SilentKnight HFS-MM User Manual

(ELR-47k)
INSTALLATION AND MAINTENANCE INSTRUCTIONS
REVISED
by the Graphic Development Department
Please review all content carefully.
11:45 am, Aug 07, 2009
HFS-MM Miniature Monitor Module
SPECIFICATIONS
Nominal Operating Voltage: 15-32 VDC Average Operating Current: 375µA maximum (group poll); 350 µA (direct poll); 600 µA Max. (Communicating, IDC Shorted) EOL resistance: 47K Ohms Maximum SLC Wiring Resistance: 40 Ohms Maximum IDC Wiring Resistance: 1,500 Ohms Maximum IDC Voltage: 11 Volts Maximum IDC Current: 450µA Temperature Range: 32°F to 120°F (0°C to 49°C) Humidity: 10% to 93% Non-condensing Dimensions: 1.3˝ H x 2.75˝ W x 0.5˝ D Wire Length: 6˝ minimum
BEFORE INSTALLING
This information is included as a quick reference installation guide. Refer to the control panel installation manual for detailed system information. If the modules will be installed in an existing operational system, inform the opera­tor and local authority that the system will be temporarily out of service. Dis­connect power to the control panel before installing the modules.
NOTICE: This manual should be left with the owner/user of this equipment.
GENERAL DESCRIPTION
The HFS-MM minitature monitor module can be installed in a single gang junction box directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting (see Figure 1). The HFS-MM is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat­ing device circuit for normally open contact fire alarm and security devices.
COMPATIBILITY REQUIREMENTS
To ensure proper operation, this module shall be connected to listed-compat­ible control panels only.
FIGURE 1:
MOUNTING AND WIRING
NOTE: This module is intended to be wired and mounted without rigid con­nections inside a standard electrical box. All wiring must conform to appli­cable local codes, ordinances and regulations.
1. Connect the red (+) and black (–) wires to the positive and negative loop power leads of the signaling line circuit (SLC).
2. Connect the violet (+) and yellow (–) wires to a two-wire, normally open initiating loop.
4. Reference the control panel device address map to determine appropriate addressing.
5. Set the address on the module per job drawings.
6. Install the module in the desired mounting location.
FIGURE 2. TYPICAL 2-WIRE STYLE B INITIATING DEVICE CIRCUIT CONFIGURATION:
UL LISTED
COMPATIBLE
CONTROL
PANEL
(+)
SIGNAL LINE CIRCUIT (SLC)
(–)
Northford, CT 06472-1653
I56-3487-000
12 Clintonville Road
Phone: 203.484.7161
TO NEXT DEVICE
0
ALL WIRING
SHOWN IS
SUPERVISED AND
POWER LIMITED
15
14 13 12
11
10
9
TENS
YELLOW
VIOLET
0
1
2 3 4 5
6
7
8
(–)
1
2
3 4
5
9
6
8
7
ONES
(+)
(+)
(–)
BLACK
RED
47k EOL INCLUDED
C0614-02
C1063-00
HW-460-016 1 I56-3487-000 ©2009 Honeywell International, Inc.
Loading...