SELF SLF SLT20-12VFGS Datasheet

Characteristics:
www.self-ecg.com
p
e
v
ge
o
a
usupply
Constant Voltage LED Power Supply
Standards:
EN61347-1
EN61347-2-13
EN61547
EN55015
EN61000-3-2
EN61000-3-3
EN62384
EN62493
Product description
This ty
This type of power supply is an exclusively designed
stabiliz
stabilized power supply for LED lamp. With constant
olta
voltage (CV) technology, it is suitable for constant voltage
amps
lamps (12/24V DC) connected in parallels. As an advan-
tage
tage of constant voltage (CV) technology, a switch can
e inst
be installed between secondary side and lamps.
The b
The built-in protection circuit will shut down the power
supply in case of such faults as: open circuit, short circuit,
over load or over temperature. The power supply will
restart automatically after fault correction.
Characteristics:
Independent power supply for constant voltage LED
lamp
Special design screw terminal for field connection
•
Class II protection against electric shock from direct
and indirect contact
SELV output
Open circuitshort circuitover load and over
temperature protection
Auto restart after fault conditions removal
Quiet design,working noise is less than 20dB
No load power consumption0.3W
Efficiency 83%AC230V,full load
Last update: 23 Mar, 2017 Page: 1 of 5
Input
Other
Note
Ambient and Life
Protection
Output
Model
Specifications
Specifications
turn on time(S)
output power(W)
output votage(V)
output voltage tolerance
ripple voltage(mV)
working current range(A)
dimming interface
dimming range
rated supply voltage(Vac)
voltage range(Vac)
line frequency(Hz)
input current(mA)
eciency
average eciency
no load power consumption(W)
power factor
inrush current(Ipk)
over voltage protection
short circuit protection
over temperature protection
automatic restart
over load protection
surge capacity
Ta() )
Tc max.() )
Storage Temperature() )
ambient humidity range
nominal life-time(hrs)
weight(g)
dimensions (L×W×H)(mm)
casing material
housing colour
type of protection
protection class
SLT20-12VFGs
SLT20-24VFGs
www.self-ecg.com
In
turn on time(S)
output power(W)
output votage(V)
output voltage tolerance
ripple voltage(mV)
working current range(A)
dimming interface
dimming range
rated supply voltage(Vac)
voltage range(Vac)
line frequency(Hz)
input current(mA)
eciency
average eciency
no load power consumption(W)
power factor
inrush current(Ipk)
over voltage protection
short circuit protection
over temperature protection
automatic restart
over load protection
surge capacity
Ta(
Tc max.(
Storage Temperature(
ambient humidity range
nominal life-time(hrs)
weight(g)
dimensions (L×W×H)(mm)
casing material
housing colour
type of protection
protection class
2
2
1
3
SLT20-12VFGs
0.5
20
12
+/-5%
400(Vp-p)
0-1.67
220-240
198-264
50/60
200
84.1%
82.4%
0.3
0.50
30A/50us
YES
YES
YES
YES
YES
L-N: 500V
-20…50
75
90
No
n/a
-30...80
5%...85%Not condensing
35'000@Tc=75
166×40×14
Plastic
White+Blue
IP20
ClassII
SLT20-24VFGs
0.5
20
24
+/-5%
500(Vp-p)
0-0.84
220-240
198-264
50/60
200
84.3%
81.1%
0.3
0.50
30A/50us
YES
YES
YES
YES
YES
L-N: 500V
-20…50
75
90
Note
Page: 2 of 5
1. Tolerance:includes set up tolerance, line regulation and load regulation.
2. Tested at full load,230Vac.Refer to"Power Factor" and "EFFICIENT"curve graphs.
3. Calculate the model’s average efficiency for each test voltage by testing at 100%, 75%, 50%, and 25% of rated current and then computing the simple arithmetic erage of these four values.
4. All parameters NOT specially mentioned are measured at nominal voltage input, rated load and 25 of ambient temperature.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
Wiring diagram:
Dimensions(mm):
Dimensions(mm):
14
33
40
www.self-ecg.com
132 166
Wiring diagram:
220-240V
AC
50/60Hz
N
L
PRI
LED POWER SUPPLY
wire preparation
0.5-0.75
SEC
7-8mm
Page: 3 of 5
Electrical curves:
www.self-ecg.com
PF
LOAD
PF vs LOAD(230Vac)
EFFICIENCY(%)
LOAD
EFFICIENCY vs LOAD(230Vac)
Electrical curves:
0.60
0.55
0.50
0.45
0.40
0.35
0.30
0.25
0.20 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
12
24
90
85
80
75
70
65
60
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
note For constant current power supply,"LOAD" means the percentage of the maximum rated output voltage. For constant voltage power supply,"LOAD" means the percentage of the maximum rated output current.
12
24
Page: 4 of 5
Sales & Technical Support:
Sales & Technical Support:
Se lf Electr onics Co. ,Ltd .
SE LF ELECTR ONICS GER MANY G MBH
Se lf Electr onics Co. ,Ltd .,Shenz hen Offic e
Self Electronics Co.,Ltd.
Add: No. 1345 Ju Xian Road, Ningbo Hi Tech Park, Ningbo,
China
Tel: 0086-574-28805765,28805658(For English Assistance)
0086-574-28805678 (For Chinese Assistance)
Fax: 0086-574-28805656
E-mail: sales@self-ecg.com
http://www.self-ecg.com
SELF ELECTRONICS GERMANY GMBH
Add:August-Horch-Str. 7,51149 Koeln
Tel: 0049 2203 18501-0
Fax: 0049 2203 18501-199
E-mail: saleseu@self-electronics.com
www.self-ecg.com
Self Electronics Co.,Ltd.,Shenzhen Office
Add: Room2007,Xinglang Xuan,Xinghe Mingju,Fuming
Road,Futian District,Shenzhen
Tel: 0086-755-83558850, 83558851
Fax: 0086-755-83558840
*Due to continuous improvements and innovations,specifications are subjected to change without notice.
Page: 5 of 5
Loading...