XARS8D18p / XARS12D18p / XARS8L12p
Quick Start Guide
XARS8D18W / XARS8D18H / XARS12D18W / XARS12D18H XARS8L12W / XARS8L12H
Harmony eXLhoist
TM
www.schneider-electric.com/control
www.schneider-electric.com
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
p Disconnect all power from all equipment including connected devices, prior to removing any covers
or doors, or installing or removing any accessories, hardware, cables, or wires except under the
specific conditions specified in the appropriate hardware guide for this equipment.
p Always use a properly rated voltage sensing device to confirm the power is off where and when
indicated.
p Replace and secure all covers, accessories, hardware, cables, and wires and confirm that a proper
ground connection exists before applying power to the unit.
p Use only the specified voltage when operating this equipment and any associated products.
Failure to follow these instructions will result in death or serious injury.
It is recommended to charge the battery once a week, for a duration of at least 4 hours.
Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel.
No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material.
You can download our technical user guide file as well as the eXLhoist configuration software from our website at www.schneider-electric.com.
UNINTENDED EQUIPMENT OPERATION
p Use appropriate safety interlocks where personnel and/or equipment
hazards exist.
p Install and operate this equipment in an enclosure appropriately
rated for its intended environment.
p Do not disassemble, repair, or modify this equipment.
p Do not connect any wiring to unused connections, or to connections
designated as Not Connected (N.C.).
Failure to follow these instructions can result in death, serious
injury, or equipment damage.
WARNING
WARNING
UNINTENDED EQUIPMENT OPERATION
Power line must be wired and protected with fuse or thermal magnetic switch (ex: Schneider-Electric GV2) in compliance with local and national regulatory requirements for the
rated current and voltage of the particular equipment.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
WARNING
UNINTENDED EQUIPMENT OPERATION
Put the remote into STOP mode when not operating the unit to avoid accidental operations of motions push buttons.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
Note: You can decrease the "stand-by time out" value using the configuration software tool to reduce the time the remote is in run mode.
ZART8D ZARB18W
XARS8D18W
NHA45689 02
09 - 2016
ZART8D
XARS8D18H
ZART8L ZART8LZARB12W ZARB12H
XARS8L12W
ZARB18H
ZART12D ZART12D
XARS12D18W
ZARB18W
XARS12D18H
XARS8L12H
1/8
ZARB18H
XARS8D18p / XARS12D18p / XARS8L12p
Main characteristics
WARNING
UNINTENDED EQUIPMENT OPERATION
Install and operate this equipment according to the environmental conditions described in the operating limits.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
Base station ZARBppp
272 (ZARBpW)
10.7
264,8 (ZARBpH)
mm
in.
10.42
9.5
241,2
291
11.46
87,6
3.44
ZARB••H
ZARB••W
www.schneider-electric.com
34
2
1
STATUS
COM
POWER
356 12
STATUS
COM
POWER
1 : M12 for external antenna (covered by cap)
2 : Status LEDs
3 : M20 for the safeguarding function input wires (covered by cap)
4 : 62 pins connector
5 : M25 for output wires (covered by cable gland)
6 : M25 for detected applicative alarms input wires (covered by cap)
Specifications
Details Values
ZARB12H ZARB12W ZARB18H ZARB18W
Operating voltage
Current consumption
(maximum current in
connected or not
connected state)
AC/DC power supply Min…max
For 24V DC
For 24V AC
For 48V DC
24...48 V AC/DC ± 20%
24...240 V AC/DC ± 20%
For 48V AC
For 240V DC
For 240V AC
Operating temperature
For 24...48 V AC/DC power supply
For 48...130 V AC/DC power supply
For 130...240 V AC/DC power supply
Degree of protection IP65 / NEMA 4
-
--44 mA 44 mA
--250 mA 250 mA
-25...70°C (-13...158°F)
-
-
-25...70°C (-13...158°F)
-25...50°C (-13...122°F)
Remote control ZARTppp
mm
in.
323
12.72
92
3.62
111
4.37
Specifications
Operating radio range
Operating temperature
Details Values
Free field
Operating temperature to charge battery 10...40°C (50...104°F)Office environment
Degree of protection
- IP65 / NEMA 4
24...48 V AC/DC ± 20%
328 mA
535 mA
155 mA
312 mA
ZART8L ZART8D ZART12D
> 300 m
-20...60°C (-4...140°F)-
24...240 V AC/DC ± 20%
-
-
-25...70°C (-13...158°F)
-25...50°C (-13...122°F)
Charger for remote device
36,0 ± 1
1.42 ± 0.04
mm
in.
NHA45689 02
09 - 2016
53,0 ± 1
2.09 ± 0.04
99,0 ± 1
102,0 ± 1
3.90 ± 0.04
4.02 ± 0.04
900 - 1000
35.43 - 39.37
Output Plug :
Ø 5.5 x Ø 2.5 x 11.0 mm
Inner Positive
8,0 ± 1
0.31 ± 0.04
Specifications
Operating voltage
Operating temperature
Degree of protection
2/8
Details Values
Office environment
-
110 / 240 VAC
0...40°C (32...104°F)
IP20
XARS8D18p / XARS12D18p / XARS8L12p
Wiring
WARNING
UNINTENDED EQUIPMENT OPERATION
p Use shielded cables wherever specified for inpunts and outputs connections.
p Properly ground the cable shields as indicated in the related documentation.
p Route I/O cables separately from power cables.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
Base station terminal wiring
ZARB18W
Q0B_1
Q0B_2
Q0A_1
PE
AC_Neutral /-
AC_Phase /+
PE
Q0A_2
CC_X
CT_1
CT_3
CT_2
CC_Y
CT_4
CT_6
www.schneider-electric.com
WARNING
UNINTENDED EQUIPMENT OPERATION
Connect the Base Station protective earth ground connection to the
machine ground.
Failure to follow these instructions can result in death, serious
injury, or equipment damage.
IN_COM
IN_COM
S2_S3
IN0
CT_8
CT_9
CT_7
CC_Z
CT_5
CC_10
CC_11
CT_10
CT_11
CT_12
CC_12
CT_13
CC_13
CT_14
CC_14
CT_15
CC_15
CT_16
CC_16
CT_17
CC_17
CT_18
CR_17
IN_COM
IN0
CC_18
IN_COM
S2_S3
IN14
CR_18
IN18
IN13
IN10
IN17
IN9
IN11
IN15
IN12
IN7
IN16
IN8
IN4
IN6
IN2
IN5
IN3
IN1
ZARB12W
Base station ZARBppH - Connector pin out
A : Pin number
B : ZARB18H description
C : ZARB12H description
A
10
11
12
13
14
15
16
B
CR_18 - -
1
CC_18
2
CT_18
3
CT_13
4
CR_17
5
CC_17
6
CT_17
7
CC_13
8
CT_14
9
CC_12
CT_11
CC_10
CC_14
CT_12
CC_11
CT_10
C
-
-
-
-
-
-
-
CC_12
CT_11
CC_10
CT_12
CC_11
CT_10
A
17
CT_16
18
CT_15
19
S2/S3 S2/S3
20
21
CC_16
22
CC_15
23
24
25
CT_9
26
CT_8
27
CT_5
28
IN_COM
29
CC_Z
30
CT_6
31
CT_4
32
IN3
IN2
IN0
Q0B_1
Q0B_2
Q0A_1
Q0A_2
AC_Neutral /-
AC_Phase /+
PE
PE
53
57
60
54
61
58
55
59
62
56
B
C
-
-
-
-
--
-
CT_9
CT_8
CT_5
CC_Z
CT_6
CT_4
IN0
CT_3
CT_1
CC_X
37
41
45
49
38
42
46
50
39
43
47
51
40
44
48
52
A
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
CT_6
CT_4
CC_Y
CT_2
21
25
29
33
22
26
30
34
23
27
31
35
24
28
32
36
B
CT_7 CT_7
CC_Y CC_Y
CT_2 CT_2
IN1
Q0A_1 Q0A_1
Q0A_2 Q0A_2
CT_3 CT_3
IN4
Q0B_1 Q0B_1
Q0B_2 Q0B_2
CT_1 CT_1
IN5
PE PE
-
CC_X CC_X
IN6
CT_5
CC_Z
17
18
19
20
CT_7
13
14
15
16
CT_9
9
10
11
12
CT_8
C
-
-
-
-
-
CT_12
CC_12
CT_11
CC_11
CT_10
CC_10
1
5
2
6
3
7
4
8
A
49 - 50
51
52
53
54
55
56
57
58
59
60
AC_Neutral
61
62
AC_Phase
B
--
--
--
--
--
--
-
-
-
-
-
C
-
-
-
-
AC_Neutral
-
AC_Phase
Cable length maximum 50 m (164 ft)
DANGER
FIRE HAZARD
Use only the recommended wire sizes for I/O channels and power supplies.
Failure to follow these instructions will result in death or serious injury.
7
mm
0.28
in.
2
mm
AWG
Ø 3,5 mm (0.14 in.)
NHA45689 02
09 - 2016
0.2…2.5
24…14
0.2…2.5
24…14
0.25…2.5
23...14
0.25…2.5
23...14
N•m
lb-in
2 x 0.2…1
2 x 24…17
0.5...0.6
4.42...5.31
NOTICE
INOPERABLE EQUIPMENT
Do not tighten screw terminals beyond the specified maximum torque (Nm / lb-in.).
Failure to follow these instructions can result in equipment damage.
2 x 0.2…1.5
2 x 24…16
3/8
2 x 0.25…1
2 x 23…17
2 x 0.5...1.5
2 x 20...16