Siemens Mammomat 3000 Planning Guide

MAMMOMAT 300/1000/3000
Planning Guide
SP
© Siemens AG 1999
The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model _or_ design,_are_ reserved.
English Print No.: SPB7-120.021.01.01.02 Doc. Gen. Date: 03.99
Replaces: RXB7-120.021.01.05.02
0 - 2 Revision
Chapter Page Revision
all all 01 all all 01 all all 01 all all 01 all all 01
MAMMOMAT 300/1000/3000 SPB7-120.021.01 Page 2 of 4 Siemens AG Rev. 01 03.99 TD SD 21 Medical En gineering
Contents 0 - 3
Page
1 _______General Notes _________________________________________________1 - 1
General notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 1
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 1
System configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 4
2 _______Room Planning ________________________________________________2 - 1
Dimensions for the MAMMOMAT 300/ 1000/ 3000 . . . . . . . . . . . . . . . . . . .2 - 1
Attaching the remote control panel to the wall or on a table . . . . . . . . . . . . . . 2 - 3
Measurements of the column . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 4
Measurements for the generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 5
Generator with integrated radiat ion protection shield and operating console . . . . 2 - 5
Measurements for the generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 6
Generator for external operating console . . . . . . . . . . . . . . . . . . . . . . 2 - 6
Measurements for the radiation protection shield (optional) . . . . . . . . . . . . . . 2 - 7
Range of the swivel arm system . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 8
Stereotactic biopsy attachment (option for MAMMOMAT 3000) . . . . . . . . . . . . 2 - 9
3 _______Preparation for Installation_______________________________________3 - 1
Recommendation for On-site Electro Installation . . . . . . . . . . . . . . . . . . . . 3 - 1
Recommendation for On-site Electro Installation . . . . . . . . . . . . . . . . . . . . 3 - 2
4 _______Technical Data _________________________________________________4 - 1
Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 1
Environmental conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 1
Weight and heat dissipati o n. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 2
Packing and transport routes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 2
Surface colors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 2
Additional data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 - 2
5 _______Project Management ____________________________________________5 - 1
Responsibility of the project manager towards the service contractor . . . . . . . . . 5 - 1
Preparation for installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 1
Protocols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 2
Siemens AG SPB7-120.021.01 Page 3 of 4 MAMMOMAT 300/1000/3000 Medical Engineering Rev. 01 03.99 TD SD 21
0 - 4 Contents
This page intentionally left blank.
MAMMOMAT 300/1000/3000 SPB7-120.021.01 Page 4 of 4 Siemens AG Rev. 01 03.99 TD SD 21 Medical En gineering

General Notes 1

1 - 1

General notes 1

- With distributi on of this revision level, all precedi ng planning guides, Speed - Infos (PG’s ) and drafts lose their validity.
- All layouts i ssued by the Planning Departments must bear a note ref erring to the installati on and delivery conditions of Siemens Medical Engineering Group. The installation and del ivery conditions must be submitted with the layouts.
- Unless otherwise spe cified, all dimensions are indi cated in "mm".
- The symbol indicates a change (see revision status).
- Orientation poi nts Points specific to system components to whi ch reference is made when positioning syst em components to each other or in the room. The isocenter of a radiographic syste m is always illustrated as the orien tation point.
- Fixpoints Clearly marked points on syst em components, installation ceil ing, walls or floor on which cable outlets are located. Illustration in the dra wings: circle with letter /number-combination. The cable lengths establish the maximum fixpoi nt distances and thus the maximum distances between the individual system components.
- Room height The room height is the distance measured f rom the top surface of the floor to the bot tom surface of the ceiling structural element s (Unistrut rails) (bottom surfac e of drop ceiling).

Safety 1

- The provisions of t he relevant fire protection reg ulations must be observed for the premi ses.
- The system has been developed acc ording to EN 60601 - 1.
- Minimum dimensions (e. g. room heights, safety distances) i ndicated in the planning guides are marked "min."
- Basic resistanc e to electromagnetic sources of inter ference. Result of lightning discharges. The protection targets of the diff erent lightning protection ar eas up to the unit connection are also specified in the IEC 1024, DIN 48810, VDE 0675 and in th e DEMVT recommendations.
Hotline Tel. (+49) (0) 9191/18 - 8080
Siemens AG SPB7-120.021.01 Page 1 of 4 MAMMOMAT 300/1000/3000 Medical Engineering Rev. 01 03.99 TD SD 21
1 - 2 General Notes
This Planning Guide is valid for:
MAMMOMAT 300 beginning with serial number 04 001 ...
MAMMOMAT 3000 beginning with serial number 03001 .. .
- Stereotactic biopsy attachment beginning with serial number 03001 .. .
MAMMOMAT 3000 beginning with serial number 05001 .. .
The MAMMOMAT 3000 beginning with serial number 05001 is available in 8 versions as the customer can make 3 choises when ordering the MAMMOMAT.
Common parts
Stand base module
Generator base module
X-ray tube P40 Mo/W-100G
1 A
2 A
3 A
W and Mo focus
Collimator with 3 filters
(30 µm Mo, 25 µm Rh and
50 µm Rh)
"Flying wing"
2 support plates with AEC
Generator mounted control
panel and radiation
protection
Selection 1
Selection 2
Selection 3
Mo focus, W focus inhibited
Collimator with 2 filters
(30 µm Mo and 25 µm Rh)
One table
1 support plate with AEC
Remote control panel
1 B
2 B
3 B
Options Free-standing radiation shield with lead equivalence of 0,3 mm Pb/110 kV, Free-standing radiation shield with lead equivalence of 0,1 mm Pb/110 kV,
Bus Installation Kit, Printer Interface, Stereo-tactic biobsy attachment, Opdima
MAMMOMAT 300/1000/3000 SPB7-120.021.01 Page 2 of 4 Siemens AG Rev. 01 03.99 TD SD 21 Medical En gineering
General Notes 1 - 3
This Planning Guide is valid for:
MAMMOMAT 3000 beginning with serial number 06501 ...
In addition to the 8 versions of the MAMMOMAT 3000 beginning with Serial number 05001, there are 4 versions beginning with Serial number 06501 of the MAMMOMAT 1000 available. The customer can make 2 more choises when ordering the MAMMOMAT.
Common parts
Stand base module
Generator base module
X-ray tube P40 Mo/W-100G
Mo focus,
4 A 4 BSelection 4
5 A 5 BSelection 5
W focus inhibited
Collimator with 1 filter
(30 µm Mo)
One table
1 support plate with AEC
Generator mounted control
panel and radiation
protection
Mo focus, W focus inhibited
Collimator with 2 filters
(30 µm Mo and 25 µm Rh)
Remote control panel
Options Free-standing radiation shield with lead equivalence of 0,3 mm Pb/110 kV, Free-standing radiation shield with lead equivalence of 0,1 mm Pb/110 kV,
Bus Installation Kit, Printer Interface, Opdima spot mode
Siemens AG SPB7-120.021.01 Page 3 of 4 MAMMOMAT 300/1000/3000 Medical Engineering Rev. 01 03.99 TD SD 21
1 - 4 General Notes

System configuration 1

(schematic)
figure shows MAMMOMAT 3000
MAMMOMAT 300/1000/3000 SPB7-120.021.01 Page 4 of 4 Siemens AG Rev. 01 03.99 TD SD 21 Medical En gineering