Siemens AC5200 Quick Start Manual

Page 1
Siemens AB
Access Control
AC5200
Quick Start Manual
Security Products
Page 2
Liefermöglichkeiten und technische Änderungen vorbehalten. Data and design subject to change without notice. / Supply subject to availability.
© 2014 Copyright by Siemens AB
Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor. Der Empfänger erkennt diese Rechte an und wird dieses Dokument nicht ohne unsere vorgängige schriftliche Ermächtigung ganz oder teilweise Dritten zugänglich machen oder außerhalb des Zweckes verwenden, zu dem es ihm übergeben worden ist.
We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our prior express written authorization, nor to use it for any purpose other than for which it was delivered to him.
Page 3
Siemens AB
Security Products
10.2013
Contents
1 Introduction ............................................................................................. 5
1.1 Power Supply ............................................................................................ 5
1.2 Installation Overview ................................................................................. 5
1.3 AC5200 Exterior ........................................................................................ 6
1.4 AC5200 Interior ......................................................................................... 7
1.5 AC5200 Mechanical .................................................................................. 8
2 Hardware Connection ............................................................................. 9
2.1 Basic Connection ...................................................................................... 9
2.2 Explanation of connectors ....................................................................... 10
2.3 Mounting the AC5200 ............................................................................. 11
2.4 Battery Installation................................................................................... 11
3 AC5200 Configuration .......................................................................... 12
3.1 Upgrading an Entro SR34i or SR35i ....................................................... 12
3.2 Configuring Network Settings ................................................................. 13
3.3 Firmware Download ................................................................................ 14
3.4 License Download ................................................................................... 14
4 Menu Navigation ................................................................................... 15
5 Keyword index ....................................................................................... 18
3
Page 4
Siemens AB
Security Products
10.2013
4
Page 5
Siemens AB
Security Products
10.2013

1 Introduction

The AC5200 (ACC-Lite) is a smaller alternative to the ACC (Advanced Central Controller) used in SiPass integrated. The AC5200 is based on the Entro SR34i/SR35i controller and exists in two variations:
AC5200: 8 Door controller with preloaded ACC Firmware. ACC-X – An Entro Controller upgraded with ACC Firmware. The X represents
the number of doors supported.
The AC5200 can be used with either ACC or Entro devices. However ACC-X con­trollers can only be used with Entro devices, and are for migration sites.
This Quick Start Manual outlines how to install and configure an AC5200 controller to work with SiPass integrated.
Introduction

1.1 Power Supply

Ensure that the power supply is stable and within the rated voltage of the unit. Use an uninterrupted power supply (UPS) to ensure a continuous function of the unit in the event of power dips on the mains supply.

1.2 Installation Overview

The following is a list of items required to complete this installation:
AC5200 or Entro SR34i/SR35i Controller 12-24V power source Ethernet cable ACC FLN or Entro Devices + wiring
Optional items:
Modem + RS232 cable
The installation should proceed in this order:
1. Connect power to the AC5200.
2. Connect the FLN bus.
3. Connect the Ethernet.
4. Configure the network settings.
5. Create the AC5200 in SiPass integrated.
5
Page 6
Introduction
Siemens AB
Security Products
10.2013

1.3 AC5200 Exterior

Fig. 1 AC5200 Exterior
AC5200 Exterior Items
Item Description
A LCD Panel. By default this displays basic information about the
B Keypad cover. When the AC5200 is unlocked and the doors
C Keylock. To open the AC5200 cover the correct key must be
D Cover Door. The AC5200 provides two cover doors that can be
controller but it can also be used to set system configuration.
opened, this cover slides downward exposing a numeric keypad that can be used to set basic options for the AC5200.
used to unlock and provide mechanical access.
used to gain access to the connectors that allow devices (eg: DC12 / D22 etc.) to be connected to an AC5200.
6
Page 7
Siemens AB
Security Products
10.2013

1.4 AC5200 Interior

Introduction
Fig. 2 AC5200 Interior Diagram
Item Description
A Lock for use with supplied key. The middle of the front lid must be
pressed downwards before the left and rid lid can be opened.
B1, B2 Corner details that can be knocked out for hiding cable entry.
C Wall mounting screw holes. Remember to leave approximately
70mm space around the controller.
D Cable management mounting.
E RS485 bus connection for devices
F Not in use
G Not in use
H Socket for compact flash card (only supported for Entro upgrade)
I RS232 Modem / Diagnostics port
J 1st RJ45 Ethernet connection
K 2nd RJ45 Ethernet connection
L Battery socket, type CR2032.
M Display for showing and entering information
N Tamper switch
7
Page 8
Introduction
Siemens AB
Security Products
10.2013

1.5 AC5200 Mechanical

8
Fig. 3 AC5200 Mechanical Layout
Page 9
Siemens AB
Security Products
10.2013

2 Hardware Connection

This chapter explains how to connect up the power, communications and other things to the AC5200 hardware.

2.1 Basic Connection

The following section outlines the basic tasks required to get the AC5200 up and running.
Power Connection
The AC5200 requires a 12-24V power supply. Connect the power at terminals 1 and 2 of the AC5200.
Communication with devices
The AC5200 has one FLN to communicate with devices, which operates over RS485. The following table explains what devices are available:
Hardware Connection
Controller Bus Protocol Devices Supported
AC5200 ACC FLN SRI (Single Reader Interface)
DRI (Dual Reader Interface)
ERI (Eight Reader Interface)
8IO (Eight Input / Output Module)
IPM (32 Input Module)
OPM (16 Output /16 Input Module)
Entro DC12 (Dual Reader Interface)
DC22 (Dual Reader Interface)
DC800 (Dual Reader Interface)
IOR6 (4 Input / 6 Output Module)
ACC-X Entro DC12 (Dual Reader Interface)
DC22 (Dual Reader Interface)
DC800 (Dual Reader Interface)
IOR6 (4 Input / 6 Output Module)
Connect your bus to COM A (terminal 4) and COM B (terminal 3). Connect COM A to COM A and COM B to COM B for Entro devices Connect + to COM A and – to COM B for ACC FLN devices
When using DRI (ADD5100) / ERI (ADE5300) / SRI (ADS5200) a 120 Ohm termi­nation only at door control unit side is required. For DC12 / DC22 / IOR6 120 Ohm termination on both ends, door unit and AC5200 controller side, is required.
9
Page 10
Hardware Connection
Siemens AB
Security Products
10.2013
Communication with SiPass integrated
The AC5200 communicates with SiPass integrated via TCP/IP. Connect an Ether­net cable to either of the available RJ45 Ethernet connections.
Peer to Peer communication between controllers is also done via TCP/IP.

2.2 Explanation of connectors

The following table explains of each of the available connectors on the AC5200.
Terminal Number Connector Label Description
1 12-24V + Positive connector for power source
2 Negative connector for power source
3 COM B RS485 bus connection for FLN/Entro
4 COM A RS485 bus connection for FLN/Entro
5 FRAME Signal screen for RS485 bus connec-
6 COM B Not in use
7 COM A Not in use
8 FRAME Not in use
devices
devices
tion.
10
Page 11
Siemens AB
Security Products
10.2013

2.3 Mounting the AC5200

The following instruction explains how to mount an AC5200.
To mount an AC5200:
1. Remove the AC5200 from its carton and discard the packaging material.
2. Place the AC5200 against the surface to which it is to be affixed and mark the
location of the mounting holes.
3. Select the appropriate drill bit according to the mounting surface / hole size and drill the holes in the locations marked (if required).
4. Fasten the AC5200 to the surface using the correct type of screws or stand­offs for the surface in the 4 locations provided.
5. Download the firmware instruction set (as described in the section titled “Firmware Download”).
6. Connect the cabling to the ACC (as described in the section titled “Wiring”).
7. Apply power to the ACC and test its operation. This step will require pro-
gramming of the host software.
Hardware Connection

2.4 Battery Installation

A battery is already installed and shipped with the AC5200.
To activate the AC5200 battery:
1. Open the AC5200 case
2. Remove the orange isolating plastic band to activate the battery poles.
11
Page 12
AC5200 Configuration
Siemens AB
Security Products
10.2013

3 AC5200 Configuration

This chapter outlines the configuration steps required to connect an AC5200 with SiPass integrated.

3.1 Upgrading an Entro SR34i or SR35i

This section only applies if you are upgrading Entro controllers in the field to ACC­X units.
Requirements:
SAN-Disk Compact Flash card. ACC-X Firmware upgrade file.
To upgrade an Entro Controller to an ACC-X:
1. Determine the version of Entro firmware currently running. This can be found
on the Status screen of the Entro Software running on the PC
It can also be found on the LCD menu interface of the SR34i/SR35i.
2. Select the appropriate upgrade file as specified in the table below. This file can be found on the CD in the Firmware\ACC\ACC-X folder.
3. Copy this file to the Compact Flash card.
Entro Firmware Version Renamed ACC-X upgrade file
Earlier versions patch.dat
5.2 patch_SR34i.dat
5.25 SR_firmware.hex (upgrade path to 5.3)
5.3 SR_firmware.hex (allows > 1Meg files)
4. Determine the IP address of the SiPass integrated Server PC, and record it.
5. Use the LCD menu on the SR34i/SR35i to determine the current IP address,
gateway, subnet mask and door count, and make a note of these values (write it down on paper or otherwise record the values as they will be needed later).
6. Carefully Insert the Compact Flash card into the SR34i/SR35i controller unit.
7. Answer yes when the LCD menu asks “Upgrade to new firmware?”.
8. Wait for the LCD menu to confirm that it has completed the upgrade (this usu-
ally takes several minutes) and then remove the Compact Flash card.
9. Wait a moment for the ACC-X firmware to get running.
10. Make a note of the serial number displayed.
11. Use the LCD menu to re-enter the IP address, gateway, subnet mask and
Server IP address.
12. Repeat steps 4-11 for each controller
12
Page 13
Siemens AB
Security Products
10.2013
13. For each SR34i/SR35i upgraded, in the SiPass integrated bring up the Com­ponent dialog and from the “ACC Controllers” item select “New Unit”.
14. Select the Controller type as ACC-4, 8, 16, or 32, depending on the door count.
15. Enter in the serial number saved from ACC-X startup screen and save it.
The ACC-X should connect to SiPass integrated shortly.
Make a note of the serial number and door count, and contact Logistics to pur­chase an ACC-X Upgrade licence to make the upgrade permanent

3.2 Configuring Network Settings

Once your AC5200 is powered up and connected to the network, you will need to configure the network settings and also note down the serial number.
To configure an AC5200:
1. Open the AC5200 case if it is not already open
2. Press 2 to modify Network Settings
3. Press 2 to Change IP Settings
4. Press 1 to set the IP Address
Enter the new IP address with the keypad For numbers that are less than three digits add 0s in front, for example 001 or
016
Press any key except 1 to continue
5. Press 2 to set the Subnet Mask
Enter the subnet mask with the keypad Press any key except 1 to continue
6. Press 3 to set the Gateway Address
Enter the gateway address with the keypad. Press any key except 1 to continue
7. Press 4 to set the Host Address. This is the IP address of your SiPass inte­grated server PC
Enter the host address with the keypad.
8. Press 5 to set the Port Address. This is the port the AC5200 uses to com­municate with SiPass integrated. By default it is 4343
Enter the port address with the keypad.
9. Press 1 to Apply Changes and Restart your AC5200
AC5200 Configuration
The AC5200 will restart with the entered network settings. You should see an Audit Trail message in SiPass integrated indicating that the AC5200 is trying to connect.
13
Page 14
AC5200 Configuration
Siemens AB
Security Products
10.2013

3.3 Firmware Download

Firmware downloads are done from the SiPass integrated software. This process is the same as downloading firmware for an ACC.
Before you begin:
The AC5200 must be created in the SiPass integrated database and be com-
municating
To download firmware to the AC5200:
1. Select System > Initialize.
2. Double click your AC5200 from the list of available units.
3. Click Image Download.
4. Click Browse to select the firmware image to download.
5. Click Download. The selected firmware will be downloaded and the AC5200
will reset once it has been upgraded.
6. Click Close to close the Initialize System dialog.

3.4 License Download

License downloads for the ACC-X are done from the SiPass integrated software.
Before you begin:
The ACC-X must be created in the SiPass integrated database and be com-
municating
To download a license to the AC5200:
1. Select System > Initialize.
2. Double click your ACC-X from the list of available units.
3. Click License Download.
4. Click Browse to select the firmware image to download.
5. Click Download. The selected license will be downloaded to the AC5200.
6. Click Close to close the Initialize System dialog.
14
Page 15
Siemens AB
Security Products
10.2013

4 Menu Navigation

This chapter explains the various menu navigation options.
Menu Navigation
Fig. 4 AC5200 Keypad
Item Description
A Display for Navigation and Messages
B Address Setting
C Escape Key (goes back to the previous menu)
D Backspace while entering (letters and digits)
E Confirmation button (some menus)
F Enter Key
G No function
H Number keys 0-9
I No function
15
Page 16
Page 17
Menu Navigation
Siemens AB
Security Products
10.2013
Menu Navigation Options
Menu Structure Keys Result
1) System Information 1) General Information 1-1 Returns the serial number, model and hard-
2) Supply Voltage 1-2 Returns the power supply and battery voltage.
3) Software Versions 1-3 Returns the Application version information
2) Network Settings 1) View IP Settings 2-1 Returns the IP settings
2) Change IP Settings 1) IP Address Enter IP Address 2-2-1 IP address is set
2) Subnet Mask Enter Subnet Mask 2-2-2 Subnet Mask is set
3) Gateway Address Enter Gateway Address 2-2-3 Gateway Address is set
4) Host Address Enter Host Address 2-2-4 Host Address is set
5) Port Address Enter Port Address 2-2-5 Port Address is set
3) Telnet settings 1) To Disable / To Enable 2-3-1 Toggles telnet access Enabled Disabled
4) Reset to apply changes 1) Reset and apply changes 2-4-1 Resets the AC5200 and applies all network
3) Compact Flash 1) Entro Firmware / Upgrade AC5200 Firmware
3-1 Firmware upgrade will commence and a status
ware type.
Note the battery voltage des not automatically update
changes.
will be displayed on the bottom line.
17
Page 18
Keyword index
Siemens AB
Security Products
10.2013

5 Keyword index

A
AC5200, 5 ACC FLN, 9 ACC-X, 5
C
Change IP Settings, 17 COM A, 10 COM B, 10 Communication with devices, 9 Communication with SiPass integrated, 10 Compact Flash, 17 Cover Door, 6
E
Entro, 9
F
FRAME, 10
G
Gateway Address, 13, 17 General Information, 17
K
Keylock, 6 Keypad cover, 6
L
LCD Panel, 6
N
Network Settings, 13, 17
P
Port Address, 13, 17 Power Connection, 9
R
Reset and apply changes, 17 Reset to apply changes, 17
S
Software Versions, 17 Subnet Mask, 13, 17 Supply Voltage, 17 System Information, 17
H
Host Address, 13, 17
I
Image Download, 14 IP Address, 13, 17 IP Settings, 13
T
Telnet settings, 17
V,W
View IP Settings, 17
18
Page 19
Page 20
www.siemens.com/securityproducts
Document no.
A6V10208242
Edition
10.2013
Issued by Siemens AB
Infrastructure & Cities Security Products International Headquarters Englundavägen 7 SE-171 24 Solna Tel. +46 8 629 0300
© 2014 Copyright by Siemens AB
Data and design subject to change without notice.
Supply subject to availability.
Loading...