TECNICHAL MANUAL
External riceiver 2 channel, 12/24V
SMR24C2
-Code E002-
|
WARNING!! Before installing, thoroughly read this manual that is an integral
part of the pack
Our products if installed by qualified personnel capable to evaluate risks,
comply with norms UNI EN 12453, EN 12445
The CE mark conforms to European directive
EEC 89/336 + 92/31 + 93/68 D.L. 04/12/1992 N. 476.

LAYOUT CONTROL BOARD
PROG
ON
1 2 3 4
1 2 3 4 5 6 7 8
12/24
AC/DC
WIRING
TERMINAL TIP. DESCRIPTION
1-2 Power input 12/24 Vdc/Vac
5-3Com N.O
N.O. = Contact Normaly Open N.C. = Contact Normaly Close
Current
Manage channel
Manage transimitter
TECHNICAL SPECIFICATIONS
254
Frequency 433.92/868 MHz
2
Fix /Rolling
Sensibility Better than -100dBm
Omologation Conf ETS 300-220/ETS
Da 0 a 70°

OPERATING
The programming of the transmitters is done by pressing the "Prog" button for 2sec,
the buzzer will then issue a first sound pulse, and thereafter each time you press a
button the remote control you will have a sound pulse to indicate a successful store.
The control panel automatically exits the programming mode after 6 seconds of
inactivity (action signaled by two sound pulses) For the use of both relays follow the
indication of OPTION 1
For reset all codes you press "Prog" button for 6 sec, after 2 sec you listen a slow
bip and after 4 sec to fast bip. Now all codes are reseted.
The control panel automatically exits the programming mode after 6 seconds of
inactivity (action signaled by two sound pulses).
SELECT OPTIONS BY DIP-SWITCH
ON
1 2 3 4
DIP 1TX CHANNELS ASSOCIATION\RELAY
ON The first programmed key will be associated with the first channel (relay 1),
the second programmed key will be associated with the same remote control
to the second channel (relay 2). Having to program multiple remote controls
on both channels (relay 1, relay 2), complete the programming of each radio
control (as described above), and only then proceed with the other remote
controls. In case of using a single channel (relay 1) store the remote control
button to be assigned.
OFF The channels will be associated automatically: the first key stored will be
associated with the first channel (relay 1), the second key to the second
channel (relay 2). E 'enough to program the first key, the second will be
recognized automatically.
DIP 2
ON Rolling code
OFF Fixed code
ROLLING CODE / CODE FIXED
DIP 3 ACTIVATION PROGRAMMING BY REMOTE CONTROLS (ECO-R)
ON Enable
OFF Disable
DIP 4
ON The first channel, received the impulse of the TX will keep switching.
OFF The management of the first channel is at pulse
FUNCTION "TOGGLE" EA "PULSE" (relay 1)

The data and images are for guidance only
reserves the right to change at any time characteristics of the products described in its sole discretion,
without notice.
CONTACTS :
Via Circolare p.i.p. 10
AUTOMAZIONE ACCESSI
MADE IN ITALY
65010 Santa Teresa di Spoltore (PE) - ITALY
Tel. 085-4971946 - FAX 085-4973849
www.vdsconsorzio.it - vds@vdsconsorzio.it