TP-Link TL-SG5428, TL-SG5412F Installation Guide

Business Networking Solution
Installation Guide
L2 Managed Switch
TL-SG5428/TL-SG5412F
COPYRIGHT & TRADEMARKS
Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks of their respective holders.
as translation, transformation, or adaptation without permission from TP-LINK TECHNOLOGIES CO., LTD. Copyright
© 2015 TP-LINK TECHNOLOGIES CO., LTD. All rights reserved.
http://www.tp-link.com
FCC STATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
CE Mark Warning
This is a class A product. In a domestic environment, this product may cause radio interference, in which case the
user may be required to take adequate measures.
Copyright & Trademarks
I
Related Document
The User Guide and CLI Reference Guide of the product are provided on the resource CD.
To obtain the latest product information, please visit the Official Website:
http://www.tp-link.com
About this Installation Guide
This Installation Guide describes the hardware characteristics, installation methods and the points that should be attended to during installation.
This Installation Guide is structured as follows:
Chapter 1 Introduction. This chapter describes the External Components of the Switch.
Chapter 2 Installation. This chapter illustrates how to install the Switch.
Chapter 3 Lightning Protection. This chapter illustrates how to prevent lightning
damage.
Chapter 4 Connection. This chapter illustrates how to do the physical connection of the Switch.
Chapter 5 Configuration. This chapter instructs you to configure the Switch via Web Interface and CLI commands.
Appendix A Troubleshooting.
Appendix B Hardware Specifications.
Related Document
II
Audience
Conventions
This Installation Guide is for:
Network Engineer
Network Administrator
Due to the similarity in the structure of the L2 Managed Switch series, in this Installation Guide we take TL-SG5428 as an example to illustrate Chapter 2 Installation, Chapter 3 Lightning Protection and Chapter 4 Connection.
This guide uses the specific formats to highlight special messages. The following table lists the notice icons that are used throughout this guide.
Remind to be careful. A caution indicates a potential which may
result in device damage.
Remind to take notice. The note contains the helpful
information for a better use of the product.
Audience
III
Contents
Chapter 1 Introduction ———————————— 01
1.1 Product Overview .........................................01
1.2 Appearance .................................................01
Chapter 2 Installation ————————————— 04
2.1 Package Contents .........................................04
2.2 Safety Precautions ........................................04
2.3 Installation Tools ..........................................06
2.4 Product Installation ......................................06
Chapter 3 Lightning Protection ———————— 08
3.1 Cabling Reasonably ......................................08
3.2 Connect to Ground .......................................10
3.3 Equipotential Bonding ...................................11
3.4 Use Lightning Arrester ..................................12
Chapter 4 Connection ————————————— 13
4.1 Ethernet Port ...............................................13
4.2 SFP Port ......................................................13
4.3 Console Port ................................................15
4.4 Verify Installation .........................................15
4.5 Power On ..................................................15
4.6 Initialization .................................................16
Chapter 5 Conguration ———————————— 17
5.1 Congure the switch via GUI .........................17
5.2 Congure the switch Using CLI ......................18
Appendix A Troubleshooting —————————— 20
Appendix B Hardware Specications —————— 21
Contents
IV
L2 Managed Switch
Chapter 1 Introduction
1.1 Product Overview
TL-SG5428 and TL-SG5412F are Gigabit Ethernet switching products recently developed by TP-LINK. TL-SG5428 possesses 24 RJ45 ports and 4 SFP slots, while TL-SG5412F characterizes with 12 SFP slots and 4 RJ45 ports. The SFP slot enables remote connection with SFP slots on other devices through SFP module and fiber. TL-SG5412F is compatible with all kinds of gigabit SFP modules. Here you are recommended to choose gigabit SFP module produced by TP-LINK, which can perfectly extend your network and enlarge the bandwidth. TL-SG5412F is your first choice to extend the originally large and medium-sized network.
Designed for workgroups and departments, TL-SG5428/TL-SG5412F from TP-LINK provides wire-speed performance and full set of layer 2 management features. It provides a variety of service features and multiple powerful functions with high security.
The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. ACL, 802.1x and Dynamic ARP Inspection provide robust security strategies. QoS and IGMP snooping/filtering optimize voice and video application. Link aggregation (LACP) increases aggregated bandwidth, optimizing the transport of business critical data. Web, CLI (Console Port, Telnet, SSH), SNMP and RMON bring abundant management policies. TP-LINK JetStream L2 Managed Switch integrates multiple functions with excellent performance, and is friendly to manage, which can fully meet the need of the users demanding higher networking performance.
1.2 Appearance
The front panel of TL-SG5428 is shown as the following figure.
The front panel of TL-SG5412F is shown as the following figure.
Front Panel
TL-SG5428
LEDs
10/100/1000Mbps RJ45 Port
SFP Port
Console Port
Figure 1-1 Front Panel of TL-SG5428
LEDs
SFP Port
10/100/1000Mbps RJ45 Port
Console Port
Figure 1-2 Front Panel of TL-SG5412F
01
Introduction
LEDs ( for TL-SG5428 )
LED Status Indication
On The switch is powered on
PWR
SYS
1000Mbps
Link /Act
Off The switch is powered off or power supply is abnormal
Flashing Power supply is abnormal
Flashing The switch works properly
On/Off The switch works improperly
On A device is linked to the corresponding port and running at 1000Mbps
Off A 10/100Mbps device or no device is linked to the corresponding port
On A device is linked to the corresponding port and running properly
Flashing Data is being transmitted or received
Off No device is linked to the corresponding port
LEDs ( for TL-SG5412F )
LED Status Indication
PWR
SYS
10/100/10 00 BASE-T
1000Mbps
Link /Act
On The switch is powered on
Off/Flashing The switch is powered off or power supply is abnormal
Flashing The switch works properly
On/Off The switch works improperly
On
Green
Flashing
On
Yel low
Flashing
Off No device is linked to the corresponding port
On
Off
On
Flashing
Off
A 1000Mbps device is linked to the corresponding port and there is no activity
A 1000Mbps device is linked to the corresponding port and data is being transmitted or received
A 10/100Mbps device is linked to the corresponding port and there is no activity
A 10/100Mbps device is linked to the corresponding port and data is being transmitted or received
A 1000Mbps device is linked to the corresponding port
No device or a 10/100Mbps device is linked to the corresponding port
A 1000Mbps device is linked to the corresponding port but there is no activity
A 1000Mbps device is linked to the corresponding port and data is being transmitted or received
No device or a 10/100Mbps device is linked to the corresponding port
L2 Managed Switch
Note:
The SFP port can work at 1000Mbps mode only, and the Link/Act LED of SFP port will lighten only when a 1000Mbps device is connected to the corresponding port.
For TL-SG5428, the SFP ports are individual, while for TL-SG5412F, the four RJ45 ports combind with four SFP ports are combo ports, which means that the SFP port with the corresponding RJ45 port cannot work simultaneously. For detailed information about combo port, please refer to
4.2 SFP Port
.
Introduction
02
L2 Managed Switch
Port Feature
Model 10/100/1000 Mbps RJ45 Port SFP Port Console Port
TL-S G 5 42 8 24 4 1
TL-S G 5 412F 4 12 1
10/100/1000Mbps RJ45 Port
Designed to connect to the device with a bandwidth of 10Mbps, 100Mbps or 1000Mbps. For TL-SG5428, each 10/100/1000Mbps RJ45 port has a corresponding 1000Mbps LED and Link/Act LED. But for TL-SG5412F, each 10/100/1000Mbps RJ45 port has a corresponding 10/100/1000BASE-T LED.
SFP Port
Designed to install the SFP module. The SFP ports of these two devices support 1000Mbps SFP module connection only. Each has a corresponding 1000Mbps LED and Link/Act LED.
Console Port
Designed to connect with the serial port of a computer or terminal for monitoring and configuring the Switch.
Rear Panel
Due to the similarity of TL-SG5428 and TL-SG5412F in the rear panel, here TL-SG5428 is used as an example.
Grounding Terminal
Power Socket
Figure 1-3 Rear Panel of TL-SG5428
Grounding Terminal
The Switch already comes with lightning protection mechanism. You can also ground the Switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed information, please refer to Chapter 3 Lightning Protection.
Power Socket
Connect the female connector of the power cord here, and the male connector to the AC power outlet. Please make sure the voltage of the power supply meets the requirement of the input voltage (100-240V~ 50/60Hz).
03
Caution: Please use the provided power cord.
Introduction
Chapter 2 Installation
TL-SG5428
2.1 Package Contents
Make sure that the package contains the following items. If any of the listed items is damaged or missing, please contact your distributor.
L2 Managed Switch
One Switch
One Resource CD
2.2 Safety Precautions
To avoid any device damage and bodily injury caused by improper use, please observe the following rules.
Safety Precautions
Keep the power off during the installation.
Wear an ESD-preventive wrist strap, and make sure that the wrist strap has a good skin contact and is well grounded.
Use only the power cord provided with the switch.
Make sure that the supply voltage matches the specifications indicated on the rear panel of the switch.
Ensure the vent hole is well ventilated and unblocked.
Do not open or remove the cover of the switch.
Before cleaning the device, cut off the power supply. Do not clean it by the waterish cloth, and never use any other liquid cleaning method.
One Power Cord and One Console Cable
Two mounting brackets and
the ttings
This Installation Guide
Site Requirements
To ensure normal operation and long service life of the device, please install it in an environment that meets the requirements described in the following subsection.
Temperature/Humidity
ȭ
TL-SG5428
ȭ
Installation
04
Loading...