The use and installation of this product must conform to local codes. In absence of local codes,
use the latest edition of the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or International
Fuel Gas Code. This appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the National Electrical Code, ANSI/NFPA
70, if applicable.
For installation in Canada - these instructions, while generally acceptable do not necessarily
comply with the Canadian installation codes, particularly with piping above and below ground.
In Canada the installation of this appliance must comply with local codes and/or standard CAN/
CGA B149.1 (installation code for propane burning appliances and equipment).
California Proposition 65: Chemicals known to the State of California to cause cancer, birth
defects, or other reproductive harm are created by the combustion of propane.
DANGER
Never operate this appliance unattended.
Manufactured in China for: Blue Rhino Global Sourcing, Inc
Winston-Salem, NC 27105 USA • 1.800.762.1142, www.bluerhino.com
is a Registered Trademark of Blue Rhino Global Sourcing, Inc. All Rights Reserved GAD920SP-OM-104 E
LP Gas Outdoor Fireplace Model No. GAD920SP
DANGERS and WARNINGS: FOR YOUR SAFETY
DANGER: Failure to follow the dangers, warning and cautions in this manual may result in serious bodily injury or death, or in a fire or an explosion
causing damage to property.
WARNING:
This appliance is for outdoor use only, and shall NOT be used in a
building, garage or any other enclosed area.
Do NOT operate, light or use this appliance within ten (10) feet (3.05 m)
of walls, structures or buildings.
For residential use only. This outdoor fireplace is NOT for commercial use.
This outdoor fireplace is safety certified for use in the United States and/
or Canada only. Do not modify for use in any other location. Modification
will result in a safety hazard.
Do NOT use this outdoor fireplace for indoor heating. TOXIC carbon
monoxide fumes can accumulate and cause asphyxiation.
Apartment Dwellers: Check with management to learn the requirements
and fire codes for using an LP gas outdoor fireplace in your apartment
complex. If allowed, use outside on the ground floor with a ten (10) foot
(3.05 m) clearance from any structure. Do not use on or under balconies.
This outdoor fireplace is for use with liquid propane (LP) gas only. The
conversion to or attempted use of natural gas in this outdoor fireplace is
dangerous and will void your warranty.
LP gas is flammable and hazardous if handled improperly. Become
aware of the characteristics before using any LP gas product.
a. LP gas is explosive under pressure, heavier than air, and settles and
pools in low areas.
b. LP gas in its natural state has no odor. For your safety, an odorant is
added that smells like rotten cabbage.
c. Contact with LP gas can cause freeze burns to skin.
LP gas tank needed to operate. Only tanks marked “propane” may be
used.
a. The LP gas supply tank must be constructed and marked in
accordance with the Specifications for LP gas LP gas tanks of the
U.S. Department of Transportation (DOT) or the National Standard
of Canada, CAN/CSA-B339, LP gas tanks, Spheres and Tubes for the
Transportation of Dangerous Goods; and Commission.
b. LP gas tank must be arranged for vapor withdrawal.
c. The LP gas tank must have a listed overfilling prevention device (OPD)
and a QCCI or Type I (CGA810) LP gas tank connection.
d. The LP gas tank must have a tank collar to protect the tank valve.
e. Never use an LP gas tank with a damaged body, valve, collar or footing.
f. Dented or rusted LP gas tanks may be hazardous and should be
checked by your LP gas supplier prior to use.
g. The LP gas tank should not be dropped or handled roughly.
You must follow all leak-checking procedures before operating. To
prevent fire or explosion hazard when testing for a leak:
a. Always perform leak test before lighting the outdoor fireplace and
each time the tank is connected for use.
b. No smoking. Do not use or permit sources of ignition in the area while
conducting a leak test.
c. Conduct the leak test outdoors in a well-ventilated area.
d. Do not use matches, lighters or a flame to check for leaks.
e. Do not use outdoor fireplace until any and all leaks are corrected.
If you are unable to stop a leak, disconnect the LP gas supply. Call a
gas appliance serviceman or your local LP gas supplier.
Do not store or use gasoline or other flammable liquids or vapors within
25 feet (7.62 m) of this appliance.
Do not use in an explosive atmosphere. Keep outdoor fireplace area
clear and free from combustible materials, gasoline and other flammable
vapors and liquids.
This outdoor fireplace is NOT to be operated by children.
This outdoor fireplace is NOT to be used in or on boats or recreational
vehicles.
Do NOT connect to a remote gas supply.
Never attempt to attach this outdoor fireplace to the self-contained LP
gas system of a camper trailer, motor home or house.
Always use in accordance with all applicable local, state and national
codes. Contact your local fire department for details on outdoor burning.
When using this outdoor fireplace, exercise the same precautions you
would with any open fire.
The use of alcohol, prescription or non-prescription drugs may impair
the consumer’s ability to properly assemble or safely operate this
outdoor fireplace.
Do NOT use this outdoor fireplace without reading the entire “Owner’s
Manual”.
Do NOT burn solid fuels such as: wood, charcoal briquets, lump charcoal,
manufactured logs, driftwood, trash, leaves, paper, cardboard, plywood,
painted or stained or pressure treated wood in this outdoor fireplace.
It is essential to keep the outdoor fireplace’s valve compartment,
burners, and circulating air passages clean. Inspect outdoor fireplace
before each use.
Do NOT use this outdoor fireplace until it is COMPLETELY assembled and
all parts are securely fastened and tightened.
h. Tanks must be stored outdoors, out of the reach of children and must
not be stored in a building, garage or any other enclosed area. Your
LP gas tank must never be stored where temperatures can reach over
125°F.
i. Do not insert any tool or foreign object into the valve outlet or safety
relief valve. You may damage the valve and cause a leak. Leaking
propane may result in explosion, fire, severe personal injury or death.
j. Never keep a filled LP gas tank in a hot car or car trunk. Heat will cause
the gas pressure to increase, which may open the relief valve and allow
gas to escape.
k. Place dust cap on valve outlet whenever the LP gas tank is not in use.
Only install the type of dust cap on the LP gas tank valve outlet that is
provided with the LP gas tank valve. Other types of caps or plugs may
result in leakage of propane.
l. Do not store a spare LP gas tank under or near this appliance.
m. Never fill the tank beyond 80 percent full.
Your outdoor fireplace has been checked at all factory connections
for leaks. Recheck all connections as described in the “Operating
Instructions” section of this manual, as movement in shipping can loosen
connections.
Do NOT use this outdoor fireplace near automobiles, trucks, vans or
recreational vehicles.
Do NOT use this outdoor fireplace under any overhead or near any
unprotected combustible constructions. Avoid using near or under
overhanging trees and shrubs.
Always use this outdoor fireplace on a hard, level, non-combustible
surface such a concrete, rock or stone. An asphalt or blacktop surface
may not be acceptable for this purpose.
Do NOT use this outdoor fireplace for cooking.
Do NOT use this outdoor fireplace if any part has been under water.
Immediately call a qualified service technician to inspect the appliance
and to replace any part or control system and any gas control which has
been under water.
Do NOT wear flammable or loose clothing when operating this outdoor
fireplace.
Do NOT use in windy conditions.
Never lean over this outdoor fireplace when lighting or when in use.
Do NOT use this outdoor fireplace unless burner is securely in place.
Keep all electrical cords away from outdoor fireplace during use.
Check for leaks even if your unit was assembled for you by someone
else.
Do not operate if gas leak is present. Gas leaks may cause a fire or
explosion.
Certain areas of this outdoor fireplace when in use will become too
hot to touch. To avoid burns, do not touch hot surfaces until the unit
has cooled (about 45 minutes) unless you are wearing protective gear
(insulated pot holder or heat resistant gloves or mittens).
Contact 1.800.762.1142 for assistance. Do not return to place of purchase.
page no.
3
Do NOT leave a lit outdoor fireplace unattended, especially around
children and pets.
Children and adults should be alerted to the hazards of high surface
temperatures and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the area
of the appliance.
Clothing or other flammable materials should not be hung from the
appliance or placed on or near the appliance.
Any guard or other protective device removed for servicing the appliance
must be replaced prior to operating the appliance.
Cover must be removed when burner is in operation.
Do not attempt to move outdoor fireplace when in use. Allow the
outdoor fireplace to cool before moving or storing.
This outdoor fireplace should be thoroughly cleaned and inspected
on a regular basis. Clean and inspect the hose before each use of the
appliance. If there is evidence of abrasion, wear, cuts, or leaks, the hose
must be replaced prior to the appliance being put into operation.
This outdoor fireplace should be inspected at least annually bu a
qualified service person. Depending on amount of use, more frequent
cleaning may be required. Do not operate until all parts have been
repaired or replaced.
Use only the regulator and hose assembly provided. The replacement
regulator and hose assembly shall be that specified by the manufacturer.
Use only Blue Rhino Global Sourcing, Inc factory authorized parts. The
use of any part that is NOT factory authorized can be dangerous and will
void your warranty.
Storage of this outdoor fireplace indoors is permissible only if the tank
is disconnected, removed from the outdoor fireplace and properly stored
outdoors.
Do not attempt to disconnect the gas regulator from the tank or any gas
fitting while the outdoor fireplace is in use.
If the outdoor fireplace is not in use, the gas must be turned off at the
supply tank.
The pressure regulator is set for 10.5 inches of water column (pressure).
The maximum inlet gas pressure for this outdoor fireplace is 11 inches
of water column pressure.
Turn LP gas tank valve closed, disconnect gas regulator prior and during
pressure testing of the gas supply piping system at test pressures equal
to or less than 1/2 psi (3.5 kPa).
Do NOT sit on the mantle.
Do not throw anything onto the fire when the unit is in operation.
Fire logs and lava rock are very hot, keep the children or pets away at a
safe distance.
The opening of the tank collar should face toward the door side for easy
access.
Do NOT store any combustible materials in the base enclosure.
Use protective gloves when assembling this product.
Do not force parts together as this can result in personal injury or
damage to the product.
Deaths, serious injury or damage to property may occur if the above is
not followed exactly.
LP Gas Outdoor Fireplace Model No. GAD920SP
Parts List
Cement Log (4)
1
Lava Rock
2
Lava Rock Grid
3
Side Panel (6)
4
Bowl Assembly*
5
Burner*
6
Igniter*
7
Control Knob*
8
Regulator/Hose Assembly*
9
Hearth
10
Back Leg (2)
11
Middle Support Leg (3)
12
Tank Guard
13
55-05-432
55-05-433
55-05-434
55-05-435
55-05-443
55-05-444
58-10-000
55-05-430
55-05-431
55-05-441
55-05-436
55-05-452
58-10-001
58-10-002
58-10-003
55-05-458
Exploded View
4
1
2
3
4
5
6
7
10
9
25
8
4
4
LP Gas Tank Retaining
14
Chain
LP Gas Tank Tray Peg
15
Base Support Bar
16
Left Front Leg
17
Left Door
18
Door Support Leg
19
Right Door
20
Right Front Leg
21
Door Knob (2)*
22
Base*
23
LP Gas Tank Tray*
24
LP Gas Tank Shield
25
Cover (not shown)
26
55-05-447
55-05-449
58-10-004
58-10-005
58-10-006
58-10-007
58-10-008
58-10-009
58-10-010
58-10-011
55-05-448
55-05-458
55-05-693
11
11
13
12
16
4
12
14
12
4
15
21
19
20
1718
23
24
22
* Pre-assembled
Hardware
A
B
C
Screw
Screw
Screw
M5x10 Black Nickel Plated Hex
M5x10 Black Nickel Plated Truss Head
ø4x16 Black Nickel Plated Truss Head
9 pcs
68 pcs
2 pcs
Tools Required for Assembly (Included)
M5 Allen Wrench
D
E
Wing Nut
AA Battery
ø5 Black Nickel Plated
1.5 V AA Battery
3 pcs
1 pc
Tools Required for Assembly (Not Included)
#2 Phillips Head Screwdriver
Contact 1.800.762.1142 for assistance. Do not return to place of purchase.
Assembly Instructions
page no.
5
1
DO NOT RETURN PRODUCT TO STORE.
For assistance call 1.800.762.1142 toll free. Please have
your owner’s manual and model number available for
reference.
For Easiest Assembly:
• To avoid losing any small components or hardware, assemble
your product on a hard level surface that does not have cracks
or openings.
• Clear an area large enough to layout all components and
hardware.
• When applicable, tighten all hardware connections by hand
first. Once the step is completed go back and fully tighten all
hardware.
• Follow all steps in order to properly assemble your product.
To complete assembly you will need:
• (1) Leak Detection Solution (Instructions on how to make
solution are included in the “Operating Instructions” section of
this manual)
• (1) Precision Filled LP Gas Grill Tank with Acme Type 1 external
threaded valve connection (4-5 gallon size)
Attach Bowl Assembly
Note: The control panel must line up with the two holes on the mantel frame.
2
3
Typical assembly: approximately 1 (one) hour.
Attach LP Gas Tank Shield
4
B
Attach Side Panels, Back Legs and Middle Support Leg
x 4
B
x 4
A
x 3
B
x 12
Assembly Instructions (continued)
LP Gas Outdoor Fireplace Model No. GAD920SP
5
Attach Side Panels, Left Front Leg and Middle
Support Leg
Attach Side Panels, Right Front Leg and Middle
Support Leg
6
7
A
Attach Base
x 2
B
x 12
A
Attach Door Support Leg
x 2
B
x 12
8
B
x 18
A
x 2
B
x 4
Contact 1.800.762.1142 for assistance. Do not return to place of purchase.
page no.
7
9
Attach Tank Guard
Attach Base Support Bar
10
D
Attach Doors
11
x 3
12
B
Place Wood Grid and Lava Rocks
Do NOT dump lava rocks out of package. Carefully place lava rocks by hand so
dust does not clog burner.
x 2
C
Place Cement Logs
x 2
LP Gas Outdoor Fireplace Model No. GAD920SP
Assembly Instructions (continued)
Insert Battery
Note: Remove plastic wrapper before installing battery.
13
Installing LP Gas Tank
To operate you will need (1) precision-filled standard grill LP gas
tank (20#) with external valve threads.
Note: An empty standard grill LP gas tank weighs approximately
18 lbs. A precision-filled standard grill LP gas tank should weigh
no more than 38 lbs.
Caution: LP gas tank must be properly
disconnected and removed prior to moving this
grill.
Need a tank of gas? Try tank exchange service. It’s easy, fast, safe, and
available at tens of thousands of conveniently located retail outlets nationwide. You can purchase a new full tank or exchange your empty for a
precision filled one.
Insert LP Gas Tank
WARNING: Make sure LP gas tank valve is closed. Close by turning
valve clockwise.
Place precision filled LP gas tank upright into hole in the base of the outdoor fireplace so it is
arranged for vapor withdrawal.
20 lb
9 Kg
12.2 in. / 31 cm
17.9 in. / 45.5 cm
E
x 1
Secure LP Gas Tank
Secure tank by sliding tank retainer chain around the LP gas tank and insert peg into LP gas
tank tray.
Note: Peg must be inserted into LP gas tank when tank is in LP gas tank tray.
Connect LP Gas Tank
Before connecting, be sure that there is no debris caught in the
head of the LP gas tank, head of the regulator valve or in the
head of the burner and burner ports.
Connect regulator/hose assembly to tank by turning knob
clockwise until it stops.
Disconnect LP Gas Tank
Before disconnecting make sure the LP gas tank valve is
“CLOSED”.
Disconnect regulator/hose assembly from LP gas tank by
turning knob counterclockwise until it is loose.
Caution: LP gas tank must be properly
disconnected and removed prior to moving
this grill.
Contact 1.800.762.1142 for assistance. Do not return to place of purchase.
X
X
X
X
X
Operating Instructions
page no.
9
Checking for Leaks
WARNING: Before using this outdoor
fireplace, make sure you have read,
understand and are following all
information provided in the Dangers
and Warnings presented on page 2.
Failure to follow those instructions
can cause death, serious injury or
property damage.
Burner Connections
1. Make sure the regulator valve and hose
connections are securely fastened to the burner
and the tank.
If your unit was assembled for you, visually check
the connection between the burner venturi pipe
and orifice. Make sure the burner venturi pipe fits
over the orifice.
WARNING: Failure to inspect
this connection or follow these
instructions could cause a fire or an
explosion which can cause death,
serious bodily injury, or damage to
property.
2. Please refer to diagram for proper installation.
(Figures 1 and 2)
3. If the burner pipe does not rest flush to the orifice,
please contact 1.800.762.1142 for assistance.
Tank/Gas Line Connection
1. Make 2-3 oz. of leak solution by mixing one part
liquid dishwashing soap with three parts water.
2. Make sure control knobs are “OFF
(Figure 3)
3. Connect LP gas tank per “Installing LP Gas Tank”
section.
4. Turn LP gas tank valve to “OPEN”.
3. Spoon several drops of solution, or use squirt
bottle, at all “X” locations (Figures 1 and 2).
a. If any bubbles appear remove the LP gas tank
and reconnect, making sure the connection is
secure.
b. If you continue to see bubbles after several
attempts, remove the LP gas tank per
“Disconnect LP Gas Tank” instructions, and
contact 1.800.762.1142 for assistance.
c. If no bubbles appear after one minute, wipe
away solution and proceed.
” position.
Lighting
LP Gas Valve
with Orice
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
LP Gas
Connection
OFF
c. Turn control knob counterclockwise to (LOW).
d. Remove long match/long butane lighter once lit.
CAUTION: After Lighting - Using a shovel and heat resistant gloves,
carefully move the lava rocks back to their proper position, being
careful to avoid the flame.
9. After lighting, observe the burner flame, make sure all burner ports are lit and flame height
matches illustration. (Figure 5)
10. Adjust flame to desired height with the control knob.
Caution: If burner flame goes out during operation, immediately turn
the control knob
(OFF) and open lid to let the gas clear for 5 minutes
before re-lighting.
Turning Off
1. Turn LP gas tank valve to “CLOSED”.
2. Turn all control knobs to the “OFF
Note: A “poof” sound is normal as the last of the LP gas is burned.
3. Disconnect LP gas tank per “Disconnect LP Gas Tank” instructions.
” position.
Cleaning and Care
CAUTION:
1. All cleaning and maintenance should be done when outdoor
fireplace is cool and with the fuel supply disconnected.
2. DO NOT clean any outdoor fireplace part in a self cleaning oven. The
extreme heat will damage the finish.
3. Do not enlarge valve orifices or burner ports when cleaning the
valves or burners.
Notices
1. This outdoor fireplace should be thoroughly cleaned and inspected on a regular basis.
2. Abrasive cleaners will damage this product.
3. Never use oven cleaner to clean any part of outdoor fireplace.
Before Each Use:
1. Keep the outdoor fireplace area clean and free from any combustible materials, gasoline, and
other flammable vapors and liquids.
2. Do not obstruct the flow of the combustion of LP and the ventilation air.
3. Keep the ventilation opening(s) of the LP gas tank area free and clear from debris.
4. Visually check the burner flames to make sure your outdoor fireplace is working properly.
5. See sections below for proper cleaning instructions.
6. Check all gas connections for leaks.
7. Check components for any signs of damage or rust.
8. Check and clean the burner/venturi tubes for insects and insect nests. A clogged tube can
lead to a fire beneath the outdoor fireplace.
9. If damage to any component is detected, do NOT operate until repairs are executed.
Caution: Keep outdoor gas cooking
appliance area clear and free from
combustible materials, gasoline and
other flammable vapors and liquids.
Caution: Do not obstruct the flow of
combustion and ventilation air.
Cleaning Surfaces
1. Wipe surfaces clean with mild dishwashing detergent or baking soda mixed with water.
2. For stubborn surfaces use a citrus based degreaser and a nylon scrubbing brush.
3. Rinse clean with water.
4. Allow to air dry.
Caution: Check and clean burner/
venturi tubes for insects and insect
nests. A clogged tube can lead to a fire beneath the grill.
Caution: Attempting to light the burner with the lid closed may cause
an explosion.
1. Make sure all labels, packaging and protective films have been removed from the outdoor
fireplace.
2. Make sure there are no obstructions of airflow to the burners. Spiders and insects can nest
within and clog the burner / venturi tube at the orifice. A clogged burner tube can lead to a
fire beneath the appliance.
2. Control knob must be in the
3. Connect LP gas tank per “Connect LP Gas Tank” instructions.
4. Turn LP gas tank valve to “OPEN”.
5. Push and turn control knob to
6. Press the
7. Release control knob after 45 seconds.
8. If ignition does not occur in 45 seconds, turn burner control knob
and repeat lighting procedure.
9. If igniter does not light burner:
a. Clear small area of lava rocks away from the burner.
b. Wearing heat reistant gloves, position a lit long match or long lit butane lighter near
(electronic igniter) button and hold for up to 5 seconds to light burner.
the side of the burner.
(OFF) position. (Figure 3)
(LOW).
(OFF), wait 5 minutes,
Before Storing
1. Turn control knob to (OFF) and LP gas tank valve to “CLOSED”.
2. Clean all surfaces.
3. Lightly coat the burners with cooking oil to prevent excess rusting.
4. If storing the outdoor fireplace indoors, disconnect the LP tank, see “Disconnect LP Gas Tank”
section, and leave the LP gas tank OUTDOORS.
5. Place the protective cap cover on the LP tank and store the tank outdoors in a well ventilated
area out of direct sunlight.
6. Cover outdoor fireplace with a durable vinyl cover designed to fit this unit.
7. Store in a cool and dry location away from children and pets.
Product Registration
For faster warranty service, register your product immediately at www.bluerhino.com or call
1.800.762.1142.
Limited Warranty
Blue Rhino Global Sourcing, Inc (“Vendor”) warrants to the original retail purchaser of this
product, and to no other person, that if this product is assembled and operated in accordance
with the printed instructions accompanying it, then for a period of one (1) year from the date
of purchase, all parts in such product shall be free from defects in material and workmanship.
Vendor may require reasonable proof of your date of purchase. Therefore, you should retain
your sales slip or invoice. This Limited Warranty shall be limited to the repair or replacement of
parts, which prove defective under normal use and service and which Vendor shall determine
in its reasonable discretion upon examination to be defective. Before returning any parts, you
should contact Vendor’s Customer Service Department using the contact information listed
below. If Vendor conrms, after examination, a defect covered by this Limited Warranty in any
returned part, and if Vendor approves the claim, Vendor will replace such defective part without
charge. If you return defective parts, transportation charges must be prepaid by you. Vendor will
return replacement parts to the original retail purchaser, freight or postage prepaid.
LP Gas Outdoor Fireplace Model No. GAD920SP
This Limited Warranty does not cover any failures or operating difculties due to accident,
abuse, misuse, alteration, misapplication, improper installation or improper maintenance or
service by you or any third party, or failure to perform normal and routine maintenance on
the product as set out in this owner’s manual. In addition, the Limited Warranty does not cover
damage to the nish, such as scratches, dents, discoloration, rust or other weather damage,
after purchase.
This Limited Warranty is in lieu of all other express warranties. Vendor disclaims all warranties
for products that are purchased from sellers other than authorized retailers or distributors,
including the warranty of merchantability or the warranty of tness for a particular purpose.
VENDOR ALSO DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT
LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE. VENDOR SHALL HAVE NO LIABILITY TO PURCHASER OR ANY THIRD PARTY FOR ANY
SPECIAL, INDIRECT, PUNITIVE, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. Vendor further
disclaims any implied or express warranty of, and assumes no responsibility for, defects in
workmanship caused by third parties.
This Limited Warranty gives the purchaser specic legal rights; a purchaser may have other
rights depending upon where he or she lives. Some jurisdictions do not allow the exclusion or
limitation of special, incidental or consequential damages, or limitations on how long a warranty
lasts, so the above exclusion and limitations may not apply to everyone.
Vendor does not authorize any person or company to assume for it any other obligation or
liability in connection with the sale, installation, use, removal, return, or replacement of its
equipment, and no such representations are binding on Vendor.
Blue Rhino Global Sourcing, Inc
Winston-Salem, North Carolina 27105 USA
1.800.762.1142
Contact 1.800.762.1142 for assistance. Do not return to place of purchase.
Troubleshooting
ProblemPossible CausePrevention/Cure
Make sure regulator is securely attached to the LP gas tank, turn LP gas tank
valve to “OPEN”
1. Turn LP gas tank valve to “CLOSED”
2. Wait 5 minutes for gas to clear
3. Follow “Checking for Leaks” in the owner’s manual
Check if LP gas tank is empty
A. If empty, replace or rell
B. If LP gas tank is not empty, refer to “Sudden drop in gas ow or reduced
ame height”
1. Turn LP gas tank valve to “CLOSED”
2. Wait 5 minutes for gas to clear
3. Follow “Checking for Leaks” in the owner’s manual
Turning the coupling nut about one-half to three quarters additional turn until
solid stop. Tighten by hand only-do not use tools.
1. Clear burner tubes
2. Check for bent or kinked hose
Burner will not light using ignitor
Burner will not light with match
LP gas tank valve is closed
LP gas tank is low or emptyReplace or refill LP gas tank
LP gas leak
Battery needs to be changedReplace the “AA” battery (follow assembly step for inserting battery)
Electrode and burners are wetWipe dry with cloth
Electrode cracked or broken - sparks at crackReplace electrode
Wire loose or disconnectedReconnect wire or replace electrode/wire assembly
Wire is shorting (sparking) between ignitor and electrode Replace ignitor wire/electrode assembly
Bad ignitorReplace ignitor
No gas flow
LP gas tank is low or emptyReplace or refill LP gas tank
LP gas leak
Coupling nut and regulator not fully connected
Obstruction of gas flow
Disengagement of burner to valveReengage burner and valve
Spider webs or insect nest in venturiClean venturi and burner tube
Burner ports clogged or blockedClean burner ports
Out of gasReplace or refill LP gas tank
page no.
11
Sudden drop in gas flow or reduced flame height
Irregular flame pattern, flame does not run the
full length of burner
Flame is yellow or orange
Flame blow out
Flashback (fire in burner tube(s))
Flame seems to lose heat when burning in cold
weather - temperature below 50ºF
For more assistance please visit us online at www.bluerhino.com or call 1.800.762.1142.
1. Turn control knob to “OFF
2. Wait 30 seconds and light outdoor replace.
3. If ames are still too low, reset the excessive ow safety device:
a. Turn control knob(s) “OFF
b. Turn LP gas tank valve to “CLOSED”
Excess flow; safety device may have been activated
Burner ports are clogged or blockedClean burner ports
New burner may have residual manufacturing oils.Burn outdoor fireplace for 15 minutes and reinspect
Spider webs or insect nest in venturiClean venturi
Poor alignment of valve to burner venturiAssure burner venturi is properly engaged with valve
High or gusting windsDo not use outdoor fireplace in high winds
Low on LP gasReplace or refill LP gas tank
Excess flow valve trippedRefer to “Sudden drop in gas flow or reduced flame height”
Burner and/or burner tubes are blockedClean burner and/or burner tubes
Ice has built up on the outside of the LP gas tank
because the vaporization process is too slow.
c. Disconnect regulator
d. Turn control knob to
e. Wait 1 minute
f. Turn control knob to “OFF
g. Reconnect regulator and leak check connections.
h. Slowly turn LP gas tank valve to “OPEN”
i. Wait 30 seconds and then light outdoor replace per “Lighting Instructions”
1. Turn LP gas tank valve to “CLOSED”
2. Turn control knob to “OFF
3. Replace with a spare LP gas tank
4. Reconnect LP gas tank per “Installing LP Gas Tank”
5. Leak check the connections
6. Light per “Lighting Instructions”
”
”