SELF SLT75-12VFC-UN Datasheet

Page 1
Characteristics:
www.self-ecg.com
Product description:
Constant Voltage LED Power Supply
SLT75-12VFC-UN SLT75-24VFC-UN
IP67
Product description
This LED power input voltage of 120-240VAC, the output constant voltage 12V or 24V, for load parallel voltage LED. This LED power supply shape slim and thin. LED power supply has open circuit, short circuit, overload or over temperature protection function, troubleshooting, the power will automatically restart.
pending
Standards:
EN61347-1 EN61347-2-13 EN61547 EN55015 EN61000-3-2 EN61000-3-3 EN62384 EN62493 UL8750 FCC15B
pending
Patent
Patent
pending
Characteristics:
• The standard requirements to meet IEV60335-2-89;
• Power section is divided into 30W,75W the output voltage of 12V and 24V;
• Surge level, according to L, N: 2000V, L, N-PE: 4000V
• Metal case for indoor or outdoor installation
• Suitable for class I luminaire
• Suitable for dry/damp/wet locations
• Class 2 power unit
• Efficiency:91.2% (AC230V ,full load )
• Life to meet the 5-year warranty requirements, failure rate to meet 0.1% / 1000h
Last update:18 Aug, 2017 Page: 1 of 5
Page 2
Input
Other
Note
Ambient and Life
Protection
Output
Model
Specifications
Specifications:
turn on time(S )
output power(W )
output votage( V)
output voltage tolerance
ripple voltage (mV)
working curren t range(A)
dimming interf ace
dimming range
rated supply v oltage(Vac)
volta ge range( Vac)
line frequency (Hz)
input current( mA)
effic iency
average effici ency
no load power consumption(W)
power factor
inrush current (Ipk)
over voltage p rotection
short circuit protection
over temperature protection
autom atic restart
over load prot ection
surge capacity
Ta(℃) )
Tc ma x.(℃) )
Stora ge Temperature(℃) )
ambient humidi ty range
nominal life-t ime(hrs)
guarantee(year s)
MTBF( hrs)
audible noise(dB)
weight(g)
dimensions (L× W×H)(mm)
casing materia l
housing colour
type of protection
prote ction cla ss
SLT75-24VFC-UN
SLT75-12VFC-UN
www.self-ecg.com
In
Note
SLT75-12VFC-UN
turn on time(S)
output power(W)
output votage(V)
output voltage tolerance
ripple voltage(mV)
working current range(A)
dimming interface
dimming range
rated supply voltage(Vac)
voltage range(Vac)
line frequency(Hz)
input current(mA)
efficiency
average efficiency
no load power consumption(W)
power factor
inrush current(Ipk)
over voltage protection
short circuit protection
over temperature protection
automatic restart
over load protection
surge capacity
Ta(
Tc max.(
Storage Temperature(
ambient humidity range
nominal life-time(hrs)
guarantee(years)
MTBF(hrs)
audible noise(dB)
weight(g)
dimensions (L×W×H)(mm)
casing material
housing colour
type of protection
protection class
1. Tolerance:includes set up tolerance, line regulation and load regulation.
2. Tested at full load,230Vac.Refer to"Power Factor" and "EFFICIENT"curve graphs.
3. Calculate the model’s average efficiency for each test voltage by testing at 100%, 75%, 50%, and 25% of rated current and then computing the simple arithmetic erage of these four values.
4. All parameters NOT specially mentioned are measured at nominal voltage input, rated load and 25 of ambient temperature.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again."
2
2
1
3
60@120Vac ,75@220-240Vac
600mA@120Vac,400mA@230Vac
< 0.5
12
+/-5%
400(Vp-p)
0-6.25
No
n/a
120-240Vac 108-264Vac
50/60
700mA@120Vac,400mA@230Vac
90.7%
86.4% <0.5
0.95
21.2A/129us YES
YES YES YES YES
L-N: 2KV L,N-PE: 4KV
-20…50 75
-30...80
5%...85%RH,Not condensing
50'000@Tc=75℃
5
100'0000
<25dBA
230
333x30x16.5
Aluminum
Silver
IP67
Class I
SLT75-24VFC-UN
< 0.5
75 24
+/-5%
600(Vp-p)
0-3.15
120-240Vac 108-264Vac
50/60
91.2%
86.6% <0.5
0.95
21.2A/129us
-20…50 75
Last update:18 Aug, 2017 Page: 2 of 5
Page 3
Wiring diagram:
Dimensions: mm
Dimensions: mm
www.self-ecg.com
3016.5
10
150
Wiring diagram:
150
333
Last update:18 Aug, 2017 Page: 3 of 5
Page 4
0.50
0.55
0.60
0.65
0.70
0.75
0.80
0.85
0.90
0.95
1.00
102030405060708090
100
PPF
PF vs load[120Vac]
12V 24V
60
65
70
75
80
85
90
95
100
10
20
30
40
50
60
70
80
90
100
Efficiency[%]
Efficiency vs load[230Vac]
12V 24V
Electrical curves:
Electrical curves:
0.50
0.55
0.60
0.65
0.70
0.75
0.80
0.85
0.90
0.95
1.00
102030405060708090
100
PF
PF vs load[230Vac]
12V 24V
LOAD
[%]
60
65
70
75
80
85
90
95
100
10
20
30
40
50
60
70
80
90
100
Efficiency[%]
Efficiency vs load[120Vac]
12V 24V
LOAD
[%]
LOAD
[%]
LOAD
[%]
[%]
www.self-ecg.com
[%]
P
[%]
note For constant current power supply,"LOAD" means the percentage of the maximum rated output voltage. For constant voltage power supply,"LOAD" means the percentage of the maximum rated output current.
Last update:18 Aug, 2017 Page: 4 of 5
[%]
Page 5
Sales & Technical Support:
Sales & Technical Support:
Self Electronics Co.,Ltd.
SELF ELECTRONICS GERMANY GMBH
Self Electronics Co.,Ltd.,Shenzhen Office
Self Electronics Co.,Ltd.
Add: No. 1345 Ju Xian Road, Ningbo Hi Tech Park, Ningbo, China Tel: 0086-574-28805765,28805658(For English Assistance) 0086-574-28805678 (For Chinese Assistance) Fax: 0086-574-28805656 E-mail: [email protected] http://www.self-ecg.com
SELF ELECTRONICS GERMANY GMBH
Add:August-Horch-Str. 7,51149 Koeln Tel: 0049 2203 18501-0 Fax: 0049 2203 18501-199 E-mail: [email protected]
www.self-ecg.com
Self Electronics Co.,Ltd.,Shenzhen Office
Add: Room2007,Xinglang Xuan,Xinghe Mingju,Fuming Road,Futian District,Shenzhen Tel: 0086-755-83558850, 83558851 Fax: 0086-755-83558840
*Due to continuous improvements and innovations,specifications are subjected to change without notice.
Last update:18 Aug, 2017 Page: 5 of 5
Loading...