tricity bendix CH610W, CH520B, CH610B, CH520W Manual

0 (0)
Visor Cooker Hood - CH 520 and CH 610
Operating and Installation Instructions
Please refer to the sections in this booklet that apply to your particular model: Page
CONTENTS 1
WARNINGS 2
GENERAL 3
INSTALLATION INSTRUCTIONS ELECTRICAL CONNECTION 4
UNPACKING 5
POSITIONING 5
WALL FITTING 5
DUCTING FITTING 6
OPERATING INSTRUCTIONS 7
DO’S AND DON’TS 7
MAINTENANCE AND CLEANING WORKTOP LIGHTING 8
MAINTENANCE AND CLEANING FILTERS 8
HELP US TO HELP YOU 9
CONTENTS
DIMENSIONS CH520 Width cm 49.8
CH610 Width cm 59.8
Height cm 15.0
Depth cm 48.0
Depth with visor open cm 53.0
WEIGHT CH520 Gross kg 8.2
Net kg 7.2
CH610 Gross kg 8.7
Net kg 7.7
ELECTRICAL CONNECTION Voltage 220-240V ~ 50Hz
Fan 110W
Lamps 2x40W 80 W
Total Consumption 190W
PERFORMANCE Speed 1 2 3
Capacity m
3
/h 130 180 250
Capacity lt/sec 36 50 69
Pressure mmH
2
O10 1825
Noise level dbA 45 51 59
TECHNICAL SPECIFICATIONS
1
It is most important that this instruction
book should be retained with the appliance
for future reference. Should the appliance
be sold or transferred to another owner, or
should you move house and leave the
appliance always ensure that the book is
supplied with the appliance in order that
the new owner can be acquainted with the
functioning of the appliance and the
relevant warnings. Please ensure that you
have read the whole instruction book before
using the appliance and that you follow the
recommendations given.
These warnings are provided in the interest
of safety. They must be read carefully
before installing or using this appliance.
This appliance is designed to be operated by
adults. Children should not be allowed to
tamper with the controls or play with the
product.
It is dangerous to alter the specifications or
modify the product in any way.
Any installation work must be undertaken by
a qualified electrician or a competent person.
This product should be serviced by an
authorised Tricity Bendix Service Centre, and
only genuine Tricity Bendix spare parts should
be used.
Never leave frying pans unattended during use
as overheated fats and oils may catch fire.
Never do flambe cooking under this cooker
hood.
It is a possible fire hazard if the grease and
charcoal filter are not replaced as
recommended.
When used in the extraction mode the cooker
hood must not be connected to a flue which is
used for exhausting fumes from appliances
supplied with energy other than electric such
as a central heating flue or water heater.
If the room where the cooker hood is to be
used contains a fuel burning appliance such
as a central heating boiler then its flue must
be of the room sealed or balanced flue type.
If other types of flue or appliances are fitted
ensure that there is an adequate supply of air
to the room.
All installations must comply with the local
authorities requirements for the discharge of
exhaust air.
If the hood is installed for use above a gas
appliance then the provision for ventilation
must be in accordance with the Gas Safety
(Installation & Use) Regulations 1994 No.1886
and the relevant building regulations. Details
are contained in the following British Standard
Codes of Practise BS.6172 BS.5440 and
BS.6891 Current Edition.
The fan motor of this cooker hood incorporates
a thermal cut-out device which will operate if
the cooker hood is installed below the
minimum height recommended in this booklet,
or if the motor becomes overheated. If the
cut-out device is acti-vated, switch off the fan
motor and allow the cooker hood to cool.
The cut-out device will reset itself when the
fan motor has cooled significantly.
This cooker hood has been designed for
installation over an electric hotplate with a
maximum input of 7Kw or a gas hotplate
with a maximum input of 10Kw when fitted
in accordance with the heights
recommended in this booklet.
Under no circumstances should you attempt
to repair the appliance yourself. Repairs
carried out by an inexperienced person may
cause injury or more serious malfunctioning.
Refer to your local Tricity Bendix Service
Centre. Always insist on genuine Tricity Bendix
spare parts.
WARNINGS WARNINGS
2
This instruction book applies to the
following models:
Tricity Bendix CH520B Brown 50cm
Tricity Bendix CH520W White 50cm
Tricity Bendix CH610B Brown 60cm
Tricity Bendix CH610W White 60cm
This cooker hood is guaranteed and will
give lasting service. The guarantee is only
applicable if the hood has been installed in
accordance with the installation instructions
detailed in this booklet.
This cooker hood has been designed for
use fixed beneath a wall cabinet or directly
onto the wall using the special brackets
supplied and should be installed in
accordance with the following fitting
instructions.
The cooker hood can be used to extract
odours to the outside or to recirculate the
air within the kitchen after passing the
contaminated air through a cleansing
charcoal filter which is supplied as
standard.
The cooker hood is convertible to either
function by the movement of a change-over
slider control. This enables the cooker hood
when installed in the extraction mode, to be
converted to recircu-lation during the winter
months.
The installation instructions which follow
give instructions on how and where this
hood may be fitted. If already installed
check with the installer that all the
requirements have been met. If not then
draw these to the attention of the installer
who should be a qualified electrician or a
competent person.
Tricity Bendix disclaims all liability for any
damage or injury caused as a result of not
following the instructions contained in the
following text.
Width: CH520B - CH520W 498mm
Width: CH610B - CH610W 598mm
GENERAL INFORMATION ELECTRICAL CONNECTION
3
Before connecting to the mains supply ensure that
the mains voltage corresponds to the voltage on
the rating plate inside the cooker hood.
WARNING: THIS APPLIANCE MUST BE
EARTHED
This appliance is fitted with a 3 core mains supply
cable and should be permanently connected to
the electricity supply via a double-pole switch
having 3mm minimum contact gap on each pole.
A Switched Fuse Connection Unit to BS.1363 Part
4 (fitted with a 3A fuse), is a recommended mains
supply connection accessory to ensure compli-
ance with the Safety Requirements applicable to
fixed wiring instructions.
CONNECTION TO THE MAINS POWER
SUPPLY
Any permanent electrical installation must comply
with the latest I.E.E. Regulations and local
Electricity Board regulations. For your own safety
this should be undertaken by a qualified
electrician e.g. your local Electricity Board, or a
contractor who is on the roll of the National
Inspection Council for Electrical Installation
Contracting (NICEIC).
WARNING: INCORRECT INSTALLATION
COULD AFFECT THE SAFETY OF THIS
CHIMNEY HOOD.
DISCONNECT THE HOOD FROM THE MAINS
SUPPLY BEFORE CARRYING OUT ANY KIND
OF MAINTENANCE OR CLEANING.
This appliance conforms to BS.800:1988 and
EEC Directive 87/308 regarding suppression of
radio and television interference.