Rockwell Automation 2198-BARCON-165DC200, 2198-BARCON-100DC200, 2198-BARCON-55DC200, 2198-BARCON-220DC200, 2198-BARCON-85DC200 Installation Instructions Manual

...
Page 1
Installation Instructions
Original Instructions
Kinetix 5700 DC-bus Link Kits
Catalog Numbers 2198-BARCON-55DC200, 2198-BARCON-85DC200, 2198-BARCON-100DC200, 2198-BARCON-165DC200, 2198-BARCON-220DC200, 2198-BARCON-275DC200, 2198-BARCON-440DC200, 2198-KITCON-ENDCAP200
The Kinetix® 5700 DC-bus link kits are used to extend DC-bus power from drive-to-drive in DC-bus multi-axis configurations. DC-bus links are rated for 208 A, maximum bus-bar current.
Topi c Page
Added 2198-Dxxx-ERS4 and 2198-Sxxx-ERS4 servo drive catalog numbers. However, when the Kinetix 5700 inverter catalog
number ends in -ERSx, for example 2198-D057-ERSx, the variable (x) indicates that the inver ter catalog number (by using this example) can be 2198-D057-ERS3 or 2198-D057-ERS4.
Updated the DC-bus link maximum bu s-bar current.
Added DC-bus link kit catalog numbers to the table in support of the Kinetix 5700 regenerative bus supply.
Corrected the DC-bus end cap catalog number.

DC-bus Link Kit Applications

Throughout
1Added the iTRAK® power supply catalog number (2198-W25K-ER) to the table.
DC-bus Link Kit Cat. No.
2198-BARCON-55DC200 Dual-axis inverter
2198-BARCON-85DC200
2198-BARCON-100DC200
2198-BARCON-165DC200
2198-BARCON-275DC200 2198-RP200 DC-bus link, 275 mm, 208 A
2198-BARCON-440DC200
2198-BARCON-220DC200 Single-axis inverter
2198-KITCON-ENDCAP200 DC-bus supply
(1) When two or three 2198-P208 DC-bus supplies are connected in parallel, one 85 mm DC-bus link is required for each additional power supply.
Kinetix 5700 Drive Module Type
Dual-axis inverter 2198-D057-ERSx
(1)
Single-axis inverter
Single-axis inverter 2198-S160-ERSx
iTRAK power supply 2198-W25K-ER
Regenerative Bus Supply
Kinetix 5700 Drive Module Cat. No.
2198-D006-ERSx
2198-D012-ERSx
2198-S086-ERSx
2198-S130-ERSx
2198-RP088 DC-bus link, 165 mm, 208 A
2198-RP263
2198-RP312
2198-S263-ERSx
2198-S312-ERSx
2198-P031
2198-P070
2198-P141
2198-P208
2198-D020-ERSx
2198-D032-ERSx
2198-RP088
2198-RP200
2198-RP263
2198-RP312
Description
DC-bus link, 55 mm, 208 A
DC-bus link, 85 mm, 208 A
DC-bus link, 100 mm, 208 A
DC-bus link, 440 mm, 208 A
DC-bus link, 220 mm, 208 A
DC-bus end caps, 208 A
See the Kinetix 5700 Servo Drives User Manual, publication 2198-UM002, for detailed information on wiring, applying power, troubleshooting, and integration with Logix 5000™ controllers.
Page 2
Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400

Install the DC-bus Links

IMPORTANT
Kinetix 5700 Drive System
End Caps (2)
DC-bus Link, 85 mm
Zero- stack Tab
and Cutout Engaged
DC-bus Link Latch Example
(1)
DC-bus Link, 55 mm
DC-bus Link, 100 mm
(seated)
DC power supply is mounted
leftmost followed by drive
with largest amp rating.
Latch
Align the DC-bus link lower pivots with the
latches and push
downward until they latch.
Upper Pivot
Lower Pivot
Dual-axis Inverter, 55 mm
Single-axis Inverter, 85 mm
Single-axis Inverter, 100 mm
DC-bus Power Supply
DC Link Latched
ATTENTION: To avoid hazard of electrical shock, perform all mounting and wiring of the Kinetix 5700 drives and DC-bus link kits before applying power. Once power is applied, connector terminals can have voltage present even when not in use.
When the shared-bus connection system is used, the zero-stack tab and cutout must be engaged between adjacent drive modules.
The DC-bus connection system is comprised of two components:
DC-bus links that are inserted between drive modules to extend the DC bus from drive
to drive
DC-bus end caps that are inserted into the first and last drive modules to cover the
exposed DC-bus connector on both ends of the bus
This example configuration illustrates the shared DC-bus connection system and consists of one 2198-P208 DC-bus power supply, one 2198-S160-ERSx single-axis inverter, one 2198-S086-ERSx single-axis inverter, and one 2198-D006-ERSx dual-axis inverter.
(1) DC-bus links latch on both sides when inserted into the DC-bus connectors. To remove the DC-bus link, verify that there is no bus voltage present,
depress both sets of upper pivots to unlatch the lower pivots, and hold the DC-bus link firmly while pulling upward.
Rockwell Automation maintains current produc t environmental information on its website at
http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product- environmental-compliance.page.
Allen-Bradley, iTRAK, Kinetix, Logix 5000, Rockwell Automation, and Rockwell Software are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.
Publication 2198-IN007C-EN-P - October 2018
Supersedes Publication 2198-IN007B-EN-P - May 2018 Copyright © 2018 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Loading...