SMA MD.485-US-40, PC-485.BG1 Installation Manual

Page 1
Installation Manual
SMA RS485 MODULE
MD.485-US-40 (PC-485.BG1)
MD485-US-40-IA-en-11 | Version 1.1ENGLISH
Page 2

Legal Provisions

SMA Solar Technology AG
Legal Provisions
SMA Solar Technology AG makes no representations or warranties, express or implied, with respect to this documentation or any of the equipment and/or software it may describe, including (with no limitation) any implied warranties of utility, merchantability, or fitness for any particular purpose. All such representations or warranties are expressly disclaimed. Neither SMA Solar Technology AG nor its distributors or dealers shall be liable for any indirect, incidental, or consequential damages under any circumstances.
The exclusion of implied warranties may not apply in all cases under some statutes, and thus the above exclusion may not apply.
Specifications are subject to change without notice. Every attempt has been made to make this document complete, accurate and up-to-date. Readers are cautioned, however, that product improvements and field usage experience may cause SMA Solar Technology AG to make changes to these specifications without advance notice, or per contract provisions in those cases where a supply agreement requires advance notice. SMA Solar Technology AG shall not be responsible for any damages, including indirect, incidental or consequential damages, caused by reliance on the material presented, including, but not limited to, omissions, typographical errors, arithmetical errors or listing errors in the content material.
Trademarks
All trademarks are recognized, even if not explicitly identified as such. Missing designations do not mean that a product or brand is not a registered trademark.
SMA Solar Technology AG
Sonnenallee 1 34266 Niestetal Germany Tel. +49 561 9522-0 Fax +49 561 9522-100 www.SMA.de Email: info@SMA.de Status: 9/24/2018 Copyright © 2018 SMA Solar Technology AG. All rights reserved.
Installation ManualMD485-US-40-IA-en-112
Page 3
SMA Solar Technology AG

Table of Contents

Table of Contents
1 Information on this Document................................................. 4
1.1 Validity........................................................................................................................ 4
1.2 Target Group.............................................................................................................. 4
1.3 Levels of warning messages ...................................................................................... 4
1.4 Symbols in the Document .......................................................................................... 4
1.5 Typographies in the document.................................................................................. 5
1.6 Designation in the document..................................................................................... 5
1.7 Additional Information ............................................................................................... 5
2 Safety ........................................................................................ 6
2.1 Intended Use .............................................................................................................. 6
2.2 IMPORTANT SAFETY INSTRUCTIONS.................................................................... 7
3 Scope of Delivery ..................................................................... 9
4 Product Overview .................................................................... 10
4.1 SMA RS485 Module................................................................................................. 10
4.2 Type Label .................................................................................................................. 10
5 Mounting................................................................................... 12
5.1 Mounting position ...................................................................................................... 12
5.2 Installing the Module ................................................................................................. 12
6 Connection ................................................................................ 14
6.1 Preparing the Connection Cable............................................................................... 14
6.2 Inserting the Cables ................................................................................................... 15
6.3 Connecting the Cable................................................................................................ 15
7 Decommissioning ..................................................................... 17
7.1 Removing the Module................................................................................................ 17
7.2 Packing the Product for Shipment ............................................................................. 18
7.3 Disposing of the Product............................................................................................ 18
8 Technical Data .......................................................................... 19
9 Compliance Information .......................................................... 20
10 Contact...................................................................................... 21
Installation Manual MD485-US-40-IA-en-11 3
Page 4

1 Information on this Document

SMA Solar Technology AG
1 Information on this Document

1.1 Validity

This document is valid for:
• SMA RS485 (MD.485-US-40) with assembly designation "PC-485.BG1" from hardware version A1

1.2 Target Group

The tasks described in this document must only be performed by qualified persons. Qualified persons must have the following skills:
• Knowledge of how an inverter works and is operated
• Training in how to deal with the dangers and risks associated with installing, repairing and using electrical devices and installations
• Training in the installation and commissioning of electrical devices and installations
• Knowledge of all applicable laws, standards and directives
• Knowledge of and compliance with this document and all safety information

1.3 Levels of warning messages

The following levels of warning messages may occur when handling the product.
DANGER
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
Indicates a situation which, if not avoided, can result in property damage.

1.4 Symbols in the Document

Symbol Explanation
Information that is important for a specific topic or goal, but is not safety-rele­vant
Indicates a requirement for meeting a specific goal
Desired result
Installation ManualMD485-US-40-IA-en-114
Page 5
SMA Solar Technology AG
Symbol Explanation
A problem that might occur
Example
1 Information on this Document

1.5 Typographies in the document

Typography Use Example
bold
>
[Button] [Key]
• Messages
• Terminals
• Elements on a user interface
• Elements to be selected
• Elements to be entered
• Connects several elements to be selected
• Button or key to be selected or pressed
• Connect the insulated conductors to the terminals X703:1 to X703:6.
• Enter 10 in the field Minutes.
• Select Settings > Date.
• Select [Enter].

1.6 Designation in the document

Complete designation Designation in this document
PV system PV system
SMA RS485 Module Module, product

1.7 Additional Information

Title and information content Type of information
"RS485 Cabling Plan" Installation Manual
Installation Manual MD485-US-40-IA-en-11 5
Page 6

2 Safety

SMA Solar Technology AG
2 Safety

2.1 Intended Use

The SMA RS485 Module enables SMA inverters to establish wired RS485 communication. The SMARS485Module enables SMA inverters of type "SBx.x-1SP-US-40" to establish
communication between the inverter and the energy meter according to ANSIC12.20 of the SMARevenueGradeMeterKit. The SMARS485 module can be used in SMA inverters of type "SBx.x-1SP-US-40" only to establish this communication. The setup of a cable-connected RS485 communication to other units is not supported.
The product must only be installed in the following SMA inverters:
• STP50-US-40 (SunnyTripowerCORE1-US)
• STP33-US-41 (SunnyTripowerCORE1-US)
• STP50-US-41 (SunnyTripowerCORE1-US)
• STP62-US-41 (SunnyTripowerCORE1-US)
• SB3.0-1SP-US-40 (Sunny Boy 3.0-US)
• SB3.8-1SP-US-40 (Sunny Boy 3.8-US)
• SB5.0-1SP-US-40 (Sunny Boy 5.0-US)
• SB6.0-1SP-US-40 (Sunny Boy 6.0-US)
• SB7.0-1SP-US-40 (Sunny Boy 7.0-US)
• SB7.7-1SP-US-40 (Sunny Boy 7.7-US) The inverter still complies with the standard after the product has been installed. All components must remain within their permitted operating ranges and their installation
requirements at all times. The product is approved for the US and Canadian market. Use this product only in accordance with the information provided in the enclosed documentation
and with the locally applicable laws, regulations, standards and directives. Any other application may cause personal injury or property damage.
Alterations to the product, e.g. changes or modifications, are only permitted with the express written permission of SMA. Unauthorized alterations will void guarantee and warranty claims and in most cases terminate the operating license. SMA shall not be held liable for any damage caused by such changes.
Any use of the product other than that described in the Intended Use section does not qualify as the intended use.
The enclosed documentation is an integral part of this product. Keep the documentation in a convenient place for future reference and observe all instructions contained therein.
This document does not replace and is not intended to replace any local, state, provincial, federal or national laws, regulations or codes applicable to the installation, electrical safety and use of the product. SMA assumes no responsibility for the compliance or non-compliance with such laws or codes in connection with the installation of the product.
The type label must remain permanently attached to the product.
Installation ManualMD485-US-40-IA-en-116
Page 7
SMA Solar Technology AG
2 Safety

2.2 IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS This section contains safety information that must be observed at all times when working on or with
the product. The product has been designed and tested in accordance with international safety requirements. As
with all electrical or electronical devices, there are residual risks despite careful construction. To prevent personal injury and property damage and to ensure long-term operation of the product, read this section carefully and observe all safety information at all times.
DANGER
Danger to life due to electric shock when live components or cables of the inverter are touched
High voltages are present in the conductive components or cables of the inverter. Touching live parts and cables of the inverter results in death or lethal injuries due to electric shock.
• Disconnect the inverter from voltage sources and make sure it cannot be reconnected before working on the device.
• Wear suitable personal protective equipment for all work on the product.
NOTICE
Damage to the enclosure seal in subfreezing conditions
If you open the inverter when temperatures are below freezing, the enclosure seals can be damaged. This can lead to moisture entering the inverter.
• Only open the inverter if the ambient temperature is not below -5°C (23°F).
• If a layer of ice has formed on the enclosure seal when temperatures are below freezing, remove it prior to opening the inverter (e.g. by melting the ice with warm air). Observe the applicable safety regulations.
NOTICE
Damage to the product due to sand, dust and moisture ingress
Sand, dust and moisture penetration can damage the product and impair its functionality.
• Only open the inverter if the humidity is within the thresholds and the environment is free of sand and dust.
• Do not open the inverter during a dust storm or precipitation.
• Close tightly all enclosure openings.
• Only use listed rain-tight or liquid-tight conduit fittings to attach the conduits to the product.
NOTICE
Damage to the inverter or product due to electrostatic discharge
Touching electronic components can cause damage to or destroy the inverter or the product through electrostatic discharge.
• Ground yourself before touching any component.
Installation Manual MD485-US-40-IA-en-11 7
Page 8
2 Safety
SMA Solar Technology AG
Electrical installations (for North America)
All installations must conform with the laws, regulations, codes and standards applicable in the jurisdiction of installation (e.g. National Electrical Code® ANSI/NFPA 70 or Canadian
Electrical Code® CSA-C22.1.).
• Before connecting the inverter to the utility grid, contact your local grid operator. The electrical connection of the inverter must be carried out by qualified persons only.
• Ensure that the cables or conductors used for electrical connection are not damaged.
Installation ManualMD485-US-40-IA-en-118
Page 9
SMA Solar Technology AG
BA C D
FE

3 Scope of Delivery

3 Scope of Delivery
Check the scope of delivery for completeness and any externally visible damage. Contact your distributor if the scope of delivery is incomplete or damaged.
Figure 1: Components included in the scope of delivery
Position Quantity Designation
A 1 Module
B 1 Fastening screw (M5, TX25)
C 2 4-pole terminal block
D 1 Terminator
E 2 Copper foil
F 1 Quick Reference Guide
Installation Manual MD485-US-40-IA-en-11 9
Page 10

4 Product Overview

F
A
D D
C
B
B
E
PC-485.BG1 XXXXX
XX
A
B
C
SMA Solar Technology AG
4 Product Overview

4.1 SMA RS485 Module

The SMA RS485 Module enables SMA inverters to establish wired RS485 communication.
Design of the Module
Figure 2: Design of the module
Position Explanation
A Opening for the fastening screw
B Openings for the guide pins of the communication assembly
C Jacks for connecting the 4-pole terminal blocks
D Shield clamps
E Type label
F Connector strip on the back of the module for connection to the
communication assembly in the inverter

4.2 Type Label

The type label clearly identifies the product. The type label is located on the front of the product.
Figure 3: Design of the type label
Position Explanation
Installation ManualMD485-US-40-IA-en-1110
A Device type
B Serial number
C Hardware version
Page 11
SMA Solar Technology AG
4 Product Overview
You will require the information on the type label to use the product safely and when seeking customer support from Service (see Section10 "Contact", page21).
Installation Manual MD485-US-40-IA-en-11 11
Page 12

5 Mounting

DISPLA
Y
BAT
Max. 30V DC
USB
FCC ID: SVF-KP IC: 9440A-KP20
MFR
A
B
X1
X2
A
B
C
SMA Solar Technology AG
5 Mounting

5.1 Mounting position

Figure 4: Communication assembly in the inverter with mounting position for the module
Position Designation
A Communication assembly
B
C
* Production resources SMA recommends using module slot M1 for the module.
Module slot M1*
Module slot M2

5.2 Installing the Module

NOTICE
Damage to the inverter due to moisture ingress during electrical installation
• Never open the inverter when it is raining or snowing, or the humidity is over 95%.
• For attaching the conduits to the enclosure, only use UL-listed rain-tight conduit fittings for wet locations.
• Seal all unused openings tightly.
Maximum number of modules per inverter
You can only use a maximum of one module of the same device type per inverter.
Installation ManualMD485-US-40-IA-en-1112
Page 13
SMA Solar Technology AG
CLICKCLICK
Procedure:
1.
DANGER
Danger to life due to high voltages of the PV array
When exposed to sunlight, the PV array generates dangerous DC voltage, which is present in the DC conductors and the live components of the inverter. Touching the DC conductors or the live components can lead to lethal electric shocks.
• Prior to performing any work on the inverter, always disconnect the inverter from voltage sources on the AC and DC sides as described in the inverter manual. When doing so, note that even if the DC load-break is switched off, there will be dangerous direct voltage present in the DC conductors of the inverter.
2. Remove the enclosure lid of the DC Connection Unit. Unscrew all screws with a Torx screwdriver (TX25) and remove the enclosure lid carefully forward.
3. Set the screws and the enclosure lid aside and store safely.
4. Install the module at the desired mounting location. Perform the following steps:
• Guide the three guide pins on the communication assembly through the holes in the module. The holes in which the guide pins must be inserted depend on the mounting location.
5 Mounting
• Carefully push the module down on the upper edge and on the connection sockets until it audibly snaps into both side locking tabs of the communication assembly. The connector strip on the back of the module is automatically pushed into the socket terminal strip of the communication assembly.
5. Screw tight the fastening screw with a Torx screwdriver (TX25) on the module (torque: 1.5Nm (13 in-lb)). This additionally fixes the module in place and grounds it in the inverter enclosure.
Installation Manual MD485-US-40-IA-en-11 13
Page 14

6 Connection

SMA Solar Technology AG
6 Connection

6.1 Preparing the Connection Cable

Depending on whether the module is located at the end or in the middle of the communication bus, prepare one or two connection cables as described in the following.
Requirements:
☐ The cable requirements must be complied with (see Installation Instructions "RS485 Cabling
Plan" at www.SMA-Solar.com).
☐ Diameter of the cable when using the cable support sleeve with one hole: at maximum 17 mm
(0.67in)
☐ Diameter of the cable when using the cable support sleeve with two holes: at maximum 6.5
mm (0.26in)
Procedure:
1. Strip 40mm (1.57in) of cable sheath from the end of the connection cable to which the terminal block is to be attached. Make sure that no pieces of cable are dropped into the inverter.
2. Trim the cable shield to a length of 15mm (0.59in) and fold it over the cable sheath.
3. Wrap the cable shield with copper foil.
4. Strip the insulation on the three insulated conductors each by 6mm (0.24in). The two insulated conductors used for communication must be a twisted pair.
5. Trim unneeded insulated conductors of the connection cable flush with the cable sheath.
Installation ManualMD485-US-40-IA-en-1114
Page 15
SMA Solar Technology AG
2 3
5 7
6 Connection

6.2 Inserting the Cables

Additionally required material (not included in the scope of delivery):
☐ Connection cable (see Section6.1, page14)
Procedure:
1. Make sure that the inverter has been disconnected and is secured against reconnection (see the inverter manual).
2. Remove the swivel nut from the cable gland for the communication cable.
3. Thread the swivel nut over the cable.
4. Press the two-hole cable support sleeve out of the cable gland.
5. Remove the sealing plug from one of the enclosure openings of the two-hole cable support sleeve and insert the cable into the enclosure opening.
6. Press the two-hole cable support sleeve with the cable into the cable gland and guide the cable to the communication assembly in the DC Connection Unit. Ensure that any unused enclosure openings of the two-hole cable support sleeve are sealed with sealing plugs.
7. Tighten the swivel nut on the cable gland hand-tight. This will secure the cable.

6.3 Connecting the Cable

Assignment of the terminal block:
Terminal block Clamping
position
2 Data+ (D+)
3 Not assigned
5 Ground (GND)
7 Data- (D-)
Assignment
Procedure:
1. Plug a terminal block each into the jack on the module.
2. If one connection cable is to be connected, attach the terminator:
Installation Manual MD485-US-40-IA-en-11 15
Page 16
6 Connection
SMA Solar Technology AG
• Push the levers of the terminals 2 and 7 of a terminal block upwards.
• Bend the ends of the terminator downwards and plug the terminator into the open terminals.
• Close the levers of the terminals.
3. Push the levers of the terminals 2, 5 and 7 of a terminal block upwards.
4. Connect the insulated conductors to the terminals 2, 5 and 7 and note the insulated conductor colors (see Installation Instructions "RS485 Cabling Plan" at www.SMA-Solar.com).
5. Close the levers of the terminals.
6. Press each connection cable with the cable shield into the shield clamp on the module.
7. If no further connections are required on the module, close the inverter and commission it (see the inverter manual).
Installation ManualMD485-US-40-IA-en-1116
Page 17
SMA Solar Technology AG

7 Decommissioning

7 Decommissioning

7.1 Removing the Module

NOTICE
Damage to the inverter due to moisture ingress during electrical installation
• Never open the inverter when it is raining or snowing, or the humidity is over 95%.
• For attaching the conduits to the enclosure, only use UL-listed rain-tight conduit fittings for wet locations.
• Seal all unused openings tightly.
Procedure:
1.
Danger to life due to high voltages of the PV array
When exposed to sunlight, the PV array generates dangerous DC voltage, which is present in the DC conductors and the live components of the inverter. Touching the DC conductors or the live components can lead to lethal electric shocks.
• Prior to performing any work on the inverter, always disconnect the inverter from voltage sources on the AC and DC sides as described in the inverter manual. When doing so, note that even if the DC load-break is switched off, there will be dangerous direct voltage present in the DC conductors of the inverter.
2. Remove the enclosure lid of the DC Connection Unit. Unscrew all screws with a Torx screwdriver (TX25) and remove the enclosure lid carefully forward.
3. Set the screws and the enclosure lid aside and store safely.
4. Remove all connecting terminal plates from the used connection sockets of the module.
5. Unscrew the fastening screw on the module using a Torx screwdriver (TX25).
6. Remove the module:
• Press the right or left locking tab of the communication assembly slightly outwards and pull the module slightly forwards holding the lower end until the module is released from the interlock of the locking tab.
• Grab the module by the upper and lower edge with one hand.
• Slightly press the second locking tab outwards using the other hand and pull the module slightly forwards on the lower end until the module is released from the interlock of the locking tab.
• Remove the module from its slot by pulling it forwards.
7. Lead the connection cable out of the two-hole cable support sleeve.
8. Lead the connection cable out of the swivel nut.
9. Close the inverter and, if necessary, recommission it (see inverter manual).
DANGER
Installation Manual MD485-US-40-IA-en-11 17
Page 18
7 Decommissioning
SMA Solar Technology AG

7.2 Packing the Product for Shipment

• Pack the product for shipping. Use the original packaging or packaging that is suitable for the weight and size of the product.

7.3 Disposing of the Product

• Dispose of the product in accordance with the locally applicable disposal regulations for electronic waste.
Installation ManualMD485-US-40-IA-en-1118
Page 19
SMA Solar Technology AG

8 Technical Data

8 Technical Data
General Data
Mounting location In the inverter
Voltage supply Via the inverter
Mechanical Data
Width x height x depth 60mmx105mmx33mm (2.4inx
4.1inx1.3in)
Ambient Conditions for Storage/Transport
Ambient temperature -40°C to +70°C (-40°F to +158°F)
Relative humidity, non-condensing 10% to 100%
Maximum height above mean sea level 3000m (9842ft)
Communication
Interface RS485
Maximum cable length 1200m (3937ft)
Terminals
Type of plug 4-pole spring-cage terminal
Number of RS485 connections 2
Installation Manual MD485-US-40-IA-en-11 19
Page 20

9 Compliance Information

SMA Solar Technology AG
9 Compliance Information
FCC Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. this device may not cause harmful interference, and
2. this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications made to this equipment not expressly approved by SMA Solar Technology AG may void the FCC authorization to operate this equipment.
Installation ManualMD485-US-40-IA-en-1120
Page 21
SMA Solar Technology AG

10 Contact

If you have technical problems with our products, please contact the SMAServiceLine. The following data is required in order to provide you with the necessary assistance:
• Inverters:
– Serial number – Firmware version – Special country-specific settings (if available)
• Detailed description of the problem
• Module:
– Serial number – Hardware version
United States SMA Solar Technology
America LLC Rocklin, CA
Canada SMA Solar Technology
Canada Inc. Mississauga
Toll free for USA and US Territories +1877-MY-SMATech (+1877-697-6283)
International: +1916625-0870
Toll free for Canada / Sans frais pour le Canada : +1877-MY-SMATech (+1877-697-6283)
10 Contact
Installation Manual MD485-US-40-IA-en-11 21