Rockwell Automation 440R-MSR41 User Manual

MSR41 Safety Module User Manual
Important User Information
Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements, including any applicable laws, regulations, codes and standards.
Throughout this manual we use notes to make you aware of safety considerations:
The illustrations, charts, sample programs and layout examples shown in the guide are intended solely for purposes of example. Since there are many variables and requirements associated with any particular installation, Rockwell Automation does not assume responsibility or liability (to include intellectual property liability) for actual use based upon the examples shown in this publication.
Rockwell Automation publication SGI-1.1, Safety Guidelines for the Application, Installation and Maintenance of Solid-State Control (available from your local Rockwell Automation sales oce), describes some important dierences between solid-state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication.
It is recommended that you save this user manual for future use.
Identies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss.
Identies information that is critical for successful application and understanding of
the product.
Identies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequences.
SHOCK HAZARD
Labels may be on or inside the equipment (for example, drive or motor) to alert people that dangerous voltage may be present.
BURN HAZARD
Labels may be on or inside the equipment (for example, drive or motor) to alert people that surfaces may reach dangerous temperatures.
WARNING
IMPORTANT
ATTENTION
MSR41 Safety Module User Manual
Expansion modules
Main module
Content
Approvals and Conformity . . . . . . . . . . . . . . . . . . . . . . . . 2
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Special features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Typical applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Application restrictions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Te rminal connection diagram . . . . . . . . . . . . . . . . . . . . . 3
Status outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
LED display elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
MSR41 base module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Response time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Mounting location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Cable and wires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Earth connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Micro400 light curtain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Start mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Output monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
MSR41 units can only achieve their function as a safety controller module, if the instructions given in this instruction manual and the within mentioned documents are exactly followed, as well as consulting the valid laws and regulations at the time of installation. Should these instructions not be carefully followed, serious injury or death may occur. The installer or system integrator will be fully responsible for a safe integration of this product. This instruction manual is to be used in conjunction with the MSR41 base module. It must be kept accessible together with the other machine documentation during its entire life cycle for all personnel responsible for assembly, installation, operation and maintenance.

Introduction

MSR41 is a extremely compact safety module. This main controlling module allows the connection and the control of the compact GuardShield Micro400 safety light curtain systems (Figure 1).
Selection tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Accessories / Components. . . . . . . . . . . . . . . . . . . . . . . . . 6
Inspection and service . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Inspections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Decommissioning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Product labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Te ch n ical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
EC Declaration of Conformity. . . . . . . . . . . . . . . . . . . . . . . 7

Approvals and Conformity

The safety approval, performed by TÜV Rheinland. The actual list of relevant safety data and applied standards are given in this document.
Figure 1: MSR41 controller and GuardShield Micro400 Safety Light curtain
The base module offers two safety PNP outputs (OSSD). Additional expansion modules (MSR45E) can be applied for applications, which require more outputs and/or dry contacts to switch loads

Special features

The outstanding characteristics of the MSR41 controller:
• Category 4, PL e according EN ISO 13849-1
• Type 4 according EN 61496-1/-2
• SIL 3 according IEC 61508
• SIL CL 3 according EN 62061
• Short response times
•Modular expansible
• Up to 3 expansion modules per main module
• Different start modes by hardware selectable
Original instructions
1
MSR41 Safety Module User Manual

Applications

Typical applications

MSR41 controller modules are developed and conceived for typical applications like:
• Robotic cells
•Assembly lines
• Indexing tables
• Conveyor systems
• Automatic storage facilities

Application restrictions

MSR41 modules are not intended for application in explosive (EX) or in radioactive environments.

Dimensions

The dimensions of the housing for MSR41 are illustrated in Figure 2.

Te rminal connection diagram

The following figures shows the connection possibilities for the MSR41 base module:
Figure 3: MSR41 Base module, Micro 400 LightCurtain, automatic start, no output monitoring
Figure 2: Base module dimensions are the same for expansion modules
Figure 4: MSR41 Base module, Micro 400 LightCurtain, manual start, no output monitoring
Figure 5: MSR41 Base module, Micro 400 Light Curtain, manual start, output monitoring
2
Original instructions