NetBotz Camera Pod 165
Installation and Quick Start
NBPD0165
Customer support and warranty information is available at
www.apc.com.
© 2018 APC by Schneider Electric. All rights reserved.
990-5974-001 10/2018
Inventory
aem0556a
Item Description Quantity
Camera Pod 165 1
Rubber bracket cover 1
T-bar mounting plate 1
Set screw* 1
Hex wrench* 1
Ball-joint adjuster arm 2
Extender arm 2
Mounting plate 1
*Not used
Installation
Choose the mounting option (rack, wall, or ceiling) that meets your needs.
Then connect the Camera Pod 165 to your NetBotz appliance or to the
network.
Rack mount
Use a #32 drill to make four 2.94 mm (0.116 in) pilot holes in the rack.
(Screws not provided.)
aem0283c
Product Description
The APC by Schneider Electric® NetBotz Camera Pod 165 is a motionsensitive camera capable of sending image data through a connection to
a NetBotz Rack Monitor 750. The Camera Pod 165 can be triggered by
the appliance in response to a number of environmental alarms or
events, such as a temperature spike or the action of opening a door. The
Camera Pod 165 can also provide constant surveillance of an area or
entrance.
Attention: THE EQUIPMENT CONTAINS, AND THE SOFTWARE
ENABLES, VISUAL RECORDING CAPABILITIES, THE IMPROPER
USE OF WHICH MAY SUBJECT YOU TO CIVIL AND CRIMINAL
PENALTIES. APPLICABLE LAWS REGARDING THE USE OF SUCH
CAPABILITIES VARY BETWEEN JURISDICTIONS AND MAY
REQUIRE AMONG OTHER THINGS EXPRESS WRITTEN CONSENT
FROM RECORDED SUBJECTS. YOU ARE SOLELY RESPONSIBLE
FOR INSURING STRICT COMPLIANCE WITH SUCH LAWS AND FOR
STRICT ADHERENCE TO ANY/ALL RIGHTS OF PRIVACY AND
PERSONALTY. USE OF THIS SOFTWARE FOR ILLEGAL
SURVEILLANCE OR MONITORING SHALL BE DEEMED
UNAUTHORIZED USE IN VIOLATION OF THE END USER
SOFTWARE AGREEMENT AND RESULT IN THE IMMEDIATE
TERMINATION OF YOUR LICENSE RIGHTS THEREUNDER.
Physical Description
aem0555a
Item Description
RJ-45 port For network and PoE connections.
Network LEDs Link LED: turns green to indicate a good network connection.
Activity LED: flashes orange to indicate network activity
Power jack Reserved for future use
Alarm In/Out Reserved for future use
Mounting hole Used to mount the Camera Pod 165
Micro SD card slot Reserved for future use
Reset button Press for at least 20 seconds to reset to factory defaults
Ceiling mount
aem0285c
Wall mount
(Screws not provided.)
aem0284c
Connect the Camera Pod 165 to the appliance
Use a Power over Ethernet (PoE) ready, CAT-5 Ethernet cable to
connect the Camera Pod 165 to the Private LAN port of the Rack
Monitor 750.
Connect the Camera Pod 165 to your network
Use a PoE ready, CAT-5 Ethernet cable; PoE equipment; and a network
switch to connect the Camera Pod 165 to your network.
Configuration
See the Rack Monitor 750 User Guide on www.apc.com for instructions
to configure the camera in the Web User Interface (UI) of the Rack
Monitor 750.
The Camera Pod 165 is automatically set to have a dynamic IP address
assigned via DHCP. When the Camera Pod 165 is not connected to a
Rack Monitor 750, you can use Device Search to view the current IP
address of the Camera Pod 165 or to assign a static IP address to the
Camera Pod 165.
Adjust the focus
Remove the lens cover. Twist the lens to the right to focus on objects closer to
the Camera Pod 165. Twist the lens to the left to focus on objects farther from
the Camera Pod 165.
Upgrade the Firmware
You can find firmware upgrades for the Camera Pod 165 on the applicable
product page of www.apc.com.
See the Frequently Asked Questions (FAQ) article
FA355195 for instructions to
upgrade the firmware. Go to www.apc.com. Navigate to Support >
Resources > FAQS, then enter the article number in the search bar.
Specifications
Electrical
Power Source Power over Ethernet
Power Consumption: Operation
(802.3af) system
Mechanical
Dimensions (H x W x L) 96.51 x 56 x 61.4 mm (3.78 x 2.2 x 2.42 in.)
Weight 120 g (0.26 lb)
Environmental
Operating temperature 0–45°C (32–113° F)
Humidity 10–90%, no condensation
Compliance
3.7 W
CE
FCC
Two-Year Factory Warranty
This warranty applies only to the products you purchase for your use in accordance with this
manual.
WARRANTIES AND REMEDIES. THE WARRANTIES SET FORTH ABOVE
CONSTITUTE APC BY SCHNEIDER ELECTRIC’S SOLE LIABILITY AND
PURCHASER’S EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES.
APC BY SCHNEIDER ELECTRIC WARRANTIES EXTEND ONLY TO PURCHASER AND
ARE NOT EXTENDED TO ANY THIRD PARTIES.
IN NO EVENT SHALL APC BY SCHNEIDER ELECTRIC, ITS OFFICERS, DIRECTORS,
AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT, SPECIAL,
CONSEQUENTIAL OR PUNITIVE DAMAGES, ARISING OUT OF THE USE, SERVICE
OR INSTALLATION, OF THE PRODUCTS, WHETHER SUCH DAMAGES ARISE IN
CONTRACT OR TORT, IRRESPECTIVE OF FAULT, NEGLIGENCE OR STRICT
LIABILITY OR WHETHER APC BY SCHNEIDER ELECTRIC HAS BEEN ADVISED IN
ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES. SPECIFICALLY, APC BY
SCHNEIDER ELECTRIC IS NOT LIABLE FOR ANY COSTS, SUCH AS LOST PROFITS
OR REVENUE, LOSS OF EQUIPMENT, LOSS OF USE OF EQUIPMENT, LOSS OF
SOFTWARE, LOSS OF DATA, COSTS OF SUBSTITUENTS, CLAIMS BY THIRD
PARTIES, OR OTHERWISE.
NO SALESMAN, EMPLOYEE OR AGENT OF APC BY SCHNEIDER ELECTRIC IS
AUTHORIZED TO ADD TO OR VARY THE TERMS OF THIS WARRANTY. WARRANTY
TERMS MAY BE MODIFIED, IF AT ALL, ONLY IN WRITING SIGNED BY AN APC BY
SCHNEIDER ELECTRIC OFFICER AND LEGAL DEPARTMENT.
Warranty claims
Customers with warranty claims issues may access the APC by Schneider Electric
customer support network through the Support page of the APC by Schneider Electric Web
site, www.apc.com/support. Select your country from the country selection pull-down
menu at the top of the Web page. Select the Support tab to obtain contact information for
customer support in your region.
Radio Frequency Interference
USA—FCC
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
European Union
This product is in conformity with the requirements of EU Council Directive 2014/53/EU.
This product may cause radio interference in which case the user may be required to take
adequate measures. APC by Schneider Electric cannot accept responsibility for any failure
to satisfy the protection requirements resulting from an unapproved modification of the
product.
Use Device Search to discover the IP address
1. Connect your computer to the same subnet as the
Camera Pod 165.
2. Go to the CameraPod 165 product page on www.apc.com.
Download and open the DeviceSearch executable file.
3. In the Device Search window, select All NetCard from the Local
Broadcast drop down list and click Device Search. Wait for the
search to finish. You can identify you Camera Pod 165 by its MAC
address, which you can find on the back of the unit.
Use Device Search to set a static IP address
1. Follow the instructions to discover the IP address of the
Camera Pod 165.
2. In the Device Search window, right-click the Camera Pod 165,
and select Network Setup to open the Network Setup window.
3. Select Static IP, and enter the static IP address, default gateway
(Gateway), Subnet Mask (Netmask), and Domain Name System
server (DNS) for your Camera Pod 165.
Terms of warranty
APC by Schneider Electric warrants its products to be free from defects in materials and
workmanship for a period of two years from the date of purchase. APC by Schneider Electric will
repair or replace defective products covered by this warranty. This warranty does not apply to
equipment that has been damaged by accident, negligence or misapplication or has been altered
or modified in any way. Repair or replacement of a defective product or part thereof does not
extend the original warranty period. Any parts furnished under this warranty may be new or
factory-remanufactured.
Non-transferable warranty
This warranty extends only to the original purchaser who must have properly registered the
product. The product may be registered at the APC by Schneider Electric Web site, www.apc.com.
Exclusions
APC by Schneider Electric shall not be liable under the warranty if its testing and examination
disclose that the alleged defect in the product does not exist or was caused by end user’s or any
third person’s misuse, negligence, improper installation or testing. Further, APC by Schneider
Electric shall not be liable under the warranty for unauthorized attempts to repair or modify wrong
or inadequate electrical voltage or connection, inappropriate on-site operation conditions, corrosive
atmosphere, repair, installation, exposure to the elements, Acts of God, fire, theft, or installation
contrary to APC by Schneider Electric recommendations or specifications or in any event if the
APC by Schneider Electric serial number has been altered, defaced, or removed, or any other
cause beyond the range of the intended use.
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, BY OPERATION OF LAW OR
OTHERWISE, OF PRODUCTS SOLD, SERVICED OR FURNISHED UNDER THIS AGREEMENT
OR IN CONNECTION HEREWITH. APC BY SCHNEIDER ELECTRIC DISCLAIMS ALL IMPLIED
WARRANTIES OF MERCHANTABILITY, SATISFACTION AND FITNESS FOR A PARTICULAR
PURPOSE. APC BY SCHNEIDER ELECTRIC EXPRESS WARRANTIES WILL NOT BE
ENLARGED, DIMINISHED, OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL
ARISE OUT OF, APC BY SCHNEIDER ELECTRIC RENDERING OF TECHNICAL OR OTHER
ADVICE OR SERVICE IN CONNECTION WITH THE PRODUCTS. THE FOREGOING
WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER