ISTRUZIONE D’USOApparecchiatura di comando 1 Motore 380Vac
INSTRUCCIONES DE USOCuadro electronico para 1 motor 380Vac
INSTRUCTION MANUALElectronic control panel for a 380 drive
MODE D’EMPLOIDispositif de commande 1 moteur 380Vac
INSTRUÇ
ÕES DE USOCentral de controle de 1 motor 380Vac
Vac
EURO380 M1
[code E107]
ATTENZIONE!! Prima di effettuare l’installazione, leggere attentamente questo manuale. La
VDS declina ogni responsabilità in caso di non osservanza delle normative vigenti.
¡¡ATTENCIÓN!! Antes de efectuar la instalacion, lea attentamente este manual. La Empresa VDS no se
hace responsable caso de no cumplir las normas vigentes en el pais donde se lleva a cabo la instalación.
WARNING!! Before the installation read carefully this manual. VDS declines any responsability in case of
not fullfill the current normative of the installation country.
ATTENTION!! Avant d’effectuer l’installation, lire attentivement le présent manuel qui fait partie
intégrante de cet emballage. La société VDS décline toute responsabilità en cas de non respect des normes
en viguer.
ATENÇÃO!! Antes de instalar, leia este manual. VDS isenta de qualquer responsabilidade pelo não
cumprimento com os regulamentos.
Page 2
I
Istruzioni d’Uso
( EURO380 M1 )
ACCESSORISICUREZZA
OPZIONI
TESSERA RADIO
WIRELESSBAND
RILEVATORE BANDA MAGNETICA
SELEZIONI OPZIONI
OPZIONE 1 - Ciusura automatica
OPZIONE 2 - Inibizione blocco all'apertura
OPZIONE 3 - Radio aprire/Alternativo
OPZIONE 4 - Presenza Uomo
OPZIONE 5 - Tempi Doppi
OPZIONE 6 - Luce Garage
OPZIONE 7 - Contatto Sicurezza fotocellula
OPZIONE 8 - Pre-lampeggio
ONLa porta chiude automaticamente dopo il tempo a.c.
OFFNon c'è chiusura automatica
ONIl pulsante alternativo non funzione durante l'apertura.
OFFIl pulsante alternativo blocca la manovra.
ON
OFFLa tessera radio funziona come apriporta.
ON
OFFChiude per impulso del pulsante alternativo.
ONTempo di funzionamento da 1m10sec. a 2m10sec.
OFFTempo di funzionamento da 6-8sec a 1m25sec.
ONLuce del garage si accende all'apertura della porta.
OFFImpulso 2 sec.
ONLa porta inverte durante 1 sec. Durante apertura e chiusura.
OFFDurante l'apertura, la sicurezza di apertura è attiva.
ONLampeggio PERMESSO prima di cominciare l'apertura e la
OFF
La tessera radio funziona come un pulsante alternativo.
Chiude con pulsante alternativo attivato permanentemente.
chiusura.
Lampeggio NON PERMESSO prima di cominciare l'apertura e la
chiusura.
SERRATURA ELETTRICA
LUCE GARAGE
INIBITORE FOTOCELLULA
PRE LAMPEGGIO
BLOCCO EMERGENZA
SEMAFORO
INTERRUTTORE TRIFASICO
FUSIBILI
VARISTOR
DIODI ZENER
PRESENZA UOMO
TEST FOTOCELLULA
TEST CONTATTO SICUREZZA
FINE CORSA APERTURE / CHIUSURA
TASTO ALTERNATIVO
INTERRUTTORE PRESOSTATO
TEMPO APERTURA (TEMPORIZZATORE)
TEMPO CHIUSURA (TEMPORIZZATORE)
REGOLATORE DI POTENZA (TEMPORIZZATORE)
SFASATURA (REGOLATORE 1 E 2 (TEMPORIZZATORE)
INTERRUTTORE CHIUDERE
INTERRUTTORE APRIRE
AMMORTIZZAZIONE CHIUSURA
CHIUSURA AUTOMATICA
INIBITORE BLOCCO IN APERTURA
TEMPI DOPPI
USCITA BANDA SICUREZZA
USCITA FOTOCELLULA
TEMPO CHIUSURA AUTOMATICA (TEMPORIZZATORE)
TASTO BLOCCO
CHIUSURA PER CONTATTO DI SICUREZZA
REGISTRAZIONE TEMPO DIGITALE
CHIUSURA AUTOMATICA PER FINE CORSA
IMPULSO OGNI ORA
CAMBIO TEMPO PARZIALE/TOTALE
•
USCITA LIBERA DA TENSIONE
ALIMENTAZIONE PER ACCESSORI
CONTATTO 0V
PONTE SELETTORE PER PROGRAMMAZIONE VIA RADIO
SELETORE DI CANALE DI FREQUENZA
230V
380v
433MHz
868MHz
1 MOTORE
2 MOTORI
AGILITA' FREQUENZA AUTOMATICA (BRIDGE S.)
•
•••••
RICEVENTE WIRELESSBAND
OPZIONI
•
NON DISPONIBILE
STANDARD
FUNZIONAMENTO
Il pannello di controllo può attivarsi mediante il TEST placchetta CI, o pulsante P.ALT. bornes, o mediante la Tessera Radio.
La manovra termina con l'attivazione del FC corrispondente o la fine del tempo d funzionamento.
Se durante la manovra di apertura si dà un ordine, la manovra termina e non si effettua la chiusura automatica.
Premendo STOP, la porta si ferma. E' necessario premere i pulsanti APRIRE o CHIUDERE per riattivare l'operazione.
Se durante la manovra di chiusura si dà un oridine si provoca l'inversione della stessa, passando a manovra di apertura.
Il Contatto Luce di Garage si attiva iniziando la manovra di apertura e si disattiva 2 sec. dopo aver iniziato.
Se I4 è ON e I3 ON, il pannello di controllo dà l'ordine per l'aperture e chiusura automatica dell'interruttore Uomo Presente.
Se I4 è ON e I3 ON, il pannello di controllo dà l'ordine per l'apertura e chiusura dell'interruttore di Uomo Presente.
ATTENZIONE!!
PER APPARATI CONNESSI PERMANENTEMENTE, SI DOVRA' INCORPORARE AL CABLAGGIO UN
DISPOSITIVO DI CONNESSIONE FACILMENTE ACCESSIBILE.
PRIMA DI COMINCIARE L'INSTALLAZIONE, ASSICURARSI DELLA DISCONNSSIONE DELLA RETE ELETTRICA.
Page 3
I
CONTACT OUVERTURE
CONTACT FERMETURE
FREIN
LUMIÈRE
ÉTINCELLEMENT
CARTE RADIO
SAFETY EDGE
BRIDGE SELECTOR
SÉLECTEUR OPTION
RELÉ OUVRIR
RELÉ FERMER
RELÉ LUMIÈRE ÉTINCELLEMENT
RELÉ LUMIÈRE GARAGE
SÉCURITÉ
LUMIÈRE
GARAGE
INTERRUPTEUR LIMITE
Istruzioni d’Uso
( EURO380 M1 )
PANNELLO DI CONTROLLO
1 2 3 4
MOTORE
TRIFASICO
CON
RILEVATORE
BANDA
MAGNETICA
1 2 3 4
LOOP DETECTOR
ALIMENTAZIONE
N R S
TRIFASICO 380V
PONTE SELETTORE
T
TEMPS
FERMETURE AUTOMATIQUE
POWER SUPLY ON
TEMPS TRAVAIL
BRIDGE SELECTOR
BANDA SICUREZZA
NHIBITEUR
PHOTOCELLULE
CARTE
CARD
LOOP DETECTOR
CONTATTO - Normalmente chiuso (fotocellula e.g.)
il led corrispondente si accende
RESISTIVO - Contatto normalmente chiuso. Banda
sicurezza 8K2.
RILEVATORE BANDA MAGNETICA
SENZA
RILEVATORE
BANDA
MAGNETICA
OUVERTURE
FERMETURE
TEST
PHOTOCELL.
OUVRIR
FERMER
SÉCURITÉ
SÉCURITÉ
STOP
FERMER
OUVRIR
ALIMENTAZIONE
1 2 3 4
1 2 3 4
8 9 10
M
MOTORE
TRIFASICO
REGOLATORE
8 9 10
TASTO
TERMINALE
TEMPORIZZATORI
TEMPO CHIUSURA AUTOMATICA
-
+
TEMPO DI LAVORO
-
+
8 9 10
26 27
24 25
BLOCCO CHIUDERE APRIRE
Regola il tempo di chiusura e di apertura.
Ruotare a SINISTRA per diminuire e a
DESTRA per aumentare.
Minimo - 6 a 8 sec. (1m con DIP5 on)
Massimo - 110 sec.
Regola il tempo di chisura e di apertura
SINISTRA
Girare a per diminuire e a
DESTRA per aumentare.
Minimo - 6 a 8 sec. (1m con DIP5 on)
Massimo - 85 sec. (2m con DIP5 on)
BANDA DI SICUREZZA
20 21
20 21
Alimentazione220V AC +/- 10%
CARATTERISTICHE TECNICHE
Motore220V / 380V 3HP
Potenza Motore1.5HP / 3HP
Uscita alimentazione accessori12V DC 500mA
Contatto porta garageLibero da tensione
Uscita luce lampeggio
Tempo utilizzoDa 8 sec a 80 sec
Tempo chiusura automaticaDa 5 sec a 120 sec
Tessera RadioOpzionale
Loop Detector CardOpzionale
Tessera rilevatore fotocellulaOpzionale
Temperatura utilizzo
220V 10A
0 à 70º
N R S
TRIFASICO 380V
T
N R S
TRIFASICO 220V
ALIMENTAZIONE
ACCESSORI
28 29
12V
T
FRENO
5 6
220V
FRENO
N
F
UNICA FASE 220V
LAMPEGGIO
11 12
LAMPEGGIO
M
MOTORE
TRIFASICO
LUCE
13 14
LUCE
GARAGE
M
COMMON
REGOLATORE
SICUREZZA
20 21
SICUREZZA
APERTO
22 23
SICUREZZA
CHIUSO
8K2 Ohm
N.O
Banda Sicurezza
N.C
Banda Sicurezza
INTERRUTTORI
SICUREZZA
17 18
15 16
SICUREZZA APERTO CHIUSO
FINE CORSA
8K2 Ohm
TEST
FOTOCELLULA
19
TEST
FOTOC.
0v
Page 4
E
Instrucciones de Uso
ACCESORIOSSEGURIDAD
( EURO380 M1 )
OPCIONES
WIRELESSBAND
TARJETA RADIO
DETECTOR LAZO MAGNÉTICO
INHIBIDOR FOTOCÉLULA
SELECCIÓN
ELECTROCERRADURA
OPCIONES
OPCIÓN 1 - Cierre automático
OPCIÓN
OPCIÓN
OPCIÓN
OPCIÓN 5 - Tiempos dobles
OPCIÓN 6 - Luz garaje
OPCIÓN 7 - Contacto Seguridad fotocélula
OPCIÓN 8 - Pre-destello
ONLa puerta cierra automáticamente después del tiempo a.c.
OFFNo hay cierre automático
2 - Inhibición paro al abrir
ONEl pulsador alternativo no actúa durante la apertura.
OFFPulsador alternativo para la maniobra.
3 - Radio abrir/Alternativo
ON
OFFLa tarjeta radio trabaja como un abridor.
4 - Hombre Presente
ONCierre con pulsador alternativo activado permanentemente
OFFCierre por impulso de pulsador alternativo
ONTiempo de funcionamiento de 1m10seg a 2m10seg
OFFTiempo de funcionamiento de 6-8seg a 1m25seg
ONLuz de garaje se enciende al abrir la puerta
OFFImpulso 2 seg.
ONLa puerte invierte durante 1 sec. Durante apertura y cierre.
OFFDurante la apertura, la seguridad de apertura está activa.
ONDestello PERMITIDO antes de empezar la apertura y el cierre.
OFFDestello NO PERMITIDO antes de empezar la apertura y el
La terjeta radio trabaja como un botón alternativo.
cierre.
LUZ GARAJE
PRE DESTELLO
PARO EMERGENCIA
SEMÁFORO
INTERRUPTOR TRIFÁSICO
FUSIBLES
VARISTOR
SALIDA BANDA SEGURIDAD
HOMBRE PRESENTE
DIODOS ZENER
SALIDA FOTOCÉLULA
TEST FOTOCÉLULA
BOTÓN ALTERNATIVO
TEST CONTACTO SEGURIDAD
INTERRUPTOR PRESOSTATO
TIEMPO APERTURA (TEMPORIZADOR)
TIEMPO CIERRE (TEMPORIZADOR)
REGULADOR DE FUERZA (TEMPORIZADOR)
DESFASE( REGULADOR 1 Y 2 (TEMPORIZADOR)
INTERRUPTOR CERRAR
INTERRUPTOR ABRIR
AMORTIGUACIÓN CIERRE
CIERRE POR CONTACTO DE SEGURIDAD
CIERRE AUTOMÁTICO
INHIBICIÓN PARO AL ABRIR
TIEMPOS DOBLES
GRABACIÓN TIEMPO DIGITAL
FINAL DE CARRERA APERTURA/CIERRE
TIEMPO CIERRE AUTOMÁTICO (TEMPORIZADOR)
BOTÓN PARO
IMPULSO CADA HORA
•
AGILIDAD FRECUENCIA AUTOM. (Bridge S.)
INVERSIÓN TIEMPOS PARCIAL/TOTAL
CIERRE AUTOM. PARA FINAL DE CARRERA
ALIMENTACIÓN POR ACCE.
SALIDA LIBRE DE TENSIÓN
CONTACTO 0V
PUENTE SELECTOR PARA PROGRAMACIÓN VÍA RADIO
SELECTOR DE CANAL DE FRECUENCIA
230V
380v
433MHz
868MHz
1 MOTOR
2 MOTORES
•
•••••
OPCIONAL
•
NO DISPONIBLE
RECEPTOR WIRELESSBAND
STANDARD
FUNCIONAMIENTO
El panel de control puede activarse mediante el TEST placa CI, o pulsador P.ALT bornes, o mediante la Tarjeta de Radio).La maniobra finaliza
por la activación del FC correspondiente o la finalización del tiempo de funcionamiento.
Si durante la maniobra de apertura se da una orden, la maniobra finaliza y no se ejecuta el cierre automático.
Pulsando STOP, la puerta se para. Es necesario pulsar los botones ABRIR o CERRAR para reactivar la operación.
Si durante la maniobra de cierre se da una orden se provoca la inversión de ésta, pasándose a la maniobra de apertura.
El Contacto Luz de Garaje se activa al iniciar la maniobra de apertura y se desactiva 2 seg. después de haberse iniciado.
Si I4 es ON y I3 ON, el panel de control da la orden para la apertura y cierre automático del interruptor Hombre Presente.
i I4 es ON y I3 ON, el panel de control da la orden para la apertura y cierre del interruptor de Hombre Presente.
S
ATENCIÓN!!
PARA EQUIPOS CONECTADOS PERMANENTEMENTE, DEBERÁ INCORPORARSE AL CABLEADO UN
DISPOSITIVO DE CONEXIÓN FÁCILMENTE ACCESIBLE.
ANTES DE INICIAR LA INSTALACIÓN, ASEGÚRESE DE LA DESCONEXIÓN DE LA RED ELÉCTRICA
Page 5
E
Instrucciones de Uso
( EURO380 M1 )
ABRIR CONTACTO
CERRAR CONTACTO
BRAKE
LUZ
DESTELLO
GARAJE
LUZ
RADIO CARD
SAFETY EDGE
BRIDGE SELECTOR
OPTION SELECTOR
RELÉ APERTURA
RELÉ CIERRE
RELÉ LUS DESTELLO
RELÉ LUZ GARAJE
SEGURIDAD
LIMIT SWITCH
PANEL DE CONTROL
26 27
8 9 10
M
MOTOR
TRIFÁSICO
BOTONES
TERMINALES
TEMPORIZADORES
TIEMPO CIERRE AUTOMÁTICO
TIEMPO CIERRE
AUTOMÁTICO
POWER SUPLY ON
TIEMPO
TRABAJO
LOOP DETECTOR
BRIDGE SELECTOR
1 2 3 4
ALIMENTACIÓN
N R S
TRIFÁSICO 380V
T
PUENTES SELECTORES
BANDA SEGURIDAD
MOTOR
TRIFÁSICO
CONTACTO - Normalmente cerrado (fotocélula e.g.)
TARJETA
CARD
LOOP DETECTOR
FOTOCÉLULA INHIBIDOR
El led correspondiente se enciende.
RESISTIVO - Contacto normalmente
-
cerrado. Banda seguridad 8K2.
DETECTOR LAZO MAGNÉTICO
SIN
DETECTOR
LAZO MAGN.
SEGURIDAD
SEGURIDAD
TEST
FOTOCÉLULA
ABRIR
CERRAR
STOP
CLOSE
CERRAR
ABRIR
OPEN
ALIMENTACIÓN
1 2 3 4
1 2 3 4
CON
DETECTOR
LAZO MAGN.
8 9 10
1 2 3 4
TIEMPO TRABAJO
-
REGULADOR
8 9 10
24 25
PARO CERRAR ABRIR
Regula el tiempo de cierre.
Girar a la IZQUIERDA para disminuir y
+
a la DERECHA para augmentar.
Mínimo - 6 a 8 seg.
Máximo - 110 seg
Regula el tiempo de cierre y de apertura.
Girar a la IZQUIERDA para disminuir y
+
a la DERECHA para augmentar.
Mínimo - 6 a 8seg (1m con DIP5 on)
Máximo- 85 seg (2m con DIP5 on)
Tiempo trabajoDe 8 seg a 80 seg
Tiempo cierre automáticoDe 5 seg a 120 seg
Tarjeta RadioOpcional
Loop Detector CardOpcional
Tarjeta inhibidor fotocélulaOpcional
Temperatura trabajo
220V 10A
0 a 70º
N R S
trifásico 380V
T
N R S
ALIMENTACIÓN
ACCESORIOS
28 29
12V
trifásico 220V
T
FRENO
5 6
220V
FRENO
N
F
fase única 220V
DESTELLO
11 12
DESTELLO
M
MOTOR
trifásico
LUZ
13 14
GARAJE
M
COMMON
REGULADOR
SEGURIDAD
20 21
LUZ
SEGURIDAD
ABIERTO
22 23
SEGURIDAD
CERRADO
8K2 Ohm
N.O
Banda seg.
N.C
Banda seg.e
INTERRUTORES
SEGURIDAD
17 18
15 16
SEGURIDAD abierto cerrado
finales carrera
8K2 Ohm
TEST
FOTOCÉLULA
19
TEST
fotocel.T
0v
Page 6
GB
Instruction Manual
ACCESSORIESSAFETY
( EURO380 M1 )
SETTINGS
OPTIONS SELECTOR
OPTION 1 - Automatic closing
OPTION 2 - Disable stop on opening
OPTION 3 - Radio open/Alternative
OPTION 4 - DeadMan
OPTION 5 - Double time
OPTION 6 - Garage light
OPTION 7 - Safety edge photocell
OPTION 8 - Pre-flashing
ONDoor closes automatically after waiting the a.c.time
OFFDoor does not close automatically
ONOpening the alternative button is disabled
OFFIf alternative button is pressed door stops
ONWorking time range from 1m10sec to 2m10sec
OFFworking time range from 6-8secs to 1m25sec
ONGarage lights goes on when the door is opening
OFF2 secs impulse
ONDoor inverts during 1 sec. During opening and closing.
OFFDuring opening, safety opening activates
ONFlashing output ENABLED before starting, open and close
OFFFlashing output DISABLED before starting, open and close
Radio card works as alternative button
RADIO CARD
WIRELESSBAND
RADIO CARD
LOOP DETECTORLOOP DETECTOR
PHOTOCELL INHIBITOR
ELECTRO LOCK
GARAGE LIGHT
PRE FLASHING
EMERGENCY STOP
TRAFFIC LIGHT
THREEPHASE SWITCH
6AMP. FUSES
VARISTOR
SAFETY EDGE INPUT
DEAD MAN
PHOTOCELL TEST
SAFETY EDGE TEST
OPEN CLOSE LIMIT SWITCH
ALTERNATIVE BUTTON
PRESSURE WAVE SWITCH
AUTOMATIC DOWN TIME (TEMPORIZER)
OPENING TIME (TEMPORIZER)
CLOSING TIME (TEMPORIZER)
DRIVE POWER (TEMPORIZER)
DEPHASE( DRIVE 1 & 2 (TEMPORIZER)
CLOSE SWITCH
OPEN SWITCH
BUFFER CLOSING
CLOSE BY SAFETY CONTACT
AUTOMATIC CLOSING
INHIBITION STOP ON OPENING
DOUBLE TIME
ZENER DIODES
PHOTOCELL INPUT
STOP BUTTON
DIGITAL TIME
•
AUTOMATIC CLOSING FOR LIMIT SWITCH
HOURLY IMPULSE
AUTOMATIC FRECUENCY AGILITY (Bridge S.)
12 V OUTPUT
FREE TENSION INPUT
CONTACT 0V
RADIO PROGRAMMING BRIDGE SELECTOR
FRECUENCY CHANNEL SELECTOR
230V
380v
433MHz
868MHz
1 DRIVE
2 DRIVE
PARTIAL / TOTAL INVERSION TIMES
•
•••••
WIRELESSBAND RECEIVER
OPTIONAL
•
NOT AVAILABLE
STANDARD
OPERATING INSTRUCTIONS
The control panel can be activated by Test CI P.ALTER), via the radio card, or by the open, close and stop buttons.
Manoeuvres can be finalised via the following: limit switch activation or end of working time
If the ALT button is pushed while the door is opening it stops and does not close the door.
Pressing the STOP button stops the door. It is necessary to push OPEN or CLOSE buttons to reactivate the operation.
If the safety input is activated whilst the door is closing then the door will open.
The garage light contact is activated when the door is opening & deactivated after 2 seconds.
If I4 is ON y I3 ON the control panel gives the order for automatic opening and closing of the dead mans switch.
If I4 is ON y I3 OFF the control panel gives the order to open and close the dead mans switch.
WARNING!!
AN ACCESSIBLE SWITCH, TO TURN OFF THE EQUIPMENT,MUST BE INSTALLED FOR SYSTEMS
THAT ARE ALWAYS CONNECTED.
BEFORE INSTALLING MAKE SURE THE SUPPLY VOLTAGE IS SWITCHED OFF.
Page 7
GB
OPEN CONTACTOR
RADIO CARD
SAFETY EDGE
BRIDGE SELECTOR
OPTION SELECTOR
AUTOMATIC CLOSING
TIME
POWER SUPLY ON
WORKING TIME
TIME
LOOP DETECTOR
BRIDGE SELECTOR
Instruction Manual
( EURO380 M1 )
STANDARD CONTROL PANEL SET UP
1 2 3 4
POWER
SUPPLY
TERMINALS
N R S
THREE PHASE 380V
T
BRIDGE SELECTORS
SAFETY EDGE
THREE PHASE
DRIVE
8 9 10
M
THREE PHASE
MOTOR
26 27
24 25
PUSH
BUTTONS
TERMINALS
STOP CLOSE OPEN
TIME REGULATIONS
AUTOMATIC CLOSING TIME
OPEN RELAY
CLOSE CONTACTOR
BRAKE
FLASHING
LIGHT
GARAGE
LIGHT
CLOSE RELAY
FLASHING LIGHT RELAY
GARAGE LIGHT RELAY
SECURITY
LIMIT SWITCH
PHOTOCELL
TEST
OPEN
CLOSE
TECHNICAL SPECIFICATIONS
Power220V AC +/- 10%
Drive220V / 380V 3HP
Max Drive Power1.5HP / 3HP
Power Suply for accessories12V DC 500mA
Garage door output typePower free contact
Flashing light output
Working Time From 8 sec to 80 sec
Automatic closing timeFrom 5 sec to 120 sec
Radio CardOptional
Loop Detector CardOptional
Photocell inhibitor CardOptional
Working Temperature
220V 10A
0 to 70º
SECURITY
CARD
LOOP DETECTOR
CARD
PHOTOCELL INHIBITOR
CONTACT - Normally closed (e.g photocell).
In this case the corresponding led lights up.
RESISTIVE SAFETY EDGE - Normally closed
-
+
contact . 8K2 safety edge
LOOP DETECTOR
WORKING TIME
Regulates the waiting time before the automatic close
Turn LEFT to decrease and RIGHT to increase
Minimum - 6 to 8sec
Maximum - 110 secs
Regulates the opening and closing time
WITHOUT
LOOP
DETECTOR
WITH
LOOP
DETECTOR
-
+
Turn LEFT to decrease and RIGHT to increase
Minimum - 6 to 8sec (1m with DIP5 on)
Maximum - 85 secs (2m with DIP5 on)
SECURITY
STOP
OPEN
CLOSE
CLOSE
OPEN
POWER SUPPLY
1 2 3 4
N R S
THREE PHASE 380V
ACCESSORIES
POWER SUPPLY
T
28 29
1 2 3 4
N R S
THREE PHASE 220V
BRAKE
T
5 6
1 2 3 4
N
SINGLE PHASE 220V
F
FLASHING
11 12
DRIVE
8 9 10
M
THREE PHASE
DRIVE
LIGHT
13 14
8 9 10
M
COMMON
DRIVE
20 21
SAFETY
22 23
SAFETY EDGE
20 21
8K2 Ohm
N.O
Safety Edge
20 21
N.C
Safety Edge
SECURITY
SWITCHS
17 18
15 16
8K2 Ohm
PHOTOCELL
TEST
19
12V
220V
BRAKE
FLASHING
GARAGE
LIGHT
SAFETY
OPEN
SAFETY
CLOSE
SECURITY OPEN CLOSE
LIMIT SWITCHES
PHOTOCELL
TEST
0v
Page 8
F
ACCESSOIRESSÉCURITÉ
Mode d’Emploi
( EURO380 M1 )
OPTIONS
CARTE RADIO
WIRELESSBAND
SÉLECTION D’OPTIONS
OPTION 1 - Fermeture automatique
OPTION 2 -
OPTION 3 - Radio ouvert/Alternatif
OPTION 4 - Homme présent
OPTION 5 - Temps doubles
OPTION 6 - Lumière garage
OPTION 7 - Contact Sécurité photocellule
OPTION 8 - Pre-étincellement
ONLa porte ferme automatiquement après le temps a.c.
OFFLa porte ne ferme pas automatiquement
Inhabilitation stop à l’ouverture
ONDurant l’ouverture, le bouton alternatif est inhabilité
OFFLa porte s’arrête li le bouton alternatif est appuyé
ON
OFFLa carte radio travaille comme un ouverteur.
ON
OFFFonction Homme-mort déshabilitée.
ONTemps travail de 1m10sec à 2m10sec
OFFTemps travail de 6-8secs à 1m25sec
ONLa lumière s’allume quand la porte s’ouvre.
OFFImpulse 2 seg.
ONLa porte inverts pendant 1 sec. Pendant ouverture et fermeture.
OFFPendant l’ouverture, la sécurité d’ouverture est activée.
ONÉtincellement permis durant fonctionnement, ouverture et
OFF
La carte radio travaille comme un bouton alternatif.
Fonction Homme-mort habilitée.
fermeture.
Étincellement inhabilité durant fonctionnement, ouverture et
fermeture.
DÉTECTEUR DÉTOUR MAGNÉTIQUE
INHIBITEUR PHOTOCELLULE
ÉLECTRO-SERRURE
LUMIÈRE GARAGE
PRE-ÉTINCELLEMENT
ARRÊT D’URGENCE
FEU
INTERRUPTEUR TRIPHASÉ
6AMP. FUSIBLES
VARISTOR
ZENER DIODES
HOMME PRÉSENT
TEST PHOTOCELLULE
TEST CONTACT SÉCURITÉ
FIN DE COURSE OUVERTURE/FERMETURE
BOUTON ALTERNATIF
INTERRUPTEUR PRESSOSTAT
TEMPS OUVERTURE(TEMPORISATEUR)
TEMPS FERMETURE (TEMPORISATEUR)
RÉGULATEUR DE FORCE (TEMPORISATEUR)
DÉCALAGE( RÉGULATEUR 1 ET 2 (TEMPORISATEUR)
INTERRUPTEUR FERMETURE
INTERRUPTEUR OUVERTURE
FREIN FERMETURE
FERMETURE AUTOMATIQUE
INHIBITION ARRÊT À L’OUVERTURE
TEMPS DOUBLES
SORTIE BANDE SÉCURITÉ
SORTIE PHOTOCELLULE
TEMPS DESCENTE AUTOM. (TEMPORISATEUR)
BOUTON ARRÊT
FERMETURE PAR CONTACT DE SÉCURITÉ
TEMPS DIGITAL
FERMETURE AUTOMATIQUE POUR FIN DE COURSE
IMPULSE CHAQUE HEURE
INVERSION TEMPS PARTIEL/ TOTAL
•
SORTIE LIBRE DE TENSIÓN
AGILITÉ FRÉQUENCE AUTOM. (Bridge S.)
SORTIE 12 V
CONTACT 0V
PONT SÉLECTEUR POUR PROGRAMMATION VIA RADIO
CANAL SÉLECTEUR FRÉCUENCE
230V
380v
433MHz
868MHz
1 MOTEUR
2 MOTEURS
RÉCEPTEUR WIRELESSBAND
OPTIONNEL
•
NON DISPONIBLE
•
•••••
STANDARD
FONCTIONNEMENT
Les manoeuvres s’éxecutent grâce au bouton “P.ALT", via carte radio ou par les boutons oubrir, fermer et arrêter.
Les opérations de la porte finalisent par les conditions suivantes: Activation de l’interrupteur de limite correspondant ou fin du
temps de travail. .
Si pendant l’ouverture on donne une ordre, la porte ne fermera pas automatiquement.
Si pendant la fermeture on donne une ordre, la porte va s’arrêter.Avec une nouvelle ordre, la porte s’ouvrira.
Le led du garage s’active avec l’ouverture de la porte et se désactive après 2 secondes.
Avec l’interrupteur 4 OFF l’entrée CSEG1 fonctionnera comme pressostat (N.C.) et provoquera l’inversion quand la porte ferme.
En ce cas-là, le Cseg 1sera inhibé pendant 3 sec.
Avec l’interrupteur 4 en ON l’entrée CSEG1 fonctionne comme une bande de sécurité (8,2Kohms) et inverse la manoeuvre à
l’ouverture et à la fermeture.
ATTENTION!!
POUR LES APPAREILS CONNECTÉS DE FORME PERMANENTE, ON DEVRA INCORPORER AU CÂBLAGE
UN DISPOSITIF DE DÉCONNEXION FACILEMENT ACCESSIBLE. AVANT L’INSTALLATION, ASSUREZ-VOUS
DE LA DÉCONNEXION DE L’ALIMENTATION.
Page 9
F
CONTACT OUVERTURE
CARTE RADIO
SAFETY EDGE
BRIDGE SELECTOR
SÉLECTEUR OPTION
TEMPS
FERMETURE AUTOMATIQUE
POWER SUPLY ON
TEMPS TRAVAIL
LOOP DETECTOR
BRIDGE SELECTOR
Mode d’Emploi
( EURO380 M1 )
TABLEAU DE COMMANDES
1 2 3 4
ALIMENTATION
N R S
TRIPHASÉ 380V
T
PONTS SÉLECTEURS
BANDE SÉCURITÉ
TRIPHASÉ
MOTEUR
8 9 10
M
MOTEUR
TRIPHASÉ
26 27
24 25
FIN
BOUTONS
STOP FERMÉ OUVERT
RÉGLAGE TEMPS
TEMPS FERMETURE AUTOMATIQUE
RELÉ OUVRIR
CONTACT FERMETURE
FREIN
ÉTINCELLEMENT
LUMIÈRE
RELÉ FERMER
RELÉ LUMIÈRE ÉTINCELLEMENT
RELÉ LUMIÈRE GARAGE
SÉCURITÉ
LUMIÈRE
GARAGE
INTERRUPTEUR LIMITE
OUVRIR
FERMER
CARACTÉRISTIQUES TECHNIQUES
Alimentation220V AC +/- 10%
Puissance220V / 380V 3HP
Puissance max. trans.1.5HP / 3HP
Alimentation pour accessoires12V DC 500mA
Mode rendement porte garageForce contact libre
Led rendement
Temps travailDe 8 sec à 80 sec
Temps fermeture automatiqueDe 5 sec à 120 sec
Carte-radioOptionel
Carte detecteur courbeOptionel
Carte inhibiteur photocelluleOptionel
Température travail
220V 10A
0 à 70º
PHOTOCELL.
NHIBITEUR
PHOTOCELLULE
CARTE
CARD
LOOP DETECTOR
DETECTEUR NOEUD
CONTACT - Normalement fermé (e.g photocell).
En ce cas, le led correspondant s’allume.
BANDE SÉCURITÉ RÉSISTIVE - Contact
normalement fermé . Bande sécurité 8K2
-
+
TEMPS TRAVAIL
Il règle le temps d’attente avant la fermeture automatique
Tourner à GAUCHE pour diminuer et DROITE pour augmenter
Minimum - 6 à 8sec
Maximum - 110 secs
Il règle le temps d’ouverture et fermeture
Tourner à GAUCHE pour diminuer et DROITE pour augmenter
Minimum - 6 à 8sec (1m avec DIP5 on)
Maximum - 85 secs (2m avec DIP5 on)
BANDE SÉCURITÉ
22 23
20 21
8K2 Ohm
N.O
Bande Sécurité
INTERRUPTEURS
SÉCURITÉ
15 16
20 21
N.C
BANDE SÉCURITÉ
17 18
8K2 Ohm
TEST
PHOTOCELLULE
19
T
FREIN
AVEC
DETECTEUR
NOEUD
1 2 3 4
N
F
FASE UNIQUE 220V
ÉTINCELLEMENT
-
RÉGULATEUR
8 9 10
M
MOTEUR
TRIPHASÉ
LUMIÈRE
8 9 10
COMMON
RÉGULATEUR
+
M
SÉCURITÉ
SANS
DETECTEUR
NOEUD
OUVERTURE
FERMETURE
TEST
SÉCURITÉ
SÉCURITÉ
STOP
FERMER
OUVRIR
ALIMENTATION
1 2 3 4
N R S
TRIPHASÉ 380V
T
1 2 3 4
N R S
TRIPHASÉ 220V
ACCESSOIRES
ALIMENTATION
28 29
5 6
11 12
13 14
20 21
12V
220V
FREIN
ÉTINCELL.
LUMIÈRE
GARAGE
SÉCURITÉ
OUVERTURE
SÉCURITÉ
FERMETURE
sécurité ouvert fermé
fin de course
TEST
PHOTOC.
0v
Page 10
P
SELECÇÃO
OPÇÕES
ACESSÓRIOSSEGURANÇA
CARTÃO RÁDIO
WIRELESSBAND
DETECTOR LAÇO MAGNÉTICO
INIBIDOR CÉLULA FOTOELÉCTRICA
ELECTRO-FECHADURA
LUZ GARAGEM
PrÉ ILUMINAÇÃO
PARAGEM DE EMERGÊNCIA
SEMÁFORO
INTERRUPTOR TRIFÁSICO
FUSÍVEIS
VARISTOR
DÍODO ZENER
SAÍDA CÉLULA FOTOELÉCTRICA
Instruções de Uso
( EURO380 M1 )
SAÍDA BANDA DE SEGURAÇA
HOMEM PRESENTE
TESTE CÉLULA FOTOELÉCTRICA
TESTE CONTACTO SEGURANÇA
FINAL DE PERCURSO ABERTURA / FECHAMENTO
BOTÃO ALTERNATIVO
INTERRUPTOR REGULADOR DE PRESSÃO
TEMPO ABERTURA (TEMPORIZADOR)
TEMPO FECHAMENTO (TEMPORIZADOR)
REGULADOR DE FORÇA(TEMPORIZADOR)
DESFASE (REGULADOR 1 & 2 (TEMPORIZADOR)
INTERRUPTOR FECHAR
INTERRUPTOR ABRIR
AMORTECIMENTO FECHAMENTO
FECHAMENTO POR CONTACTO DE SEGURANÇA
TEMPO FECHAMENTO AUTOMÁTICO (TEMPORIZADOR)
BOTÃO PARAGEM
•
OPÇÕES
OPCIONAL
FECHAMENTO AUTOMÁTICO
INIBIÇÃO PARAGEM AO ABRIR
TEMPOS DUPLOS
TEMPO DIGITAL
FECHAMENTO AUTOMÁTICO PARA FINAL DE PERCURSO
IMPULSO CADA HORA
INVERSÃO TEMPOS PARCIAL/TOTAL
ALIMENTAÇÃO PARA ACESSÓRIOS
SAÍDA LIVRE DE TENSÃO
CONTACTO 0V
PONTE SELECTOR PARA PROGRAMAÇÃO ATRAVÉS DE RÁDIO
SELECTOR DE CANAL DE FREQUÊNCIA
230V
380v
433MHz
868MHz
AGILIDADE FREQUÊNCIA AUTOMÁTICA (Bridge S.)
•
1 MOTOR
•••••
•
2 MOTORES
RECEPTOR WIRELESSBAND
NÃO DISPONÍVEL
STANDARD
OPÇÃO 1 - Fecho automático
OPÇÃO
OPÇÃO
OPÇÃO
OPÇÃO 5 - Tempos duplos
OPÇÃO 6 - Luz garagem
OPÇÃO 7 - Contacto Segurança célula fot.
OPÇÃO 8 - – Pré ilum.
ONA porta fecha automaticamente, depois do tempo a.c.
OFFNão há fecho automático
2 - Inibição paragem ao abrir
ONO botão alternativo não funciona durante a abertura.
OFFBotão alternativo para a manobra.
3 - Rádio abrir/Alternativo
ON
OFFO cartão rádio funciona para abrir.
4 - Homem Presente
ONFecho com botão alternativo activado permanentemente
OFFFecho por impulso do botão alternativo
ONTempo de funcionamento de 1m10seg a 2m10seg
OFFTempo de funcionamento de 6-8seg a 1m25seg
ONLuz de garagem acende ao abrir a porta.
OFFImpulso 2 seg.
ONA porta inverte durante 1 seg. Durante abertura e fecho.
OFFDurante a abertura, a segurança de abertura está activa.
ONIluminação PERMITIDA antes de iniciar a abertura e o fecho.
OFFIluminação NÃO PERMITIDA antes de iniciar a abertura e o
O cartão rádio funciona como um botão alternativo.
fecho.
FUNCIONAMENTO
O painel de controlo pode ser activado através do TESTE placa CI, ou botão P.ALT bornes, ou do Cartão de Rádio. A manobra finaliza com a
activação do FC correspondente ou finalização do tempo de funcionamento.
Quando dada uma ordem durante a manobra de abertura, a manobra finaliza e não é executado o fecho automático. Ao carregar no botão
STOP, é interrompido o movimento da porta. É necessário carregar nos botões ABRIR ou FECHAR para activar novamente a operação.
Quando dada uma ordem durante a manobra de fecho é provocada a inversão da manobra e passa-se à manobra de abertura.
O Contacto Luz de Garagem é activado ao iniciar a manobra de abertura e desactivado 2 seg. depois de ter iniciado.
Se I4 está em ON e I3 ON, o painel de controlo emite a ordem para a abertura e fecho automático do interruptor Homem Presente.
Se I4 está em ON e I3 ON, o painel de controlo emite a ordem para a abertura e fecho do interruptor de Homem Presente.
ATENÇÃO!
PARA EQUIPAMENTOS LIGADOS PERMANENTEMENTE, INCORPORAR UM DISPOSITIVO LIGAÇÃO
DE FACIL ACCESSO NOS FIOS.
ANTES DE INICIAR A INSTALAÇÃO, DESLIGAR A REDE ELÉCTRICA.
Page 11
P
Instruções de Uso
( EURO380 M1 )
ABRIR CONTACTO
CERRAR CONTACTO
BRAKE
LUZ
DESTELLO
GARAJE
LUZ
RADIO CARD
SAFETY EDGE
BRIDGE SELECTOR
OPTION SELECTOR
RELÉ APERTURA
RELÉ CIERRE
RELÉ LUS DESTELLO
RELÉ LUZ GARAJE
SEGURIDAD
LIMIT SWITCH
PANEL DE CONTROL
26 27
8 9 10
M
MOTOR
TRIFÁSICO
BOTÕES
TERMINAIS
TEMPORIZADORES
TEMPO FECHO AUTOMÁTICO
TIEMPO CIERRE
AUTOMÁTICO
POWER SUPLY ON
TIEMPO
TRABAJO
LOOP DETECTOR
BRIDGE SELECTOR
1 2 3 4
ALIMENTAÇÃO
N R S
TRIFÁSICO 380V
T
PONTES SELECTORES
BANDA SEGURANÇA
MOTOR
TRIFÁSICO
CONTACTO - Normalmente fechado (célula fot.,
TARJETA
CARD
LOOP DETECTOR
FOTOCÉLULA INHIBIDOR
por exemplo) O led correspondente acende.
RESISTIVO - Contacto normalmente fechado.
-
Banda segurança 8K2.
DETECTOR LAÇO MAGNÉTICO
SEM
DETECTOR
LAÇO MAGN.
SEGURIDAD
SEGURIDAD
TEST
FOTOCÉLULA
ABRIR
CERRAR
STOP
CLOSE
CERRAR
ABRIR
OPEN
ALIMENTAÇÃO
1 2 3 4
1 2 3 4
COM
DETECTOR
LAÇO MAGN.
8 9 10
1 2 3 4
TEMPO FUNCIONAMENTO
-
REGULADOR
8 9 10
24 25
PARO FECHAR ABRIR
Regula o tempo de fecho.
À DIREITA para diminuir
+
à ESQUERDA para aumentar.
Mínimo - 6 a 8 seg.
Máximo - 110 seg
Regula o tempo de fecho e de abertura.
À DIREITA para diminuir e à ESQUERDA para aumentar.
+
Mínimo - 6 a 8 seg (1m com DIP5 on)
Máximo - 85 seg (2m com DIP5 on)
BANDA SEGURANÇA
20 21
20 21
Alimentação220V AC +/- 10%
CARACTERÍSTICAS TÉCNICAS
Motor220V / 380V 3HP
Potência motor1.5HP / 3HP
Saída alimentação acessórios12V DC 500mA
Contacto porta garagemLivre de tenão
Saída luz
Tempo funcionamentoDe 8 seg a 80 seg
Tempo fecho automáticoDe 5 seg a 120 seg
Cartão Rádio Opcional
Loop Detector CardOpcional
Cartão inhibidor célula fot.Opcional
Temperatura func.
220V 10A
0 a 70º
N R S
trifásico 380V
T
N R S
ALIMENTAÇÃO
ACCESÓRIOS
28 29
12V
trifásico 220V
TRAVÃO
T
5 6
220V
FRENO
N
F
fase única 220V
ILUM.
11 12
ILUM.
M
MOTOR
trifásico
LUZ
13 14
GARAGEM
M
COMMON
REGULADOR
SEGURANÇA
20 21
LUZ
SEGURANÇA
ABIERTO
22 23
SEGURANÇA
FECHADO
8K2 Ohm
N.O
Banda seg.
N.C
Banda seg.e
INTERRUTORES
SEGURANÇA
17 18
15 16
SEGURANÇA abierto fechado
finales percurso
8K2 Ohm
TESTE
CÉLULA FOT.
19
TESTE
fotocel.T
0v
Page 12
I nostri prodotti se installati da personale specializzato idoneo alla valutazione
dei rischi, rispondono alle normative UNI EN 12453-EN 12445
Nuestros productos tienen que ser instalados por personal cualificado capaz de evaluar los possible riesgos,
cumplendo con la norma UNI EN 12453, EN 12445
UNI
EN
I dati e le immagini sono puramente indicativi
VDS si riserva il diritto di modificare in qualsiasi momento le caratteristiche dei prodotti descritti a suo insindacabile
giudizio, senza alcun preavviso.
Los datos y las imágenes son orientativos
VDS se reserva el derecho de modificar en cualquier momento las características de los productos descritos en su única discreción,
sin previo aviso.
The data and images are for guidance only
VDS reserves the right to change at any time characteristics of the products described in its sole discretion, without notice.
Les données et les images sont à titre indicatif seulement
VDS réserve le droit de modifier à tout moment les caractéristiques des produits décrits à sa seule discrétion, sans préavis.
Os dados e as imagens são apenas para orientação
VDS reservas o direito de alterar, a qualquer tempo as características dos produtos descritos em seu exclusivo critério, sem aviso
prévio.
Our products if installed by qualified personnel capable to evaluate risks,
complies with UNI EN 12453, EN 12445 normative
Nos produits si installés par personnel qualifié capable d'évaluer les risques,
sont conformer à la norme UNI EN 12453, EN 12445
Nossos produtos se instalado por pessoal qualificado, capaz de avaliarrisco,
cumprir UNI EN 12453, EN 12445
Il marchio CE è conforme alla direttiva europea CEE 89/336 + 93/68 D.L.04/12/1992 n.476
El marcaje CE indica que cumple con la directiva europea CEE 89/336 + 93/68 D.L.04/12/1992 n.476
The CE mark indicated that complies with EEC European directiva 89/336 + 93/68 D.L.04/12/1992 n.476
Le marque CE est conforme avec la CEE directiva europèenne 89/336 + 93/68 D.L.04/12/1992 n.476
A marca CE em conformidade com a Directiva Europeia CEE 89/336 + 93/68 D.L.04/12/1992 n.476
V
AUTOMAZIONE ACCESSI
MADE IN ITALY
D
S
Via Circolare p.i.p. sn
65010 Santa Teresa di Spoltore (PE) - Italy
Tel. 085-4971946 - Fax 085-4973849
www.vdsproduction.it - vds@vdsproduction.it
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.