EN
7
EN
6
Function Operation Display Remarks
2: The scale will keep working
for 30 minutes with stable weighing value displayed and then
switches off automatically. Press
to change.
Addition condition
Press
AS 1 0: Adding allowed when unsta-
ble
1: Adding not allowed when
unstable
Press to change.
Sets units
Press
Unt 0 0: kg
1: lb
Press to change.
Initial on zero
range setup
Press
o 20 Percent of capacity
Press to change.
Clear
Press
CLEAr
Press to save clear operation then quit.
Press to quit without save.
POWER OFF
After the weighing operation, turn off the scale by using the power switch on the
back of the scale.
5. BATTERY CHARGING
It adopts maintenance-free rechargeable battery (6V/4.5Ah) and smart charger
(DC6V/1000mA).
The LOB indicator will be on if there is low power. The battery needs to be charged
now. The scale, however, can continue to operate for about 5 hours without charging.
After the LOB indicator is ON for several hours without charging or if the battery is
running low, the scale will be switching off automatically. It will take about 5 hours to
fully charge the battery.
After battery is fully charged, with a blank display, that indicates that either there is a
difculty in battery charging or a damaged battery. Please contact supplier for repair
or replacement.
To prolong the battery life, we suggest you charge the battery not less than once per
week. If the scale needs not to be charged for a long time, you should charge it not
less than once per week. To avoid any damage to the battery, please charge it correctly. Additionally, we suggest you switch off the scale in order to shorten the charging
time.
6. MAINTENANCE AND USE
Do not overload the scale in order to prevent damage to the force transducer inside
the scale.
Please check the scale frequently to insure safe use. The basic checking list contains:
• Whether the screw has come loose.
• Whether the hook or shackle or any other component is cracked or distorted.
• If the mechanical components showing signs of metal fatigue or defects.
• Whether the pin is off or the components are lost.
If there is any sign of the above mentioned conditions, please send the scale or components back to the manufacturer for repair or exchange before using the scale again.
Avoid any impact to the display panel.
Do not use the scale under wet or heavily polluted conditions.
7. CALIBRATION
Steps Operation Display Remarks
1
Hold on
to switch on the scale
00000 1st step of calibration.
Password is required.
2
Press to select the desired number, press to shift digit
****** ****** is the pass-
word
3
After entering password, press
SPEN There should be no
load on the scale
4
Press
9500 9500 is the encode
when zeroing load
5
Press
00000 Wait until the codes
become stabilized and
press [ADD/INPUT]
6
Press to change to the desired
number for the standard weight, press
to shift digits
03000 03000 is the standard
weight of 3000kg to
be loaded.
7 After the standard weight is loaded,
press
77683 77683 is the encode
number of standard
weight - 3000kg.
8
Press
3000
Calibration is completed. The scale is in
weighing mode. The
current weight load is
displayed.