Sony SX-M100 User Manual

3-759-749-14 (1)
Conference System
Model:
SX-M100 SX-C100A/SX-C150 SX-D100A/SX-D150 SX-T100
Control Unit
Chairman’s Unit
Delegate’s Unit
Operating Instructions
Before operating the unit, please read this manual thoroughly and retain it for future reference.
© 1994 by Sony Corporation
Owner’s Record
The model and serial numbers are located on the rear of the SX-M100 and on the bottom of the SX-C100A/ D100A/T100. Record the serial numbers in the spaces provided below. Refer to them whenever you call upon your Sony dealer regarding these products.
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.
Model No. SX-M100 Serial No.______________ Model No. SX-C100A/C150 Serial No.______________ Model No. SX-D100A/D150 Serial No.______________ Model No. SX-T100 Serial No.______________
WARNING
To prevent fire or shock hazard, do not expose the unit to rain or moisture.
For the customers in the U.S.A.
This symbol is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
The shielded interface cable recommended in this manual must be used with this equipment in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules.
For the customers in Canada
This Class A digital apparatus complies with Canadian ICES-003.
Pour les utilisateurs au Canada
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
NOTICE FOR THE CUSTOMERS IN THE UNITED KINGDOM
WARNING THIS APPARATUS MUST BE EARTHED
IMPORTANT
The wires in this mains lead are coloured in accordance with the following code:
Green-and-yellow: Earth Blue: Neutral
Brown: Live As the colours of the wires in the mains lead of this apparatus may not correspond with the coloured markings identifying the terminals in your plug proceed as follows: The wire which is coloured green-and-yellow must be connected to the terminal in the plug which is marked by the letter E or by the safety earth symbol Y or coloured green or green-and-yellow. The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black. The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.
WARNING
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
2
VORSICHT
Um Feuergefahr und die Gefahr eines elektrischen Schlages zu vermeiden, darf das Gerät weder Regen noch Feuchtigkeit ausgesetzt werden.
Für Kunden in Deutschland
Dieses Produkt kann im kommerziellen und in begrenztem Maße auch im Industriellen Bereich eingesetzt werden. Dies ist eine Einrichtung, welche die
Funk-Entstörung nach Klasse B besitzt.
Table of Contents
Outline .......................................................................................................... 4
Features .................................................................................................... 4
System Configuration .............................................................................. 5
Location and Function of Parts and Controls .......................................... 6
SX-M100 Control Unit ............................................................................ 6
SX-C100A/C150/SX-D100A/D150 Chairman’s Unit/Delegate’s Unit .. 9
SX-T100 Telephone Coupler ................................................................. 13
Setting Up the System ............................................................................... 14
Precautions ............................................................................................. 14
System Connection ................................................................................ 14
Turning On the Power of the System..................................................... 16
Preparing the Control Unit ..................................................................... 17
Operation During a Conference .............................................................. 19
Operation Performed by the Chairman and Delegates .......................... 19
Taking Part in a Conference via a Telephone ........................................ 20
Troubleshooting Guide ............................................................................. 21
Specifications ............................................................................................. 22
3
Outline
Features
The SX-M100 conference system is a flexible discussion system that can be configured with the versatile units introduced below. The standard system supports a conference of up to 60 delegates. Connecting the SX-E120 Expansion Unit (not supplied) allows the system to support up to 120 delegates. The SX-T100 Telephone Coupler (not supplied) allows the use of a telephone line during a conference. By using the telephone, a person not actually in the conference hall can also take part in the conference.
The standard system consists of the following units.
SX-M100 Control Unit This unit controls the conference system. The control unit can be mounted in a 19-inch rack.
Chairmans Unit/Delegates Unit
SX-C100A/SX-D100A Chairmans Unit/Delegates Unit: Desktop
type. You can move these units freely in the conference room.
– SX-C150/SX-D150 Chairmans Unit/Delegates Unit: Desk-mounted type.
These units are fixed to the desks. These units feature both a microphone and speaker. Use the above combination of the chairmans unit and delegates unit.
SX-T100 Telephone Coupler This coupler is used to connect the control unit to a telephone line. Using this coupler allows a person to take part in a conference from a remote location, even from overseas.
In addition to the units described above, the following optional units are available.
SXA-120 Expansion Board
The board is designed to allow the expansion of the systems functions. Installing this board in the control unit allows the following function expansion units to be connected.
SX-E120 Expansion Unit
SX-8300/SX-S100 Microphone Control Panel
Used to enable or disable delegates microphones. When multiple SX-8300 microphone control panels are used, the power interface unit is required. When the SX-S100 microphone control panels are used, they are connected using only the connecting cables.
For detailed information on the power interface unit, contact your Sony dealer.
Personal computer
For details of the SXA-120 Expansion Board, refer to the manual supplied with the expansion board.
4
System Configuration
The figure below shows an example of the conference system.
Conference seats
Conference hall
Operator section
SX-C100A Chairmans Unit
SX-D100A Delegates Unit
a)
SX-T100 Telephone Coupler
SX-M100 Control Unit
MIC/LINE 1 MIC/LINE 2
5
4
6
3
7
8
2
9
1
010
3
2
1
5
4
010
ORIGINAL
D/C UNIT SP
D/C UNIT MIC
MIC/LIMIT
DIRECT ACCESS
5
4
4
6
6
3
3
7
7
8
8
2
2
9
9
1
1
010
010
SEAT ASIGN
5
6
ON/OFF
ON/OFF
START/END
7
8
9
POWER
ON
I
PHONES
OFF
O
MONITOR
5
4
6
3
7
8
2
9
1
MIN MAX
VU
MONITOR
a) You can also use other combination of
a)
the SX-C150/SX-D150.
System configuration
5
Location and Function of Parts and Controls
SX-M100 Control Unit
Front panel
1POWER switch
PHONES connector
2
POWER
ON
I
OFF
O
PHONES
Rear panel
9 EXT UNIT IN/OUT connectors
EXT UNIT
EXT IN-2
MIC LINE
LINEMIC
IN
OUT
3MONITOR volume control
4Level meter
MONITOR
5
4
6
3
7
8
2
9
1
MIN MAX
0 EXT IN-1 MIC/LINE connectors and MIC/LINE switch
EXT IN-1
MIC
MIC
LINE
DELEGATE'S/CHAIRMAN'S UNIT
VU
MONITOR
MIC/LINE 1 MIC/LINE 2
5
4
6
3
2
1
010
3
7
8
2
9
1
5
4
010
LINE OUT
connector
LINE OUT
@TELEPHONE COUPLER
LINE
1234
1
2
5Volume controls
6MIC LIMIT ON/OFF button
7DIRECT ACCESS
ON/OFF button
ORIGINAL
D/C UNIT MIC
4
6
3
7
8
2
9
1
010
!™TELEPHONE COUPLER connector
D/C UNIT SP
MIC/LIMIT
5
5
4
6
7
9
8
3
2
1
010
6
7
8
9
ON/OFF
DIRECT ACCESS
ON/OFF
8SEAT ASSIGN
START/END button
SEAT ASIGN START/END
AC IN
EXT IN-2 MIC/LINE
connectors and MIC/LINE switch
DELEGATES/CHAIRMANS UNIT
y terminal
!∞
AC IN connector
connectors
SX-M100 Control Unit
6
1 POWER switch
Setting the switch to ON (1 ) turns the power on. The level meter will light. Setting the switch to OFF (
o) turns the power off.
2 PHONES connector (stereo phone jack)
Connect 8-ohm stereo or monaural headphones. Note that the output is monaural even when stereo headphones are connected.
3 MONITOR volume control
Adjusts the volume of the headphones.
MIC (microphone) LIMIT ON: Press this button
to set the microphone to the speakers number limitation mode. The button indicator lights. Setting this mode allows the microphones of up to five delegates units to be live at the same time.
MIC (microphone) LIMIT OFF: Press the button
again to set the microphone to the speaker’s number unlimitation mode. The button indicator goes out. Setting this mode allows the microphones of all delegates units to be live at the same time.
4 Level meter
Indicates the level of the audio signal output to the LINE OUT !¡, TELEPHONE COUPLER !™ and DELEGATES/CHAIRMANS UNIT connectors.
5 Volume controls
Used to adjust the level of the following sound. D/C UNIT SP volume control: Adjusts the level
of the audio signal output to the chairman’s unit/delegates unit.
D/C UNIT MIC volume control: Adjusts the
input level of the audio signal sent from the microphones on the chairmans units and delegates units.
MIC/LINE 1 volume control: Adjusts the input
level of the signal input through the EXT IN-1 MIC or LINE connector.
MIC/LINE 2 volume control: Adjusts the input
level of the signal input through the EXT IN-2
MIC or LINE connector. When the MIC/LINE switch of the EXT IN-1 or EXT IN-2 connector is set to LINE, the input level of the signal input through the LINE connector can be adjusted. When the MIC/LINE switch of the EXT IN-1 or EXT IN-2 connector is set to MIC, the input level of the signal input through the MIC connector can be adjusted.
6 MIC (microphone mode) LIMIT ON/OFF
button
Selects the microphone mode for the delegate’s units. The microphone of the chairmans unit remains live regardless of the setting of this button.
7 DIRECT ACCESS ON/OFF button
This button is effective only when the SXA-120 Expansion Board (not supplied) is installed and the SX-8300/SX-S100 Microphone Control Panel is connected to the control unit. While the SX-8300 is not connected, this button indicator lights, even though it is not operative. The button indicator does not go out even if you press this button.
8 SEAT ASSIGN START/END button
This button is effective only when the SXA-120 Expansion Board (not supplied) is installed and the SX-8300/SX-S100 Microphone Control Panel is connected to the control unit for performing seat assignment. While the SX-8300 Microphone Control Panel is not connected, the button indicator does not light even if you press the button.
For details of the functions and how to use the DIRECT ACCESS ON/OFF and SEAT ASSIGN START/END buttons, refer to the manuals supplied with the SXA-120 Expansion Board.
9 EXT UNIT IN/OUT (external unit input/
output) connectors (phone jack)
Connect to the howling suppressor unit or filter unit (not supplied).
Notes
Be sure to connect both the IN and OUT connectors. Connecting only one of the two connectors results in incorrect operation of the unit.
When it is not necessary to use the howling suppressor or filter unit, disconnect cables from both connectors.
7
Location and Function of Parts and Controls
0
EXT IN-1 MIC/LINE (external 1 microphone/ line signal input) connectors and MIC/LINE switch
EXT IN-1 MIC/LINE connectors
Accept an external audio signal. MIC connector (XLR type): Connect a rostrum
or conference hall microphone.
Note
When you use a connecting cable with an XLR connector, pin No.1 and the case (metal part) of which are connected, noise may be picked up.
LINE connector (phono jack): Connect to
external equipment such as audio equipment.
MIC/LINE switch
Selects the signal input to the EXT IN-1 connector. MIC: Set the switch to this position when a
microphone is connected.
LINE: Set the switch to this position when an item
of audio equipment is connected.
DELEGATES/CHAIRMAN’S UNIT
connectors (20-pin multi-connectors)
Connect to the SX-C100A/SX-C150/SX-D100A/ SX-D150 Chairmans Unit/Delegates Unit. The same signal is output from four connectors. Up to 15 SX-C100A/D100A units can be connected to each of the four connectors. Thus, up to 60 SX­C100A/SX-C150/SX-D100A/SX-D150 units can be connected.
!∞y (signal ground) terminal
Ground if necessary.
AC IN (AC power input) connector
Connect the unit to an AC power source by means of the supplied AC power cord.
LINE OUT (line output) connectors
(phono jacks)
Supply the signal from the chairmans unit/ delegates unit, that from the rostrum or conference hall microphone. There are two connectors. Use these connectors when recording the output to a tape recorder or when sending the line output to the monitor system transmitter by means of an infrared or induction-based system.
!™ TELEPHONE COUPLER connector (6-pin
multi-connector)
Connect to the SX-T100 telephone coupler (not supplied).
EXT IN-2 MIC/LINE (external 2 microphone/ line signal input) connectors and MIC/ LINE (microphone/line signal select) switch
EXT IN-2 MIC/LINE connectors
Input an external audio signal. MIC connector (phone jack): Connect a rostrum
or conference hall microphone.
LINE connector (phono jack): Connect to
external equipment such as audio equipment.
MIC/LINE switch
Selects the signal input to the EXT IN-2 connector. MIC: Set the switch to this position when a
microphone is connected.
LINE: Set the switch to this position when an item
of audio equipment is connected.
8
Loading...
+ 16 hidden pages