WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
• Read, understand and follow these instructions for safe installation and operation.
DO NOT
DISCARD
• Leave this manual with party responsible for use and operation.
DANGER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas sup­plier’s instructions.
- If you cannot reach your gas supplier, call the fi re department.
• Installation and service must be performed by a qualifi ed installer, service agency, or the gas supplier.
In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fi tter.
A CO detector shall be installed in the room where the appliance in installed.
This appliance may be installed as an OEM installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280 in the United States, or the Standard for Installation in Mobile Homes, CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s) of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed kit is used.
1Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 2
Read this manual before installing or operating this appliance.
Please retain this owner’s manual for future reference.
A. Congratulations
Congratulations on selecting a Quadra-Fire gas fi replace, an elegant and clean alternative to wood burning fi replaces. The Quadra-Fire gas fireplace you have selected is designed to provide the utmost in safety, reliability, and effi ciency.
As the owner of a new fi replace, you’ll want to read and carefully follow all of the instructions contained in this Owner’s Manual. Pay special attention to all cautions and warnings.
This Owner’s Manual should be retained for future reference. We suggest that you keep it with your other important documents and product manuals.
The information contained in this Owner’s Manual, unless noted otherwise, applies to all models and gas control systems.
Your new Quadra-Fire gas fi replace will give you years of durable use and trouble-free enjoyment. Welcome to the Quadra-Fire family of fi replace products!
We recommend that you record the following pertinent
Homeowner Reference Information
information about your fi replace.
Model Name: ___________________________________________ Date purchased/installed: __________________
Serial Number: __________________________________________ Location on fi replace: _____________________
Dealership purchased from: _______________________________ Dealer Phone: __________________________
Notes: _______________________________________________________________________________________
_____________________________________________________________________________________________
Listing Label Information/Location
Type of Gas
Gas and Electric Information
Not for use with solid fuel. (Ne doit pas entre utilise avec un combustible solide).
Type of Gas (Sorte De Gaz):
NATURAL GAS
Minimum Minimum Permissible Permissible
Approved Approved Minimum Minimum (De (De Gaz) Gaz) AcceptableAcceptable 0.00.0 in in w.c.w.c. (Po. (Po. Col. Col. d’eau)d’eau)
Maximum Maximum Pressure Pressure (Pression)(Pression) 0.00.0 in in w.c.w.c. (Po. (Po. Col. Col. d’eau)d’eau)
Maximum Maximum Manifold Manifold Pressure Pressure (Pression)(Pression) 0.00.0 in in w.c.w.c. (Po. (Po. Col. Col. d’eau)d’eau)
Minimum Minimum Manifold Manifold Pressure Pressure (Pression)(Pression) 0.00.0 in in w.c.w.c. (Po. (Po. Col. Col. d’eau)d’eau)
Total Total Electrical Electrical Requirements: Requirements: 000Vac, 000Vac, 00Hz., less than 00 Amperes
ALTITUDE:ALTITUDE: 0-0000 0-0000 FT.FT. 0000-0000FT.0000-0000FT. MAX. MAX. INPUT I NPUT BTUH:BTUH: 00,00000,000 00,00000,000 MIN. MIN. INPUT INPUT BTUH:BTUH: 00,00000,000 00,00000,000 ORIFICE ORIFICE SIZE:SIZE: #XXXXX#XXXXX #XXXXX#XXXXX
The model information regarding your specifi c fi replace can be found on the rating plate usually located in the control area of the fi replace.
R
Quadra-Fire, a brand of Hearth & Home Technologies 7571 215th Street West, Lakeville, MN 55044
This appliance must be installed in accordance with local codes, if any; if not, follow ANSI Z223.1 in the USA or CAN/CGA B149 installation codes. (Installer l’appareil selon les codes ou reglements
locaux ou, en l’absence de tels reglements, selon les codes d’installation
ANSI Z21XX-XXXX · CSA 2.XX-MXX
Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment.Adjustment.
IN IN CANADACANADA
Model:Model:
(Modele):(Modele):
SerialSerial
(Serie):(Serie):
MADE MADE IN IN USAUSA
XXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXX
Model Number
Serial Number
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 2
Page 3
Safety Alert Key:
• DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
• WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
• CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
• NOTICE: Used to address practices not related to personal injury.
Table of Contents
A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
B. Limited Lifetime Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1 Listing and Code Approvals
A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
B. Glass Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
C. BTU Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 6
E. Non-Combustible Materials Specifi cation. . . . . . . . . . . . . . 6
F. Combustible Materials Specifi cation . . . . . . . . . . . . . . . . . 6
G. Electrical Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
User Guide
2 Operating Instructions
A. Gas Fireplace Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
B. Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
C. Clear Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
D. Decorative Doors, Fronts and Surrounds . . . . . . . . . . . . . . 8
E. Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
F. Remote Controls, Wall Controls and Wall Switches . . . . . . 8
G. IPI Battery Tray/Battery Installation . . . . . . . . . . . . . . . . . . 9
H. Control Module Operation . . . . . . . . . . . . . . . . . . . . . . . . . 9
I. Before Lighting Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . 10
J. Lighting Instructions (IPI) . . . . . . . . . . . . . . . . . . . . . . . . . 11
K. After Appliance is Lit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
L. Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . 12
3 Maintenance and Service
A. Maintenance Tasks-Homeowner . . . . . . . . . . . . . . . . . . . 13
B. Maintenance Tasks-Service Technician . . . . . . . . . . . . . . 14
Installer Guide
4 Getting Started
A. Typical Appliance System. . . . . . . . . . . . . . . . . . . . . . . . . 16
B. Design and Installation Considerations . . . . . . . . . . . . . . 17
C. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . . 17
D. Inspect Appliance and Components . . . . . . . . . . . . . . . . . 17
5 Fireplace Size Requirements
A. Minimum Fireplace Opening . . . . . . . . . . . . . . . . . . . . . . 18
B. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 20
6 Termination Locations
A. Vent Termination Minimum Clearances . . . . . . . . . . . . . . 21
7 Installation Preparation
A. Inspection and Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . 22
B. Flue Damper. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
C. Gas Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
D. Fireplace Conversion Notice . . . . . . . . . . . . . . . . . . . . . . 22
E. Electrical Outlet Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
F. Remote Control Confi guration . . . . . . . . . . . . . . . . . . . . . 22
8 Installing Vent Pipe and Appliance
A. Vent Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
B. Venting Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
C. Connecting Vent Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
D. Placing, Securing and Leveling the Appliance . . . . . . . . . 25
E. Installing Adaptor and Termination Cap . . . . . . . . . . . . . . 26
9 Gas Information
A. Fuel Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
B. Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
C. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . 27
10 Electrical Information
A. Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
B. IntelliFireTM Plus Ignition System Wiring . . . . . . . . . . . . . . 28
C. IPI Battery Tray/Battery Installation . . . . . . . . . . . . . . . . . 29
D. Control Module Operation . . . . . . . . . . . . . . . . . . . . . . . . 29
E. Programming the RC300 to the Control Module . . . . . . . 29
11 Finishing
A. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 30
B. Remove the Shipping Materials . . . . . . . . . . . . . . . . . . . . 30
C. Inspect Firebox . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
12 Appliance Setup
A. Remove Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . 31
B. Remove the Shipping Materials . . . . . . . . . . . . . . . . . . . . 31
C. Inspect Firebox . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
D. Clean the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
E. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
F. Place the Lava Rock . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
G. Ember Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
H. Install the Log Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . 33
I. Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
J. Air Shutter Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
13 Troubleshooting
A. IntelliFire™ Plus Ignition System . . . . . . . . . . . . . . . . . . . 40
14 Reference Materials
A. Appliance/Decorative Front Dimension Diagrams . . . . . . 42
B. Vent Kits Components . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
C. Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
D. Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
= Contains updated information.
3Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 4
Parts Labor Gas Wood Pellet
EPA
Wood
Coal Electric Venting
XXXXXXX
All parts and material except as
covered by Conditions,
Exclusions, and Limitations
listed
Igniters, electronic components,
and glass
XXXXX Factory-installed blowers
X Firepots and burnpots
5 years 1 year X X Castings and baffles
7 years 3 years X X X
Manifold tubes,
HHT chimney and termination
10
years
1 year X Burners, logs and refractory
Limited
Lifetime
3 yearsXXXXX Firebox and heat exchanger
XXXXXXX
All replacement parts
beyond warranty period
Warranty Period
HHT Manufactured Appliances and Venting
1 Year
Components Covered
3 years
2 years
90 Days
B. Limited Lifetime Warranty
Hearth & Home Technologies
LIMITED LIFETIME WARRANTY
Hearth & Home Technologies, on behalf of its hearth brands (“HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer.
WARRANTY COVERAGE:
HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance will be free from defects in materials and workmanship at the time of manufacture. After installation, if covered compo­nents manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period, HHT will, at its option, repair or replace the covered components. HHT, at its own discretion, may fully discharge all of its obligations under such warranties by replacing the product itself or refunding the verified purchase price of the product itself. The maximum amount recoverable under this warranty is limited to the purchase price of the product. This warranty is subject to conditions, exclusions and limitations as described below.
WARRANTY PERIOD:
Warranty coverage begins on the date of original purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent, authorized HHT dealer/ distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of product shipment from HHT, regardless of the installation or occupancy date. The warranty period for parts and labor for covered components is produced in the following table.
The term “Limited Lifetime” in the table below is defined as: 20 years from the beginning date of warranty coverage for gas appliances, and 10 years from the beginning date of warranty coverage for wood, pellet, and coal appliances. These time periods reflect the minimum expected useful lives of the designated components under normal operating conditions.
XXX
X Molded refractory panels
X
See conditions, exclusions, and limitations on next page.
4021-645G 2/15 Page 1 of 2
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 4
Ignition Modules
Page 5
B. Limited Lifetime Warranty (continued)
WARRANTY CONDITIONS:
This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is available on the HHT branded websites.
This warranty is only valid while the HHT appliance remains at the site of original installation.
• This warranty is only valid in the country in which the HHT authorized dealer or distributor that sold the appliance resides.
Contact your installing dealer for warranty service. If the installing dealer is unable to provide necessary parts, contact the nearest HHT authorized dealer or supplier. Additional service fees may apply if you are seeking warranty service from a dealer other than the dealer from whom you originally purchased the product.
Check with your dealer in advance for any costs to you when arranging a warranty call. Travel and shipping charges for parts are not covered by this warranty.
WARRANTY EXCLUSIONS:
This warranty does not cover the following:
Changes in surface finishes as a result of normal use. As a heating appliance, some changes in color of interior and exterior surface finishes may occur. This is not a flaw and is not covered under warranty.
Damage to printed, plated, or enameled surfaces caused by fingerprints, accidents, misuse, scratches, melted items, or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes.
Repair or replacement of parts that are subject to normal wear and tear during the warranty period. These parts include: paint, wood, pellet and coal gaskets, firebricks, grates, flame guides, batteries and the discoloration of glass.
Minor expansion, contraction, or movement of certain parts causing noise. These conditions are normal and com­plaints related to this noise are not covered by this warranty.
Damages resulting from: (1) failure to install, operate, or maintain the appliance in accordance with the installation instructions, operating instructions, and listing agent identification label furnished with the appliance; (2) failure to install the appliance in accordance with local building codes; (3) shipping or improper handling; (4) improper opera­tion, abuse, misuse, continued operation with damaged, corroded or failed components, accident, or improperly/ incorrectly performed repairs; (5) environmental conditions, inadequate ventilation, negative pressure, or drafting caused by tightly sealed constructions, insufficient make-up air supply, or handling devices such as exhaust fans or forced air furnaces or other such causes; (6) use of fuels other than those specified in the operating instructions; (7) installation or use of components not supplied with the appliance or any other components not expressly authorized and approved by HHT; (8) modification of the appliance not expressly authorized and approved by HHT in writing; and/or (9) interruptions or fluctuations of electrical power supply to the appliance.
Non-HHT venting components, hearth components or other accessories used in conjunction with the appliance.
Any part of a pre-existing fireplace system in which an insert or a decorative gas appliance is installed.
HHT’s obligation under this warranty does not extend to the appliance’s capability to heat the desired space. Informa­tion is provided to assist the consumer and the dealer in selecting the proper appliance for the application. Consider­ation must be given to appliance location and configuration, environmental conditions, insulation and air tightness of the structure.
This warranty is void if:
The appliance has been over-fired or operated in atmospheres contaminated by chlorine, fluorine, or other damaging chemicals. Over-firing can be identified by, but not limited to, warped plates or tubes, rust colored cast iron, bubbling, cracking and discoloration of steel or enamel finishes.
The appliance is subjected to prolonged periods of dampness or condensation.
There is any damage to the appliance or other components due to water or weather damage which is the result of, but not limited to, improper chimney or venting installation.
LIMITATIONS OF LIABILITY:
The owner’s exclusive remedy and HHT’s sole obligation under this warranty, under any other warranty, express or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above. In no event will HHT be liable for any incidental or consequential damages caused by defects in the appliance. Some states do not allow exclusions or limitation of incidental or consequential damages, so these limitations may not apply to you. This warranty gives you specific rights; you may also have other rights, which vary from state to state. EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE.
4021-645G 2/15 Page 2 of 2
5Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 6
1
1
Listing and Code Approvals
A. Appliance Certifi cation
MODELS: QFI30FB-C, QFI35FB-C
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Heater
STANDARD: ANSI Z21.88-2014 • CSA 2.33-2014
This product is listed to ANSI standards for “Vented Gas Fireplace Heaters” and applicable sections of “Gas Burn­ing Heating Appliances for Manufactured Homes and Recreational Vehicles”, and “Gas Fired Appliances for Use at High Altitudes”.
Quadra-Fire gas inserts are designed for installations into solid fuel masonry or factory built fi replaces that have been installed in accordance with the National, Provincial, State and local building codes. Fireplaces are to be constructed of non-combustible materials and, in the absence of local or regional codes, meet criteria of NFPA 211. No additional outside air source is required.
NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen­tal room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet above 2000 feet.
• In CANADA: Reduce input rate 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility.
Check with your local gas utility to determine proper orifi ce size.
E. Non-Combustible Materials Specifi cation
Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 ºC shall be considered
non-combustible materials.
F. Combustible Materials Specifi cation
Materials made of or surfaced with wood, compressed pa­per, plant fi bers, plastics, or other material that can ignite and burn, whether fl ame proofed or not, or plastered or unplastered shall be considered combustible materials.
B. Glass Specifi cations
This appliance is equipped with 5 mm ceramic glass. Re­place glass only with 5 mm ceramic glass. Please contact your dealer for replacement glass.
C. BTU Specifi cations
Models
(U.S. or Canada)
QFI30FB-C (NG)
QFI30FB-C (LP)
QFI35FB-C (NG)
QFI35FB-C (LP)
US
(0-2000 FT)
CANADA
(2000-4500 FT)
US
(0-2000 FT)
CANADA
(2000-4500 FT)
US
(0-2000 FT)
CANADA
(2000-4500 FT)
US
(0-2000 FT)
CANADA
(2000-4500 FT)
Maximum
Input
BTU/h
36,000 17,000 33
33,250 16,750 34
36,000 19,000 50
31,000 15,500 51
40,000 20,000 31
37,000 19,250 32
38,000 19,000 49
35,000 17,000 50
Minimum
Input
BTU/h
Orifi ce
Size
(DMS)
G. Electrical Codes
NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA
70-latest edition or the Canadian Electric Code CSA C22.1.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 6
Page 7
2
2
Operating Instructions
User Guide
A. Gas Fireplace Safety
WARNING! DO NOT operate fi replace before reading and understanding operating instructions. Failure
to operate fi replace according to operating instructions could cause fi re or injury.
DANGER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
• Keep children away.
• CAREFULLY SUPERVISE children in same room as fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other ammable materials.
• Clothing, furniture, draperies, and other fl ammable materials must not be placed on or near the appliance.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals. DO NOT operate the appliance with the barrier removed. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance.
Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.
Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns.
• A physical barrier is recommended if there are at risk
individuals in the house.
• To restrict access to a fi replace or stove, install an
adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
• Install a switch lock or a wall/remote control with child
protection lockout feature.
• Keep remote controls out of reach of children.
• Never leave children alone near a hot fi replace, whether
operating or cooling down.
• Teach children to NEVER touch the fi replace.
• Consider not using the fi replace when children will be present.
Contact your dealer for more information, or visit: www. hpba.org/safety-information
To prevent unintended operation when not using your fi re- place for an extended period of time (summer months, vacation/trips, etc):
• Remove batteries from remote controls.
• Turn off wall controls.
• Turn off gas controls valve on standing pilot models.
B. Your Fireplace
WARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure
to operate fi replace according to operating instructions could cause fi re or injury.
APPLIANCE INSTALLED IN EXISTING
SOLID FUEL FIREPLACE
DECORATIVE DOORS
(NOT SHOWN)
SECTION 2.D.
FIXED GLASS ASSEMBLY
(NOT SHOWN) SECTION 12.I.
CLEAR SPACE
SECTION 2.C.
HEARTH
BATTERY BACKUP
ACCESS
SECTION 2.G.
Figure 2.1 General Operating Parts
MANTEL
SECTION 5.B.
7Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 8
C. Clear Space
WARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2.
Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage these objects.
APPLIANCE INSTALLED IN EXISTING
SOLID FUEL FIREPLACE
3 FT. IN FRONT OF FIREPLACE
CLEAR SPACE
E. Fixed Glass Assembly
See Section 12.I.
F. Remote Controls, Wall Controls and Wall
Switches
Follow the instructions supplied with the control installed to operate your fi replace:
For safety:
• Install a switch lock or a wall/remote control with child protection lockout feature.
• Keep remote controls out of reach of children.
See your dealer if you have questions.
Figure 2.2 Clear Space
D. Decorative Doors, Fronts and Surrounds
WARNING! Risk of Fire! Install ONLY doors, fronts or surrounds approved by Hearth & Home Technologies. Unapproved doors or fronts may cause appliance to over­heat.
This appliance has been supplied with an integral barrier to prevent direct contact with the fi xed glass panel. DO NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.
For more information refer to the instructions supplied with your decorative door or front.
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 8
Page 9
G. IPI Battery Tray/Battery Installation
The IntelliFireTM Plus system has a battery backup option. Battery longevity and performance will be affected by the service temperatures of this appliance.
NOTICE: Batteries should only be used as a power source in the event of an emergency such as an outage.
The removable battery tray is located in the lower left corner of the appliance next to the lower glass clip. Remove batteries from tray before sliding tray back into appliance. See Figure 2.3.
A notch on the right side of the tray engages the tray with the appliance. See Figure 2.4. To remove the tray, rotate the left side of the tray outward and pull to the left to disengage the notch. Place the batteries in the tray and return it to the closed position with the notch engaged in the appliance.
Figure 2.3 Location of Battery Tray
NOTCH
H. Control Module Operation
1. The control module has an ON/OFF/REMOTE selector
switch that must be set. See Figure 2.6.
OFF Position: Appliance will ignore all power inputs and
will not respond to any commands from a wall switch or remote. The unit should be in the OFF position during installation, service, battery installation, fuel conversion, and in the event that the control goes into LOCK-OUT mode as a result of an error code.
ON Position: Appliance will ignite and run continuously
in the HI fl ame setting, with no adjustment in fl ame output. This mode of operation is primarily used for initial installation or power outage operation with battery backup.
REMOTE Position: Appliance will initiate commands
from an optional wired wall switch and/or the wireless remote (RC300).
2. If using a wired wall switch with the module in REMOTE
mode, the fl ame output can be adjusted with the HI/LO selector switch on the module. See Figure 2.6. Note that the fl ame HI/LO selector switch will become inactive once an optional remote control (RC200/RC300) is programmed to the control module. Note that the control module will always ignite the fi replace on HI and remain so for the initial 10 seconds of operation. If the HI/LO is switched to the LO position, the fl ame output will automatically drop to the lowest setting after the fl ame has been established for 10 sec. After this 10 second period, the fl ame can be adjusted from HI to LO with the switch.
3. The control module has safety feature that automatically
shuts down the fi replace after 9 hours of continuous operation without receiving a command from the RC300 remote.
4. If you intend to use both an optional wired wall switch
and the RC300 remote control to operate your fi replace, the wall switch will override any commands given by the remote.
Figure 2.4 Pull Left Side of Tray Out and Disengage Notch
Figure 2.5 Battery Tray Pulled Out
MODULE
FLAME HI/LOW
SWITCH
Figure 2.6 Control Module
INDICATOR LED
STATUS
SELECTOR
SWITCH
NG/LP GAS-TYPE SELECTOR SWITCH
9Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 10
5. Module Reset Switch
This module may lock-out under certain conditions.
When this occurs, the appliance will not ignite or respond to commands. The module will go into lock-out mode by emitting three audible beeps, then continuously displaying a RED/GREEN error code at its status indicator LED.
• Check battery tray. Remove batteries if installed. Batteries should only be installed for use during power outages. See Section G.
• Locate the module reset switch. (SeeFigure 2.7).
• Set the module reset switch to the RESET position.
• Wait fi ve (5) minutes to allow possible accumulated gas to clear.
• Set the module reset switch to ON.
• Start the appliance.
WARNING! Risk of Explosion! DO NOT press the mod­ule reset switch more than one time within a fi ve minute time period. Gas may accumulate in fi rebox. Call a quali- ed service technician.
I. Before Lighting Fireplace
Before operating this replace for the rst time, have a qualifi ed technician:
• Verify all shipping materials have been removed from inside and/or underneath the fi rebox.
• Review proper placement of logs, ember material and/ or other decorative materials.
• Check the wiring.
• Check the air shutter adjustment.
• Ensure that there are no gas leaks.
• Ensure that the glass is sealed and in the proper position and that the integral barrier is in place.
WARNING! Risk of Fire/Asphyxiation! DO NOT oper­ate fi replace with fi xed glass assembly removed.
TM
This fi replace has an Intellifi re
Plus ignition system.
MODULE RESET SWITCH
Figure 2.7. Module Reset Switch
Nine Hour Safety Shutdown Feature
This appliance has a safety feature that automatically shuts down the fi replace after 9 hours of continuous operation without receiving a command from the RC300 remote.
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 10
Page 11
J. Lighting Instructions (IPI)
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury or loss of life.
A. This appliance is equipped with an intermittent pilot ignition (IPI) device which
automatically lights the burner. DO NOT try to light the burner by hand.
B. BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell
next to the fl oor because some gas is heavier than air and will settle on the fl oor.
WHAT TO DO IF YOU SMELL GAS
DO NOT try to light any appliance.
DO NOT touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas sup­plier’s instructions.
• If you cannot reach your gas supplier, call the fi re department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If
the knob will not push in or turn by hand, DO NOT try to repair it, call a qualifi ed service technician. Force or attempted repair may result in a fi re or explosion.
D. DO NOT use this appliance if any part has been under water. Immediately call
a qualifi ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS (IPI)
1. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand.
GAS
VALVE
2. Wait ve (5) minutes to clear out any gas. Then smell for gas, including near the oor. If you smell gas, STOP! Follow “B” in the Safety Information located on the
top of this label. If you do not smell gas, go to next step.
3. To light the burner:
Equipped with wall switch: Turn ON/OFF switch to ON. Equipped with remote or wall control: Press ON or FLAME button.
Equipped with thermostat: Set temperature to desired setting.
4. If the appliance does not light after three tries, call your service technician or gas supplier.
TO TURN OFF GAS TO APPLIANCE
1. Equipped with wall switch: Turn ON/OFF switch to OFF. Equipped with remote or wall control: Press OFF button. Equipped with thermostat: Set temperature to lowest setting.
2. Service technician should turn off electric power to the control when performing service.
DANGER
HOT GLASS WILL CAUSE BURNS.
DO NOT TOUCH GLASS UNTIL COOLED.
NEVER ALLOW CHILDREN TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
WARNING:
DO NOT CONNECT LINE VOLTAGE (110/120 VAC OR 220/240 VAC) TO THE CON­TROL VALVE.
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information, consult a qualifi ed installer, service agency or the gas supplier.
This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.
If not installed, operated, and maintained in accordance with the manufacturer’s in­structions, this product could expose you to substances in fuel or fuel combustion which are known to the State of California to cause cancer, birth defects, or other reproductive harm.
Keep burner and control compartment clean. See installation and operating instruc­tions accompanying appliance.
Hearth & Home Technologies fi replace, please refer to www.fi replaces.com.
For additional information on operating your
CAUTION:
Hot while in operation. DO NOT touch. Keep children, clothing, furniture, gasoline and other liquids having fl ammable vapors away.
DO NOT operate the appliance with fi xed glass assembly removed, cracked or broken. Replacement of the fi xed glass assembly should be done by a licensed or qualifi ed service person.
NOT FOR USE WITH SOLID FUEL
For use with natural gas and propane. A conversion kit, as supplied by the manufac­turer, shall be used to convert this appliance to the alternate fuel.
Also Certifi ed for Installation in a Bedroom or a Bedsitting Room.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSIZ223.1/ NFPA 54, or the National Gas and
Propane Installation code, CSA B149.1.
593-913i
11Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 12
K. After Appliance is Lit
Initial Break-in Procedure
• The appliance should be run three to four hours continuously on high.
• Turn the appliance off and allow it to completely cool.
• Remove fi xed glass assembly. See Section 12.I.
• Clean fi xed glass assembly. See Section 3.
• Replace the fi xed glass assembly and run continuously on high an additional 9 hours.
This cures the materials used to manufacture the fi re- place.
NOTICE! Open windows for air circulation during ap­pliance break-in.
• Some people may be sensitive to smoke and odors.
• Smoke detectors may activate.
L. Frequently Asked Questions
ISSUE SOLUTIONS
Condensation on the glass
Blue fl ames
Odor from appliance
Film on the glass
Metallic noise
Is it normal to see the pilot fl ame burn continually?
This is a result of gas combustion and temperature variations. As the appliance warms, this condensation will disappear.
This is a result of normal operation and the fl ames will begin to yellow as the appliance is al- lowed to burn for 20 to 40 minutes.
When fi rst operated, this appliance may release an odor for the fi rst several hours. This is caused by the curing of the paint and the burning off of any oils remaining from manufacturing. Odor may also be released from fi nishing materials and adhesives used around the appliance.
This is a normal result of the curing process of the paint and logs. Glass should be cleaned within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing process. A non-abrasive cleaner such as gas fi replace glass cleaner may be necessary. See your dealer.
Noise is caused by metal expanding and contracting as it heats up and cools down, similar to the sound produced by a furnace or heating duct. This noise does not affect the operation or longevity of the appliance.
In an intermittent pilot ignition system (IPI), the pilot fl ame should turn off when appliance is turned off. Some optional control systems available with IPI models may allow pilot fl ame to remain lit.
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 12
Page 13
3
3
Maintenance and Service
Any safety screen or guard removed for servicing must be replaced prior to operating the appliance.
When properly maintained, your appliance will give you many years of trouble-free service. We recommend an­nual service by a qualifi ed technician.
A. Maintenance Tasks-Homeowner
Installation and repair should be done by a qualifi ed techni- cian only. The appliance should be inspected before use and at least annually by a professional service person.
The following tasks may be performed annually by the homeowner. If you are uncomfortable performing any of the listed tasks, please call your dealer for a service ap­pointment.
More frequent cleaning may be required due to lint from carpeting or other factors. The control compartment, burner and circulating air passageway of the appliance must be kept clean.
CAUTION! Risk of Burns! The appliance should be turned off and cooled before servicing.
Glass Cleaning
Frequency: Seasonally
By: Homeowner
Tools Needed: Protective gloves, glass cleaner, drop
cloth and a stable work surface.
CAUTION! Handle fi xed glass assembly with care.
Glass is breakable.
• Avoid striking, scratching or slamming glass
• Avoid abrasive cleaners
DO NOT clean glass while it is hot
• Prepare a work area large enough to accommodate fi xed glass assembly and door frame by placing a drop cloth on a fl at, stable surface.
Note: Fixed glass assembly and gasketing may have res­idue that can stain carpeting or fl oor surfaces.
• Remove door or decorative front from appliance and set aside on work surface.
• See Section 12.I for instructions to remove fi xed glass assembly.
• Clean glass with a non-abrasive commercially available cleaner.
- Light deposits: Use a soft cloth with soap and water
- Heavy deposits: Use commercial fireplace glass
cleaner (consult with your dealer)
• Carefully set fi xed glass assembly in place on appliance. Hold glass in place with one hand and secure glass latches with the other hand.
• Reinstall door or decorative front.
Doors, Surrounds, Fronts
Frequency: Annually
By: Homeowner
Tools needed: Protective gloves, stable work surface
• Assess condition of screen and replace as necessary.
• Inspect for scratches, dents or other damage and repair as necessary.
• Check that louvers are not blocked.
• Vacuum or dust surfaces.
Remote Control
Frequency: Seasonally
By: Homeowner
Tools needed: Replacement batteries and remote con-
trol instructions.
• Locate remote control transmitter and receiver.
• Verify operation of remote. Refer to remote control operation instructions for proper calibration and setup procedure.
• Place batteries as needed in remote transmitters and battery-powered receivers.
• Place remote control out of reach of children.
If not using your fi replace for an extended period of time (summer months, vacations/trips, etc), to prevent unin­tended operation:
• Remove batteries from remote controls.
13Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 14
Venting
Frequency: Seasonally
By: Homeowner
Tools needed: Protective gloves and safety glasses.
• Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow, debris, etc.
• Verify termination cap clearance to subsequent construc­tion (building additions, decks, fences, or sheds). See Section 6.
• Inspect for corrosion or separation.
• Verify weather stripping, sealing and fl ashing remains intact.
• Inspect draft shield to verify it is not damaged or missing.
B. Maintenance Tasks-Service Technician
The following tasks must be performed by a qualifi ed technician.
Gasket Seal and Glass Assembly Inspection
Frequency: Annually
By: Service Technician
Tools needed: Protective gloves, drop cloth and a stable
work surface.
• Inspect gasket seal and its condition.
• Inspect fi xed glass assembly for scratches and nicks that can lead to breakage when exposed to heat.
• Confi rm there is no damage to glass or glass frame. Replace as necessary.
• Verify that fi xed glass assembly is properly retained and attachment components are intact and not damaged. Replace as necessary.
• Remove all foreign objects.
• Verify unobstructed air circulation.
Firebox
Frequency: Annually
By: Service Technician
Tools needed: Protective gloves, sandpaper, steel wool,
cloths, mineral spirits, primer and touch-up paint.
• Inspect for paint condition, warped surfaces, corrosion or perforation. Sand and repaint as necessary.
• Replace appliance if fi rebox has been perforated.
Surface cracking or crazing of fi rebrick material is normal and expected. All cracks are acceptable and do not require replacement of the unit or the fi rebox with the exception of:
• Cracks compromising the surface plane of the fi rebox.
See Figure 3.1.
Figure 3.1 Surface plane of fi rebox is comprised and should be replaced.
Logs
Frequency: Annually
By: Service Technician
Tools needed: Protective gloves.
• Inspect for damaged or missing logs. Replace as necessary. Refer to Section 12 for log placement instructions.
• Verify correct log placement and no fl ame impingement causing sooting. Correct as necessary.
Control Compartment and Firebox Top
Frequency: Annually
By: Service Technician
Tools needed: Protective gloves, vacuum cleaner, dust
cloths
• Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided.
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 14
Light Bulbs
Frequency: As needed
By: Service Technician
Tools needed: Protective gloves, replacement light
bulbs. 1/4 in. nut driver.
• Remove the glass frame. See Section 12.I.
• Remove the logs, grate, and burner.
• Remove the two ember glass retainer tabs.
• Remove the ember glass.
• Replace light bulb.
• Reassemble components in reverse order of disassembly.
Page 15
Burner Ignition and Operation
Frequency: Annually
By: Service Technician
Tools needed: Protective gloves, vacuum cleaner, whisk
broom, fl ashlight, voltmeter, indexed drill bit set, and a manometer.
• Verify burner is properly secured and aligned with pilot or igniter.
• Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary.
• Replace Glowing embers with new dime-size pieces. DO NOT block ports or obstruct lighting paths. Refer to Section 12 for proper ember placement.
• Verify batteries have been removed from battery back-up IPI systems to prevent premature degradation due to long term heat exposure.
• Check for smooth lighting and ignition carryover to all ports. Verify that there is no ignition delay.
• Inspect for lifting or other fl ame problems.
• Verify air shutter setting is correct. See Section 12 for required air shutter setting. Verify air shutter is clear of dust and debris.
• Inspect orifi ce for soot, dirt and corrosion. Verify orifi ce size is correct. See Service Parts List for proper orifi ce sizing.
• Verify manifold and inlet pressures. Adjust regulator as required.
• Inspect pilot fl ame pattern and strength. See Figure 3.2 for proper pilot fl ame pattern. Clean or replace orifi ce spud as necessary.
• Inspect IPI fl ame sensing rod for soot, corrosion and deterioration. Polish with fi ne steel wool or replace as required.
• Verify that there is not a short in fl ame sense circuit by checking continuity between pilot hood and fl ame sense rod. Replace pilot as necessary.
Figure 3.2 IPI Pilot Flame Patterns
15Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 16
4
Installer Guide
4
A. Typical Appliance System
NOTICE: Illustrations and photos refl ect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual
Getting Started
VERTICAL TERMINATION CAP (SECTION 8.E)
VENT PIPE (SECTION 8)
3 INCH FLEX LINERS (SECTION 8)
GAS LINE (SECTION 9) ACCESS THROUGH EXISTING MASONRY OR WOODBURNING FIREPLACE
MANTEL AND MANTEL LEG SECTION 5.B AND 11.A
SURROUND OR FRONT NOT SHOWN
SECTION 2.D AND SECTION 8.
HEARTH EXTENSION
Figure 4.1 Typical System
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 16
Page 17
B. Design and Installation Considerations
Quadra-Fire gas inserts are designed for installations into solid fuel masonry or factory built fi replaces that have been installed in accordance with the National, Provin­cial, State and local building codes. Fireplaces are to be constructed of non-combustible materials and, in the ab­sence of local or regional codes, meet criteria of NFPA
211. No additional outside air source is required.
Installation MUST comply with local, regional, state and na­tional codes and regulations. Consult insurance carrier, local building inspector, fi re offi cials or authorities having jurisdic- tion over restrictions, installation inspection and permits.
Prior to installing the gas insert:
• Have the chimney and adjacent structure inspected and cleaned by qualifi ed professionals. Hearth & Home Technologies recommends that NFI or CSIA certifi ed professionals, or technicians under the direction of certi­ ed professionals, conduct a minimum of a NFPA 211 Level 2 inspection of the chimney.
• Replace component parts of the chimney and fi replace as specifi ed by the professionals.
• Ensure combustible mantel and surround clearances comply with applicable codes and regulations for solid­fuel fi replaces. In the absence of local or regional codes, refer to NFPA 211.
• Ensure all joints are properly engaged and the chimney is properly secured.
• Minimum fi replace size. See Section 5.A.
• Gas supply piping requirements.
• Electrical wiring requirements.
• Finishing details.
• Whether optional accessories—devices such as a fan, wall switch, or remote control—are desired.
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualifi ed technician, service agency or your dealer.
Installation and service of this appliance should be performed by qualifi ed personnel. Hearth & Home Technologies suggests NFI certified or factory trained professionals, or technicians supervised by an NFI certifi ed professional.
C. Tools and Supplies Needed
Before beginning the installation be sure that the following tools and building supplies are available.
Tape measure Framing material Pliers Phillips screwdriver Gloves Framing square Voltmeter Electric drill and bits (1/4 in.) Plumb line Safety glasses Level Reciprocating saw Manometer Flat blade screwdriver Hammer Noncorrosive leak check solution 1/2 - 3/4 inch length, #6 or #8 Self-drilling screws
Caulking material (300ºF minimum continuous exposure rating)
D. Inspect Appliance and Components
• Carefully remove the appliance and components from the packaging.
• The vent system components and decorative doors and fronts may be shipped in separate packages.
• If packaged separately, the log set and appliance grate must be installed.
• Report to your dealer any parts damaged in shipment, particularly the condition of the glass.
Read all of the instructions before starting the instal-
lation. Follow these instructions carefully during the installation to ensure maximum safety and benefi t.
WARNING! Risk of Fire or Explosion! Damaged parts could impair safe operation. DO NOT install damaged, in- complete or substitute components. Keep appliance dry.
Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:
• Installation and use of any damaged appliance or vent
system component.
• Modifi cation of the appliance or vent system.
• Installation other than as instructed by Hearth & Home
Technologies.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not approved
by Hearth & Home Technologies.
Any such action may cause a fi re hazard.
WARNING! Risk of Fire,/Explosion/Electric Shock! DO NOT use this appliance if any part has been under
water. Call a qualifi ed technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water.
17Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 18
5
Fireplace Size Requirements
5
A. Minimum Fireplace Opening
Minimum fi replace opening requirements are shown in Figure 5.2.
WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat­ed out of traffi c and away from furniture and draperies.
• The fi rebrick (refractory), glass doors, screen rails, screen mesh and log grates can be removed from a factory built fi rebox in order to gain minimum gas insert opening requirements.
• Any smoke shelves, shields and baffl es may be removed from the factory built fi rebox if attached with mechanical fasteners.
SIDE VIEW
• The metal fl oor of the solid fuel fi rebox may be removed to facilitate the installation of the insert.
• Cutting of any sheet metal parts of the fi replace in which the gas fi replace insert is to be installed is prohibited, except the fl oor as tested for and as noted above and in Figure 5.1.
• A minimum 1/2 inch gap from the bottom of the appliance to the metal fl oor of the solid fuel fi rebox is RECOMMENDED for optimal fan performance. See side view in Figure 5.1.
TOP VIEW
11-1/4
METAL FLOOR OF EXISTING
IN.
SOLID FUEL FIREBOX
5 IN.
1/2 IN. MINIMUM LEVELING HEIGHT
(RECOMMENDED) 1/4 IN. REQUIRED
METAL FLOOR OF EXISTING SOLID FUEL FIREBOX
Figure 5.1-A
• The appliance may not be placed directly on the base of the outer wrap, a 1/4 inch airspace MUST be provided between the insert and the fl oor of the outer wrap. Use the levelling legs to raise the insert a minimum of 1/4 inch. The original fi replace may never be returned to solid fuel in this condition. The sidewalls and top structure of the fi rebox may not be altered with the exception of removable baffl es and dampers.
Figure 5.1-B
REMOVE THIS SECTION OF METAL FLOOR
11-1/4
IN.
REMOVE THIS SECTION OF METAL FLOOR
• If the recommended 1/2 inch leveling leg height can not be achieved, a section of the factory-built metal fl oor may be removed. See Figure 5.1-B.
QFI35FB-C QFI30FB-C
6 IN.
12 IN.
EXISTING FACTORY BUILT FIREBOX
6 IN.
12 IN.
5 IN.
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 18
Page 19
TOP VIEW
A
G**
H
B
E
FRONT VIEW
C
D
MINIMUM FIREPLACE SIZE
QFI35FB-C QFI30FB-C
Location
Inches Millimeters Inches Millimeters
A Rear Width 25-1/2 648 21-1/2 546
B Front Width 35 889 30-1/4 768
C Glass Opening Width 31-1/2 800 26-3/4 679
D Glass Opening Height 20 508 18 457
E Height-Front 24-7/8 632 22-7/8 581
F Height-Rear 22-1/4 565 20-5/8 524
F
G** Unit Depth 18-1/4 464 16-7/8 429
H Venting Depth 13-3/8 340 12-1/8 308
* Note: If exhaust collar on insert and fi replace damper do not line up, add 4 inches (102 mm) to minimum
replace height for bends in vent pipe.
**Unit depth is measured to the back of the surround to give the depth needed for installation.
In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.B).
Figure 5.2 Fireplace Opening
19Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 20
B. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear­ances to combustibles as specifi ed. Framing or fi nishing material closer than the minimums listed must be construct­ed entirely of noncombustible materials (i.e., steel studs, concrete board, etc).
Clearance to combustible material under the insert is 1/4 inch (6 mm). Clearance from top of fi replace opening for combustibles extending 12 inches max. is 12 inches.
• Use leveling legs to raise insert minimum 1/4 inch (6 mm) above combustible material or outer wrap of factory built rebox.
Combustible facings must not extend behind the insert surround. For non-combustible material specifi cations refer to section 1.E.
EXISTING NON-COMBUSTIBLE FACING
12 IN. MAX.
12 IN. MIN.
10 IN. MIN.
2 IN. MAX.
Figure 5.3 Mantel Clearance
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 20
Page 21
6
6
Termination Locations
A. Vent Termination Minimum Clearances
WARNING
Fire Risk.
Maintain vent clearance to combustibles as specifi ed.
DO NOT pack air space with insulation or other materials.
Failure to keep insulation or other materials away from vent pipe may cause fi re.
HORIZONTAL
OVERHANG
2 FT. MIN.
GAS DIRECT VENT TERMINATION CAP
Roof Pitch H (Min.) Ft.
Flat to 6/12...........................................................1.0*
Over 6/12 to 7/12 .................................................1.25*
Over 7/12 to 8/12 .................................................1.5*
Over 8/12 to 9/12 .................................................2.0*
Over 9/12 to 10/12 ...............................................2.5*
Over 10/12 to 11/12 .............................................3.25
Over 11/12 to 12/12 .............................................4.0
Over 12/12 to 14/12 .............................................5.0
Over 14/12 to 16/12 .............................................6.0
Over 16/12 to 18/12 .............................................7.0
Over 18/12 to 20/12 .............................................7.5
Over 20/12 to 21/12 .............................................8.0
* 3 foot minimum in snow regions
Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening
20 INCHES MIN.
LOWEST
DISCHARGE
OPENING
H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING
X
12
ROOF PITCH
IS X/ 12
VERTICAL
WALL
21Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 22
7
7
Installation Preparation
Prepare the existing solid fuel masonry or factory built non-combustible fi rebox for installation.
A. Inspection and Cleaning
Prior to installing the gas insert:
• Have the chimney and adjacent structure inspected and cleaned by qualifi ed professionals. Hearth & Home Technologies recommends that NFI or CSIA certifi ed professionals, or technicians under the direction of certi­ ed professionals, conduct a minimum of a NFPA 211 Level 2 inspection of the chimney.
• Replace component parts of the chimney and fi replace as specifi ed by the professionals.
• Ensure all joints are properly engaged and the chimney is properly secured.
• Ensure combustible mantel and surround clearances comply with applicable codes and regulations for solid­fuel fi replaces. In the absence of local or regional codes, refer to NFPA 211.
• Ensure chimney is constructed of non-combustible materials.
• Ensure chimney is clean and in good working order.
• Ensure that all chimney cleanouts fi t properly to prevent air leakage into chimney.
B. Flue Damper
Fully lock the solid fuel fi replace’s fl ue damper in the open position, OR completely remove it.
D. Fireplace Conversion Notice
Permanently attach the label with the following warning to the inside lower back of the fi replace fi rebox into which the insert is being installed. Silicone or mechanical fasteners may be required to properly secure the label.
WARNING! Risk of Fire! This fi replace has been con- verted for use with a gas fi replace insert only and cannot be used for burning wood or solid fuels unless all original parts have been replaced, and the fi replace re-approved by the authority having jurisdiction.
E. Electrical Outlet Box
An outlet box may be installed in a bottom back corner of the existing solid fuel masonry or factory built fi replace to permit blowers or other optional accessories to be used. Alternatively, the supplied power cord may be routed out onto the hearth to a nearby outlet.
F. Remote Control Confi guration
The Intellifi reTM Plus should be programmed to the RC300 remote control prior to the installation of the insert into the existing solid fuel masonry or factory built fi replace.
The control is accessed by removing the lower access panel on the left side of the insert. See Section 10.E.
C. Gas Line
Note: If the factory built replace has no gas access hole
provided, an access hole of 1 inch (25 mm) diameter or less may be drilled through the lower sides or bottom of the rebox in a proper workmanship - like manner. This access hole must be plugged with non-combustible insulation after the gas supply line has been installed.
• Install gas line into fi rebox cavity.
• Check local codes and gas line sizing requirements following NFPA51. See Section 9.
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 22
Page 23
8
8
Installing Vent Pipe and Appliance
A. Vent Limits
The abbreviations listed in this vent table key are used in the vent diagrams.
Description
Minimum Vertical Run Length 10 ft.
Maximum Vertical Run Length 50 ft.
Horizontal venting is NOT allowed.
Vertical terminations are measured to top of chimney.
This appliance is listed for use with LINK-DV systems and components only. It is permissible to extend venting above existing chimney (within specifi ed maximum verti- cal limits) using SL-D series or Dura Vent GS series 4 in. x 6-5/8 in. gas direct-vent pipe. Connection is made us­ing DV-46DVA-GK. The vent must be terminated with the cap supplied with the LINK-series vent kit.
WARNING! Risk of Fire/Explosion/Asphyxiation! Do NOT connect this gas appliance to a chimney fl ue serving a separate solid fuel or gas burning appliance.
• May impair safe operation of this appliance or other appliances connected to the fl ue.
• Vent this appliance directly outside.
• Use separate vent system for this appliance.
CAUTION! ALL vent specifi cations MUST be followed.
This product is tested and listed to these specifi cations. Appliance performance will suffer if specifi cations are not followed.
B. Venting Components
CAUTION! Risk of Cuts/Abrasions/Flying Debris.
Wear protective gloves and safety glasses during instal­lation. Sheet metal edges are sharp.
The vertical vent termination system installed on this model includes:
• One 3-foot section stainless steel fl exible pipe (included with insert).
• Flexible vent pipe for exhaust air (included with vent kit).
• One length of 3-inch fl exible vent pipe for combustion air (included with vent kit).
• One pipe-to-cap adaptor (included with vent kit).
• One vertical termination cap (included with vent kit).
HANDLE
ADAPTER
V = 10 FT. MINIMUM 50 FT. MAXIMUM
TERMINATION
CAP
INLET
COLLAR
EXHAUST
COLLAR
EXHAUST
AIR
VENT PIPE
INLET AIR VENT PIPE
INLET AIR STARTING COLLAR
STARTING COLLAR BRACKET
LOCKING TAB
EXHAUST STARTING COLLAR
NOTE: TO ACHIEVE OPTIMUM PERFOR­MANCE OF INSERT, MINIMIZE OR AVOID BENDS IN EXHAUST VENT PIPE.
INLET AIR STARTING COLLAR
STARTING COLLAR BRACKET
Figure 8.1
EXHAUST STARTING COLLAR
23Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 24
C. Connecting Vent Pipe
CUT AND BEND
FLASHING AS NEEDED
TO FIT CHIMNEY
SEALANT
ADHESIVE
Reference instructions in the termination kit.
• Install the 3-inch fl exible vent pipe(s) down through the chimney.
• Secure the exhaust fl exible vent pipe to the 3 foot section stainless steel flexible vent pipe using the factory­installed 3-inch collar in the stainless steel section of pipe (see Figure 8.1).
• Secure the stainless fl exible vent pipe to the exhaust starting collar on top of the appliance with three screws.
• Use 3 screws to attach the section of inlet air vent to the inlet collar on the collar slide plate. See Figure 8.1. NOTE: The collar slide plate may be removed from appliance to aid installation.
Figure 8.2
• Trim chimney top plate to minimize excess overhang or bend over fl ue tile (see Figure 8.2).
• Place 3/8 inch bead of silicone (300ºF minimum continuous exposure rating) on fl ue tile top.
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 24
Page 25
D. Placing, Securing and Leveling the
Appliance
WARNING! Risk of Explosion/Combustion Fumes!
Connect vent sections per installation instructions.
• The 3 foot section of stainless steel fl exible pipe MUST be attached directly to the exhaust collar on the collar slide plate.
• Connect exhaust vent pipe ONLY to exhaust starting collar and termination cap center collar.
• Connect inlet air vent ONLY to inlet air collar on appliance and either the termination cap inlet air collar OR terminate within chimney.
DO NOT allow vent to sag below connection point to appliance.
• Remove rear leveling legs from shipping position and relocate to one of the positions shown in Figure 8.3. Remove both screws that secure the leveling leg to the side of the appliance. Turn the leveling leg around so that the foot is facing out and downward. Line up the two holes on the leg with the holes on the appliance and secure with screws. See Figure 8.3.
• Front leveling legs are shipped with surround and may be installed in one of two locations. See Figure 8.3.
• Install insert (without surround attached) into existing replace while pulling collar slide plate forward.
• Install gas line into hole provided on side.
• Secure collar slide plate to appliance by placing locking handle into position with locking tabs (see Figure 8.1) and secure with #8 screw.
• Level the appliance from side to side and front to back. Adjust leveling bolts to desired vertical position so appliance is level. Use the leveling bolts included with the manual bag.
• A minimum 1/2 inch gap from the bottom of the appliance to a metal surface is recommended for optimal fan performance. See Figure 5.1.
• Position any excess fl exible vent pipe back up into chimney without sagging. Twist and push flex vent together to shorten.
• Attach surround. Follow instructions for surround installation included with the front.
• Push insert into the opening so that it tightly overlaps the replace opening.
REAR LEVELING LEGS SHIPPED IN THIS POSITION
THE FRONT LEVELING LEGS ARE SHIPPED WITH THE SURROUND. THEY SHOULD BE INSTALLED AS SHOWN.
REAR LEVELING LEGS MAY BE RELOCATED TO LOCATION A OR LOCATION B
LOCATION A
LOCATION B
FRONT LEVELING LEGS MAY BE MOVED TO THIS LOCATION
WARNING! Risk of Fire! Only an approved Hearth & Home Technologies surround may be used to cover inte­gral grills on solid fuel burning fi replaces. No other com- ponents such as shrouds, sheetmetal plates, etc., may be used to seal off vents.
WARNING! Risk of Explosion! Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury.
Figure 8.3
25Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 26
E. Installing Adaptor and Termination Cap
EXHAUST
AIR
VENT PIPE
TERMINATION
CAP
LINK-DV30B
LINKSQ-DV30
Installation
LINK-DV4-30B
LINKSQ-DV4-30
Installation
INLET AIR
VENT PIPE
WARNING:
DO NOT BLOCK
THIS PIPE END!
INLET AIR
VENT PIPE
EXHAUST
AIR
VENT PIPE
CAUTION! Risk of Cuts/Abrasions/Flying Debris.
Wear protective gloves and safety glasses during instal­lation. Sheet metal edges are sharp.
For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 8.4) .
To install adaptor see Figure 8.5.
To prevent odors and cold drafts, the chimney must be sealed around the vent with non-combustible blanket in­sulation or fi eld fabricated metal plates.
HORIZONTAL
OVERHANG
To help eliminate cold air drafts, it may be necessary to place non-combustible insulation around the fl ues as they go though the damper.
Note: The LINK-DV4-30B and LINKSQ-DV4-30 systems REQUIRE this insulation.
2 FT. MIN.
GAS DIRECT VENT TERMINATION CAP
Roof Pitch H (Min.) Ft.
Flat to 6/12....................1.0*
Over 6/12 to 7/12 ........1.25*
Over 7/12 to 8/12 ..........1.5*
Over 8/12 to 9/12 ..........2.0*
Over 9/12 to 10/12 ........2.5*
Over 10/12 to 11/12 ..... 3.25
20 INCHES MIN.
LOWEST
DISCHARGE
OPENING
H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING
X
12
ROOF PITCH
VERTICAL
WALL
IS X/ 12
Roof Pitch H (Min.) Ft.
Over 11/12 to 12/12 ....... 4.0
Over 12/12 to 14/12 ....... 5.0
Over 14/12 to 16/12 ....... 6.0
Over 16/12 to 18/12 ....... 7.0
Over 18/12 to 20/12 ....... 7.5
Over 20/12 to 21/12 ....... 8.0
* 3 foot minimum in snow regions
Figure 8.4 Minimum Height from Roof to Lowest Discharge Opening
Masonry
Factory Built
Wood Burning
OR
Figure 8.6
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 26
OPTIONAL LINK-ZC-ADPB
FOR USE WITH CLASS A
WOODBURNING PIPE
Note: Untwist the pipe while extend­ing it, to achieve full 30’ length.
Remove 18 inch x 18 inch fl ashing on cap by removing 3 screws. Connect both the LINK-ZC-ADPB to Class A Pipe and the termination cap to the LINK-ZC-ADPB with the self tapping screws provided.
Page 27
9
9
Gas Information
A. Fuel Conversion
• Make sure the appliance is compatible with available gas types.
• Conversions must be made by a qualifi ed technician (NFI certifi ed or factory-trained) using Hearth & Home Technologies specifi ed and approved parts.
B. Gas Pressure
• Optimum appliance performance requires proper input pressures.
• Gas line sizing requirements will be determined in ANSI Z221.3 National Fuel Gas Code in the USA and CAN/ CGA B149 in Canada.
• Pressure requirements are:
Gas Pressure Natural Gas Propane
Minimum inlet pressure 5.0 in. w.c. 11.0 in. w.c.
Maximum inlet pressure 10.0 in. w.c. 13.0 in. w.c.
Manifold pressure 3.5 in. w.c. 10.0 in. w.c.
WARNING! Risk of Fire/Explosion! High pressure will damage valve. Low pressure may cause explosion.
• Verify inlet pressures. Verify minimum pressures when other household gas appliances are operating.
• Install regulator upstream of valve if line pressure is greater than 1/2 psig.
WARNING
Fire Risk.
Explosion Hazard.
High pressure will damage valve.
• Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig.
• Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig.
C. Gas Connection
• Refer to Reference Section 14 for location of gas line access in appliance.
• Gas line may be run through knockout(s) provided.
• The gap between supply piping and gas access hole may be caulked with caulk with a minimum of 300ºF continuous exposure rating or stuffed with non­combustible, unfaced insulation to prevent cold air infi ltration.
• Ensure that gas line does not come in contact with outer wrap of the appliance. Follow local codes.
• Pipe incoming gas line into valve compartment.
• Connect incoming gas line to the 1/2 in. (13 mm) connection on manual shutoff valve.
WARNING! Risk of Fire/Explosion! Support control when attaching pipe to prevent bending gas line.
• A small amount of air will be in the gas supply lines.
WARNING! Risk of Fire/Explosion! Gas build-up during line purge could ignite.
• Purge should be performed by technician certifi ed by
NFI or factory-trained.
• Ensure adequate ventilation.
• Ensure there are no ignition sources such as sparks
or open fl ames.
Light the appliance. It will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally.
WARNING! Risk of Fire, Explosion or Asphyxiation!
Check all fi ttings and connections with a non-corrosive commercially available leak-check solution. DO NOT use open fl ame. Fittings and connections could have loos- ened during shipping and handling.
WARNING! Risk of Fire! DO NOT change valve settings. This valve has been preset at the factory.
Note: Have the gas supply line installed in accordance with local codes, if any. If not, follow ANSI 223.1. Installation should be done by a qualifi ed installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fi tter).
Note: A listed (and Commonwealth of Massachusetts ap­proved) 1/2 inch (13 mm) T-handle manual shut-off valve and fl exible gas connector are connected to the 1/2 inch (13 mm) control valve inlet.
• If substituting for these components, please consult local codes for compliance.
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce burner orifi ce 4% for each 1000 feet above 2000 feet.
• In the CANADA: Reduce burner orifi ce 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility.
27Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 28
10
10
Electrical Information
A. Wiring Requirements
NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric Code CSA C22.1.
• This appliance comes with a 110-120 VAC cord assembly. This is required for proper operation of the appliance (IntelliFire Ignition). An outlet box may be installed in a bottom back corner of the existing solid fuel masonry or factory built fi replace to plug in the cord assembly, or the supplied power cord may be routed out onto the hearth to a nearby outlet.
• A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.
• Low voltage and 110-120 VAC voltage cannot be shared within the same wall box.
WARNING! Risk of Shock or Explosion! DO NOT wire 110-120 VAC to the valve or to the appliance wall switch. Incorrect wiring will damage controls.
WARNING! Risk of Shock! Label all wires prior to dis­connection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with type 105° C rated wire. Wire must have high temperature insulation.
B. IntelliFireTM Plus Ignition System Wiring
• Wire an outlet box (110-120 VAC) in the bottom back corner of the existing solid fuel masonry or factory built replace to plug in the cord assembly, or the supplied cord assembly may be rerouted out onto the hearth to a nearby outlet for proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire IPI controlled appliance junction box to a switched circuit. Incorrect wiring will override IPI safety lockout.
• Refer to Figure 10.1, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFireTM Plus control valve which operates on a 6 volt system.
• Plug the 6 volt transformer plug into the appliance cord assembly to supply power to the unit OR install 4 AA cell batteries (not included) into the battery tray before use. See Section 2.G for instructions on locating battery tray and installing batteries.
• Battery longevity and performance will be affected by the service temperatures of this appliance. Batteries should only be used as a power source in the event of an emergency such as an outage.
MODULE RESET
SWITCH
TO CORD ASSEMBLY
120VAC
WIRE ASSEMBLY
ORANGE
(PILOT)
INTERMITTENT PILOT IGNITOR
GREEN
(MAIN)
GROUND
MODULE
ORG WHT
AUX WIRE EXTENSION
BLACK
RED
BROWN
BATTERY PACK
6V DC (AA X 4)
EMC FILTER UNIT
RC300 4.5V DC (AAA X 3)
AUX 300
MODULE
FAN
AUX1 AUX2
TO CORD ASSEMBLY
LIGHT WIRE ASSEMBLY
ACCENT SOCKETS (2)
OPTIONAL
AUX2 NOT USED FOR INSERT MODELS. PROTECTIVE COVER INCLUDED.
120VAC
EMBER BULB 50W (2)
Figure 10.1 IPI Wiring Diagram
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 28
NOTE: SEE FIGURE 10.3 FOR ADDITIONAL INFORMATION
Page 29
C. IPI Battery Tray/Battery Installation
The IntelliFireTM Plus system has a battery backup option. Batteries should only be placed in the battery pack when 110-120 VAC is not available. See Section 2.G.
D. Control Module Operation
See Section 2.H for control module operation instructions.
Note: if any of the original wire as supplied with the appliance must be replaced, it must be replaced with type 105 °C rated wire.
E. Programming the RC300 to the Control
Module
CAUTION! Risk of burns! DO NOT program the remote control to the control module when fi replace is hot.
• Refer to the RC300 Installation Instructions included in appliance manual bag to program the RC300 to the control module.
$
8
;
BLOWERS
,
/
,
$
5
<
PLUG INTO 120V EXISTING OUTLET
ORANGE - TO VALVE GROUND - TO VALVE BRACKET
GREEN - TO VALVE
,
3
, 0
BRN
2
'
8
/
(
TO IPI MODULE
RED
BLK
WHT
WHT
GRN
BLK
GRN
BLK
PLUG INTO
EXISTING
OUTLET
FUSE WIRE ASSEMBLY
FUSE WIRE
ASSEMBLY
BLK
GRN
BLK
BLOWERS
BLK
GRN
BLK
Figure 10.2 Fan Wiring Diagram
29Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 30
11
11
Finishing
A. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear­ances to combustibles as specifi ed. Framing or fi nishing material closer than the minimums listed must be construct­ed entirely of noncombustible materials (i.e., steel studs, concrete board, etc).
Clearance to combustible material under the insert is 1/4 inch (6 mm). Clearance from top of fi replace opening for combustibles extending 12 inches max. is 12 inches.
• Use leveling legs to raise insert minimum 1/4 inch (6 mm) above combustible material or outer wrap of factory built rebox.
Combustible facings must not extend behind the insert surround. For non-combustible material specifi cations refer to section 1.E.
EXISTING NON-COMBUSTIBLE FACING
B. Remove the Shipping Materials
Remove shipping materials from inside or underneath the rebox. Remove metal panels covering electrical compo­nents on sides of appliance.
C. Inspect Firebox
Surface cracking or crazing of fi rebrick material is normal and expected. All cracks are acceptable and do not require replacement of the unit or the fi rebox with the exception of:
• Cracks compromising the surface plane of the fi rebox.
See Figure 11.5.
Figure 11.1 Mantel Clearance
12 IN. MAX.
12 IN. MIN.
10 IN. MIN.
2 IN. MAX.
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 30
Page 31
12
12
Appliance Setup
A. Remove Glass Assembly
See Section 12.I.
B. Remove the Shipping Materials
Remove shipping materials from inside or underneath the rebox. Remove metal panels covering electrical compo­nents on sides of appliance.
C. Inspect Firebox
Surface cracking or crazing of fi rebrick material is normal and expected. All cracks are acceptable and do not require replacement of the unit or the fi rebox with the exception of:
• Cracks compromising the surface plane of the fi rebox.
See Figure 12.1.
F. Place the Lava Rock
WARNING! Risk of Explosion! Follow lava rock place­ment instructions in manual. DO NOT place lava rock on burner. Improperly placed lava rock interferes with proper burner operation.
Lava rock is shipped with this gas appliance. To place the lava rock:
• Lava rock CANNOT be placed on the burner.
• Place lava rock in front of and to the sides of the burner.
PLACE LAVA ROCK IN GRAY AREA ONLY
Figure 12.1 Surface plane of fi rebox is comprised and should be replaced.
D. Clean the Appliance
Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the control cavity.
E. Accessories
Install approved accessories per instructions included with accessories. Contact your dealer for a list of ap­proved accessories.
WARNING! Risk of Fire and Electric Shock! Use ONLY Hearth & Home Technologies-approved optional acces­sories with this appliance. Using non-listed accessories could result in a safety hazard and will void the warranty.
Figure 12.2 Placement of Lava Rock
31Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 32
G. Ember Placement
WARNING! Risk of Explosion! Follow ember placement instructions in manual. DO NOT place embers directly over burner ports. Replace ember material annually. Improperly placed embers interfere with proper burner operation.
Ember material is shipped with this gas appliance. To place the ember material:
• Embers CANNOT be placed directly over ports. Care
should be taken not to cover the lighting trail of ports (from back to front).
• Place dime-size pieces of Glowing Embers® just in front
of the port trail, but not on or in between the ports. See Figure 12.3 (QFI30FB-C) or Figure 12.4 (QFI35FB-C). Care should be taken so that the ports are not covered. Failure to follow this procedure will likely cause lighting and sooting problems.
• Save the remaining ember materials for use during
appliance servicing. The embers provided should be enough for 3 to 5 applications.
EMBERS NOT ALLOWED IN PILOT AREA
Figure 12.3 Placement of Embers (QFI30FB-C)
EMBERS NOT ALLOWED IN PILOT AREA
Figure 12.4 Placement of Embers (QFI35FB-C)
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 32
Page 33
H. Install the Log Assembly
GRATE TINES
PILOT BRACKET
LOG PINS
LIGHT TRAYS
GRATE BAR
1
2
5
6
4
3
7
GLASS ROCK
LOG RESTS AGAINST BACK OF FIREBOX
CENTER LOG OVER PILOT BRACKET
FLAT SPOT FOR LOG #6
RECESSED AREA OF LOG MATES WITH BURNER TOP
1
2
SRV2221-703
SRV2221-701
SRV2221-704
SRV2221-707
SRV2221-705
SRV2221-706
SRV2221-702
Log Set Assembly: LOGS-QFI30FB Models: QFI30FB, QFI30FB-C
SRV2221-707
5
SRV2221-704
SRV2221-701
2
SRV2221-703
1
PILOT BRACKET
7
SRV2221-705
6
SRV2221-706
4
SRV2221-702
3
Figure 1. Logs Installed
GLASS ROCK
LIGHT TRAYS
LOG PINS
GRATE BAR
GRATE TINES
Figure 2. Reference Points for Log Placement
CAUTION: Logs are fragile, handle with care. Glass Rock (2201-853):Fill each light tray evenly with the glass rock.
LOG RESTS AGAINST BACK OF FIREBOX
CENTER LOG OVER PILOT BRACKET
1
Figure 3. Install Glass Rock
FLAT SPOT FOR LOG #6
RECESSED AREA OF LOG MATES WITH BURNER TOP
2
Figure 4. Place Log #1 Figure 5. Place Log #2
Log #1 (SRV2221-703): Position Log #1 as shown in Figure 4. See Figure 2 for additional points of reference. Center the
log over the pilot bracket. Pull the log forward until contact is made with burner.
Log #2 (SRV2221-701): Position Log #2 as shown in Figure 5. See Figure 2 and Figure 6 for additional points of reference. The recessed area on the bottom of the log and the back right corner of the burner top mate.
33Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 34
MATE LOG PIN WITH LOG SLOT
4
FRONT
FRONT
RECESSED AREA
2
BACK
FLAT SPOT
FOR LOG #5
LOG TOUCHES
FIREBOX
3
3
BASE OF GRATE TINE FITS IN GROOVE
BASE TINE
MATE GRATE TINE WITH LOG SLOT
4
GRATE TINE SLOT
LOG PIN SLOT
FRONT
BACK
FLAT SPOT FOR LOG #6
LOG GROOVE FOR LOG #7
5
RIGHT
LEFT
RECESSED AREA
2
BACK
FLAT SPOT
FOR LOG #5
LOG TOUCHES
FIREBOX
3
Figure 6. Log #2
Log #3 (SRV2221-702): Position Log #3 as shown in Figure 7. See Figure 2 and Figure 8 for additional reference points.
Mate the base of the left grate tine with the groove located on the bottom of the log. Pull the log forward until it stops against the vertical portion of the grate tine. Swing the rear of the log counterclockwise until it touches the fi rebox.
BASE OF GRATE TINE FITS IN GROOVE
BASE TINE
3
BACK
Figure 8. Log #3 - Bottom View Figure 9. Place Log #4
Log #4 (SRV2221-706): Position Log #4 as shown in Figure 9. See Figure 2 and Figure 10 for additional references. Mate
the grate tine slot with the base of the right grate tine. The grate tine slot is located on the bottom right end of Log #4. See Figure 10. Slide the right end of the log forward until the tine fully engages the slot. Mate the log pin slot with the right log pin.
FRONT
Figure 7. Place Log #3
MATE LOG PIN WITH LOG SLOT
MATE GRATE TINE WITH LOG SLOT
4
GRATE TINE SLOT
4
RIGHT
Figure 10. Log #4 - Bottom View
Log #5 (SRV2221-704): Position Log #5 as shown in Figure 11. See Figure 2 and Figure 12 for additional references. Rest
the left end of Log #5 on the fl at spot indicated in Figure 7. Mate the slot, located on the bottom of the log, with the left log pin. Ensure the nose of the log does not cover any burner ports.
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 34
LOG PIN SLOT
LEFT
LOG GROOVE FOR LOG #7
Figure 11. Place Log #5
FLAT SPOT FOR LOG #6
5
Page 35
6
PLACE END OF LOG
PLACE END OF LOG
ON FLAT SPOT
PLACE END OF LOG ON FLAT SPOT
7
PLACE END OF LOG ON FLAT SPOT
REST END OF LOG ON THE LEFT SIDE OF KNOT
KNOT
ON FLAT SPOT
6
PLACE END OF LOG ON FLAT SPOT
Figure 12. Place Log #6
Log #6 (SRV2221-705): Position Log #6 as shown in Figure 12. See Figures 2, 5 and 11 for additional reference points.
Place the front end of log #6 n the fl at spot indicated in Figure 11. Place the back end of Log #6 on the fl at spot indicated in Figure 5.
REST END OF LOG ON THE LEFT SIDE OF KNOT
PLACE END OF LOG ON FLAT SPOT
KNOT
7
Figure 13. Place Log #7
Log #7 (SRV2221-707): Position Log #7 as shown in Figure 13. See Figure 2 and 11 for additional reference points. Place
the front end of Log #7 on the fl at spot indicated in Figure 11. Place the back end of Log #7 on the left side of the knot. See Figure 13.
2221-935C
35Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 36
H. Install the Log Assembly
GRATE TINES
PILOT BRACKET
LOG PINS
LIGHT TRAYS
LOG SUPPORTS
GRATE BAR
6
5
1
2
4
7
3
GLASS ROCK
FLAT SPOT
FOR LOG #7
FLAT SPOT
FOR LOG #6
LOG #1 CONTACTS BURNER
LEDGE AT TWO POINTS
CENTER LOG CUT OUT OVER PILOT BRACKET
LOG #2 TOUCHES LOG #1 HERE
LOG #2 CONTACTS
RIGHT FIREBOX WALL
1
2
1
BURNER LEDGE
BURNER LEDGE
SRV2223-703
SRV2223-701
SRV2223-702
SRV2223-704
SRV2223-706
SRV2223-705
SRV2223-707
Log Set Assembly: LOGS-QFI35FB Models: QFI35FB, QFI35FB-C
2
SRV2223-701
5
SRV2223-704
6
SRV2223-705
BURNER LEDGE
GRATE BAR
SRV2223-703
SRV2223-702
SRV2223-706
PILOT BRACKET
LIGHT TRAYS
LOG PINS
1
3
SRV2223-707
4
LOG SUPPORTS
BURNER LEDGE
7
Figure 1. Logs Installed
GLASS ROCK
GRATE TINES
Figure 2. Reference Points for Log Placement
CAUTION: Logs are fragile, handle with care.
Glass Rock (2201-853): Fill each light tray evenly with the glass rock.
WARNING! Risk of Explosion! DO NOT place glass rock on the burner surface. DO NOT place glass rock directly over burner ports. Improperly placed glass rock interferes with proper burner operation.
FLAT SPOT
FOR LOG #7
1
LOG #1 CONTACTS BURNER
LEDGE AT TWO POINTS
CENTER LOG CUT OUT OVER PILOT BRACKET
Figure 4. Place Log #1 Figure 5. Place Log #2
Log #1 (SRV2223-703): Position Log #1 as shown in Figure 4. See Figure 2 for additional points of reference. Center the
log over the pilot bracket. The log should rest on the burner ledge as shown in Figure 4.
Log #2 (SRV2223-701): Position Log #2 as shown in Figure 5. See Figure 2 for additional points of reference. Place the left end of the log on the rear log support. Slide the log back until it rest against the back of the log support. The left end of the log should touch Log #1. Swing the right end of the log counterclockwise until it contacts the right refractory wall.
Figure 3. Install Glass Rock
LOG #2 TOUCHES LOG #1 HERE
FLAT SPOT
FOR LOG #6
1
LOG #2 CONTACTS
RIGHT FIREBOX WALL
2
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 36
Page 37
MATE LOG PIN
WITH LOG SLOT
4
GRATE TINE GROOVE
FRONT
BACK
BURNER TOP GROOVE
3
3
LOG PIN SLOT
LOG CONTACTS
GRATE BAR
5
3
1
2
RIGHT
LEFT
REST ENDS OF LOGS
ON THE FLAT SPOTS
6
FLAT SPOT
FLAT SPOT
FOR LOG #5
FLAT SPOT
FOR LOG #7
FLAT SPOT
FOR LOG #6
USE LOG PIN TO
LOCATE LOG
LINE SHOWS BACK
EDGE OF GRATE BAR
LOG #3 TOUCHES GRATE TINE
MATE GROOVE WITH
CORNER OF BURNER TOP
4
REST LOG ON
FLAT SPOT
LOG #3 TOUCHES GRATE TINE
BURNER TOP GROOVE
GRATE TINE GROOVE
3
FRONT
Figure 6. Log #3 - Bottom View
Log #3 (SRV2223-702): Position Log #3 as shown in Figure 7. See Figure 2 and Figure 6 for additional references. Mate
the grate tine groove with the base of the left grate tine. Slide the log forward until it stops against the vertical portion of the left grate tine. Mate the burner top groove with the left edge of the burner top as shown in Figure 7.
LOG PIN SLOT
BACK
Figure 7. Place Log #3
3
FOR LOG #5
MATE GROOVE WITH
CORNER OF BURNER TOP
4
4
MATE LOG PIN
WITH LOG SLOT
LOG CONTACTS
LEFT
Figure 8. Log #4 - Bottom View Figure 9. Place Log #4
Log #4 (SRV2223-706): Position Log #4 as shown in Figure 9. See Figure 2 and Figure 8 for additional references. Mate
the slot located at the left end of log #4, shown in Figure 8, with the right log pin. Rotate the right end of the log clockwise, until the log contacts the grate bar.
FLAT SPOT
FOR LOG #7
1
REST LOG ON
FLAT SPOT
3
LINE SHOWS BACK
EDGE OF GRATE BAR
5
FLAT SPOT
FOR LOG #6
USE LOG PIN TO
RIGHT
LOCATE LOG
REST ENDS OF LOGS
ON THE FLAT SPOTS
2
GRATE BAR
6
Figure 10. Place Log #5
Log #5 (SRV2223-704): Position Log #5 as shown in Figure 10. See Figure 2 and Figure 7 for additional references. Rest
the left end of the log on the fl at spot of log #3. Locate the groove located on the right end of the log. Mate the groove with the grate bar. Use the left log pin to positively locate the right end of the log.
Log #6 (SRV2223-705): Position Log #6 as shown in Figure 11. See Figures 2, 5 and 10 for additional reference points. Place the front and back ends of the log on the fl at spots as shown in Figure 11.
Figure 11. Place Log #6
37Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 38
7
PLACE END OF LOG ON FLAT SPOT
REST END OF LOG
REST END OF LOG
ON THE LEFT SIDE OF KNOT
KNOT
ON THE LEFT SIDE OF KNOT
KNOT
PLACE END OF LOG ON FLAT SPOT
Figure 12. Place Log #7
7
Log #7 (SRV2221-707): Position Log #7 as shown in Figure 12. See Figure 2 and 10 for additional reference points. Place
the front and back ends of the log on the fl at spots as shown in Figure 12.
2223-935C
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 38
Page 39
I. Fixed Glass Assembly
WARNING! Risk of Asphyxiation! Handle fi xed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches.
DO NOT strike, slam or scratch glass.
DO NOT operate replace with glass removed, cracked,
broken or scratched.
Replace as a complete assembly.
Removing Fixed Glass Assembly
The glass assembly fastens to the fi replace in four
places. The fastening mechanisms are spring-loaded glass latches. An example of the glass latch is shown in Figure 12.2.
• To release glass assembly, pull the two top spring-
loaded latches forward and allow them to retract away from the glass assembly. Slide the glass as­sembly outward and downward until top of the glass
frame will clear the surround.
J. Air Shutter Setting
Air shutter settings should be adjusted by a qualifi ed ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical runs. See Figure 12.3.
NOTICE: If sooting occurs, provide more air by opening the air shutter.
AIR SHUTTER
Replacing Fixed Glass Assembly
Tilt glass assembly toward fi replace and slide glass
assembly downward to engage bottom latches. Verify bottom latches are fully engaged and then fasten the two top latches.
Note that the extended glass latch tabs on the glass
frame are for the bottom glass latches.
LATCHES
(BOTH BOTTOM
AND TOP)
GLASS
ASSEMBLY
Figure 12.3 Air Shutter
Air Shutter Settings
NG LP
QFI30FB-C 1/4 in. Full Open
QFI35FB-C 1/4 in. Full Open
Figure 12.2 Fixed Glass Assembly
39Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 40
13
13
With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualifi ed technician in the diagnosis of a problem and the corrective action to be taken. This troubleshooting guide can only be used by a qualifi ed technician. Contact your dealer to arrange a service call by a qualifi ed technician.
Troubleshooting
A. IntelliFire™ Plus Ignition System
Symptom Possible Cause Corrective Action
1. Pilot won’t light. The ignitor/module makes noise, but no spark.
2. Pilot won’t light, there is no noise or spark.
3. Pilot sparks, but Pilot will not light.
A. Incorrect wiring. Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor are
connected to correct terminals on module and pilot assembly.
B. Loose connections or electrical
shorts in the wiring.
C. Ignitor gap is too large. Verify gap of igniter to right side of pilot hood. The gap should be
A. No power, transformer installed
incorrectly, or depleted batteries.
B. A shorted or loose connection in
wiring confi guration or wiring har- ness.
C. Improper wall switch wiring. Verify that 110-120 VAC power is “ON” to junction box.
D. Module not grounded. Verify black ground wire from module wire harness is grounded to
A. Gas supply. Verify that incoming gas line ball valve is “open”. Verify that inlet
Verify no loose connections or electrical shorts in wiring from mod­ule to pilot assembly. Verify connections underneath pilot assembly are tight; also verify igniter and fl ame sense wires are not grounding out to metal chassis, pilot burner, pilot enclosure, mesh screen if present, or any other metal object.
approximately .17 in. or 1/8 in. (3 mm).
Verify that transformer is installed and plugged into module. Check voltage of transformer at connection to module. Acceptable read­ings of a good transformer are between 6.4 and 6.6 volts DC. Bat­tery power supply voltage must be at least 4 volts. If below 4 volts, replace batteries.
Remove and reinstall the wiring harness that plugs into module. Verify there is a tight fi t. Verify pilot assembly wiring to module. Re- move and verify continuity of each wire in wiring harness. Replace any damaged components.
metal chassis of appliance.
pressure reading is within acceptable limits.
B. Ignitor gap is too large. Verify gap of igniter to right side of pilot hood. The gap should be
C. Module is not grounded. Verify module is securely grounded to metal chassis of appliance.
D. Pilot valve solenoid Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module.
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 40
approximately .17 in. or 1/8 in. (3 mm).
If below 1.5 volts, replace module. If 1.5 volts or greater, replace valve.
Page 41
Troubleshooting (continued)
Symptom Possible Cause Corrective Action
4. Pilot lights but con-
tinues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame rectifi cation has not occurred.)
A. A shorted or loose connection in
ame sensing rod.
B. Poor fl ame rectifi cation or contami-
nated fl ame sensing rod.
C. Module is not grounded. Verify module is securely grounded to metal chassis of appliance.
D. Damaged pilot assembly or con-
taminated fl ame sensing rod.
Verify all connections to wiring diagram in manual. Verify connec­tions underneath pilot assembly are tight. Verify fl ame sense or ig- niter wires are not grounding out to metal chassis, pilot burner, pilot enclosure or screen if present, or any other metal object.
With fi xed glass assembly in place, verify that fl ame is engulfi ng ame sensing rod on left side of pilot hood. Flame sensing rod should glow shortly after ignition. With a multi-meter, verify that current in series between module and sense lead is at least 0.14 microamps. Verify correct pilot orifi ce is installed and gas inlet is set to pressure specifi cations. Polish fl ame sensing rod with fi ne steel wool to remove any contaminants that may have accumulated on ame sensing rod.
Verify that wire harness is fi rmly connected to the module.
Verify that ceramic insulator around the fl ame sensing rod is not cracked, damaged, or loose. Verify connection from fl ame sensing rod to white sensor wire. Polish fl ame sensing rod with fi ne steel wool to remove any contaminants that may have accumulated on ame sensing rod. Verify continuity with a multi-meter with ohms set at lowest range. Replace pilot if any damage is detected.
41Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 42
14
14
Reference Materials
A. Appliance/Decorative Front Dimension Diagrams
Dimensions are actual appliance dimensions. Use for reference only.
A
L
B
C
D
E
K
P
M
N
O
MODEL DIMENSIONS
Location
A 33-13/16 859 29-3/8 746
B 24-15/16 633 20-15/16 532
C 10-11/16 271 8-11/16 221
D 3-11/16 94 3-11/16 94
E 4-3/8 111 4-1/4 108
F 13-3/8 340 11-7/8 302
G 6-9/16 167 5-3/4 146
H 33-7/8 860 29-3/16 741
I 6-3/4 172 6-3/4 172
J 12 305 10-1/2 267
K 1-5/16 33 1-5/16 33
QFI35FB-C QFI30FB-C
Inches Millimeters Inches Millimeters
J
Q
I
H
R
MODEL DIMENSIONS
Location
L 1-7/8 48 1-7/8 48
M 1-1/2 38 1-1/2 38
N 5-7/16 138 4-1/2 114
O 16-5/8 422 15-1/8 384
P 24-3/8 619 22-5/16 567
Q 19-7/8 505 17-7/8 454
R 31-3/8 797 26-11/16 678
S 2-5/16 59 2-1/4 57
T 1-1/4 32 1-1/4 32
U 10-5/16 262 9-13/16 249
V 6-1/4 159 5-5/16 135
W 21-3/4 552 19-15/16 506
QFI35FB-C QFI30FB-C
Inches Millimeters Inches Millimeters
F
G
W
T
S
V
U
*Note: Location O on Figure 14.1 is measuring the appliance depth, for installation depth reference Location G on Figure 5.2.
Figure 14.1 Appliance Dimensions
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 42
Page 43
FS-QFI30FB, FS-QFI35FB DECORATIVE FRONTS
D
F
E
FS-QFI30FB
FS-QFI35FB
B
G
ABC D E F G
in. 26-7/8 17-7/8 2-1/4 36-1/2 25-7/16 25 7/16
mm 683 454 57 927 646 635 11
in. 31-7/16 20 2-3/16 38-7/16 27-7/16 27 7/16
mm 799 508 56 976 697 686 11
A
C
FSL-QFI30FB, FSL-QFI35FB DECORATIVE FRONTS
D
F
E
FSL-QFI30FB
FSL-QFI35FB
A
G
ABC D E F G
in. 28-7/16 19-7/16 2-3/4 36-1/2 25-1/2 25 1/2
mm 722 493 70 927 648 635 13
in. 30-7/16 21-7/16 2-3/4 38-1/2 27-1/2 27 1/2
mm 773 545 70 978 699 686 13
B
C
Figure 14.2 Decorative Front Dimensions - FS-QFI30FB/FS-QFI35FB and FSL-QFI30FB/FSL-QFI35FB
43Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 44
TP-QFI30FB, TPQFI35FB DECORATIVE FRONTS
D
E
TP-QFI30FB
TP-QFI35FB
F
A
G
ABC D E F G
in. 32-1/2 15 4-7/8 36-9/16 26-1/2 26 1/2
mm 826 381 124 929 673 660 13
in. 34-1/2 16-7/8 4-7/8 38-9/16 28-1/2 28 1/2
mm 876 429 124 979 724 711 13
TB-QFI30FB/TB-QFI35FB DECORATIVE FRONTS
D
B
C
EF
G
TB-QFI30FB
TB-QFI35FB
Figure 14.3 Decorative Front Dimensions - TP-QFI30FB/TP-QFI35FB and TB-QFI30FB/TB-QFI35FB
in. 28-13/16 16-5/16 5 36-1/2 25-1/2 25 1/2
mm 732 414 127 927 648 635 13
in. 30-13/16 18-5/16 5 38-1/2 27-1/2 27 1/2
mm 783 465 127 978 699 686 13
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 44
B
A
C
ABC D E F G
Page 45
B. Vent Kits Components
Direct Vent Flex Liner Kits (see Figure 14.4)
LINK-DV30B: Masonry 3 inch fl ex liner kit. Expands to 30 feet. Includes: two liners, termination cap and fl ashing.
LINK-DV4-30B: Masonry 3 inch fl ex liner kit. Expands to 30 feet and 4 feet respectively. Includes: two liners, termination cap and fl ashing.
LINKSQC-DV30, LINKSQB-DV30: Masonry 3 inch fl ex liner kit. Expands to 30 feet. Includes: two liners, termination cap and fl ashing.
LINKSQC-DV4-30, LINKSQB-DV4-30: Masonry 3 inch ex liner kit. Expands to 30 feet and 4 feet respectively. Includes: two liners, termination cap and fl ashing.
LINK-ZC-ADPB
DV-46DVA-GK
LINK-DV30B
LINK-DV4-30B
Figure 14.4 Direct Vent Flex Liner Kits
LINKSQC-DV30 (COPPER)
LINKSQB-DV30 (BLACK)
LINKSQC-DV4-30 (COPPER)
LINKSQB-DV4-30 (BLACK)
Direct Vent Flex Liner Accessory Kits (see Figure 14.5)
LINK-ZC-ADPB: Zero clearance chimney adapter
DV-46DVA-GK: Adapter kit - It is permissible to use DV­46DVA-GK to connect collinear fl ex vent to SL-D vent pipe to extend the run.
FLEX3-30: One 3 inch fl exible liner expands to 30 feet.
FLEX-CNCT: Connector kit - 3 inch liner to 3 inch liner, one connector per kit.
FLEX3-30
FLEX-CNCT
Figure 14.5 Direct Vent Flex Liner Accessory Kits
45Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 46
R
C. Service Parts
Service Parts
QFI30FB-C
Log Set Assembly
7
1
5
3
30” Gas Insert - DV
Beginning Manufacturing Date: Aug 2011
Ending Manufacturing Date: Active
8
9
6
2
19
10
4
12
11
13
18
17
16
14
15
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or
distributor. model number and serial number when requesting service parts from your dealer or distributor.
Hearth and Home Technologies does not sell directly to consumers. Provide
Stocked
at Depot
ITEM DESCRIPTION COMMENTS PART NUMBER
Log Assembly LOGS-QFI30FB
1 Log 1 SRV2221-701
2 Log 2 SRV2221-702
3 Log 3 SRV2221-703
4 Log 4 SRV2221-704
5 Log 5 SRV2221-705
6 Log 6 SRV2221-706
7 Log 7 SRV2221-707
8 Termination Plate Assembly 2201-012
Gasket, Termination Plate 2201-401
Slide Plate Handle 2019-201
9 Module Bracket 2201-137
10
11
12
13 Glass Door Assembly GLA-2201
14 Power Cord Assembly 2201-024
15 Valve Assembly Refer to valve page
16 Aux Bracket 2201-157
17 RIV-NUT Backet Assembly Qty 2 req
18 Blower Assembly GFK-210-C
19
Additional service part numbers on following page. 2/15
Burner Assembly
Media Tray
Grate Assembly 2221-016
Cover Plate, Back 2202-104
2221-009
2201-112
2201-027
Y
Y
Y
Y
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 46
Page 47
R
Service Parts
QFI35FB-C
35” Gas Insert - Dv
Log Set Assembly
Beginning Manufacturing Date: Aug 2011
Ending Manufacturing Date: Active
8
9
1
5
7
6
3
2
4
12
11
10
13
17
16
14
15
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or
distributor. model number and serial number when requesting service parts from your dealer or distributor.
ITEM DESCRIPTION COMMENTS PART NUMBER
10
11
12
13 Glass Door Assembly
14 Power Cord Assembly
15 Valve Assembly
16 Aux Bracket
17 RIV-NUT Backet Assembly Qty 2 req 2201-027
18 Blower Assembly
19 Cover Plate, Back
Additional service part numbers on following page. 2/15
Hearth and Home Technologies does not sell directly to consumers. Provide
Log Assembly
1 Log 1
2 Log 2
3 Log 3
4 Log 4
5 Log 5
6 Log 6
7 Log 7
8 Slide Plate Assembly
Gasket, Termination Plate
Slide Plate Handle
9 Module Bracket
Burner 2223-009 Y
Media Tray 2202-112
Grate Assembly
LOGS-QFI35FB Y
SRV2223-703
SRV2223-701
SRV2223-702
SRV2223-706
SRV2223-704
SRV2223-705
SRV2221-707
2202-012
2201-401
2019-201
2201-137
2223-016
GLA-2202 Y
2201-024
Refer to valve page
2201-157
GFK-210-C
2202-104
Stocked at Depot
19
18
47Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 48
#15 Valve Assembly
R
Service Parts
15.2
QFI30FB-C, QFI35FB-C
Beginning Manufacturing Date: Aug 2011
Ending Manufacturing Date: Active
15.1
15.18
15.16
15.17
15.15
15.14
15.13
15.12
15.9
15.10
15.11
15.4
15.6
15.3
15.5
15.7
15.8
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or
distributor. model number and serial number when requesting service parts from your dealer or distributor.
ITEM DESCRIPTION COMMENTS PART NUMBER
15.1
15.2
15.3
15.4
15.5 Valve Bracket
15.6
15.7 Air Passage Divider
15.8
15.9 Light Wire Assembly
15.10 Jumper Wire, Wall Switch
15.11 Transformer, 6 Volt Wall
15.12 Auxilliary Box
15.13 **Battery Pack
15.14 Module
15.15 Wire Assembly
15.16 Pilot Bracket
15.17 Air Scoop
15.18 Ember Glass
**Fuse for battery pack can be sourced locally, not a warranty item. Specs are 250v, 1A fuse, 3/4" long
Additional service part numbers on following page.
Hearth and Home Technologies does not sell directly to consumers. Provide
Pilot Assembly NG
Pilot Assembly LP
Burner Orifi ce NG (#33C)
Burner Orifi ce LP (#50C)
Burner Orifi ce NG (#31C)
Burner Orifi ce LP (#49C)
Flex Assembly
Flex Ball Valve Assembly
Valve NG
Valve LP
Ember Bulb
QFI30FB-C
QFI35FB-C
QFI30FB-C 2201-144
QFI35FB-C 2202-144
Qty 2 req 2201-150 Y
2202-013 Y
2202-014 Y
582-833 Y
582-850 Y
582-831 Y
582-849
383-302A Y
2201-108 Y
2202-108
2166-302 Y
2166-303 Y
2201-011 Y
2179-300 Y
2326-131 Y
2166-335 Y
2166-323 Y
2166-307 Y
2201-304 Y
2201-025
2201-156
2201-115 Y
Stocked at Depot
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 48
Page 49
R
Service Parts
QFI30FB-C, QFI35FB-C
Beginning Manufacturing Date: Aug 2011
Ending Manufacturing Date: Active
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or
distributor. model number and serial number when requesting service parts from your dealer or distributor.
Hearth and Home Technologies does not sell directly to consumers. Provide
ITEM DESCRIPTION COMMENTS PART NUMBER
Ember Rocks 2201-853
Fan Wire Assembly 2206-068
Fuse Wire Assembly 2206-085
Glass Clip Support Assembly
Glass Latch Support Assembly
Pkg of 2 33858/2 Y
Qty 2 req
2146-413
Lava Rock 4021-296
Mineral Wool 050-721
Patch Kit, Firebrick PATCHKIT-FB
Remote RC300-QDF
Stainless Steel Liner 768-380A
Touch up Paint TUP-GBK-12
Wire Assembly, Module Reset 2201-030
Touch up Paint, Fiber STRATFORD-KIT
EMC Filter 2201-198
Stocked at Depot
Y
Y
Y
Y
Conversion Kit NG NGK-I30FB-C
Conversion Kit LP LPK-I30FB-C
Pilot Orifi ce NG 593-528
Pilot Orifi ce LP 593-527
Regulator NG NGK-DXV-50
Regulator LP LPK-DXV-50
Conversion Kit NG NGK-I35FB-C
Conversion Kit LP LPK-I35FB-C
Pilot Orifi ce NG 593-528
Pilot Orifi ce LP 593-527
Regulator NG NGK-DXV-50
Regulator LP LPK-DXV-50
QFI30FB-C Conversion Kits
Y
Y
Y
Y
Y
Y
QFI35FB-C Conversion Kits
Y
Y
Y
Y
Y
Y
49Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Page 50
D. Contact Information
R
Quadra-Fire, a brand of Hearth & Home Technologies
7571 215th Street West, Lakeville, MN 55044
www.quadrafi re.com
Please contact your Quadra-Fire dealer with any questions or concerns.
For the location of your nearest Quadra-Fire dealer,
please visit www.quadrafi re.com.
- NOTES -
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
NOTICE
DO NOT DISCARD THIS MANUAL
• Important operating and maintenance instructions included.
• Read, understand and follow these instructions for safe installation and operation.
• Leave this manual with party responsible for use and operation.
This product may be covered by one or more of the following patents: (United States) 5601073, 5613487, 5647340, 5890485, 5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending.
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 50
2000-945B
Printed in U.S.A. - Copyright 2015
Loading...