Rockwell Automation 20G-755 User Manual

Installation Instructions
PowerFlex 755 IP00 Spare Parts Installation Information
ATT EN TI ON : Only qualified personnel familiar with adjustable frequency AC
drives and associated machinery should plan or implement the installation, start-up, and subsequent maintenance of the system. Failure to comply may result in personal injury and/or equipment damage.
ATT EN TI ON : To avoid an electric shock hazard, verify that the voltage on the bus capacitors has discharged completely before servicing. After removing power to the drive, wait 5 minutes for the bus capacitors to discharge. Measure the DC bus voltage at the DC+ and DC- TESTPOINT sockets on the front of the power module. The voltage must be zero.
ATT EN TI ON : HOT surfaces can cause severe burns. After disconnecting power allow time for cooling.
ATT EN TI ON : This drive contains ESD (Electrostatic Discharge) sensitive parts and assemblies. Static control precautions are required when installing, testing, servicing or repairing this assembly. Component damage may result if ESD control procedures are not followed. If you are not familiar with static control procedures, reference Guarding Against Electrostatic Damage, publication 8000-4.5.2 or any other applicable ESD protection handbook.
ATT EN TI ON : Hazard of permanent eye damage exists when using optical transmission equipment. This product emits intense light and invisible radiation. Do not look into module ports or fiber optic cable connectors.
PowerFlex 755 IP00 Spare Parts Installation Information
The following table lists the available termination kits and maximum current rating of each. Wiring to these kits must be sized to accomodate drive current and local codes.
Current Rating at Specified Drive Input Voltage
Termination Kit Frame Catalog Number
Converter (AC Input) 8 20-750-BUS2-F8 819A AC 755A AC 514A AC 499A AC Inverter (AC Output) 8 20-750-BUS3-F8 832A AC 800A AC 545A AC 530A AC Inverter (DC Bus) 8 20-750-BUS4-F8 957A DC 882A DC 601A DC 583A DC DC Input for Common Bus
Precharge Converter (AC Input) 9 20-750-BUS2-F9 1638A AC 1510A AC 1028A AC 998A AC
Inverter (AC Output) 9 20-750-BUS3-F9 1664A AC 1600A AC 1090A AC 1060A AC Inverter (DC Bus - 400/480V) 9 20-750-BUS4-F9 1914A DC 1764A DC N/A DC Input for Common Bus
Precharge Inverter (DC Bus - 600/690V) 9 20-750-BUS6-F9 N/A Converter (AC Input) 10 20-750-BUS2-F10 2457A AC 2265A AC 1542A AC 1497A AC
Inverter (AC Output) 10 20-750-BUS3-F10 2496A AC 2400A AC 1635A AC 1590A AC Inverter (DC Bus - 400/480V) 10 20-750-BUS4-F10 2871A DC 2646A DC N/A DC Input for Common Bus
Precharge Inverter (DC Bus - 600/690V) 10 20-750-BUS6-F10 N/A
(1) N/A - not to be used in this configuration.
8 20-750-BUS5-F8 957A DC 882A DC 601A DC 583A DC
9 20-750-BUS5-F9 1914A DC 1764A DC 1202A DC 1166A DC
10 20-750-BUS5-F10 2871A DC 2646A DC 1803A DC 1749A DC
380…400V AC 513…540V DC
480V AC 650V DC
(1)
(1)
N/A
N/A
600V AC 810V DC
(1)
1202A DC 1166A DC
(1)
1803A DC 1749A DC
690V AC 932V DC
(1)
(1)
N/A
N/A
(1)
(1)

Finding Specific Installation Information

Installation information for this part can be found in the PowerFlex 755 IP00, NEMA/UL Open Type Drive Installation Instructions, publication 750-IN020.
You can view or download publications at
http:/www.rockwellautomation.com/literature/
. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.