer the new key close to the centre of the front side of the unit,
when the key has been read the unit reverts to “programming mode” (4 LEDs switched on) and is now waiting for a new programming operation.
Unlock the buttons if
requested
Pr ess t he stor e
Enter the code by
tens & units buttons
I.E. 45 = press
4 times tens
5 times units
Pr ess t he stor e
Code Engaged
Bring the key close
to the reader
Key Read, the
system goes back to
KEY DELETION CANCELLAZIONE CHIAVE
A lost, stolen or misplaced key can be deleted from the unit allowing another key to be programmed into the same deleted key position.
Key deletion procedure:
1. If required unlock the programming buttons as identified earlier to
enter the “programming mode” (yellow, green & re d LEDs switched
on).
2. Press the “delete” button, the red LED is switched on, all other LEDs
are off
3. Enter the code for the key to be deleted (1 to 99) using the “units”
and “tens” buttons. E ach button operation is confirmed with a beep
and the corresponding LED flashing, eg, to enter 45, press the
“tens” button 4 times then the “units” button 5 times.
4. Press “store” to confirm deletion. The red LED is switched off, the
green LED is switched on for about 2 seconds and the unit emits a
beep before reverting into “programming mode” (4 LEDs switched
on).
prog. mode
Unlock the buttons
if required
Press the delete
Enter the code by
tens & units buttons
I.E. 45 = press
4 times tens
5 times units
Press the store
Key deleted, the
system goes in
prog. mode
PrtCode:66250400 Pag.2/8
Button
Button
Yet ?
button
button
YES
NO
4 LEDs switched
ON
Only green LED
switched on, the
unit is waiting
for a code
One beep is
emitted red LED
goes on for
about 1 second
Green LED starts
flashing the unit
wait for a key
4 LEDs
switched
on
4 LEDs ON
red LED on, the
unit wait for a
code
red LED off,
green LED on
about 2 seconds
plus beep
La “memorizzazione chiave” consiste nell’abbinare un codice (1..99) ad
una chiave di prossimità. La chiave memorizzata permetterà (quando letta) di attivare il relè incorporato nel modulo.
Procedura di memorizzazione chiave:
1. Se necessario sbloccare i tasti seguendo la relativa procedura per
entrare nel “modo programmazione” (LED gialli, verde e rosso);
2. Premere il tasto “store”, resta acce so il LED verde mentre gli altri si
spengono. L’unità è in attesa di un codice;
3. Digitare il codice (1..99) utilizzando i tasti “units” (unità) e “tens” ( decine): scegliere un codice e premere il tasto “units” tante volte quante sono le unità del codice scelto ed il tasto “tens” tante volte quante
sono le decine. Ogni pressione è confermata da un bip e
dall’accensione del relativo LED. Volendo programmare il codice 45
è necessario premere “units” 5 volte e “tens” 4 vo lte;
4. P remere il tasto “store”:
a. Se il codice scelto è occ upato, l’unità emette un bip, si accende
per circa un secondo il LED rosso e la program mazione torna
all’inizio del punto 3;
b. Se il codice scelto è disponibile, il LED verde inizia a lampeggia -
re e l’unità è in attesa della chiave da memorizzare.
5. Avvicinare la chiave al lettore (zona central e nella parte frontale del
modulo) per memorizzarla. Letta la chiave l’unità torna nel “modo programmazione” (LED gialli, verde e rosso accesi) in attesa di una
nuova operazione.
La cancellazione della chiave elimina l’abbinamento tra il codice (1..99) e
la chiave di prossimità liberando il codice p er la memorizzazione di
un’altra chiave.
Procedura di cancellazione chiave:
1. Se necessario sbloccare i tasti seguendo la relativa procedura per
entrare nel “modo programmazione” (LED gialli, verde e rosso accesi);
2. Premere il tasto “delete”, il LED rosso resta acceso mentre gli altri si
spengono;
3. Digitare il codice (1..99) della chiave da cancellare utilizzando i tasti
“units” (unità) e “tens” (decine): premere il tasto “units” tante volte
quante sono le unità del codice ed il tasto “tens” tante volte quante
sono le decine. Ogni pressione è confermata da un bip e
dall’accensione del relativo LED. Volendo cancellare il codice 34 è
necessario premere “units” 4 volte e “tens” 3 volte;
4. Premere il tasto “store” per confermare l’operazione: il LED rosso si
spegne, si accende il LED verde per circa 2 secondi e viene emesso
un bip quindi l’unità torna nel “modo programmazione” (LED gialli,
verde e rosso accesi).
Sbloccare i tasti se
ne c e ssar i o
Premere il
pulsante store
Inseri re il codi ce
tramite i tasti tens
e units Es.45 = 4
volte tens, 5 volte
Premere il
pulsante store
Occupato ?
Avvici nare la
chiave al lettore
Chiave letta il
sistema torna nel
modo prog.
Sbloccare i tasti se
necessario
Premere il
pulsante delete
Inseri re il codi ce
tramite i tasti tens
e units Es.45 = 4
volte tens, 5 volte
Premere il
pulsante store
Chiave cancellata
il sistema torna nel
modo prog
19/10/2006Rev.1.1
units
Codi ce
units
Si
NO
Led verde
acceso l'unità
attende un
codice
1 Bip e LED
ro sso a cce so p er
circa 1 secon do
LED verde
lampeggiante
attesa chi ave
LED gialli,
rosso e ve rde
accesi
4 LED accesi
LE D ro sso
acceso l'unità
attende un
codi ce
LE D ro sso
spento, LED
verde acceso per
2 secondi circa +
Bip
KEY READING LETTURA CHIAVE
This allows the code of an unknown key if programmed into the unit to be
identified
Key reading procedure:
1. If required unlock the programming buttons as identified earlier to
enter the “programming mode” (yellow, green & re d LEDs switched
on).
2. Press the “units” and “tens” buttons at the same time, the red an d
green LEDs will be switched off while the yellow LEDs start flashing:
3. Offer the unknown key to the re ader (centre of the front) to allow the
key to be read:
a. If the key is stored, the “te ns” LED will flash for how many tens
are in the code then the “units” LED will flash for how many
units are in the code.
b. I f the key is not stored, the two yellow LEDs will remain
switched on for about 2 seconds.
4. Read a key (stored or not) the t wo yellow LEDs will revert to flashing
waiting for other keys to be read:
5. To exit from the reading mode and go back to “programming mode” (4 LEDs switched on) press the “delete” button or wait for 20
seconds.
Unl ock keys if
req uire d
Press at the same
time the buttons
units and tens
Bring the key close
to the reader
4 LEDs on
Yellow LEDs
flashing
La lettura della chiave consente di leggere il codice associato ad una
chiave di prossimità.
Procedura di lettura della chiave:
1. Se necessario sbloccare i tasti seguendo la relativa procedura per
entrare nel “modo programmazione” (LED gialli, verde e rosso accesi);
2. Premere contemporaneamente i tasti “units” e “tens”, i LED rosso e
verde si spengono mentre i LED gialli iniziano a lampeggiare;
3. A vvicinare la chiave al lettore per leggere il codice abbinato:
a. Se la chiave è programmata, il LED “tens” si accenderà tante
volte quante sono le decine che compongono il codice quindi il
LED “units” si accenderà tante volte quante sono le unità.
b. Se la chiave non è programmata, l’unità lo segnala accendendo
stabilmente per circa 2 secondi entrambi i LED gialli.
4. Letta la chiave (programmata o non) i due LED gialli tornano a lampeggiare in attesa di altre chiavi;
5. Per uscire da questa modalità e tornare al “modo programmazione”
(LED gialli, verde e rosso accesi) premere il tasto “delete” o atten dere 20 secondi circa;
Sbloccare i tasti se
necessario
Premere
contemporaneamente
i tasti units e tens
Avvicinare la
chia ve al l ettore
4 LED accesi
LED gialli
lampeggianti
NoYes
Stored Key ?
4 LEDs ON
green & red
LEDS start
flashing
*
green LED on for
about 1
second+beep
I.E. read code
= 43 - LED tens
4 times on,
LED units 3
times on
Questa programmazione permette di impostare il tempo di attivazione del
relè da 1 a 99 secondi.
Procedura di programmazione tempo relè:
1. Se necessario sbloccare i tasti seguendo la relativa procedura per
entrare nel “modo programmazione” (LED gialli, verde e rosso accesi);
2. Premere contemporaneamente i tasti “store” e “delete” fino a che i
LED rosso e verde iniziano a lampeggiare;
3. Impostare il tempo relè (1..99 secondi) util izzando i tasti “tens” e “u-nits”. Es. per impostare 21 secondi, premere una volta il tasto “units”
e due volte il tasto “tens” (ogni pressione è confermata da un bip e
dall’accensione del relativo LED);
4. Prem ere il tasto “store” per confermare il dato inserito, v iene emesso
un bip ed il LED verde resta acceso per circa un secondo qui ndi
l’unità torna nel “modo programmazione” in attesa di altre operazioni
*Per attivare il funzionamento a commutazione del relè premere 10
volte il pulsante units
19/10/2006Rev.1.1
Yellow LEDs
ON for about
two seconds
To go back to prog.
mode, press delete
button or wait
RELAY TIME PROGRAMMING PROGRAMMAZIONE DEL TEMPO RELÈ
This allows the relay time to be set from 1 to 99 seconds.
Relay time programming:
1. If required unlock the programming buttons as identified earlier to
enter the “programming mode” (yellow, green & re d LEDs switched
on).
2. Press the “store” and “delete” b uttons at the same time until the
red and green LEDs start flashing.
3. Set the relay time (1 to 99 seconds) using the “units” and “ten s”
buttons, eg, to set the relay for 21 seconds, press the ”tens” button
two times and the “units” button once (each time a button is pressed
the unit emits a beep and the associated LED is switched on.
4. Press the “store” button to confirm, a beep is emitted and the g reen
LED is switched on for 1 second the unit will then revert back to
“programming mode” (4 LEDs switched on) waiting for a new programming operation.
about 20 seconds
Unlock the buttons
if required
Press together s tore
and delete buttons
Enter the time by
tens & units but tons
I.E. 21s = press
2 times tens
1 times units
Press the store
button to confirm
The system goes in
programming
mode
*To latch the relay press the units button ten times
PrtCode:66250400 Pag.3/8
NoSi
Memorizzata ?
LED gialli
acc esi per c irca
2 secondi
premere delete o
Sbloccare i tasti se
necessario
Premere insieme
store e delete
Impostare il tempo
tramite units e tens
Es. 21s = 2
pressioni tens e 1
pressione units
Premere store per
confermare
Il sistema torna nel
modo
programmazione
Chi ave
Per tornare al
modo prog.,
attendere 20
sec on di cir ca
Es. codice =
43, tens
lampeggia 4
volte - units
lampeggia 3
volt e
I 4 LED si
accendono
LED verde e
rosso
lampeggianti
*
Bip+LED verde
acceso per circa
1 secondo
Loading...
+ 5 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.